Es100 127 PF2M7
Es100 127 PF2M7
Es100 127 PF2M7
Port 0.02
Flow range [L/min] Smallest settable
size 0.01 0.05 0.1 0.3 0.5 1 2 3 5 10 25 50 100 200 increment
Compatible
The flow rate value and the device status can
be figured out easily via the process data.
PF2M7-L Series p. 4
Over current error, Outside of rated flow
Diagnosis
range, Accumulated flow error, Internal
items product malfunction
A 2 to 200 L/min flow range A rear ported type has A flow adjustment
option has been added. been added. valve (0.05 to 5 L/min)
has been added.
PF2M7(-L) Series
CAT.ES100-127C A
2-Color Display Digital Flow Switch PF2M7(-L) Series
18
foreign matter in contact with the sensor, reducing
sensor accuracy deterioration and damage.
PF2M7
Sensor unit
ght 43
Hei
4.5
Bypass mm PFM7
construction
ter
hor s
IN Air containing moisture or foreign matter OUT
gth
4s.h7orter
Len mm
* There is no bypass construction for the 1 and 2 L ranges. 38.5
9
Reversible display mode 59. 6
64.
* Port size: ø6
When the product is mounted upside down, the
18
orientation of the display can be rotated to make it
easier to read.
OUT IN
A flow adjustment
Reversible display valve is integrated
mode setting
into the product.
OUT IN ¡Space-saving Flow adjustment
valve
design
¡Reduced piping
labor
Piping variations
¡One-touch fitting ¡Female thread
∗ M
ade to order
(Produced upon receipt of order)
Display OFF mode
LEDs can be turned off and checked when necessary.
The product can also be used as a remote sensor.
Mounting
variations
1
2-Color Display Digital Flow Switch PF2M7(-L) Series
The digital display allows for the Select a model according to the fluid
visualization of the flow rate. to be used.
Dry air,
2-color display, Improved visibility Nitrogen
(N2)
Carbon Argon
dioxide (Ar)
(CO2)
T
OU
IN
IDF AR AFM AFD ZF
AF PF2M PF2M
IDU IR AM AMD SFD100
* Recommended air quality class: JIS B 8392-1 1.1.2 to 1.6.2 (ISO 8753-1 1.1.2 to 1.6.2)
Grease-free
value. 4 mA
Display
0% 10% 100% 105%
2
2-Color Display Digital Flow Switch PF2M7(-L) Series
Applications
For the control of metal wire tension For air blow
¡For flow control of N2 gas to
prevent lead frame oxidation
Detection camera
¡N2 blow prevents the
distortion of camera images
due to air turbulence.
Workpiece
Leakage
3
2-Color Display Digital Flow Switch PF2M7(-L) Series
PC *1 IODD File:
IODD is an abbreviation of IO Device
PLC Description. This file is necessary for setting
the device and connecting it to a master. Save
Fieldbus the IODD file on the PC to be used to set the
device prior to use.
Process Data
Application Example
Bit offset Item Note Diagnosis items
0 OUT1 output 0: OFF 1: ON For the predictive maintenance of
· Over current error
1 OUT2 output 0: OFF 1: ON · Outside of rated flow suction verification
range The flow rate “switch ON/OFF signals” and
8 Diagnosis (flow rate) 0: OFF 1: ON
· Accumulated flow “analog values” are monitored to determine
14 Fixed output 0: OFF 1: ON error the suction status. The process and
15 Diagnosis (error) 0: OFF 1: ON · Internal product
suction status can then
malfunction
16 to 31 Measured flow rate value Signed 16 bit be compared.
Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Item Measured flow rate value (PD)
Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Item Error Fixed Reservation Flow rate Reservation OUT2 OUT1
Diagnosis Output Diagnosis Switch output
Start up
Yes At the start of communication
Preoperate
*1 IO-Link Version does The IO-Link version does not match that of the master.
mode not match The master uses version 1.0.
