This document describes TI's integrated temperature transmitters which consist of a thermocouple, thermal resistance, and temperature transmitter module in a two-wire system. It can measure temperatures from -200°C to 1600°C and output a 4-20 mA current signal. These products are used in various industries to build temperature measurement and control systems by connecting to recorders, computers, and other devices. The document provides details on installation methods, technical parameters, and product selection tables.

Uploaded by

Farida Mammadli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views5 pages

Ti Temperature Transmitter

This document describes TI's integrated temperature transmitters which consist of a thermocouple, thermal resistance, and temperature transmitter module in a two-wire system. It can measure temperatures from -200°C to 1600°C and output a 4-20 mA current signal. These products are used in various industries to build temperature measurement and control systems by connecting to recorders, computers, and other devices. The document provides details on installation methods, technical parameters, and product selection tables.

Uploaded by

Farida Mammadli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Temperature Sensor

Temperature Transmitter
TI

TI integrated temperature transmitter with thermal couple (or thermal resistance) consists of
thermocouple, thermal resistance and temperature transmitter module, adopting two-wire
system, with nonlinear calibration circuit. It can directly measure the temperature of liquid,
gas medium and any special matter within -200~1600℃, and convert the temperature signal
into current output signal of 4~20mADC, and then send to display or for distributed control by
adjusting recorder or computer.
This product is widely applied to petroleum, chemical, metallurgy, power, light industry and
textile, food industries etc. It can be matched with the moving coil instrument, digital
instrument, recording instrument, regulators, and computer and so on to constitute various
temperature measuring control systems.

Product series

A2 economical temperature A3 high temperature abrasion


A1 economical temperature transmitter transmitter with display resistance temperature transmitter

A4 Industry standard A5 integrated economical A7 integrated temperature


temperature transmitter temperature transmitter transmitter with display

89
FEEJOY TECHNOLOGY

A8D Integrated explosion-proof A8-2 Integrated explosion-proof A9 flange type temperature


high temperature transmitter high temperature transmitter transmitter with display

Product features

1.With high precision of cold terminal compensation circuit, compensation accuracy within full temperature range is ±0.5℃;
2.Unique nonlinear calibration circuit, output signal is in linear relationship with the measured temperature;
3.With drift correction system, can ensure the precision within the whole range of working temperature.

TI integrated temperature transmitter installation instructions

INSTALLATION METHODS

installation method on the bend pipe installation method in a horizontal pipe

installation method in the vertical pipe sealing installation method for boiler apertures

90
Technical parameters

Basic error ±0.2% ±0.5% ±1%

Influence of For 0.2 level : 0.02%F.S/℃


13580 ambient For 0.5 level : 0.05%F.S/℃
temperature
changing For 1.0 level : 0.05%F.S/℃
Load resistance negative RL (Ohm)

Output signal 4-20mADC,two-wire system

VS-14V
20mA
Voltage supplied Rated voltage 24VDC
Load capacity Please refer to the left PL~VS relationship chart
675
When the voltage is 24VDC, the load capacity is 0~500℃

RK=
Thermocouple
cold terminal Within working temperature range, <1℃
compensation
Working area error
Working
temperature -25~85℃
range
0 Relative humidity 5~95%, no condensation
14 Power (VS) 36 On-site display Analog pointer indicator : ±2.5%
precision
Load characteristic relationship of RL~VS Digital display indicator : ±1.0%
Power
consumption < 0.5W

Selection table

Temperature sensor/Temperature transmitter


A1: Economical type; A2: Economical type with display; A3: High temperature abrasion-resistance type;
A4: Industrial standard type; A5: Integrated economical type; A7: Integrated display type; A8D: Explosion-proof type;
A8D-2: Explosion-proof type; A9: Flange type with display

Please refer to the sensor type code table on next page

M1: M20×1.5; M2: M27×2; N1: NPT 1/4; N2: NPT 1/2; R1: R 1/4; R2: R1/2;
F1: DN15 PN1.6 RF; F2: DN20 PN1.6 RF; F3: DN25 PN1.6 RF; SS: Other special requirements

A: Bushing; B: Armored;

Unit: mm; e.g.: 350/200

Note: if transmitter output is required, please add the flowing sections.

