Service Manual
EAEL&HS Series
CONTENTS
Section 1 Important Notice..1 Section 2 Technical Specifications..2 Section 3 remote controller introductions... 9 Section 4 Electronic Controller introductions.....23 Section 5 The disassembly and the relating attention issues to the part of AUX product......32 Part 1. Indoor unit......32 Part 2. Outdoor unit............34 Section 6 Trouble shooting Guide...37 Section 7 Explosion View...47 Part 1. Indoor Unit..47 Part 2. Outdoor Unit....51 Section 8 Cooling Cycle Diagram...54 Section 9 Wiring Diagram...55 Section 10 Service Record...57
Section 1
Important Notice
This service manual is intended for use by individuals possessing adequate backgrounds of electrical. Electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information. Nor can it assume any liability in connection with its use. The information. Specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label. How to order spare parts To have your order filled promptly and correctly. Please furnish the following information: 1. Model No. with Indoor or outdoor 2. No. in the Explosion View 3. Part Name 4. The quantity you ordered
Section 2
Model No
Technical Specifications
ASW-H09A+09A4/HS2R-IV Indoor Unit A (System A) Indoor Unit B (System B) Heating pump / / / 62 / / 2.5 1.0 2.75 40 2.3 2.4 Outdoor Unit
Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg
Wall mounted model 2.5 1.0 2.75 40 2.3 2.4 1 / 220-240V~/ 50Hz 1060 1070 4.60 4.65 2 250V 10A 21.7 3.15 R407c/700 Rotary
PG165X1C-4DFDE2
1050 1060 4.56 4.60 2 250V 10A 21.7 3.15 R407c/730 Rotary
PG165X1C-4DFDE2
Electrical Data
2.6*350+2.6*400
/ 331*846*901 65
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg Indoor Unit A (System A) 3.2 1.2 3.6 43 2.3 2.4
ASW-H09A+12A4/HS2R-V Indoor Unit B (System B) Heating pump / / / 62 / / 2.5 1.0 2.75 40 2.3 2.4 Outdoor Unit
1 / 220-240V~/ 50Hz 1320 1360 5.74 5.91 2 250V 10A 30.5 3.15 R407c/1100 Rotary
4KS225EBB
970 1070 4.22 4.65 2 250V 10A 21.7 3.15 R407c/980 Rotary
4PS164EAC
Electrical Data
2.6*350+2.6*300
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg Indoor Unit A (System A) 3.2 1.2 3.6 43 2.3 2.4
ASW-H12A+12A4/HS2R-VI Indoor Unit B (System B) Heating pump / / / 62 / / 3.2 1.2 3.6 43 2.3 2.4 Outdoor Unit
1 / 220-240V~/ 50Hz 1270 1360 5.52 5.91 2 250V 10A 30.5 3.15 R407c/1100 Rotary 4KS225EBB 1300/1325 Inner 2*12 Capillary tube
3.0*500+3.0*500 3.0*500+3.0*500
1270 1360 5.52 5.91 2 250V 10A 30.5 3.15 R407c/1100 Rotary 4KS225EBB 1300/1325 Inner 2*12
Electrical Data
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg
ASW-H09A+09A4/EA(L)2R1-I Indoor Unit A (System A) 2.5 1.0 2.75 38 2.6 2.6 1 / 220-240V~/ 50Hz 960 950 4.17 4.13 2 250V 10A 21.7 3.15 R410a/750 Rotary
PA108X1C-4FZDE
Indoor Unit B (System B) Heating pump 2.5 1.0 2.75 38 2.6 2.6
Outdoor Unit
/ / / 62 / /
960 950 4.17 4.13 2 250V 10A 21.7 3.15 R410a/800 Rotary
PA108X1C-4FZDE
Electrical Data
2.6*700+2.6*700
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg
ASW-H09A+12A4/EAL2R1-II Indoor Unit A (System A) 3.2 1.2 3.55 41 2.6 2.6 1 / 220-240V~/ 50Hz 1150 1220 5.0 5.3 2 250V 10A 30.5 3.15 R410a/1100 Rotary PA140X2C-4FT 1160/1200 Inner 2*13 Capillary tube
3.0*900+3.0*1000
Indoor Unit B (System B) Heating pump 2.5 1.0 2.75 38 2.6 2.6
Outdoor Unit
/ / / 62 / /
900 980 3.91 4.26 2 250V 10A 21.7 3.15 R410a /950 Rotary
PA108X1C-4FZDE
Electrical Data
2.6*500+2.6*800
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg
ASW-H12A+12A4/EAL2R1-III Indoor Unit A (System A) 3.2 1.2 3.55 41 2.6 2.6 1 / 220-240V~/ 50Hz 1130 1180 4.91 5.13 2 250V 10A 30.5 3.15 R410a/1150 Rotary ASL135SV-C7LU 1120 Inner 2*13 Capillary tube
3.0*900+3.0*1000 3.0*900+3.0*1000
Indoor Unit B (System B) Heating pump 3.2 1.2 3.55 41 2.6 2.6
Outdoor Unit
/ / / 62 / /
1130 1180 4.91 5.13 2 250V 10A 30.5 3.15 R410a/1150 Rotary ASL135SV-C7LU 1120 Inner 2*13
Electrical Data
Model No Items
Type Cooling Performance Dehumidify Heating Noise level EER Power supply Rated input Rated current Supply cord Starting Current Fuse capacity Refrigerant/Charge Refrigerating System Type Model Compressor Rated input Overload Protector Heat exchanger Expansion device Air Volume Fan System Fan Speed H/M/L/Q Fan type Fan motor output Connection Connecting Pipe Drainage Pipe Suitable area Others Net dimensions (W x H x D) Net weight Gas /Liquid Cooling Heating Cooling Heating Cooling Heating Length Class Cooling Heating kw kg/h kw dB(A) W/W -V-Hz W A m / A A g / / W / Row*Hole Type Specification(mm) m3/h r/min r/min / W OD(mm)*L(mm) OD(mm)*L(mm) m2 mm kg
ASW-12A+12A2/EAL2-III Indoor Unit A (System A) 3.2 1.1 / 41 2.56 2.56 1 / 208-230V~/ 60Hz 1250 / 5.7 / 2 250V 10A 30.5 3.15 R22/1280 Rotary 2P20S236A1G 1235 Outer 2*13 Capillary tube 3.0*1000 520 1180/1050/900/800 / Cross flow 19 3.0*1000 520 1180/1050/900/800 / Cross flow 19
/
Outdoor Unit
/ / / 62 / /
1250 / 5.7 / 2 250V 10A 30.5 3.15 R22/1280 Rotary 2P20S236A1G 1235 Outer 2*13
Electrical Data
Section 3
YK(R)-C/01E
YK(R)-C/02JE
Following function description is according to model of YK R -C/01E.The number in the bracket is to the model of YKR-C/02JE accordingly
Sleeping button Used to set or cancel (press it again) sleep mode operation. Wind direction adjusting button Press the button , the horizontal airflow direction plate can adjust automatically . When you have the desired wind direction . please press it again , the airflow direction plate will stop at the situation . Fan speed selection button Use to select the indoor fan motor speed : Power , High , Low , MuteHM series
AutoHighMidLow series E Temp reducing button Press the button once , the setting temperature drops 1 . Press the button continuously for more than 1 second . the setting temperature drops at the speed of 4/s . the lowest setting temperature is 16 .