(Flashing)
Abnormal
Communication
Normal communication was not received for 1 s or longer.
disconnection
No
4
Flow Switch Flow Rate Variations
Applicable Detection Rated flow range [L/min]
Series
fluid method −3 −2 −1 −0.5 0 0.5 1 2 3
PFMV 0 0.5
0 1
Thermal 0 3
Dry air
type
N2
(MEMS) −0.5 0.5
−1 1
−3 3
PF2M7(-L) 0.001
0.01 1
L/min
0.02 2
1 100
1 L/min 2 200
PFMB 2 200
Thermal
type 5 500
Dry air (MEMS)
1 L/min
N2
PFG300 Bypass 10 1000
flow type
20 2000
0.5 L/min 5 50
Thermal
Air
— type 1 L/min 10 100
N2
(Thermistor)
2 L/min 20 200
5 L/min 50 500
Thermal
type 5 L/min 60 Body ported type 6000
(Platinum
Air
Body ported type sensor) 10 L/min 120 Body ported type 12000
N2
Bypass
PFG300 1 L/min 10 Modular type 1000
flow type
Modular 2 L/min 20 Modular type 2000
type
5
Flow Switch Variations / Basic Performance Table
PFMV PF2M7(-L) PFMB PFMC(-L) PF2A PF3A7H(-L)
Series
IP65 IP65
IP40 IP40 IP40 IP65
[Monitor unit IP40] [Monitor unit IP40]
Dry air,
Fluid
0.01 to 1
Rated flow range
0.02 to 2 1 to 10
0 to 0.5 −0.5 to 0.5 0.05 to 5 5 to 500 5 to 500 5 to 50 30 to 3000
[L/min]
24 VDC
12 to 24 VDC PF3A7H
12 to 24 VDC ±10%
Power supply
PF2M7 PFMC
±10% ±10% 18 to 30 VDC
voltage
Hysteresis mode: Variable Hysteresis mode: Variable Hysteresis mode: Variable Hysteresis mode: Variable Hysteresis mode: Variable Hysteresis mode: Variable
Window comparator mode: Window comparator mode: Window comparator mode: Window comparator mode: Window comparator mode: Window comparator mode:
Variable Variable Variable Variable Fixed (3 digits) Variable
open collector Accumulated pulse output Accumulated pulse output Accumulated pulse output
Accumulated pulse output open collector
Analog voltage output Analog voltage output Analog voltage output Analog voltage output
Analog voltage output Accumulated pulse output
Analog current output Analog current output Analog current output Analog current output
Analog current output
IO-Link IO-Link IO-Link
2-color 2-color
Display
[Monitor unit 2-color LCD display] 2-color LCD display LED display LCD display 3-color LCD display LED display 3-color LCD display
[Monitor unit 3-color LCD display]
∗ The monitor unit values are for the PFG300 and PFMV3.
6
7
CONTENTS
2-Color Display Digital Flow Switch PF2M7(-L) Series
How to Order.................................................................................................. p. 9
Specifications............................................................................................... p. 11
Flow/Analog Output...................................................................................... p. 13
Dimensions................................................................................................... p. 19
Made to Order.............................................................................................. p. 26
Function Details............................................................................................ p. 27
8
®
PF2M7 Series
How to Order
PF2M 7 10 C6 A M
Integrated display q w e r t y u i
q Rated flow range e Port size Piping variations
01 0.01 to 1 L/min 25 0.2 to 25 L/min Rated flow range With One-touch fitting Female thread
Symbol Port size
02 0.02 to 2 L/min 50 0.5 to 50 L/min 1 2 5 10 25 50 100 200 C4*2, C6, C8, N7 01, 02, N1, N2, F1, F2
05 0.05 to 5 L/min 11 1 to 100 L/min 01 Rc1/8 V V V V V V — — Straight Straight
10 0.1 to 10 L/min 21 2 to 200 L/min N1 NPT1/8 V V V V V V — —
F1 G1/8 V V V V V V — —
w Flow adjustment valve/Piping entry direction 02 Rc1/4 — — — — — — V V
Flow adjustment Piping entry Rated flow range N2 NPT1/4 — — — — — — V V
Symbol
valve direction 1 2 5 10 25 50 100 200 F2 G1/4 — — — — — — V V
Rear ported Rear ported
Nil None Straight V V V V V V V V C4*1 ø4 V V V V — — — —
S Yes Straight — — V V V V V V C6 ø6 V V V V V V — —
L None Rear ported V V V V V V V V C8 ø8 — — — — — — V V
W Yes Rear ported — — V V V V V V N7 ø1/4" — — — — V V V V
∗ 1
and 2 L/min type products are not available with a *1 M
ade to order (Produced upon receipt of
flow adjustment valve. order)
*2 M
ade to order (Produced upon receipt of order)
r Output specification t Option 1
Symbol OUT1 OUT2 Nil W
A NPN NPN Lead wire with connector (2 m) Lead wire with connector (2 m)
B PNP PNP +
Connector cover (Silicone rubber)
C NPN Analog 1 to 5 V ⇔ Analog 0 to 10 V*3
ZS-33-F
D NPN Analog 4 to 20 mA ZS-33-D
E PNP Analog 1 to 5 V ⇔ Analog 0 to 10 V*3
F PNP Analog 4 to 20 mA ZS-33-D +
*3 1
to 5 V or 0 to 10 V can be selected by pressing the button.