F: 4~20mA two-wire system; H: 4~20mA/Hart; V: 1~5VDC; Y1: Customized;

1: 1%; 2: 2%; 5:5 %; Y2: Customized;

Number + unit, for example: (0~100℃)


Total length/insertion depth
Connection specification

Temperature range
Encapsulated form

Accuracy grade
Product series

Output signal
Sensor type
Structure

TI - + ()

Please specify your special requirements when ordering.

91
FEEJOY TECHNOLOGY

Sensor type code table:

Category Code Material Graduation Measuring range


0 Copper thermal resistance Cu50 -50~150℃
Thermal 1 Copper thermal resistance Cu100 -50~150℃
resistance 2 Platinum thermal resistance Pt100 -200~600℃
3 Platinum thermal resistance Pt1000 -200~600℃
4 Ni-Cr,BR E 0~1000℃
5 Ni-Cr,Nisi K 0~1300℃
Thermocouple 6 Ni-Cr-Si,Nisi N 0~1300℃
7 Pt-Rh10,Pt-Rh S 0~1600℃
8 Pt-Rh30,Pt-Rh6 B 0~1800℃

Assembly type installation specifications

Fixed thread D
S=36
d M H S D0 nominal pressure
DO
M
P

Φ12
M27×2 32 32 Φ40 10
5 H Φ16

Movable thread 4-d0 D1


d D2 D1 D0 nominal pressure

Φ12
D2
P

Φ16 Φ70 Φ54 Φ6 nomal pressure


Φ20
Fixed flange 4-d0 D1
dD2 D2 D1 D0 d0 H h nominal pressure

Φ12
D0
D2
P

Φ16 Φ95 Φ65 Φ45 Φ14 19 3 6.4


H h
Φ20
Fixed thread cone protective pipe
S=36
d M H S D0 nominal pressure
M

Cone-
M33×2 32 36 Φ48 30
5 shape

Armored type installation specifications

Type Basic parameters Φ8 Φ6 Φ5 Φ4 Φ3 Φ2


Ferrule thread M M16 x 15 M12 x 15
wrench S
Ferrule
S 22 19

H 15
M
P

Fixed ferrule nominal pressure 26MPa


H
35 Movable ferrule nominal pressure normal pressure
D Φ60 Φ50
Ferrule flange
3-d0 D0 Φ42 Φ36
Ferrule wrench S (equispaced) D0
D1 Φ24 Φ20
d0 Φ9 Φ7
D1
D
P

S Φ22 Φ19
2
10 Fixed ferrule nominal pressure 25MPa
35
Movable ferrule nominal pressure normal pressure

92
FEEJOY TECHNOLOGY

Fixed ferrule Movable ferrule

Assembly type working temperature & response time

Working temperature(℃)
Diameter of protective tube Material of protective tube Response time
Long time Short time

Alundum tube 1600 1800


<150
High aluminum tube 1300 1600

Φ16 1Cr18Ni8Ti -200~+800 900

Cr25Ti 1000 1100 <90


Carbon steel 20# -200~+600 800

Alundum tube 1600 1800


<240
High aluminum tube 1300 1600

1Cr18Ni8Ti -200~+800 900


Φ20
Cr25Ti 1000 1100 <90
Carbon steel 20# -200~+600 800

Alundum tube 1600 1800


<360
High aluminum tube 1300 1600
Φ25 1Cr18Ni8Ti -200~+800 900

Cr25Ti 1000 1100 <90


Carbon steel 20# -200~+600 800

Armored type working temperature & response time

Ferrule diameter Φ2 Φ3 Φ4 Φ5 Φ6 Φ8

Thermocouple response time <0.5 <1.2 <2.5 <4 <6 <8

Thermo resistance response time <3 <5 <8 <12 <15

Notes

Please indicate the following information when ordering:

1. Product name 6. Installation and connection mode


2. Type 7. Ambient temperature
3. Graduation 8. Signs of explosion-proof products
4. Temperature measuring range 9. Quantity
5. Overall accuracy, protective tube material, outer diameter, 10. Delivery time
length, and insert depth

If the precision is not indicated, please supply: 1 grade for TI integrated temperature transmitter with thermocouple; 0.5 grade for
TI temperature transmitter with thermoresistance. The protective tube total length of integrated temperature transmitter with
industrial assembled thermocouple (thermalresistance) = insert depth + 150mm.

Special requirements can be negotiated.