9
Temp increasing button Press the button once , the setting temperature increases 1 . Press the button continuously for more than 1 second . the setting temperature increases at the speed of 4/s . the highest setting temperature is 32 . Select button for operation mode Which enables you to select different operation modes . after each pressing , the operation mode will be changed . It shows in the following display .
Remark: Cold wind type has no heating function Cancel button function conformity,accordingly YK(R)-C/01E This button have the function of canceling the timer time . Set button function conformity,accordingly When press the SET button . the function of adjusting clock time or affirming the timer time can be set . Time setting button YK(R)-C/01E These two buttons can adjust clock time and timer time . Press it for 1 to 5 seconds , time display will change at the change at the speed of three times per second (Unit : 10 minute) . After 5 seconds , it will change at the speed of ten times per second (Unit : 10 minute) .
YK(R)-C/02JE
These two buttons can adjust clock time and timer time . Press it for 1 to 5 seconds , time display will change at the change at the speed of two times per second. For 5 to 10 seconds , it will change at the speed of ten times per sec .(Unit : 1 minute). For more than 10 seconds , it will change at the speed of ten times per second too . (Unit : 10 minute) . Timing ON/OFF button Set the Timing mode . After each pressing , the mode will be changed . It shows in the following display .
11 11 ON/OFF button You can start the air-conditioner by pressing this button and stop its operation by pressing it again .
Model of YKR-C/02JE Particular function description as follows Health button Pressing this button , the LCD shows the symbol , the anion emission function of the air conditioner is started . Press the button once again , The symbol disappears , the function is cancelled at the same time. Health button This button have the function of adjusting the time.
10
b. Display
YK(R)-C/01E
YK(R)-C/02JE Following function description is according to model of YKR-C/01E.The number in the bracket is to the model of YKR-C/02JE accordingly Emission display When the remote controller sends correct and effective signal each time, the sign will glitter once. Fan speed display Press the Fan speed selection button ,the fan speed will display. You can select fan speed from Feel , High , Low , Mute HM seriesorAutoHighMidLow series. E Mode display Press the MODE button, it shows the current operation mode. You can select Feel , Cool , Dry , Fan , Heat operation mode .(Cold wind type has no heating display). Temperature display Which displays the setting temperature . In the circulation operation mode ( FEEL and FAN ) , the temperature number dont display. Timer ON/OFF display Which displays the timer states , the timer ON and the timer OFF dont set at the same time. Time display Show the current clock time . New adding display programs of YKR-C/02JE as follows: Swing display Pressing the SWING button to change the swing angle of louver .
Remarks : it is readable to list all of items in the picture , when the mode operates , only most of items display on the remote controller.
AUX Air Conditioner Service manual Press the HEALTH button , can choose anions to emit or stop .
Sleep display This indicate whether the air conditioner is in sleep mode or not.
Remarks : it is readable to list all of items in the picture , when the mode operates , only most of items
c. Application method
Model: YK(R)-C/01E Fix batteries
1. Slide open the cover according the direction indicated by arrowhead. 2. Put into two brand new batteries (7#). position the batteries to right electric poles (+&-). 3. Put back the cover. Make sure to connect the wire to independent power source socket before you use the remote controller. Note: the waste battery shall be disposed properly. Automatic operation mode 1. Press the MODE button. select the automatic operation mode. 2. Press the or button. set the temperature. temperature can be set at 1 difference range from 16-32. button. you can select fan speed. 3. Press the The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. 4. Press the button. the operation indicator is on. the air-conditioner starts to operate the Automatic mode. Press the button again. the air-conditioner stops.
Cooling / Heating operation mode (Cold wind type has no heating function)
1. Press the MODE button. select the Cooling or Heating operation mode. 2. Press or the button. set the temperature. temperature can be set at 1 difference range from 16-32. 3. Press the button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low.
12
4. Press the button. the operation indicator is on. the air-conditioner starts to operate the Cooling or Heating mode. Press the button again. the air-conditioner stops. Circulation operation mode 1. Press the MODE button. select the Circulation operation mode. 2. Press the button. you can select fan speed. The type of HM series: You can select fan speed from High. Low. Mute. The type of E series: You can select fan speed from High. Mid. Low. 3. Press the button. the operation indicator is on. the air-conditioner starts to operate the Circulation mode. Press the button again. the air-conditioner stops. Remark: In the circulation operation mode. to set the temperature is noneffective. Drying operation mode 1. Press the MODE button. select the dry mode operation. 2. Press or the button. set the temperature. temperature can be set at 1 difference range from 16-32. button. the operation indicator is on. the air-conditioner starts to operate the Dry 3. Press the mode. Press the button again. the air-conditioner stops. Remark: The type of HM series: In the dry operation mode. the fan speed goes into MUTE automatically. The type of E series: In the dry operation mode. the fan speed goes into LOW automatically. Clock time setting 1. Pressing the SET button for 3 seconds. the time indicator at present begins to glimmer. 2. Adjust present time through pressing the or button.
3. Pressing the SET button once again. the time setting is finished. Remark: Time can be regulated only after the timing mode is cancelled. Timer setting Set the Timer ON ( It is effective only when the air conditioner is shut off ). 1. Press the TIMER button. select the Timer ON. the remote controller display displays intermittently. 2. Adjust time through pressing the or button.
; ON
3. Press the SET button then. the setting is finished. Set the Timer OFF ( It is effective only when the air conditioner is running ).
13
1. Press the TIMER button. select the Timer OFF. the remote controller display displays intermittently. 2. Adjust time through pressing the or button.
