RA100Z Ficha Técnica

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Select Series

Mounting Base
Options
System Sensor mounting bases and kits provide a variety
of installation options for detectors in any application.

Features To meet local code and application requirements,


System Sensor offers standard 4" and 6" bases, as well as,
• Bases enable quick and secure detector plug-in
specialty base designs including relay, isolator, sounder and low
• SEMS screws provide easy wiring connection frequency sounder options for Select Series detectors.
• Support for 12-24 AWG provides installation flexibility The standard 4" and 6" bases offer a plug-in detector base intended
for use in intelligent systems, with screw terminals provided for power
• Multiple base formats meet application requirements
(+ and –), and remote annunciator connections. Communication
• Standard white color with ivory and black options takes place over the power (+ and –) lines. The 4" base offers a
• UL 268 compliant compact design while the 6" base provides compatibility with a wider
range of junction boxes.
• M
 echanical locking feature restricts removal of attached sensor
The Select Series specialty bases support application driven
head
requirements. The bases employ a separate mounting plate
that installs on various junction box sizes to eliminate unsightly
Specialty Base Features surface-mount boxes. The mounting plate enables pre-wiring of all
• Pre-wired mounting plate simplifies installation connections to speed and simplify installation.
• Application driven feature sets Relay bases (B224RB-WH/B224RB-IV) provide one form C contact
relay for control of auxiliary functions, such as door closure and
• Sounder bases both UL 268 and UL 464 compliant
elevator recall. The relay can operate in two different modes (short
and long delay). The activation time for the short delay is 60 ms to
100 ms, while the activation time for the long delay is 6 sec to 10 sec.
A shunt with pin headers, located on the base PC board, is used to
set the delay timing.
Isolator bases (B224BI-WH/B224BI-IV) allow the Signaling Line
Circuit (SLC) loop to operate under fault conditions created from a
short circuit preventing an entire communication loop from being
disabled. The base isolates the section of the loop containing the
short circuit from the remainder of the circuit and automatically
restores when the fault is corrected.
The Select Series sounder and low frequency sounder bases
Agency Listings
are designed for new and existing dwelling unit applications.
They offer maximum flexibility in installation, configuration, and
operation to meet or exceed UL 268 and UL 464 requirements. The

3062622 4" & 6" bases: 7300-1653:0109


S911
Relay & Isolator bases: 7300-1653:0126 Consult your fire alarm control panel manufacturer for compatibility
†
Sounder bases: 7135-1653:0213
Low-frequency bases: 7300-1653:0238
with the addressable model of the sounder base.
SPDS901-00 • 04/04/2018 • Page 1
Select Series low frequency sounder bases select one of two B501-supported tones of volume (75 or 85 dBA), tone (ANSI
are designed to meet the NFPA 72 sleeping (ANSI Temporal 3 or Continuous) through a Temporal 3, ANSI Temporal 4 or March Time)
space requirement to produce a fundamental jumper. and group. In addition, some FACPs will
frequency of 520 Hz +/- 10% with a square The B200S sounder and LF sounder bases enable custom tone patterns. The B200S
wave or its equivalent. Studies show that a (B200S-WH/B200S-IV/B200S-LF-WH/ series sounder bases recognize the System
lower frequency, centered around 520 Hz, is B200S-LF-IV) adopt the same address as Sensor synchronization protocol. This
the most ideal to wake sleeping occupants, the detector, but use a unique device type enables it to be used as a component of
even those with mild to severe hearing loss. on the loop. The Fire Alarm Control Panel the general evacuation signal — along with
The B200SR sounder and LF sounder bases (FACP) can use that address to command other System Sensor AV appliances — when
(B200SR-WH/B200SR-IV/B200SR-LF-WH/ an individual sounder — or a group of connected to a power supply or FACP output
B200SR-LF-IV) are fully compatible with sounders — to activate. The command set capable of generating the System Sensor
existing B501BH-Series sounder base from the FACP can be tailored to multiple synchronization pulses.
installations. The device enables users to event-driven tone outputs allowing selection

