Ti Temperature Transmitter
Ti Temperature Transmitter
Temperature Transmitter
TI
TI integrated temperature transmitter with thermal couple (or thermal resistance) consists of
thermocouple, thermal resistance and temperature transmitter module, adopting two-wire
system, with nonlinear calibration circuit. It can directly measure the temperature of liquid,
gas medium and any special matter within -200~1600℃, and convert the temperature signal
into current output signal of 4~20mADC, and then send to display or for distributed control by
adjusting recorder or computer.
This product is widely applied to petroleum, chemical, metallurgy, power, light industry and
textile, food industries etc. It can be matched with the moving coil instrument, digital
instrument, recording instrument, regulators, and computer and so on to constitute various
temperature measuring control systems.
Product series
89
FEEJOY TECHNOLOGY
Product features
1.With high precision of cold terminal compensation circuit, compensation accuracy within full temperature range is ±0.5℃;
2.Unique nonlinear calibration circuit, output signal is in linear relationship with the measured temperature;
3.With drift correction system, can ensure the precision within the whole range of working temperature.
INSTALLATION METHODS
installation method in the vertical pipe sealing installation method for boiler apertures
90
Technical parameters
VS-14V
20mA
Voltage supplied Rated voltage 24VDC
Load capacity Please refer to the left PL~VS relationship chart
675
When the voltage is 24VDC, the load capacity is 0~500℃
RK=
Thermocouple
cold terminal Within working temperature range, <1℃
compensation
Working area error
Working
temperature -25~85℃
range
0 Relative humidity 5~95%, no condensation
14 Power (VS) 36 On-site display Analog pointer indicator : ±2.5%
precision
Load characteristic relationship of RL~VS Digital display indicator : ±1.0%
Power
consumption < 0.5W
Selection table
M1: M20×1.5; M2: M27×2; N1: NPT 1/4; N2: NPT 1/2; R1: R 1/4; R2: R1/2;
F1: DN15 PN1.6 RF; F2: DN20 PN1.6 RF; F3: DN25 PN1.6 RF; SS: Other special requirements
A: Bushing; B: Armored;
Temperature range
Encapsulated form
Accuracy grade
Product series
Output signal
Sensor type
Structure
TI - + ()
91
FEEJOY TECHNOLOGY
Fixed thread D
S=36
d M H S D0 nominal pressure
DO
M
P
Φ12
M27×2 32 32 Φ40 10
5 H Φ16
Φ12
D2
P
Φ12
D0
D2
P
Cone-
M33×2 32 36 Φ48 30
5 shape
H 15
M
P
S Φ22 Φ19
2
10 Fixed ferrule nominal pressure 25MPa
35
Movable ferrule nominal pressure normal pressure
92
FEEJOY TECHNOLOGY
Working temperature(℃)
Diameter of protective tube Material of protective tube Response time
Long time Short time
Ferrule diameter Φ2 Φ3 Φ4 Φ5 Φ6 Φ8
Notes
If the precision is not indicated, please supply: 1 grade for TI integrated temperature transmitter with thermocouple; 0.5 grade for
TI temperature transmitter with thermoresistance. The protective tube total length of integrated temperature transmitter with
industrial assembled thermocouple (thermalresistance) = insert depth + 150mm.
93