; OFF
3. Press the SET button then. the setting is finished. Remark: The remote controller can be set 24 hours. Sleeping operation mode 1. Press the button. the sleeping indicator light of indoor unit flashes on. 2. After the setting of sleeping mode. the cooling operation enables the set temperature to increase 1 after 1 hour and another 1 automatically after 1 hour. 3. After the setting of sleeping mode. the heating operation enables the set temperature to drop 2 after 1 hour and another 2 automatically after 1 hour. 4. The air-conditioner runs in sleeping mode for 7 hours and stops automatically. Remark: Press the MODE button or ON/OFF button. the remote controller clears sleeping mode away. Model: YK(R)-C/01E Fix batteries
1. Slide open the cover according the direction indicated by arrowhead. 2. Put into two brand new batteries (7#). position the batteries to right electric poles (+&-). 3. Put back the cover. Make sure to connect the wire to independent power source socket before you use the remote controller. Note: the waste battery shall be disposed properly. Automatic operation mode 1. Press the MODE button. select the automatic operation mode. 2. Press the button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. button. the operation indicator is on. the air-conditioner starts to operate the 3. Press the Automatic mode. Press the button again. the air-conditioner stops. Cooling / Heating operation mode (Cold wind type has no heating function) 1. Press the MODE button. select the Cooling or Heating operation mode. 2. Press or the button. set the temperature. temperature can be set at 1 difference range
14
from 16-32. 3. Press the button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. 4. Press the button. the operation indicator is on. the air-conditioner starts to operate the Cooling or Heating mode. Press the button again. the air-conditioner stops. Circulation operation mode 1. Press the MODE button. select the Circulation operation mode. button. you can select fan speed. 2. Press the The type of HM series: You can select fan speed from High. Low. Mute. The type of E series: You can select fan speed from High. Mid. Low. 3. Press the button. the operation indicator is on. the air-conditioner starts to operate the Circulation mode. Press the button again. the air-conditioner stops. Remark: In the circulation operation mode. to set the temperature is noneffective. Drying operation mode 1. Press the MODE button. select the dry mode operation. 2. Press or the button. set the temperature. temperature can be set at 1 difference range from 16-32. 3. Press the button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. 4. Press the button. the operation indicator is on. the air-conditioner starts to operate the Dry mode. Press the button again. the air-conditioner stops. Clock time setting 1. Pressing the CLOCK button for 5 seconds. the time indicator at present begins to glimmer. 2. Adjust present time through pressing the or button.
3. Pressing the CLOCK button once again. the time setting is finished. Remark: Time can be regulated only after the timing mode is cancelled. Timer setting Set the Timer ON ( It is effective only when the air conditioner is shut off ).
15
1. Press the TIMER button. select the Timer ON. the remote controller display displays intermittently. 2. Adjust time through pressing the or button.
; ON
3. Press the TIMER button once again. the Timer ON setting is finished. Set the Timer OFF ( It is effective only when the air conditioner is running ). 1. Press the TIMER button. select the Timer OFF. the remote controller display displays intermittently. 2. Adjust time through pressing the or button.
; OFF
3. Press the TIMER button once again. the Timer OFF setting is finished. Remark: The remote controller can only be set 12 hours. Sleeping operation mode 1. Press the button. the sleeping indicator light of indoor unit flashes on. 2. After the setting of sleeping mode. the cooling operation enables the set temperature to increase 1 after 1 hour and another 1 automatically after 1 hour. 3. After the setting of sleeping mode. the heating operation enables the set temperature to drop 2 after 1 hour and another 2 automatically after 1 hour. 4. The air-conditioner runs in sleeping mode for 7 hours and stops automatically. Remark: Press the MODE button or ON/OFF button. the remote controller clears sleeping mode away.
16
Part 2.
ASW-H09A+12A4/EA(L)2R1-II
+ button
This button can set room temperature. Press it once ,the temperature increases 1 .Press it continuously, the temperature increases at the speed of 4/s. This function is invalid when the appliance at the Fan and Auto mode.
SWING button
Press the button , the horizontal airflow direction plate can adjust automatically. When you have the desired wind direction, please press it again, the airflow direction plate will stop at the situation .
FAN button
Use to select the indoor fan motor speed : Power , High , Low , Mute
Remark : The floor standing type select fan speed only from Low to High .
MODE button
Which enables you to select different operation modes . after each pressing , the operation mode will be changed . It shows in the following display .
button
This button can set room temperature. Press it once ,the temperature decreases 1.Press it continuously, the temperature decreases at the speed of 4 /s. This function is invalid when the appliance at the Fan and Auto mode.
button
You can start the air-conditioner by pressing this button and stop its operation by pressing it again .
17
HEALTH button
Press this button ,the LCD shows the
symbol, the
anion emission function of the air conditioner is started. Press the button once again, The
symbol
SLEEP button
Press this button ,the LCD shows the symbol, the sleeping function of the air conditioner is started.
After 7 hours of setting this function ,the air conditioner will be off automatically. Press the button once again, The symbol disappears, the function is cancelled at the same time.
This function is invalid when the appliance under the Fan mode.
When it displays POWER/QUIET button : Which enables you to select different operation mode , after each pressing , the operation mode will be changed . It shows in the following display .
HUMIDITY button
Only under the mode of Heat and Fan, Press this button once , the LCD shows the symbol, the wetting , the
function of the air conditioner is started. The initial humidity is 60%. Press the + or - button once humidity increases or decreases 5%. The setting range is 30%~60%.
18
TIMER/CLOCK button
Setting the ON/OFF timer time When remote controller is at the on/off state. Press this button .the LCD flickers the
symbol. Press the + - or button to set the timer time. After finishing it. press this button again in 10 seconds to affirm. If the setting time is the same as the current time. this setting is invalid. Press the button once more. The Adjusting the clock time symbol disappears . the function is cancelled at the same time.
Press this button in 5 seconds Under the state of no timer setting .the LCD flickers the symbol. Press the + or-button to set the timer time. After finishing it. press this button again in 10 seconds to affirm. If not. this operation is invalid.
button
This button not only can adjust clock time and the timer time but also can set room humidity. Adjusting clock time and timer time Press it once .the time decreases one minute. Press it for 1 to 3 seconds. time display will decrease at the speed of 2min/s. For 3 to 5 seconds. it will decrease at the speed of 10min/s. For more than 5 seconds. it will decrease at the speed of 10min/s. Setting room temperature and room humidity Press it once .the humidity decreases 5%.
button
You can start the air-conditioner by pressing this button and stop its operation by pressing it again .
19
b. Application method
Fix batteries
1. Slide open the cover according the direction indicated by arrowhead. 2. Put into two brand new batteries (7#). position the batteries to right electric poles (+&-). 3. Put back the cover. Make sure to connect the wire to independent power source socket before you use the remote controller. Note: the waste battery shall be disposed properly. Cooling / Heating operation mode (Cold wind type has no heating function) 1. Press the button. the operation indicator is on. the air-conditioner starts to operate the Cooling or Heating mode. Press the button again. the air-conditioner stops. 2. Press the MODE button. select the Cooling or Heating operation mode. 3. Press + or - the button. set the temperature range from 16 to 32. 3. Press the FAN button. you can select fan speed from Low . Mid . High . Auto . 4. Press the Drying operation mode 1. Press the MODE button. select the dry mode operation. 2. Press + or - the button. set the temperature range from 16 to 32. 3. Press the FAN button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. 4. Press the button. the operation indicator is on. the air-conditioner starts to operate the Dry mode. Press the button again. the air-conditioner stops. Circulation operation mode 1. Press the MODE button. select the Circulation operation mode. 2. Press the FAN button. you can select fan speed. The type of HM series: You can select fan speed from High. Low. Mute. The type of E series: You can select fan speed from High. Mid. Low. 3. Press the button. the operation indicator is on. the air-conditioner starts to operate the Circulation mode.