Specifications – Select Series Bases


Physical Specifications
Diameter B501-WHITE, B501-IV, B501-BL: 4.0" (10.2 cm)
B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF-IV: 6.85"
(17.4 cm)
B300-6, B300-6-IV: 6.1" (155 mm)
B224BI-WH, B224BI-IV, B224RB-WH, B224RB-IV: 6.85" (17.4 cm)
Base Height B501-WHITE, B501-IV, B501-BL: 0.74" (18.8 mm)
(without sensor) B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF-IV: 1.6" (4.1
cm)
B300-6, B300-6-IV: 0.76" (19 mm)
B224BI-WH, B224BI-IV, B224RB-WH, B224RB-IV: 1.61" (4.1 cm)
Weight: B501-WHITE 0.32 lb (145 gm)
B200S-WH, B200S-IV, B200SR-WH, B200SR-IV: 0.50 lb (227 gm)
B200S-LF-WH, B200S-LF-IV, B200SR-LF-WH, B200SR-LF-IV: Weight: 0.6 lb (272 gm)
B300-6, B300-6-IV: 0.32 lb (145 gm)
B224RB-WH, B224RB-IV, B224BI-WH, B224BI-IV 0.50 lb (227 gm)
Wire Gauge B501-WHITE, B501-IV, B501-BL, B224BI-WH, B224BI-IV, B224RB-WH, B224RB-IV, B300-6, B300-6-IV: 18 AWG (0.823
mm²) to 12 AWG (3.31 mm²)
B200S-WH, B200S-IV, B200S-LF-WH, B200S-LF-IV, B200SR-WH, B200SR-IV, B200SR-LF-WH, B200SR-LF-IV: 14 AWG
to 12 AWG
Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at
systemsensor.com
Humidity Range 10% to 93% RH non-condensing

Electrical Specifications: Electrical Specifications:


B501-WHITE, B501-IV, B501-BL (Includes base and detector) B224RB-WH, B22RB-IV
Operating Voltage 15 to 32 VDC Operating Voltage 15 to 32 VDC
Standby Current 150 µA Standby Current 170 µA max.
Set Time Position 1, Short Delay: 60 to 100 ms
Position 2, Long Delay: 6 to 10 sec
Electrical Specifications: Reset Time 20 ms max.
B300-6, B300-6-IV Relay 2 coil latching relay
Operating Voltage 15 to 32 VDC Characteristics 1 Form C contact
UL/ULC Rating:
Standby Current 170 µA max.
CURRENT MAXIMUM LOAD APPLICATION
RATING VOLTAGE DESCRIPTION
Electrical Specifications: 2A 25 VAC PF = 0.35 Non-coded
B224BI-WH, B22BI-IV 3A 30 VDC Resistive Non-coded
Operating Voltage 15 to 32 VDC 2A 30 VDC Resistive Coded
Standby Current 450 µA max. 0.46 A 30 VDC (L/R = 20ms) Non-coded
Isolation Current 15 mA max 0.7 A 70.7 VAC PF = 0.35 Non-coded
0.9 A 125 VDC Resistive Non-coded
0.5 A 125 VAC PF = 0.75 Non-coded
0.3 A 125 VAC PF = 0.35 Non-coded

SPDS901-00 • 04/04/2018 • Page 2


Electrical Specifications: Electrical Specifications:
B200S-WH, B200S-IV B200S-LF-WH, B200S-LF-IV
External Supply Electrical Ratings External Supply Electrical Ratings
External Supply 16 to 33 VDC (VFWR) External Supply 16 to 33 VDC (VFWR)
Voltage Voltage
Standby Current: 500 μA maximum Standby Current: 550 μA maximum VDC
Alarm Current: 35 mA maximum (at high volume setting); Alarm Current, High-volume setting
15 mA maximum (at low volume setting) 70 mA maximum @ 33.0 VDC
SLC Electrical Ratings 90 mA maximum @ 24.0 VDC
SLC Operating 15 to 32 VDC 140 mA maximum @16.0 VDC
Voltage: Alarm Current, Low-volume setting
SLC Standby 300 μA maximum 15 mA maximum @ 33.0 VDC
Current: 20 mA maximum @ 24.0 VDC
Sound Output 25 mA maximum @ 16.0 VDC
High Volume: Greater than 85 dBA minimum measured in SLC Electrical Ratings
a UL reverberant room at 10 feet, 24 Volts (in SLC Operating 15 to 32 VDC
continuous tone) Voltage:
Low Volume: Greater than 75 dBA minimum measured in SLC Standby 300 μA maximum (base only, refer to
a UL reverberant room at 10 feet, 24 Volts (in Current: applicable sensor specification)
continuous tone) Sound Output
High Volume: Greater than 85 dBA minimum measured in
a UL reverberant room at 10 feet, 24 Volts (in
continuous tone)
Low Volume: Greater than 75 dBA minimum measured in
a UL reverberant room at 10 feet, 24 Volts (in
continuous tone)

