0% found this document useful (0 votes)
34 views7 pages

Pilecap Design

The document summarizes the design of a pile cap to support a column load of 1792 kips. It is determined that 5 piles with a diameter of 2.62 feet are needed to support the load, with the pile cap having dimensions of 16.25 feet by 11.25 feet and a thickness of 4 feet. Punching shear and one-way shear checks are performed and satisfy code requirements. The moment demand is calculated as 3913.99 kip-feet, and the reinforcement is designed with 37-25mm bars in the main direction and 25-25mm bars for temperature and shrinkage.

Uploaded by

Engr Zin Myo Min
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views7 pages

Pilecap Design

The document summarizes the design of a pile cap to support a column load of 1792 kips. It is determined that 5 piles with a diameter of 2.62 feet are needed to support the load, with the pile cap having dimensions of 16.25 feet by 11.25 feet and a thickness of 4 feet. Punching shear and one-way shear checks are performed and satisfy code requirements. The moment demand is calculated as 3913.99 kip-feet, and the reinforcement is designed with 37-25mm bars in the main direction and 25-25mm bars for temperature and shrinkage.

Uploaded by

Engr Zin Myo Min
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 7

PILECAP DESIGN

- Allowable pile capacity = 387.3 Kip

- Unfactored load, Pn = 1792.0 Kip

Pn = DL + LL

LL = 100 psf
C 48" x 48"

6.25ft
4 ft

2.62ft Dia Pile

2.5ft 7.5 ft 2.5ft

(I) Effective Pile Capacity

Rpe = Rpa - Wp

Assume 4.0 ft thickness pilecap

Rpe = 387.25 Kip - 27.34 Kip

= 359.91 Kip

(II) To find number of pile required for column load

N = ( Pn / Rpe )

= 4.98

Use 5nos - 2.62ft diameter pile.

(III) Pilecap size and shape

For 5nos cap ; Pile c/c spacing = √2 k ( k = c/c spacing with 3dp )

= 11.14ft ~ 11.25ft

48 in 2.5 ft

16.25 ft 11.25 ft

(c+d)
(c+d) 2.5 ft

(IV) To find thickness of pilecap

Punching shear

fc ' = 3000 psi

fy = 50000 psi

d = h - cover ( cover = 8.5 in )

= 39.50 in

d/2 = 19.75 in

Column face to pile interior end = 27.75 in

Column face to pile exterior end = 59.25 in

Punching shear force 4Rup = 4 x 1.5 x 359.91 Kip

= 2159.4 Kip

Failure line length bo = 4 (c+d) = 350.0 in

Punching shear , ØVcp = 4 Ø √fc' bo d (Ø=0.85)

= 2574.6 Kip > 2159.4 Kip (OK)

(V) Checked one-way shear at distance 'd'


one-way shear
failure line
(d)
39.5 in

19.7 in

1.5 x 359.91 Kip


One-way shear force, Vuo = 2 x x 19.7 in = 677.0 Kip
31.496062992126

b = 16.3 ft = 195.0 in
Concrete resisting one-way shear, ØVco = 2 Ø √fc' bo d (Ø=0.85)

= 717.2 Kip > 677.0 Kip (OK)

(VI) To find Moment and Reinforcement

3.63 ft

1.5Rpe

Mu = 2nos x 539.86 kip x 3.63 ft = 3913.99 k-ft

b = 195.0 in

ρmax = 0.75 ρb

= 0.75 x 0.85 β1 (fc'/fy) [87000/(87000+fy)]

= 0.02065

= 2.06 %

ρact = (ρmax/2) = 0.01032 = 1.03 %

ØMn = Ø ρ fy b d2 ( 1 - 0.59 ρ fy/fc' )

d = 24.0 in

Use, d = 39.5 in

Use, H = 48.0 in

Mu
As =
Ø fy ( d - a/2)

Assume a = 6 in

As = 28.60 sq-in

Check a = 2.88 in
As = 27.42 sq-in

Checked minimum reinforcement (As,min)

As,(min) = 0.0024 b h (BS 8110)

= 0.0015 b h (CP 114)

= (200/fy) b d (ACI)

= 0.004 b d (ACI)

Use As,min = 0.002 b h

= 18.72 sq-in

Choose 25 mm bar ; Ab = 0.761 sq-in

N = 36.04

Use 37 - 25 mm both direction. (Main Bar)

Choose 25 mm bar ; Ab = 0.761 sq-in

N = 24.60

Use 25 - 25 mm both direction. (Temperature & shrinkage bar)


(OK)
(OK)