20
Press the button again. the air-conditioner stops. Remark: In the circulation operation mode. to set the temperature is noneffective. Automatic operation mode 1. Press the MODE button. select the automatic operation mode. 2. Press the FAN button. you can select fan speed. The type of HM series: You can select fan speed from Power. High. Low. Mute. The type of E series: You can select fan speed from Auto. High. Mid. Low. 3. Press the button. the operation indicator is on. the air-conditioner starts to operate the Automatic mode. Press the button again. the air-conditioner stops. Remark: In the automatic operation mode. to set the temperature is noneffective. Clock time setting 1. Pressing the TIMER/CLOCK button for 5 seconds. the time indicator at present begins to glimmer. 2. Adjust present time through pressing the or button.
3. Pressing the TIMER/CLOCK button once again. the time setting is finished. Remark: Time can be regulated only after the timing mode is cancelled. Timer setting Set the Timer ON ( It is effective only when the air conditioner is shut off ). 1. Press the TIMER/CLOCK button. the remote controller display intermittently. 2. Adjust time through pressing the or button.
3. Press the TIMER/CLOCK button once again. the Timer ON setting is finished. Set the Timer OFF ( It is effective only when the air conditioner is running ). intermittently. 1. Press the TIMER/CLOCK button. the remote controller display 2. Adjust time through pressing the or button.
3. Press the TIMER/CLOCK button once again. the Timer OFF setting is finished. Sleeping operation mode 1. Press the SLEEP button. the sleeping indicator light of indoor unit flashes on. 2. After the setting of sleeping mode. the cooling operation enables the set temperature to increase 1 after 1 hour and another 1 automatically after 1 hour. 3. After the setting of sleeping mode. the heating operation enables the set temperature to drop 2 after 1 hour and another 2 automatically after 1 hour. 4. The air-conditioner runs in sleeping mode for 7 hours and stops automatically. Remark: Press the MODE button or ON/OFF button. the remote controller clears sleeping mode away.
21
c. Attention
The remote controller transmits signals to the system. Aim the remote controller towards the receiver on the air-conditioner. The remote controller should be within 8 meters away from the receiver. No obstacles between the remote controller and receiver. Dont drop or throw the remote controller. Dont put the remote controller under the forceful sunrays or heating facilities and other heating sources. Use two 7# batteries. dont use the electric batteries. Take the batteries out of remote controller before stop its using for long. When the noise of transmitting signal cant be heard indoor unit or the transmission symbol on the display screen doesnt flare. batteries need be replaced. If reset phenomenon occurs on pressing the button of the remote controller. the electric quantity is deficient and new batteries need to be substituted.
22
Section 4
1. Automatic operation mode 1.1 When air conditioner is running.it will automatically detect indoor temperature by comparison to standard temperature There with to select operation modeRefrigeration. Heating or dehumidify. (default will be set as 24 ) 1.2 When indoor temperature27.running mode will be cooling. 1.3 When indoor temperature is between 20 and . Dehumidify mode will function always mute . 1.4 When indoor temperature 20.heating mode will function. 1.5 In this mode.wind speed will run as set air input. 1.6 Once a operation mode is selected.the mode will not be changed. If restarted. The mode will be reselected. 1.7 The operation indicator will be illumined after 20 seconds blink(mode judgment will be after 20 seconds). 1.8 This mode has timing function.without sleep function. 2. Refrigeration mode 2.1 In cooling mode.temperature is set between 16 and 32. 2.2 The condition of turning on a compressor is: room temperature set temperature +1 .The condition of turning off is room temperatureset temperature-1 . 2.3 When cooling is operating.after the compressor is started up.it cannt be closed until 3 minutes later.or only by turning off the machine or changing function mode. 2.4 In cooling mode. The freeze prevention function of indoor coil is valid. 2.5 Indoor wind speed is operated by set wind speed. 3. Dehumidify function 3.1 temperature is setted and controlled with between 16~ 32. 3.2 four-way valve is closed. 3.3 running indicator is on 3.4 without sleep function.with timing function. 3.5 wind speed is setted mute. 3.6 have got indoor coil freeze prevention function. 3.7 set temperature as the shot temperature of remote controller. 3.8 while indoor temperature is under 16.dehumidify is invalid. 3.9 when room temperature >= 16. Compressor will work with intermittences. The opening and closing time will depend on t loop and t loop-t set up. When compressor and outside fan are closed. Inside fan will stop running. When t ambient23 T at set up +1.compressor will run for 8min and stop for 3min. T a < t set up +1.compressor will run for 3min and stop for 6min. When t a <23 T at set up +1.compressor will run for 3min and stop for 4min. T a <T set up +1.compressor will run for 3min and stop for 6min.
23
4. Ventilation control function 4.1. At ventilation mode.outdoor unit is always closed. 4.2. indoor fan functions according to set air input.without high power wind. 4.3. vertical air blade operates according to operating requirement of remote control. 4.4. without sleep function.have got timing function. 5. Heating Function 5.1. In heating mode.temperature range is setted between 16 and 32. 5.2. While in heating function.the compressor cannot be closed within the first 3 minutes.Compressor can only be closed by changing function mode or turning off the machine. 5.3. Have got function of compensating temperature for 3. 3 Below measured temperature at air inlet is considered the compared value to set temperature. (The others modes doesn't have this function) 5.4 According to the setting temperature. The condition of compressor working is indoor temperature-3set temperature-1.stoping condition is indoor temperatureset temperature1. When room temperature =set temperature.keeping the original state. 5.5. Blow rest heat energy function: the indoor fan motor will run in the mute model on the condition of indoor coil temperature > 30.the indoor fan motor will turn off when the indoor coil temperature fall to below 30.and residual heating function will last less than 40s.And the four-way valve change in 2min. 5.6. indoor fan motor control 5.6.1. Heating defend cold wind and blow rest heat energy function The wind speed of indoor fan motor can be controlled by T inter- panel. as the following : Compressor working to prevent cold wind. 1) When the T e(evaporator) presents rising state.WhenT e 25. indoor fan motor will turn off. When 25T e30.the indoor fan motor will blow feeble wind model. When 30T e38.the indoor fan motor will be in mute wind model. When T e38.the indoor fan motor will blow setting wind speed. 2) When the T e presents falling state.When T e34. The indoor fan motor will blow setting wind speed; when 28T e34.the indoor fan motor will be in mute wind model. When 23T e28.the inter- fan motor will be in the feeble wind model. When the T e23.the inter- fan will automatically trun off.
Picture1
24
Prevent cold wind function when compressor out of working 1) When T e presents falling state. When T e25.the indoor fan motor will be in feeble wind model. T e25 .the indoor fan motor will trun off. 2) When T e presents rising state. and T e28.the indoor fan motor will be in feeble wind model.T e 28.the indoor fan motor will trun off.