The default setting is 1 to 5 V.
* Interchangeable with the * Interchangeable with the
u Option 2 existing PFM7 series existing PFM7 series
Nil R S N
Bracket (For the type without Bracket (For the type with a flow Without lead wire with connector
a flow adjustment valve) adjustment valve)
ZS-33-M ZS-33-MS y Unit specification i Calibration
With 2 With 3 M SI unit only*4 certificate*6
tapping tapping Nil Unit selection function*5 Nil None
screws screws
Without *4 Fixed unit: Instantaneous flow: L/min A Yes
bracket Accumulated flow: L *6 M
ade to order
*5 This product is for overseas use only. The certificate is
(The SI unit type is provided for use in Japan in in both English
accordance with the New Measurement Act.) and Japanese.
The unit can be changed.
* Interchangeable with the Instantaneous flow: L/min ⇔ cfm
existing PFM series * Interchangeable with the existing PFM series Accumulated flow: L ⇔ ft3
T V
Panel mount adapter (For the type Panel mount adapter (For the type
DIN Rail Mounting Bracket (To Be Ordered Separately)
without a flow adjustment valve) with a flow adjustment valve)
ZS-33-2J Panel mount adapter ZS-33-2JS Panel mount adapter S ZS 33 R 3 * Interchangeable with the
existing PFM series
Panel mount Panel mount
adapter B Stations
adapter B
1 1 station
2 2 stations
3 3 stations
Panel Panel 4 4 stations
5 5 stations
Mounting bracket Mounting bracket
DIN rail part number: AXT100-DR-m
* Options are shipped together with the product but do not come assembled. * Refer to page 25 for the DIN rail mounting dimensions.
A 9
2-Color Display Digital Flow Switch RoHS
PF2M7-L Series
How to Order
PF2M 7 10 C6 L M
Integrated q w e r t y u i Made to order
display (Refer to page 26.)
1 2
-
Instantaneous flow [L/min] −0.05 to 1.05 −0.1 to 2.1 −0.25 to 5.25 −0.5 to 10.5 −1.3 to 26.3 −2.5 to 52.5 −5 to 105 −10 to 210
Display range Zero cut-off range 0 to ±10% F.S. (Select per 1% F.S. for the maximum rated flow rate.)
Accumulated flow [L]*13 0.00 to 9999999.99 0.0 to 99999999.9 0 to 999999999
Display LCD, Color: Red/Green, 4 digits, 7 segments
Indicator LED LED ON when switch output is ON (OUT1/2: Orange)
Digital filter*14 Select from 0.05 s, 0.1 s, 0.5 s, 1 s, 2 s, or 5 s.
Enclosure IP40
Environmental
resistance
Withstand voltage 1000 VAC for 1 minute between terminals and housing
Insulation resistance 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Operating temperature range Operating: 0 to 50°C, Stored: −10 to 60°C (No condensation or freezing)
Operating humidity range Operating/Stored: 35 to 85% RH (No condensation or freezing)
Standards CE/UKCA marking, UL (CSA)
Piping One-touch fitting C4 (ø4)/C6 (ø6) C6 (ø6)/N7 (ø1/4") C8 (ø8)/N7 (ø1/4")
Piping*15
specification Screw-in (Rc, NPT, G) 01 (Rc1/8)/N1 (NPT1/8)/F1 (G1/8) 02 (Rc1/4)/N2 (NPT1/4)/F2 (G1/4)
Piping entry direction Straight, Rear
Main materials of parts in contact with fluid PPS, PBT, FKM, Stainless steel 304, Brass (Electroless nickel plating), Si, Au, GE4F
Straight: 40 g Straight: 48 g
One-touch fitting
Rear: 55 g Rear: 63 g
Body
Straight: 60 g Straight: 72 g (G1/4: 117 g)
Screw-in
Rear: 75 g Rear: 87 g (G1/4: 132 g)
Weight
A 11
2-Color Display Digital Flow Switch PF2M7(-L) Series
*1 Refer to the “Recommended pneumatic circuit examples” on page 2. *10 W hen selecting 0 to 10 V, refer to the analog output graph for the allowable
*2 W hen using the accumulated value hold function, use the operating load current.
