CXT-IR Infrared LEL PDS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

®

SmartWireless
Model CXT-IR
detcon inc. Infrared LEL Gas Detection Sensor Assemby
GAS DETECTION SENSORS INTEGRATED CONTROL SYSTEMS SMARTWIRELESS® PIPELINE ANALYZERS ALARMS

Description
Detcon Model CXT-IR SmartWireless® gas detection sensors are easily and economically
deployable in both permanent and temporary installations. This low power sensor assembly
utilizes infrared technology for combustible hydrocarbons. All component parts are rated
for Class 1; Division 1, Groups C, D hazardous areas. This advanced field device consists of
a Detcon Model Series CXT low power infrared gas detection sensor, and wireless trans-
ceiver packaged in a single enclosure. Power is provided by a disposable battery pack capable
of continuous operation for greater than 60 days. An optional rechargeable battery pack
allows for 5 months operation. Solar power options allow for indefinite operation. An
optional disposable “D” cell battery pack is capable of delivering up to 9 months operation.

Detcon’s proprietary “Self Healing Mesh” technology operates at 2.4 GHZ and conforms
to non licensed radio frequency appliance usage around the world. Wireless network integ-
rity and security is accomplished using direct sequence spread spectrum DSSS programming
topology. Wireless applications can be as simple as a single field device communicating with
a host display or any number of field devices forming a network of subscribers. Each device
in the network is assigned its unique device identification or a UID. Every device in the
network can act as a router and repeater for all other devices in the network. This means that
subscribers can “hop” through neighboring devices to communicate with each other
thereby widening network access points. This unique and innovative technology is designed
to create a robust network that automatically routes around congestion and line-of-sight
obstacles while improving throughput as subscriber device density increases.

Standard network configuration is of the master/slave type (320 Transceiver). An optional


and proprietary technology referred to as “Fault Tolerant Safety Network” (300 Trans-
ceiver) is also available which guarantees that no single point of failure will interrupt com-
munications between devices on the rest of the network, including loss of HMI. Processing
power is, in a sense, shared among all devices. There is no controller dependence. Each
device in the network is capable of acting as the network master, processing real time data

Features Applications
Detcon self healing mesh network topology Oil and Gas Drilling Rigs
Universally accepted 2.4 GHz non-licensed frequency Work-over and pulling units
Low power IR gas detection sensor with built-in transceivers Oil and Gas Production
Built-in display for gas sensor/field device HMI Turn-a-rounds in Refining and Petrochemical Plants
Disposable battery packs

www.detcon.com
SmartWireless® Model CXT-IR Infrared LEL Gas Detection Sensor Assembly
R050913

System Specifications Battery Specifications


Sensor Type Smart Rechargeable Battery: 5 months sensor run time full function
Continuous diffusion/adsorption (-20°C to +60°C; -4°F to +140°F discharge temperature; -30°C intermittent).
Non-dispersive Infrared Optical (NDIR) - Combustible Gas Disposable “C” Cell Battery Pack: 2 months sensor run time full function
Sub-miniature plug-in field replaceable (-55°C to +85°C; -67°F to +185°F discharge temperature).
Sensor Life Disposable “D” Cell Battery Pack: 9 months sensor run time full function
5 years typical (-55°C to +85°C; -67°F to +185°F discharge temperature).
Measurement Range
0-100% LEL (lower explosive limit) Electrical Specifications
Accuracy/Repeatability Power Input
±3% 0-50% LEL; ±5% 51-100% LEL 6-30 VDC and/or
Response Time Internal “C” Size Disposable Battery Pack
T50 < 10 seconds, T90 < 30 seconds Rechargeable Battery Pack
Input/Output Power Consumption
25mW (typical), 420mW (max)
2.4Ghz DSSS Radio Transmission
RF
Electrical Classification Outdoor RF Line of Sight (with standard antenna): 1.5 Miles
Explosion proof Interface Data Rate: 9,600bps
Class I, Division 1, Groups C, D (Tamb = -40°C to +75°C) Pending Throughput Data Rate: 19,200bps
Class I, Zone 1, Group IIB+H2 Pending RF Data Rate: 250,000bps
EEx d[ib]ib IIB+H2 T4 (Tamb = -40°C to +75°C) Pending Transceiver Sensitivity: -102dBm
Ingress Protection Frequency: 2.40-2.48GHz
NEMA 4X RF Channels: 16, each 5Mz Wide
Output Power: 100mW (20.5dBm) EIRP
Safety Approvals Spread Spectrum: DSSS (Direct Sequence Spread Spectrum)
CCSAUS Performance to ISA 12.13.01-2000 and CSA 22.2 #152 (Pending) Modulation: 0-QPSK
ATEX (Pending) Supported Network Topologies: Mesh, Point-to-Point
CE Marking (Pending) Antenna
Warranty 5db Flex Whip; Screw on Radome Whip Antenna Guard Included
Plug-in detector - 2 years I/O Protection
Transmitter - 2 Years Over-voltage, Miswiring, EMI/RFI Immunity

Mechanical Specifications Environmental Specifications


Dimensions Operating Temperature Range
With Stainless Steel Mini J-Box -40°F to +167°F; -40°C to +75°C
18"H x 3.62"W x 4.3"D; 457mmH x 92mmW x 109mmD Storage Temperature Range
18"H x 5.5"W x 4.3"D; 457mmH x 140mmW x 109mmD (with XP Power Switch) -40°F to +167°F; -40°C to +75°C
20.5"H; 520mmH (with splashguard) Operating Humidity Range
With Aluminum J-Box (rechargeable battery pack version) 0-100% RH non-condensing
19"H x 5.8"W x 8.5"D; 482mmH x 147mmW x 216mmD
19"H x 7.7"W x 8.5"D; 482mmH x 195mmW x 216mmD (with XP Power Switch)
21.5"H; 546mmH (with splashguard)
Accessory Options
Tripod for Mounting (specify pole mount and/or leg mount brackets)
Weight Mini Tripod for Mounting (specify pole mount and/or leg mount brackets)
5.2 lbs/2.36 kg (w/stainless steel j-box) 7db Gain Antenna
6 lbs/2.72 kg (w/aluminum j-box) Solar Charging Panel
Refer to the CXT-300/320 data sheet for CXT-300/320 transceiver specific specifications
Specifications subject to change without notice
Order Guide
Part Number Description
96C-IR0_0_-100 Model CXT-IR, 0-100 % LEL Combustible
To complete the part number please select from the options below. XXX-XXX_X_- XXX
Position “7” select SmartWireless Transceiver & Power Switch Option Position “9” Junction Box Selection & Power Selection
0 - CXT-DM with 300 fault tolerant transceiver (no power switch) 1 - Aluminum Junction Box (no battery)
1 - CXT-DM with 300 fault tolerant transceiver & XP power switch assembly 2 - Stainless Steel Mini Junction Box with Disposable “C” Size Battery Pack
2 - CXT-DM with 320 mesh transceiver (no power switch) 3 - Stainless Steel Junction Box (no battery)
4 - Aluminum Enclosure with Rechargeable Battery Pack
3 - CXT-DM with 320 mesh transceiver & XP power switch assembly 7 - Aluminum Enclosure with High Output Rechargeable Battery Pack
D - Aluminum Enclosure with Disposable “D” Size Battery Pack
5 - None

Tel: 713-559-9200
Toll Free: 888-367-4286