Residual heat function: When the T inter- panel35.indoor fan motor will run in feeble wind model.and when the T interpanel35. The indoor fan motor will shut down.and the residual heat function will be less than 10s. When the T inter-panel < 35 . the indoor fan motor will shut down immediately. 5.6.2 High temperature protection function: 1) When the air conditioner is in heating model.When either of two indoor units T e57.and continues for 10s. The out door fan motor will stop.if the T e64. and continues working for 10s. the compressor will stop.when both of the two indoor units T e52.and last for 3 mins. the air conditioner will return to normal operations. 2) This temperature protection function only works when the temperature sensor is work normal. 5.7 Defrosting operation. When one of AB or CD is defrosting. if the other one is in heating mode. it will turn to defrosting mode immediately; Only when the two compressors meet the condition of finishing defrost can they get back to heating mode. 5.7.1 Entry condition of outdoor temperature sensor: In heating system. T c(condenser)-6. for 2mins. compressor works for more than 50 mins. The defrost interval is more than 50 mins; Compressor continuous operates for 5 mins. If outdoor unit temperature sensor is damaged. every 50 minutes of operation needs a defrosting of 10 minutes. (If power is cut off or the machine is turned off by remote controller. Work time of the compressor will resume time) 5.7.2 Requirement of defrosting(sleeping light twinkle once a second). When begin defrosting. compressor and indoor fan motor stop running. Outdoor fan motor and four-way valve continues operation. After 30s later. four-way valve and outdoor fan both stops running. After another 15 seconds.The
25
compressor starts to work with defrosting mode. When defrosting is finished.the compressor stops running. After 20 minutes. the four-way valve starts operating. After another 20 seconds.until all compressors exit defrosting and get into heating mode. Indoor fan works as cold air protection function. Indoor fan works as cold air protection function. 5.7.3 Condition of ending defrosting operating T outer panel 12 or defrosting time 12min. The compressor first meet condition stops running. until the two compressors meet the conditions. 6. Sleep function6.1 When get to sleep mode.indoor wind speed will turn mute. 6.2 In cooling sleep operate mode.increase the temperature by 1 after 1 hour operation. and increase the temperature by 1 after another 1 hour. Turn it off after 7 hours. Refrigeration sleep operation
Temperature Increase another 1
Increase 1
1h
2h
6.3 In heating sleep operate mode.decrease the temperature by 2 after 1 hour operation. And decrease the temperature by another 2 after 1 hour. Turn it off after 7 hours. Heating operation sleep
Temperature original designed temperature
1h
2h
6.4When the mode selection button is pressed. sleep function get cancelled. 6.5 Valid in cooling and heating mode. When sleep button is pressed. it can enter or exit sleep mode. 6.6 Non-sleep model under automatic modedehumidification and ventilation condition. 7. Timing operation 7.1 Set running time can be as long as 12 hours.under single timing pattern. 7.2 Set-time close down
26
Time of turning off can only be set when the machine is on. It cannt be set when the machine is off. When it comes to the set time. both inside and outside unites stops operation. 7.3 Set time operation Time of turning on can only be set when the machine is off. It cannt be set when the machine is on. When it comes to the set time.Both of the inside and outside unites starts operation. 8. Emergency switch Turn the machine on by pressing the on/off button. The air conditioner control get into automatic operation.and the throttle is automatic. The temperature is designed for 24.wind speed is strong.at the same time the operation indicator flickers once a second. 20 seconds later. it operates according to selected mode. Another press makes it turned down. During this period. remote control signal can be received to operate. 9. Different kinds of protection function 9.1. Temperature control functionoverheating protection. 9.1.1 This function is only valid to heating model.and invalid to other modes. 9.1.2 For two indoor unit with a same outside unit. as long as one of them has a T e 57 for 10 seconds. the outdoor unit is closed. 9.1.3 When the two inter-engines with the same outside engine. at the same time. both have a T e 52.outdoor fan get back to normal operation. 9.1.4 When the T e64 for more than 10 seconds. the compressor stops 9.1.5 When the compressor stops for 3 minutes. if T e<52. it gets back to normal operations. 9.2. Indoor coil freeze prevent function 9.2.1 This function is only at refrigeration and dehumidify modes.and invalid to other modes. 9.2.2 When T e -2 for more than 2 minutes.the compressor should stop running. and indoor fan operates according to designed wind input. 9.2.3 When the compressor stops operation.it cannot be restarted until the indoor coil temperature rise to7 or it's turned off for more than 6 minutes. 9.3 It requires that the compressor cannot be restart within 3 mins after its shutdown(except in the heating function and defrosting function) 9.4 Short circuiting or open circuit protection function of the temperature probe. 9.4.1 After the machine is turned on. when the signal of indoor temperature sensor is tested abnormal. if a heating signal is received. then press start-up to start heating without stopping the machine. If a cooling signal is received. then press start-up to start cooling without stopping the machine. If a dehumidifying signal is received. then press start-up to work for 8 minutes and stop for 3 minutes. to dehumidify with low wind speed. Automatic mold of remote signal is not accepted. and automatic auto key to start up is not valid. At the same time.a strobolamp flickersor a digital pipe to indicate corresponding malfunction. } 9.4.2When the deviation of signal of indoor coil temperature sensor is detected. freeze the prevention function. wind protection and overheat protection function get into masked state. In the heating mode. When compressor is on. delay 30s to open indoor fan. with a set wind speed. When compressor is off.
27
delay 30S to open indoor fan. with a mute wind speed. at the same time malfunctions shown. 9.4.3 When the deviation of T c signal of outdoor coil temperature sensor is detected. strobolamp flickers. and malfunction is indicated. If the remote manipulator signal of heating is received. press heating for 50min.defrosting for 10min.to cycle heating. The rest mode function as usual. 9.5 Indoor PG .motor fault handling After the indoor motor is put on voltage. If the feedback signal is not received within 12 seconds. Then indoor fan will automatically function as low wind. 9.6 Communication malfunction If outdoor motor doesnt receive the signal from indoor unit PCB.correspondent outdoor uinit stops. If indoor unit PCB desnt receive the signal from outdoor unit.it will stops. Strobolamp flickers.display corresponding malfunction.Once a communication malfunction appears.It cannot be automatically recovered. After the trouble is solved.it can only be work by remote controller or pressing the starting up button. 10. Mode Control The function modes of outdoor unit are only three: non-heatcooling. dehumidify. heatinginclude defrost. standbyclosedown and ventilation mode. A. B. and C. D are independent and unaffected to each other. The function mode of the outdoor unit is decided by the priority of the four modes. Once outdoor unit function mode is decided.the other compressor which doesn't fit the function mode would stop For example.One of A. B. or C D firstly coolingdehumidify.then outdoor unit mode will be cooling.if the other machine starts with heating.then heating will not function. Only after refrigeration dehumidify) indoor unit turn to standby or heating can outdoor unit turn to heating mode. 11. Digital Tube Display Function 11.1 In the normal condition of the controller.the digital tube display indicator shows room temperature when the machine is on. If the designed temperature is changed. then the designed temperature is shown. and flickers at a rate of once per second. then return to room temperature after 5 seconds. 11.2 fault indication functionnixie display indicator Failure cause Display mode Indoor&outdoor communication Show "E5" malfunction PG motor feedback of fault Show "E4" T ambient sensor feedback fault Show " E1" T evaporator senor feedback fault Show " E3" T condencer sensor feedback fault Show " E2"
Display priority 1 2 3 4 5
Chart 3 shows the step motor swinging angle of E series conditioners of 9000Btu and12000Btu. the angle between fully open position and complete shutdown hereafter is called omnirange angle. The omnirange angle of E mold is 150. In the operational process of repeating motor. the operational angle is always memorized. repeating motor follows 4 phase 8 beating type of drive. 1. Reset action of first electrify. step motor opens an omnirange angle to its opening direction. then opens an omnirange angle to its closing direction. If in the course encounters starting up.then starting up action immediately. with swing speed 22/ s. 2. When machine is on(with remote control or button pressing). the air blade makes a complete shutdown. then swing an omnirange angle to its opening direction. then back to initial point. While heating.it stays at point 5( chart 3.while refrigeration.then swing back to point 2chart 3. 3. The flap button on remote control can set the air blade to free swing or Manual swing. 4. For free swing. the swing scope of heating is 50.as (chart 3)3-5.for cooling. swing scope is 50. 2-4 in chart.swing speed is 5.5/ s. 5. When the machine is turned on. while remote control set air blade non-swing. swing angle swings to a proper position according to different mode and fix. e.g. :cooling mode is chart 3 position 2. heating mold ischart 3position 5. If it's set as free swing. no matter the fan is open or not. air blade swings within limitation. If the remote control set non-swing. Air blade will stop at the set position. 6. Turn off (by remote control or button pressing).when the inside fan motor stops working.air blade will close by itself. 7. Press the emergency switch to get into automatic mold.air blade works according to cooling mode. If the system selects a certain mode.air blade runs according to the selected mode requirement.
