SGX Cable

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Siechem SGX RoHS

Wires
Wires&&Cables
Cables

Application Product Construction Technical Data


ü Wire harness of low-tension electric circuts for automobiles. ü Conductor : Soft-annealed electrolytic copper ü Temperature Range :
0 0
ü Used in motorcycles and other motor vehicles for E- Cu ETP1 according to ASTM B3 bare conductor - 40 C to +125 C (3000 Hours)
starting, charging, lighting, signal and instrument construction according to SAE J 1127 ü Standard : SAE J1127
panel circuits. ü Insulation : Electron beam cross linked ü Test Voltage : 1 kV
ü Especially used for circuits requiring heat resistance. polyolefin. ü S :Starter or Ground
ü Colour : As per customer order. ü G : General purpose
ü 2Dcore
Single View ü X : Cross linked polyolefin

Features
ü Flame retardant
ü Highly resistant against acids, lyes, petrol ISO ISO IATF OHSAS
and diesel. SGX 9001 14001 16949 18001
ü Flexible conductors with Electron beam cross linked
polyolefin general purpose insulation for smaller
diameter and lesser weight.
ü Extra flexibility.
ü Heat resistant.

Conductor Construction Cable Max. Current


Part Insulation Standard
Overall Conductor Carrying
Number Nominal No. of Diameter of Conductor Wall Thickness Weight Length*
Diameter Resistance Capacity
Cross- Strands Single wire Diameter Nom. Approx.
Max. at 200C
Section max. Nom.
mm2 nos. mm mm mm mm kg/km Ω/km Amps mtrs
82361XX * 13 133 0.36 4.83 1.52 8.60 166 1.40 120 500
82362XX 19 133 0.46 6.09 1.65 10.5 257 0.94 153 500
82363XX 32 133 0.57 7.67 1.65 12.0 373 0.56 205 500
82358XX 40 259 0.46 8.49 1.65 13.0 453 0.42 257 500
82334XX 50 1026 0.26 9.47 1.65 14.5 545 0.36 290 500
82365XX 62 1254 0.26 10.47 1.65 16.0 653 0.27 349 500
82366XX 81 1615 0.26 11.89 1.98 18.5 847 0.21 417 500
82367XX 103 2052 0.26 13.40 1.98 20.0 1052 0.17 483 500

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11
Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21

ü Current Carrying capacity given is for the maximum conductor operating temperature of 1250C and ambient air temperature of 400C.
ü * Other length as per Customer order.

Catalogue
No

823

Siechem Wires & Cables Meet EU RoHS Directive


Lead Hg Cd Cr6+ PBB PBDE
Free Free Free Free Free Free

www.siechem.com
44
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.