conditions to calculate the product life, and do not exceed it. The maximum *11 S tandard condition (STD): 20 [°C], 101.3 [kPa] (Absolute pressure),
access limit of the memory device is 3.7 million times. If the product is 65 [% RH] (The flow rate given in the specifications is the value under
operated 24 hours per day, the product life will be as follows: standard conditions.)
• 5 min interval: life is calculated as 5 min x 3.7 million = 18.5 million min = 35 years Normal condition (NOR): 0 [°C], 101.3 [kPa] (Absolute pressure), 0 [% RH]
• 2 min interval: life is calculated as 2 min x 3.7 million = 7.4 million min = 14 years *12 Setting is only possible for models with the unit selection function.
*3 Negative pressure indicates the pressure value on the IN side (inlet side). *13 Power value is displayed for accumulated flow. The first 4 digits of the
*4 When multiple products are installed closely, the upper limit of the power measurement value are always displayed.
supply voltage is 24 VDC. *14 The time for the digital filter can be set to the sensor input. The response
*5 The accuracy value is based on dry air as a fluid. For other fluids, it is a time indicates when the set value is 90% in relation to the step input.
reference value. *15 Check the precautions for One-touch fitting before use. When the piping
*6 Value when the digital filter is set at 0.05 s condition is changed, for example due to piping on the back of the product,
*7 The time from when the instantaneous flow reaches the set value to when use a general purpose fitting (KQmL series). Some piping conditions may
the switch output operates can be set. have negative effects on the flow accuracy.
*8 If the flow fluctuates around the set value, the hysteresis must be set to a * Products with tiny scratches, marks, or display color or brightness variations
value more than the fluctuating width. Otherwise, chattering will occur. which do not affect the performance of the product are verified as conforming
*9 When using a product with an analog output products.
12
PF2M7(-L) Series
200 L/min
2 L/min (100 L/min)
Flow/Analog Output
B
A PF2M701/02/05 C
PF2M725 (-L)
/10/50/11/21(-L)
Voltage output (1 to 5 V) 1V 1.04 V 1.05 V 5V
Current output (4 to 20 mA) 4 mA 4.16 mA 4.19 mA 20 mA
*1 T he analog output current from
F the connected equipment should
E PF2M701/02/05 G be 20 μA or less when selecting
PF2M725 (-L)
/10/50/11/21(-L) 0 to 10 V.
Voltage output (0 to 10 V)*1 0V 0.10 V 0.12 V 10 V When 20 μA or more current
flows, it is possible that the
Output
Output
750 kPa 80
30 70
60
–30 kPa 50 0 kPa
20 0 kPa
40 –30 kPa 750 kPa
–50 kPa 30 –50 kPa 350 kPa
10 –70 kPa 20 –70 kPa
350 kPa
10
0 0
0 20 40 60 80 100 0 50 100 150 200
Flow [L/min] Flow [L/min]
Flow [L/min]
Flow [L/min]
4 8 20
3 350 kPa 6 15
350 kPa
2 4 10
1 750 kPa 2 750 kPa 5 750 kPa
0 0 0
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
Number of needle rotations Number of needle rotations Number of needle rotations
Flow [L/min]
Flow [L/min]
40 80 160
30 60 120
20 40 80 150 kPa
750 kPa 750 kPa
10 20 40
0 0 0
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
Number of needle rotations Number of needle rotations Number of needle rotations
14
PF2M7(-L ) Series
When the PF2M series is used with negative pressure (–70 to 0 kPa), the measurable range (warranty range of the specifications including pressure
characteristics) varies depending on the flow range.
Select the flow range referring to the graph below.