Swinging angle of repeating motor for H series off-set air conditioner 9000Btu and 12000Btu 1. When power is on. the air blade makes a complete shutdown. with a swing rate of 22/ s 2. When machine is on. the air blade makes a complete shutdown. then swing to its initial point. While heating.it stops at point 5( chart 4.while cooling.then swing back to point 2chart 4. 3. The flap button on remote controller can set the air blade to free swing or Manual swing. 4. For free swing. he swing scope of heating is 40.as (chart 43-5.swing scope is 40.as 2-4 in chart.swing rate for 5.5/ S. 5. When the machine is turned on. while remote control set air blade non-swing.swing angle swings to a proper position according to different mode eg:cooling mode is chart 4 position two.heating mold is chart 4position 5. If it's set as free swing. open the fan. air throttle swings within limitation. If the remote manipulator set non-swing. pendulum will stop at the set position. If the fan is not open. then the air blade will not swing. 6. Turn off the machine and when the inside motor stop working.the air blade will close by itself. 7. Press the emergency switch to start automatic mold. When the selected mode start to run. air blade will open. Before this air blade stays on cooling position.
Attached is the electrical resistance for wind speed. Cooling Cooling High R7 Strong R12 Soft wind R9 & power wind heating R9 12K 510 1230 1.2K 1200 1.2K 1100 15K 1.2K 1180 3K 1150 3K 1050 20K 2K 1130 5.1K 1100 5.1K 1000 27K 2.7K 1080 8.2K 1050 8.2K 950 36K 3.6K 1030 12K 1000 12K 900 57K 4.7K 980 20K 950 20K 850 82K 6.2K 930 36K 900 36K 800 150K 7.5K 880 82K 850 82K 750 Notemute wind mode.850rpm in heating mold.800rpm in non-heating mold.
31
Section 5
The disassembly and the relating attention issues to the part of AUX product
Attention: Turn off the air-conditioner and pull out the plug of the power supply before the service. Part 1 Indoor unit: No. Part Operation Process Panel 1) Turn off the air-conditioner and cut off 1 the power supply; 2) Tear the adhesive tape sticking to the panel. 3) Hold the handles at both sides of the panel and push upward to have it slip out; 4) Grasp the both sides of the panel and push upward; 5) Turn the upper board by 90and unload it from the connecting pole carefully; 6) Take out the filter from the right and left side. 7) Screw off the bolts on the electrical box cover and unload the box cover; 8) Screw off the 5 bolts (for 1Hp AC) or 8 bolts (for 1.5Hp AC) on the medium frame; 9) Hold the both sides of the medium frame and open it gently; 10) Turn up the medium frame by about 90; 11) Offload the medium frame once hearing the crack sound;
Remark
32
No. 2
Part Operation Process Electrical 1) Do No. 1 firstly; component 2) Pull out all tie-in connecting with PCB and the temperature sensor. etc.; 3) Screw off the screws and bolts as indicated in the picture. Untie the outdoor units interconnection cord and power supply cord from the terminal of the electrical box. 4) If the main PCB board is loosed by chance. remove it away; Water draining tank 1) Do No.1 and 2 firstly. offload the water drainage soft tube; 2) Offload the water draining tank from chassis and take out the electrical components.
Remark
Evaporator 1) Do No.1 . 2 and 3 firstly; 2) Offload the connecting pipe; 3) Offload the tube clip at the rear; 4) Screw off the bolts at the right and left side; 5) Lift up the evaporator. and draw it out from the indoor unit;
1) Screw off one bolt from the motor cover. and remove the motor cover; 2) Offload the motor from the fan; 3) Offload the fan from bearing;
33
Part 2. Outdoor unit: This chart shows the the dismantlement process of outdoor unit of heat pump model..The only cooling model can refer to this flow:
figure1
figure2
1. Loosen the two bolts on the electrical cover as shown in chart 1) Take down the electrical cover unit. 2. Loosen the two bolts on the 3 fixed wire calmp. loosen the bolt on fixed powerline and communication lines of inside and outside unit. take down the power connecting wire and inside and outside unit communication lines. (as shown in figure 2) 3. The rewiring must strictly follow chart 3.The communication lines of A B systems (including NO. 1 and 2 wires and NO. 3 and 4 wires in a same line) cannot be reversed.
figure3
34
figure4 figure5 figure6 4. Loosen the bolt of fixed Top cover board. as shown in figure 4. take down Top cover board 5. Loosen the bolt of fixed small board. as shown in figure 5. take down the small board. 6. According to the above approach. dismantle the bolts of fixed right side board. large board. Left Side board and air intake fencing components. and take down these parts by turns. as shown in figure
figure7
figure8
figure9
7. As shown in chart 7. dismantle the fixing nut of the axial flow fan bladeright-handed nut. take down axial flow fan 8. Dismantle the bolts of fixed motor and motor holder. takes down the motor and motor holder. as shown in chart 8. 9. As in figure 9.dismantle the nuts of the junction box cover in fixed A. B system compressor. and tip-off connecting wire 1 and 2 from the compressor. 10. As shown in chart 9. dismantle the bolts of the four-way valve coils on fixed system A. B. and tip-off four-way valve coil from four-way valve components. 11. Tip-off the tube temperature sensor from A B capillary assembly. and cut out fixed bandagethis step is only for heat pump model. 12. As in figure 9. dismantle the compressor earth wire (each one for A. B compressorfixed on electrical unit holder. 13. As in figure 9.dismantle the two bolts on the fixed electrical holder.and take down the holder
35
component. 14. As in figure 10.dismantle the four bolts on the fixed partition plate. and take down partition plate 15. Unsolder the 4 welding points shown in chart 11. 16. As shown in chart 12. dismantle condenser assembly. A. B system compressor and valve plate component.
figure10
figure11
figure12
figure13
figure14 17. When reconnecting the connecting pipes of inside and outside unit. please strictly follow chart 14. A system match with A indoor unit.B system match with B indoor unit. Change them is prohibited.
