0% found this document useful (0 votes)
126 views6 pages

Agitation-Power

This document provides information to calculate the power required to rotate an agitator impeller. It details the blade and liquid properties, including 6 disc-type blades that are 58 inches in diameter. The liquid has a specific gravity of 1.15 and viscosity of 12,000 cP. Using these inputs, the power number is calculated to be 6.78. This corresponds to a shaft horsepower requirement of 199 HP. However, with a motor efficiency of 85%, the minimum motor power needed is 234.1 HP. A commercially available 60 HP motor is insufficient.

Uploaded by

gaming jafar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views6 pages

Agitation-Power

This document provides information to calculate the power required to rotate an agitator impeller. It details the blade and liquid properties, including 6 disc-type blades that are 58 inches in diameter. The liquid has a specific gravity of 1.15 and viscosity of 12,000 cP. Using these inputs, the power number is calculated to be 6.78. This corresponds to a shaft horsepower requirement of 199 HP. However, with a motor efficiency of 85%, the minimum motor power needed is 234.1 HP. A commercially available 60 HP motor is insufficient.

Uploaded by

gaming jafar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

POWER REQUIRED TO ROTATE AN AGITATOR IMPELLER

BLADE DATA
Blade Type Disc-type
Blade Quantities 6
Blade Diameter (D) 58 in
Blade Widht (W) 12 in
Rotational Speed (N) 84 rpm
Blade Angle 45 degree

LIQUID DATA
Liquid Specific Gravity 1.15
Liquid Viscosity 12000 cP

CALCULATION
Power Number (NP) 5.65 (Note 1)
Impeller Reynold Number (NRe) 290
Viscosity Power Factor (fμ) 1.2 (Figure 12.2)
Power Number (NP) 6.78 (Note 2)
Shaft Horsepower (P) 199.0 hp
Motor Efficiency 85%
Minimum Motor Power 234.1 hp
Commercially Available Motor 60 hp

Note:
1. Power number for impeller geometry
2. Power number at process and operating conditions
3. Impeller power requirements are relatively independent of mixing-tank diameter
Input
From graph
Calculated
Selected

nk diameter
Type of blade No of Blades W/D Power Number (NP)
Pitched-blade 4 1/5 1.37
Pitched-blade 6 1/5 1.7
Straight-blade 4 1/6 2.96
Straight-blade 6 1/6 3.86
Disc-type 6 1/5 5.46

Pitched-blade
Straight-blade
Disc-type

Note:
Figure 12.1 above assume fully baffle conditions. For a cylindrical tank, it would require four equally spaced vertical plate-type baffles.
The baffles should extend the full height of the vertical wall of the tank and should be 1/12 to 1/10 the tank diameter in width.
l plate-type baffles.
ter in width.