Flow [L/min]
Flow [L/min]
0.7 1.4 3.5
0.6 1.2 3.0
0.5 1.0 2.5
0.4 0.8 2.0
0.3 0.6 1.5
0.2 0.4 1.0
0.1 0.2 0.5
0.0 0.0 0.0
–70
–50
–30
350
750
–70
–50
–30
350
750
–70
–50
–30
350
750
Applied pressure [kPa] Applied pressure [kPa] Applied pressure [kPa]
Flow [L/min]
Flow [L/min]
7.0 17.5 35
6.0 15.0 30
5.0 12.5 25
4.0 10.0 20
3.0 7.5 15
2.0 5.0 10
1.0 2.5 5
0.0 0.0 0
–70
–50
–30
350
750
–70
–50
–30
350
750
–70
–50
–30
350
750
Applied pressure [kPa] Applied pressure [kPa] Applied pressure [kPa]
Flow [L/min]
70 140
60 120
50 100
40 80
30 60
20 40
10 20
0 0
–70
–50
–30
350
750
–70
–50
–30
350
750
15
2-Color Display Digital Flow Switch PF2M7(-L) Series
Load
U
circuit
circuit
Black OUT1 Black OUT1
Load
U
+ +
circuit
circuit
Black OUT1 Black OUT1
Load
Load
12 to 24 VDC 12 to 24 VDC
U
White OUT2 +
− White OUT2 +
−
Load
Load
Main
Main
12 to 24 VDC 12 to 24 VDC
U
Load
Main
Main
U
Load
U
U
circuit
circuit
Black OUT1 Black OUT1
Load
U
+ +
circuit
circuit
Black OUT1 Black OUT1
Load
12 to 24 VDC 12 to 24 VDC
U
Load
Main
Main
12 to 24 VDC 12 to 24 VDC
U
Load
Main
Load
Blue DC (−) Blue DC (−)
Max. applied voltage: 28 V, Max. load current: 80 mA, Max. load current: 80 mA, Internal voltage drop: 1.5 V or less
Internal voltage drop: 1 V or less E: Analog output: 1 to 5 V or 0 to 10 V can be selected.
C: Analog output: 1 to 5 V or 0 to 10 V can be selected. Output impedance: 1 kΩ
Output impedance: 1 kΩ F: Analog output: 4 to 20 mA
D: Analog output: 4 to 20 mA Load impedance: 50 to 600 Ω
Load impedance: 50 to 600 Ω
Blue DC (−)
50 ms 50 ms
50 ms 50 ms
16
PF2M7(-L) Series
Load
U
Main circuit
Main circuit
Black OUT1 Black OUT1
+ +
Load
18 to 30 VDC 18 to 30 VDC
U
Max. applied voltage: 30 V, Max. load current: 80 mA, Max. load current: 80 mA, Internal voltage drop: 1.5 V or less
Internal voltage drop: 1.5 V or less
PF2M7mm-m-L2m-mmm
NPN 2 output type PNP 2 output type
Brown DC (+) Brown DC (+)
Load
U
Main circuit
Main circuit
Black OUT1 Black OUT1
+ +
Load
Load
18 to 30 VDC 18 to 30 VDC
U
Load
U
Max. applied voltage: 30 V, Max. load current: 80 mA, Max. load current: 80 mA, Internal voltage drop: 1.5 V or less
Internal voltage drop: 1.5 V or less
U
Main circuit
Main circuit
Load
18 to 30 VDC 18 to 30 VDC
U
Max. applied voltage: 30 V, Max. load current: 80 mA, Max. load current: 80 mA, Internal voltage drop: 1.5 V or less
Internal voltage drop: 1.5 V or less
PF2M7mm-m-L3/4m-mmm
L3: NPN + Analog voltage output type L3: PNP + Analog voltage output type
L4: NPN + Analog current output type L4: PNP + Analog current output type
Brown DC (+) Brown DC (+)
Load
U
Main circuit
Main circuit
18 to 30 VDC 18 to 30 VDC
U
Load
Max. applied voltage: 30 V, Max. load current: 80 mA, Max. load current: 80 mA, Internal voltage drop: 1.5 V or less
Internal voltage drop: 1.5 V or less L3: Analog output: 1 to 5 V or 0 to 10 V can be selected.