36
Section 6
1. Starting Items to check 1.1 Make sure input voltage must be within the10% range of the nominal voltage. If the operation electric tension exceeds scope.the air conditioner may not working normally. 1.1 Make sure the indoor/outdoor communication connecting wire is correct. This series of unit model have two indoor unit.with a communication cable connected to the outdoor unit. Please connected the indoor and outdoor connecting wire strictly according to the circuit diagram. air conditioning. with different type may use connecting wire of the same specification. Please confirm that the code on connecting terminal of indoor and outdoor connecting wire is the same with the code on connecting wire. otherwise air-condition may not work normally. 1.3. Please confirm the indoor and outdoor unit are linked with power supply(each unit have independent power supply). 1.4. If appear the following cases.it will not be due to malfunction of air-condition No Cases Explanation When the power plug of indoor unit This means the conditioner is on power. Press the insert the socket for the first time. sound on/off button on the remote controller.when the 1 can be heard but the air-condition air conditioner receives the signal. it will work doesn't work. In the cooling mode.room temperature While the air conditioner is turned off. it takes 3 is above the set temperature. minutes delay to restart it. When the air Compressor doesn't work. but the conditioner is reelectrified. it's the same case. 2 indoor fan runs. While compressor delays 3 minutes. the air conditioner can regulate the wind speed in the room according to the set speed. The compressor will not function In the mode of dehumidification.the work state of 3 continuously in the mode of compressor will be controlled automatically dehumidify. according to indoor temperature. When the LED light is on.the air The timer is in a state of timing. and air conditioner does not work. conditioner is in readiness for action. 4 If the timing is cancelled. the air conditioner will get back to work. In the cooling and dehumidification The interval of compressor or the slow-down of mode. it doesn't work continuously. and wind speed is to protect the indoor heat 5 the speed of indoor fan engine slows exchanger from freezing. down. Function. and indoor engine fan electromotor speed reduction One of indoor unit works normally.but One of indoor unit works as cooling or one of indoor unit has no response to dehumidification mode.another one indoor unit 6 signals of remote controller. cannt work as heating mode.The mean is that the indoor unit with heating mode couldnt receive single from remote controlle.
37
2. No power supplyout of work completely-tentative diagnosis 2.1. Check item 1) Does the input voltage is correct 2) Does AC power wires connected correctly 3) Does the output voltage of voltage stabilizer l7805 (ic2) is correct 4) Does between indoor and outdoor unit communication is normal 2.2. Fault diagnosis procedure Note There is according with an outdoor unit and two indoor unit.and a set of PCB. Please check them accordingly.
1 Unplug the indoors and outdoors and re-plug after about 5 seconds 2 Listen if noise from buzzer or not? 3 Check the indoor power wire connection and the fuse are intact or not? 4 The outdoor PC board switched on communication signal or not? 5 Check the indoor/outdoor communication connection normal.or not? 6 Check the primary voltage of transformor 7 Check the transformor is normal or not?
38
8 Air-conditioner starts working after pressing ON/OFF on the remote 10 Normal 11 Check outdoor power connection and compressor 12 Check the AC voltage of PCB board. 13 Signal direction shown on the remote controller. 14 Check the remote error of diagnosis 15 Check the primary voltage of convertor 16 Replace the indoor PCB board 17 Check the transformor is normal or not? 18 LED indicator and digital tube on or not? 19 Check the AC voltage of PCB board 20 Replace the indoor PCB board 21 Replace the outdoor PCB board 22 Check control side voltage of RE1.RE2(fan). RE3. RE4 ( 4-way valve). RE7. RE8. RE9. RE10(Compressor) on the outdoor controller normal or not? 23 Check the connection of compressor. external fan. and 4-way valve 24 Check #21(0V). #42(5V) of IC1 is normal or not? 25 Replace relay 26 Check the output of 7821 and 7805 normal or not? 27 Replace outdoor PCB board 28 Replace 7815 or 7805 3. indoor fan motor out of work NoteEach air conditioner is correspondent with an outdoor unit and two indoor unit.and a set of controller. Please check accordingly. 3.3. check item 1)Does indoor fan motor connected to connector(CN10correctly 2)Does input DC current is correct 3)Does Hall IC of indoor fan motor connected to connector(cn30correctly 4)Does function capacitance of indoor fan electromotor connected to connector(cn40correctly
39
1 Unplug the indoors and outdoors and re-plug after about 5 seconds 2 Judge the LED light is on or not? Does Digital tube shows E4 error code or not? 3 Reference to the previous page about error diagnosis steps 4 Check chip output on the controller is normal or not? 5 Micro-controlled chip error 6 Check the input voltage of the fan motor enough or not 7 PCB error 8 Replace PCB 9 Probe position 10 PCB Cn10 11 Status 12 Normal voltage 13 #2. #3 socket 14 Motor running 15 About A.C 134V-160V 16 Fan motor capacitor disconnected to CN10 17 Fan motor false 18 Replace FAC 19 Fan motor false 20 Replace indoor fan motor
40
4Malfunction of the outer door motor 4.1. Check item 1) Is input voltage normal 2) Is the connecting way of exterior connecting terminal correct 3) Is indoor and outdoor communication normal 4.2. Fault diagnosis procedure NoteEach air conditioner is correspondent with an outdoor unit and two indoor unit.and a set of controller. Please check accordingly. Outdoor unit has two independent sets of systems. with a common fan. There may be cases when one of the systems work well and the other doesn't. and this needs to observe the running of compressor to make a judgment.