Electrical Specifications: Electrical Specifications:


B200SR-WH, B200SR-IV B200SR-LF-WH, B200SR-LF-IV
External Supply Electrical Ratings External Supply Electrical Ratings
External Supply 16 to 33 VDC (VFWR) External Supply 16 to 33 VDC (VFWR)
Voltage Voltage
Standby Current: 500 μA maximum Standby Current: 1 mA maximum VDC
Alarm Current: 35 mA maximum Alarm Current 65 mA maximum @ 33.0 VDC
SLC Electrical Ratings 90 mA maximum @ 24.0 VDC
125 mA maximum @16.0 VDC
SLC Operating 15 to 32 VDC
Voltage: SLC Electrical Ratings
SLC Standby 300 μA maximum SLC Operating 15 to 32 VDC
Current: Voltage:
Sound Output Greater than 85 dBA minimum measured in SLC Standby Refer to applicable sensor specification.
a UL reverberant room at 10 feet, 24 Volts (in Current:
continuous tone) Sound Output Greater than 85 dBA minimum measured in
a UL reverberant room at 10 feet, 24 Volts (in
continuous tone)

SPDS901-00 • 04/04/2018 • Page 3


Select Series Junction Box Selection Guide
4"
Single Double 3.5" 4" 4" Square 50 60 70 75
Model Gang Gang Octagonal Octagonal Square with mud ring* mm mm mm mm
B501-WHITE, B501-IV, No No Yes No No Yes Yes Yes Yes No
B501-BL
B200S-WH, B200S-IV,
B200S-LF-WH, B200S-LF-IV,
B200SR-WH, B200SR-IV, Yes Yes Yes Yes Yes Yes No No No No
B200SR-LF-WH,
B200SR-LF-IV
B300-6, B300-6-IV Yes No Yes Yes Yes Yes No No No No
B224BI-WH, B224BI-IV Yes Yes Yes Yes Yes Yes No No No No
B224RB-WH, B224RB-IV Yes Yes Yes Yes Yes Yes No No No No
* with 3.0" mud ring
Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations.

Ordering Information
Model Description
White Ivory Black
B501-WHITE B501-IV B501-BL 4" Flangeless mounting base Accessories
B501-WHITE-BP — — 4" Flangeless mounting base bulk pack,
white
B300-6 B300-6-IV — 6" Flanged mounting base RA100Z
B300-6-BP — — 6" Flanged mounting base bulk pack, Remote LED
white Annunciator
B200S-WH B200S-IV — Intelligent addressable sounder base
B200S-LF-WH B200S-LF-IV — Intelligent addressable sounder base,
low-frequency
B200SR-WH B200SR-IV — Standard sounder base (compatible with
B501BH series)
B200SR-LF-WH B200SR-LF-IV — Low-frequency sounder base (compatible
with B501BH series) CK300-BL
B224BI-WH B224BI-IV — Isolator base Color Kit
B224RB-WH B224RB-IV — Relay base

Related Accessories
White Ivory Black
CK300 CK300-IV CK300-BL Color kit (includes cover and trim ring)
CK300-IR CK300-IR-IV CK300-IR-BL PTIR Color kit (includes cover and trim
ring)
TR300 TR300-IV — Trim ring
— SMB600 Surface mounting kit (flanged), ivory
RA100Z — — Remote LED annunciator TR300
M02-04-00 Detector test magnet Trim Ring
M02-09-00 Test magnet with telescoping handle

3825 Ohio Avenue • St. Charles, IL 60174 ©2018 System Sensor.


Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensor.com
for current product information, including the latest version of this data sheet.
www.systemsensor.com SPDS901-00 • 04/04/2018