Neo Backer Rod

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

NEO BACKER ROD

Closed cell polyethylene backing rod range

USES
DESIGN CRITERIA
• Expansion joints between all common building NEO BACKER ROD should always be installed into a joint under
materials compression to ensure that applying the joint sealant will not
• As a bond breaker/joint profile former to support displace the foam. This is achieved by compressing
elastomeric sealants NEO BACKER ROD by 25% when installing into a joint (or by
using foam 1/3 larger than the joint size). As a guide, use sizes
ADVANTAGES noted on the chart below:
NEO BACKER ROD diameter selection guide:
• Compatible with all elastomeric sealants
• Readily compressible NEO BACKER ROD diameter
Joint width
• Low load transfer
• Non gassing 4 to 5 mm 6 mm
• No water absorption
• CFC free 6 to 8 mm 10 mm
Technical Data Sheet

DESCRIPTION 9 to 11 mm 13 mm
NEO BACKER ROD is a closed cell polyethylene foam rod
supplied in circular section cords of varying diameters. NEO 12 to 13 mm 15 mm
BACKER ROD is primarily used in expansion joints but is also
suitable for use in any joint system requiring readily 14 to 17 mm 20 mm
compressible joint filler containing no migratory chemicals
which could adversely affect joint sealants.
18 to 20 mm 25 mm
STANDARDS / PROPERTIES :
Meets : ASTM D 5249 , ASTM C 1330 , ASTM D570 21 to 27 mm 30 mm
ASTM D1622-1667 , ASTM 1016,1623, ASTM D792
28 to 35 mm 40 mm
Data quoted are typical for this product, but do not
constitute a specification. 36 to 45 mm 50 mm

60 mm
Form: Cross linked, compressible, 46 to 53 mm
closed cell foam ro d ASTM C 1330 54 to 61 mm 70 mm

Colour: White 62 to 70mm 80 mm

Weathering test: No disintegration


Negligible by volume
(0.03-0.06 mg/cm2 ) ASTMD-570 Sealant depth must be a minimum of 6 mm at the thinnest
Water absorption:
section of the sealant bead (above the center of the NEO
Effects of fire: Being a thermoplastic material,
BACKER ROD), with a minimum bonding depth at the joint face
NEO BACKER ROD will melt. It
of 6 mm on smooth glass and metal surfaces, and 12 mm on
is combustible but rate of flame
spread will be reduced when porous or rough surfaces. For larger joints, the depth of the
confined within a joint joint face should normally be half the joint width. For any
systems with dimensions not meeting these requirements
Nominal density: 28-40 kg/m3-ASTMD-792, ASTM D 1622-1667 consult your sales person.

Tensile Strength : 50 PSI ( 345 KPA ) ASTM C 1016-1623 APPLICATION INSTRUCTIONS

Temprature Range : -90ºF to 210ºF


APPLICATION
Compression Recovery : > 98% ASTM D5249 When used as an expansion or isolation joint filler, NEO
BACKER ROD should be positioned to provide for a surface
sealing slot of required dimensions, ensuring that the
sealing slot is free from mortar droppings, slurry, etc.
When used as a backing strip, NEO BACKER ROD is
simply push fitted back into the joint. The cord diameter
used should be 20 to 30% greater than the joint width.

SHERIDAN SPECIALIZED PRODUCTS


SH
TEL # 06-5679000 / 06-5311621 FAX # 06-5311618 , E-mail # [email protected]
NEO BACKER ROD
Closed cell polyethylene backing rod range

The circular section of NEO BACKER ROD provides a


ESTIMATING
convex face to ensure that applied elastomeric sealants are
PACKAGING
given optimum shape for minimum strain as the joint
moves. Do not use sharp objects when fitting NEO Available in the following sizes and roll lengths:
BACKER ROD, as any damage to joint backing may
Size Metres per roll
allow air voids to be formed in sealant.
250
6 mm
Note: Correct fitting will result in an oval cross section,
800
with depth of NEO BACKER ROD being greater than the 10 mm
nominal joint width, so care must be taken to ensure that
correct sealant dimensions are maintained after fitting 15 mm 360
NEO BACKER ROD
20 mm 200
ROADS, BRIDGES, ROOF JOINTS
Technical Data Sheet

25 mm 100
NEO BACKER ROD is used as a backing strip for non-
traffic-bearing expansion joints.
EXTERNAL WALLING AND CLADDING 30 mm 100

NEO BACKER ROD is used as a backing strip for


expansion joints, as a gap filler for any open joints prior to Other sizes may be available upon application.
application of any cold applied joint sealant and as a
readily compressible, low load transfer joint filler in joints LIMITATIONS
surrounding brick infill panel walling. NEO BACKER ROD, as with other foam backing rods, is
not suitable for use with hot pour sealants. Applications
INTERNAL FINISHES where joint backing must provide continual support for
Expand foam is used as a gap filler and backing strip the joint sealant e.g. water retaining structures or floor
to provide support to sealants in partition joints and joints subject to traffic, Hydrocele, semi rigid filler should
around work tops, baths and other internal finishes and be used.
fittings.

MARKETED BY : MADE IN : KSA

SHERIDAN SPECIALIZED PRODUCTS


SH
TEL # 06-5679000 / 06-5311621 FAX # 06-5311618 , E-mail # [email protected]