1 Unplug the power and re-plug after about 5 seconds 2 Is outdoor controller normal? 3 Is output voltage of relay normal? Socket connection is correc 4 Outdoor unit abnormal 5 Check according to powerless diagnosis part 6 Relay abnormal 7 Replace relay 5. Repeating motor of transmit fan blade is out of work 5.1. Check item 1Input voltage is normal 2Whether step motor reliable tie CN2 5.2. Fault diagnosis procedure
41
1 Unplug the power and re-plug after about 5 seconds 2 Turn on air-conditioner with remote controller. 3 LED and digital tube in the indicator board on or not? 4 Confirm powerless error diagnosis steps normal 5 Air blade moves when press air flow ON 6 Normal 7 Voltage changes between the #35.#36.#37.#38 of the internal chip IC6 (square wave) 8 Chip IC6 error 9 Voltage between IC3: 11~14 of the internal chip ULN2003AFW changes?(square wave) 10 Driver chip IC3(ULN2003AFW) is false. 11 Step motor error 6. No hot wind blown in heating mold.only for heat pump unit). 6.1. Check item 1)Confirm temperature set by remote controller is lower than indoor temperature 2)Whether confirm that indoor PCB is connected to terminal board correctly or not? 6.2. Fault diagnosis procedure
42
1. Re-start in five minutes after all of above problems improved 2. Normal 3. Is the voltage of outdoor chip IC1#42 DC5. 0V? 4. Chip IC1 abnormal 5. Voltage of #15.#16 of outdoor chip IC1 high or not? 6. Chip IC1 abnormal 7. Voltage of the connection points between IC2 #15. #16 and 4-way valve relay (RE3. RE4) low or not? 8. IC 2 abnormal 9. Relay out-put normal or not? 10. Replace IC4 11. Replace relay ( RE3. RE4) 12. Four-way valve or indoor and outdoor communication connection abnormal 13 Check the indoor and outdoor communication connection or replace 4-way valve. 14 Replace PCB 7. Malfunction of remote controller 7.1. Fault diagnosis procedure
1. Take off the battery. re-plug after about 5 seconds 2. LED display mode ON or not? 3. Check according to powerless diagnosis parts 4. Can music be heard when press the ON/OFF? 5. Normal 6. Voltage of battery is lower than 2.5V( remote controller)
43
7. Replace battery 8. Remote LCD display normal 9. LCD display error 10. Press the remote ON/OFF button. transmitting signal shows 11. Replace the button 12. Voltage of remote chip IC1 changes 13. Chip error 14. Voltage of Q1 changes 15. Replace three-electro tube 16. Voltage of Led changes 17. Transmitting error 18. Receiver error 8. PCB Checking 8.1. Pay attention to replacing the parts: 1) Human body takes static electricity.So before repairing and replacing parts.please confirm it's earthed safely. Especially before contacting some microcomputer or integrated circuit.make sure release the static electricity completely(confirm there is earthing loop on the wrist. 2) While working on a platform with electricity on. Please make sure there is a insulating mat and there is no metal chips on it. If any metal chips make contact with the part.it is likely to damage the other parts. 3) Before replacing element cut off the power. If the operation is with electricity on. it may cause a shock. short circuiting or other injuries. 4) During the replacement or repair of parts. please confirm whether electric wire or not on the circuit board surface?position of diode. Because the coarseness of circuit connector may cause the wire and component broken by bending and shaking. 5) Before welding he conductor and the new part. ot shoube be wiped up with emery paper or similar things. Otherwise the wire and part may be oxidized and makes weilding difficult. 6) While welding. please do not use hign powered electric iron for too long time. otherwise parts with low thermal resistance are easy to be broken. 7)The heating energy of Electronics tool iron should be passed on to the whole welded object. otherwise.the welding will not work well. 8)Welding material should be used as little as possible. If too much. material will cause circuit malfunction. 8.2. Process Replace parts according to the following process
44
1 Check the error part 2 Unfix the error part 3 Replace the part 4 Check the performance of new part 5 Service done 8.3. Detail Process No. Malfunction Cut off the power and check the fuse on 1 the PCB Electrify
Cause 1.Over voltage 2.Short circuit of indoor fan motor Check Voltage Rectifier circuit goes wrong 1.Whether have got normal AC voltage Step-down voltage transformer broken on CN9 or not? 2. DC voltage on IC6 Put-inDC12V Put-outDC5V Check voltage Circuit goes wrong 1.Check the control RELAID. RE1. RE2 load of outdoor RE3. RE4. RE5 RE6. electrical units RE7. RE8 goes wrong relay open 0.7V relay off 12V 2. Indoor fan Output voltage of Silicon controlled IC6 Silicon controlled goes wrong. rectifier IC5 is about 134VAC-160VAC
45
46
Section 7
1. Indoor Unit:
Model eg: ASW-H09A4/HS2R-IVA
ASW-H12A4/HS2R-VA ASW-H12A4/HS2R-VIA
Explosion View
47
Parts List No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 Part Name Panel assembly Filter Cover board of electrical unit Cover of medium frame Horizontal air blade Vertical air blade Air blade holder Step motor Through-flow fan Rubber bearing holder Plastic holder for left cruch of evaporator Evaporator assembly chassis Mounting plate Clamp of copper pipe Indoor fan motor Controller box Transformer Indoor sensor Main PC board Evaporator tube sensor Remote manipulator acceptor Temperature control probe holder Receiver board Terminal board Anion generator Signal connection wire 12 Power line Display board Remote controller Quantity 1 2 1 1 1 12 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Remark Depend on the panel style of individual model
48
49
Parts List No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 34 35 36 Part Name Panel assembly Sterilization filter Vitamin C anti-acrid filter Filter Screw cover Cover of medium frame Medium frame Horizontal air blade Vertical air blade Air blade holder Step motor Through-flow fan Rubber bearing holder Plastic holder for left cruch evaporator Evaporator assembly Chassis Mounting plate assembly Clamp of copper pipe Indoot fan motor Cover of indoor fan motor Controller box Transformer Indoor sensor Main PC board Evaporator tube sensor Remote receiver holder Temperature control probe holder Receiver board Terminal board Anion generator Signal connection wire 12 Power line Indicator light seat Display board Remote controller Quantity 1 2 2 2 3 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
50
Optional Correspondent with A. B indoor unit Depend on the panel style of individual model Depend on the panel style of individual model Sense function can be chosen
51
Parts List No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Name Condenser Top cover board Capillary assembly for system B Capillary assembly for system A Compressor connecting line for system A Compressor connecting line for system B Grille assembly Rubber supporter Right-hand board Partition plate Electrical box cover board Compressor discharge tube for system A Compressor air return tube for system A Compressor accessory for system A Compressor capacitor for system A Clamp for capacitor Compressor capacitor for system B Fan motor capacitor Transformer Outdoor controller main board Three sockets terminal board Two sockets terminal board Main board holder Electrical box Compressor for system A Compressor cushion for system A Bolt Small valve for system B Big valve for system B Small valve for system A Big valve for system A Valve plate Chassis assembly Compressor cushion for system B Compressor for system B Compressor air return tube for system B Big gasket Six-angle nut Compressor discharge tube for system B Fan motor holder assembly Compressor accessory for system B
52
Quantity 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 2 1 1 1 1 1 2 5 1 1 3 8 1 1 1 1 1 1 3 1 1 6 6 1 1 1
Rmark
42 43 44 45 46 47 48 49 50
Fan motor Cushion Fan Six-angle nut Steel grille Big panel Handle Left-hand holder plate Small panel
1 1 1 1 1 1 1 1 1
53
Section 8
The following chart shows the schematic circuit of the heat pump model.odd cool model only applies the cooling processwithout four way valve
1 four way valve 2 capillary tube 3 single way valve 4 aux-capillary tube 5 evaporator 6 indoor unit motor 7 outdoor unit 8 compressor 9 liquid valve 10 through flow fan 11 gas valve 12 indoor unit 13 condenser 14 outdoor motor 15 axial flow fan
54
Section 9
Applicable to HS \E 1. Indoor Unit
Wiring Diagram
Auto Button
Controlling Panel
A B
Overcurrent Protector
Overcurrent Protector
A
55
56
3. Wiring diagram for Original Multi type a. Indoor unit Wiring diagram
57
Section 10
Date Page Part
Service Record
Cause Report
57