Broad Portfolio of Chemistry Reagents

In collaboration with DiaSys, Sysmex offers a comprehensive range of high-quality chemistry reagents for
the JCA-BM6010/C.

Wide range of test profiles supporting comprehensive Cardiac, Lipid, Renal, Diabetes and Liver assessments.

DiaSys Diagnostic Systems has been a leading specialist in the development and manufacturing of
diagnostic system solutions for more than 25 years.

Benefits of DiaSys Reagents:


Stable, ready-to-use liquid reagents
Lengthy on-board and calibration stability
Minimised interferences with Lipid Clearing System
Standardised to International Reference Material/Methods
Barcoded reagents with multi-calibrator and controls for easy handling

5
JCA-BM6010/C Specifications
Model Name Automatic Analyser JCA-BM6010/C
Measurement Principle Colorimetry (Rate/End Point)
Turbidimetric Immunoassay
ISE (Indirect), simultaneous 3 item measurement Na+, K+, Cl–
Throughput Total: Maximum 1200 Tests/Hour
Photometric: Maximum 800 Tests/Hour
ISE: Maximum 600 Tests/Hour
Sample Throughput Rate Maximum 800 Samples/Hour
Maximum 400 Samples/Hour for dedicated HbA1c testing (due to
haemolysis step)
Simultaneous Measurement Maximum 50 assays (53 assays with ISE)
Measurement wavelengths: 340 to 884 nm
Sampling
Sample Tray STT: 84 Sample Positions with in-built Barcode Reader (Class 2 Laser)
CTT: 61 Refrigerated Sample Positions
Lab Automated Sampler Point-in-space Sampling for LAS
Sample Dispensing Volume 1.0 to 25 μL
Dilutions 1:1 to 1:300 (1:1 to 1:200 for HbA1c measurement)
Sensors Liquid-Level Sensor, Clot Sensor
Reagent
Reagent Dispensing 1-3 Part Reagent Capability
Reagent Tray 2 Refrigerated Trays with Built-in Barcode Reader (Class 2 Laser)

Design and specifications may be subject to change without prior notice due to future product development.
45 positions per tray
Reagent Container 20mL, 40mL and 70mL
Reagent Volume/Assay 5 to 300 μL (0.1 μL/step)
Reaction Carousel
Reaction Cuvette Plastic, Light-path length: 10mm
Reaction Volume 80 to 430 μL
Reaction Time 3, 4, 5, 10 and 15 minutes (can be set per assay)
Reaction Temperature 37± 0.5 oC
Reaction Bath Temperature-controlled reaction bath with inert oil
Mixer SSR-Spin Mixer
System
Maintenance Automatic startup and shutdown by timer
Workstation PC, LCD color monitor
Host Interface RS232C
Dimension 1,220 (W) x 850 (D) x 1,108 (H) mm
Weight 450 kg
Laser Label

Sysmex Asia Pacific Pte Ltd Sysmex New Zealand Ltd Sysmex Vietnam Co., Ltd
Tel +65 6221-3629 Fax +65 6221-3687 Tel +64 (9) 630-3554 Tel +84 (8) 3997-9400 Fax +84 (8) 3997-9405
www.sysmex-ap.com www.sysmex.co.nz www.sysmex.com.vn

Sysmex India Pvt. Ltd Sysmex (Thailand) Co., Ltd Sysmex Vietnam Co., Ltd (Hanoi Branch)
Tel +91 (22) 6112-6666 Tel +66 (2) 032-2536 Fax +66 (2) 116-5396 Tel +84 (4) 3776-7020 Fax +84 (4) 3776-7022
www.sysmex.co.in www.sysmex.co.th www.sysmex.com.vn

PT Sysmex Indonesia Sysmex Philippines Inc. Sysmex Australia Pty Ltd


Tel +62 (21) 3002-6688 Fax +62 (21) 3002-6699 Tel +63 (2) 621-2460 Fax +63 (2) 621-2432 Tel +61 (2) 9016-3040
www.sysmex.co.id www.sysmex.com.ph www.sysmex.com.au

Sysmex (Malaysia) Sdn Bhd


Tel +60 (3) 5637-1788 Fax +60 (3) 5637-1688
www.sysmex.com.my

Sysmex is an authorised distributor of JEOL in Asia Pacific Region

SAP/CLINICAL CHEMISTRY/JCA BM-6010C/03022020/V3.0


JCA-BM6010/C
Automated Chemistry Analyser

Optimise Performance.
Achieve Accurate Results.

www.sysmex-ap.com
Superior Performance and Efficiency
Now you can rely on the compact JEOL JCA-BM6010/C Automated Chemistry
Analyser to help you achieve faster turnaround time with better accuracy.

Auto Start-Up: Smart Start / Smart Pause: Automated on-board


haemolysing:
Auto Start-Up ensures the analyser Analyser automatically pauses and
is ready when you step into the restarts sample analysis and barcode Automated on-board haemolysis for
laboratory. readings ensuring continuous loading HbA1c allows for walk-away analysis.
of additional samples.

Simplified HbA1c testing


Improve efficiency of diabetes testing with unique methodology of serial HbA1c and plasma glucose measurement

Measuring of HbA1c Procedure for HbA1c and plasma


2 glucose measurement:
1 Centrifuge the sample
3 5
2 Aspiration of blood cells by
sample probe for HbA1c analysis
1 3 Haemolysis of blood samples in
reaction cuvette
4 Aspiration of plasma by sample
4 probe for glucose analysis
5
5 Reagents are added to the
reaction cuvettes and results are
generated
Measuring of plasma glucose

2
Features of JCA-BM6010/C
ISE Unit
• Indirect simultaneous measurement
of Na+, K+ and Cl– enables up to
30,000 tests each
• Easy-to-replace electrodes improve
operator efficiency
• Efficient washing minimises
crystallisation of electrodes ensuring
reliable results

2
STAT Port
Allows easy loading and barcode identification for urgent samples

2nd Reagent

3
JCA-BM6010/C

Cell Cleansing
• Wide contactless draining nozzle in wash unit
prevents cuvette carryover
• Cell conditioner reduces surface tension during cell
blank measurements for accurate assessment of
samples
• Auto-skip function will be triggered in case of
failure during automatic cell blank

Oil Bath Incubation


• Homogeneous incubation temperature within
reaction carousel enables a stable light path and
ensures reliable data quality
• Inert oil prevents water stains, bubbles and dust;
reducing the need for maintenance

4 Bubbles Dust

Oil
Bath
Cell

LIGHT
PATH

V-Block Probe Wash


Specially designed V-Block performs thorough cleansing
ensuring minimal probe carryover and reduced cross-
contamination between runs

Tray 1st Reagent Tray