L3: Analog output: 1 to 5 V or 0 to 10 V can be selected. Output impedance: 1 kΩ
Output impedance: 1 kΩ L4: Analog output: 4 to 20 mA
L4: Analog output: 4 to 20 mA Load impedance: 50 to 600 Ω
Load impedance: 50 to 600 Ω
Black C/Q
C/Q
Blue L− L−
17
2-Color Display Digital Flow Switch PF2M7(-L) Series
PF2M701/702/705/710/725/750/711(-L)
w q e r t y u i o r e w
Female thread
!3 !0
!2 !1
w !4
Component Parts
No. Description Material Note
1 Body PPS
2 Fitting for piping Brass Electroless nickel plating
3 O-ring FKM
4 Flow rectifier Stainless steel 304
5 Seal FKM
6 Flow rectifier Stainless steel 304
7 Sensor chip Silicon
8 Body B PPS
9 Printed circuit board GE4F
10 O-ring FKM Fluoro coating
11 Flow adjustment valve body PBT
12 Body Brass Electroless nickel plating
13 Needle Brass Electroless nickel plating
14 O-ring FKM Fluoro coating
15 O-ring FKM Fluoro coating
18
PF2M7(-L) Series
Dimensions
PF2M7m-C4/C6/C8/N7(-L)
A
A
48
48
18 18
OUT1 OUT2
OUT1 OUT2
DC(−) DC(+) 10.2
1.41.4
DC(−) DC(+) 10.2
38.5
(30.9)
38.5
(30.9)
13 13
3 3
2 x One-touch fitting 18 2 x 3.4
Applicable
2 tubing
x One-touch O.D.: ø4, ø6, ø8, ø1/4"
fitting 18 2 x 3.4
Applicable tubing O.D.: ø4, ø6, ø8, ø1/4"
[mm] 28
Model A P 28
PF2M701/702/705/710 59.1 ø2.8 depth 8.4
-C4(-L)
8 8
PF2M7mL-C4/C6/C8/N7(-L) A
A
48
48
18 18
OUT1 OUT2
OUT1 OUT2
DC(−) DC(+) 10.2
1.41.4
3 3
C C
18
IN 18 OUT
2 x One-touch fitting 2 x 3.4
IN 68 OUT
Applicable
2 tubing
x One-touch O.D.: ø4, ø6, ø8, ø1/4"
fitting 2 x 3.4
Applicable tubing O.D.: ø4, ø6, ø8, ø1/4" 68
28
[mm] 28
Model A C P
PF2M701/702/705/710L
8 8
Dimensions
PF2M7m-m1/2(-L) A
48
Width across
flats B
18
OUT1 OUT2
1.4
38.5
(30.9)
13
3
2 x Female thread
Port size: 1, 2 18 2 x 3.4
[mm] 28
Model A B P
PF2M701/702/705/710/ 66 14 ø2.8 depth 8.4
725/750-01(-L)
8
PF2MmL-m1/2(-L) A
48
18
OUT1 OUT2
3
C
18
Dimensions
A
PF2M7mS-C4/C6/C8/N7(-L) A
76
6876
58 68
48 58
48
18 18
OUT1 OUT2
OUT1 OUT2
DC(−) DC(+) 10.2
1.41.4
DC(−) DC(+) 10.2
53.9)
53.9)
(Max.
38.5
(Max.
(30.9)
38.5
46.9
(30.9)
46.9
13 13
3 3
PF2M7mW-C4/C6/C8/N7(-L)
A
D A 58
D 48 58
48
18 18
OUT1 OUT2
OUT1 OUT2
DC(−) DC(+) 10.2
1.41.4
(Max.
