DJect Code: 59027 / Propram Elective - IlAnalysis and Design of Multi-storcy Buildings

ME Civil Sem I
Marks: 80
Time: 3Hours

N.B:
1. Question No. I iscompulsory the remaining questions.
2. Attempt any Threc questions from
data if required.
3. Assume any suitableindicate full marks.
4. Figurcs to the right is permitted
5. Uscof relcvant IS code 5
structural members.
of high temperature
on different type of 5
effect
Q1. a) What are the
response spectrum mcthod
b) Explain the of concrete with high
temperature
protection against spalling 5
c) What are the
storey drift and soft storey.
d) Explain the term 400mm subjected to the
20

for a column of size 400 mm x based against


Q.2 Design the reinforcement has an unsupported length 4 m and is
the column
following forces. directions, use M25 and Fe 415 Seismic load
side sway in both Dead load
Live Load
400 300
Axial Load (kN) 600 60
40
Moment kN-m 50
20
20 m x 20m height
Grid size 5 m x 5 m and plan dimension medium stiff and it
Q.3 RCCbuilding have in each storey height 3 m. type of soil is
having frame the intensity
of building 12 m
design building with ordinary moment resistinglocated at Mumbai.
isproposed to building is
and imposed 3 kN/m .use M25 and
of dead load 5 kN/mseismic load and the structure static analysis.
Determine the design
Fe 415 20
grid size 4 m x 4m.
dimension 16 m x 16 m and
Aseven storey
building has a plan Cross-section of beam is 300
Q.4 having size 400 mm x 400mm (25nos) acting on floor is 4
The column
height between floor is 3.2 m. dead load hard and
mm x 600 mm The 2kN/m2 on all floor Soil below the foundation is different
KN/m and live load shears at
Mumbai, Determine seismic forces and
building is located in
Fe 415
floor levels. .use M25 and
x 5m 20
x 30m and grid size 5 m
twelve storey building has a plan dimension 30 mprovided in each direction resist
Q.5 A shear wall are to be
height of each storey 3 m. Twoon each shear wall is 7000kN. Maximum shear force
load
the seismic forces. axial 40000kN -m. length of
maximum bending moment at base forces .use M25 and
at base 1500kN and shear wall to resist seismic
m. Design the ductile
shear wall10
Fe 415 10
of in filled frame
diagonal strut method for analysis
Q.6 a) Explain equivalent without opening
1, Infilled wall
2. Infilled wall with opening 10
mechanism of Infilled Frame
b) Explain with sketches failure

34092
Page 1 of 1