(30.9)
38.5
46.9
(30.9)
46.9
3 3
C C
18
2 x One-touch fitting IN 18 OUT
2 x 3.4
Applicable tubing
2 x One-touch O.D.: ø4, ø6, ø8, ø1/4"
fitting IN OUT
2 x 3.4 68
Applicable tubing O.D.: ø4, ø6, ø8, ø1/4" 68
28
[mm]
28
Model A C D P
PF2M705/710W-C4(-L) 86.2 7.6 18.2 ø2.8 depth 8.4
PF2M705/710/725/750W
8 8
21
2-Color Display Digital Flow Switch PF2M7(-L) Series
Dimensions
PF2M7mS-m1/2(-L) A
76
68
58
48
Width across
flats B
18
OUT1 OUT2
1.4
2 x Female thread 3
Port size: 1, 2 18 2 x 3.4
[mm]
Model A B P Q 28 20
PF2M705/710/725/750S 94 14 ø2.8 depth 8.4 ø2.5 depth 6
-01(-L)
PF2M705/710/725/750S
8
PF2M7mW-m1/2(-L) A
D 58
48
18
OUT1 OUT2
3
C
18
2 x Port size Width across flats B IN 2 x 3.4 OUT
Port size: 1, 2 68
[mm]
28
Model A C B D P
PF2M705/710/725/750W 86.2 11 14 18.2 ø2.8 depth 8.4
-01(-L)
PF2M705/710/725/750W
8
Dimensions
PF2M701/702/705/710/725/750/711/721(-L)
Panel mounting/Without flow adjustment valve/Straight With bracket/Without flow adjustment valve
48
36
58 28
29.9
28
34
26
18
4x
3.4
1.4
3
Panel thickness
38.5
38.5
43.5
18
Panel mount adapter/Without flow adjustment valve 1.2
A
58
[mm]
Model A
29.9
28
PF2M701/702/705/710/725/750L-m(-L) 84.4
PF2M711/721L-m(-L) 88
3
54 +0.5
24 +0.5
0
0
34 or more
4 x R3 or less
4 x R3 or less
4 x R3 or less
23
2-Color Display Digital Flow Switch PF2M7(-L) Series
Dimensions
PF2M705/710/725/750/711/721(-L)
Panel mounting/With flow adjustment valve/Straight With bracket/With flow adjustment valve
76
78.0 24 28
29.9
28
34
26
18
4x
3.4
3 36
1.4
3
38.5
43.5
18
1.2
[mm]
Model A
29.9
28
PF2M705/710/725/750W-m(-L) 91.2
PF2M711/721W-m(-L) 93
3
+0.5
74
0
0
34 or more
4 x R3 or less 4 x R3 or less
4 x R3 or less
24
PF2M7(-L) Series
Dimensions
PF2M701/702/705/710/725/750/711/721(-L)
DIN rail mounting bracket
ZS-33-Rm
18 x n pcs. + 33
18
48
38.5
DIN rail
AXT100-DR-m
* For m, enter a number from the No. line in the table below.
L
12.5 5.25 7.5
(Pitch)
(35)
(25)
5.5
1.25
L Dimensions [mm]
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5
25
PF2M7-L Series Compatible Products
Made to Order
Please contact SMC for detailed specifications, delivery times, and prices.
Symbol
Compatible with Argon (Ar) and Carbon Dioxide (CO2) Mixed Gas X731
The argon–carbon dioxide gas ratio (Ar : CO2) can be selected using the push-buttons from among the following: 92 : 8, 90 : 10, 80 : 20, 70 : 30,
60 : 40, 40 : 60, and 30 : 70. The dimensions are the same as those of the standard model.
PF2M 7 L X731
Output specification
7 Integrated display Symbol OUT1 OUT2
L IO-Link/NPN/PNP —
L2 IO-Link/NPN/PNP NPN/PNP/External input For “How to Order,”
L3 IO-Link/NPN/PNP Analog 1 to 5 V ⇔ Analog 0 to 10 V refer to page 10.
L4 IO-Link/NPN/PNP Analog 4 to 20 mA
* Only applicable to the IO-Link output specification
Zero-clear function
The measured flow rate indication can be adjusted to zero.
The adjustment range is ±5% F.S. of the initial factory setting.
27
Function Details PF2M7(-L) Series
Analog free span function
This function allows a flow that generates an output of 5 V (or 10 V when 0 to 10 V is selected) or 20 mA to be changed.
The value can be changed between 10% of the max. value of the rated flow and the max. value of the display range.
ent
pm
f shi nt
eo me
Analog output [V]
0 0
1 10 100 105 1 10 100 105
10% of the rated 100% of the rated Max. value of 10% of the rated 100% of the rated Max. value of
flow range flow range the display range flow range flow range the display range
Flow [L/min] Flow [L/min]
100 L/min type 100 L/min type
System error An internal data error has occurred. Turn the power OFF and turn it ON again.
Version does not The IO-Link version does not match that of the master. Ensure that the master IO-Link version
match*2 The master uses version 1.0. matches the device version.
*1 A decimal point will be displayed depending on the flow range or measurement unit setting.
*2 Only for the IO-Link compatible products
* If the error cannot be solved after the instructions above are performed, please contact SMC for investigation.
Unit display
[STD] turns on. [L] and [/min] turn on. [L] turns on.
At the upper right of the display, the index [x103] or
6
[x10 ] will turn on based on the accumulated flow.
Normal condition (nor) Instantaneous flow unit CFM Accumulated flow unit ft3
[STD] turns off. [L] turns off and [/min] turns on. [L] turns off.
At the upper right of the display, the index [x103] or
6
[x10 ] will turn on based on the accumulated flow.
28
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk which,
Caution: if not avoided, could result in minor or moderate injury.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of risk which,
Warning: if not avoided, could result in death or serious injury.
ISO 10218-1: Manipulating industrial robots – Safety.
etc.
Danger indicates a hazard with a high level of risk which,
Danger : if not avoided, will result in death or serious injury.
Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its The product herein described is basically provided for peaceful use in
specifications. manufacturing industries.
Since the product specified here is used under various operating conditions, If considering using the product in other industries, consult SMC beforehand
its compatibility with specific equipment must be decided by the person who and exchange specifications or a contract if necessary.
designs the equipment or decides its specifications based on necessary If anything is unclear, contact your nearest sales branch.
analysis and test results. The expected performance and safety assurance
of the equipment will be the responsibility of the person who has determined Limited warranty and Disclaimer/
its compatibility with the product. This person should also continuously
review all specifications of the product referring to its latest catalog Compliance Requirements
information, with a view to giving due consideration to any possibility of The product used is subject to the following “Limited warranty and Disclaimer” and
equipment failure when configuring the equipment. “Compliance Requirements”.
Read and accept them before using the product.
2. Only personnel with appropriate training should operate
machinery and equipment. Limited warranty and Disclaimer
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including
1. The warranty period of the product is 1 year in service or 1.5 years after
our products must be performed by an operator who is appropriately trained
the product is delivered, whichever is first.∗2)
and experienced. Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
3. Do not service or attempt to remove product and machinery/ 2. For any failure or damage reported within the warranty period which is clearly our
equipment until safety is confirmed. responsibility, a replacement product or necessary parts will be provided.
1. The inspection and maintenance of machinery/equipment should only be This limited warranty applies only to our product independently, and not to any
performed after measures to prevent falling or runaway of the driven other damage incurred due to the failure of the product.
objects have been confirmed.
3. Prior to using SMC products, please read and understand the warranty terms
2. When the product is to be removed, confirm that the safety measures as and disclaimers noted in the specified catalog for the particular products.
mentioned above are implemented and the power from any appropriate
∗2) Vacuum pads are excluded from this 1 year warranty.
source is cut, and read and understand the specific product precautions
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
of all relevant products carefully. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
3. Before machinery/equipment is restarted, take measures to prevent or failure due to the deterioration of rubber material are not covered by the limited warranty.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of
Compliance Requirements
safety measures if the product is to be used in any of the 1. The use of SMC products with production equipment for the manufacture of
following conditions. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country to another are
outdoors or in a place exposed to direct sunlight. governed by the relevant security laws and regulations of the countries involved
2. Installation on equipment in conjunction with atomic energy, railways, air in the transaction. Prior to the shipment of a SMC product to another country,
navigation, space, shipping, vehicles, military, medical treatment, assure that all local rules governing that export are known and followed.
combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press
applications, safety equipment or other applications unsuitable for the Caution
standard specifications described in the product catalog.
SMC products are not intended for use as instruments for legal
3. An application which could have negative effects on people, property, or metrology.
animals requiring special safety analysis. Measurement instruments that SMC manufactures or sells have not been
4. Use in an interlock circuit, which requires the provision of double interlock qualified by type approval tests relevant to the metrology (measurement) laws
for possible failure by using a mechanical protective function, and of each country. Therefore, SMC products cannot be used for business or
periodical checks to confirm proper operation. certification ordained by the metrology (measurement) laws of each country.
Revision History
Edition B ∗ The PF2M701, 702, and 705 have been added. Edition C ∗ A flow adjustment valve (0.05 to 5 L/min) has been added.
∗ A female thread type has been added. ∗ A 2 to 200 L/min flow range option has been added.
∗ The IO-Link compatible PF2M7-L series has been added. ∗ A rear ported type has been added.
∗ Internal circuits and wiring examples have been revised. ∗ Number of pages has been increased from 28 to 32. ZV
∗ A made-to-order option (Compatible with argon (Ar) and
carbon dioxide (CO2) mixed gas) has been added.
∗ Number of pages has been increased from 20 to 28. YU
Safety Instructions Be sure to read the “Handling Precautions for SMC Products” (M-E03-3) and “Operation Manual” before use.