OpenECU-EVCC FaultList
OpenECU-EVCC FaultList
N/A 10 64001
31 V 100 64002
9 V 100 64002
5.36 V 10 64003
4.67 V 10 64003
5.36 V 10 64004
4.67 V 10 64004
N/A 5 64005
1 s 64005
N/A 5 64005
5 NU 64005
5 NU 64005
N/A 5 64006
1 s 64006
N/A 5 64006
5 NU 64006
5 NU 64006
N/A 5 64007
1 s 64007
N/A 5 64007
5 NU 64007
5 NU 64007
N/A 5 64008
1 s 64008
N/A 5 64008
5 NU 64008
5 NU 64008
N/A 5 64009
1 s 64009
N/A 5 64009
5 NU 64009
5 NU 64009
N/A 5 64010
1 s 64010
N/A 5 64010
5 NU 64010
5 NU 64010
N/A 5 64011
1 s 64011
N/A 5 64011
5 NU 64011
5 NU 64011
N/A 5 64012
1 s 64012
N/A 5 64012
5 NU 64012
5 NU 64012
N/A 5 64013
1 s 64013
N/A 5 64013
5 NU 64013
5 NU 64013
N/A 5 64014
1 s 64014
N/A 5 64014
5 NU 64014
5 NU 64014
N/A 5 64015
1 s 64015
N/A 5 64015
5 NU 64015
5 NU 64015
N/A 5 64016
1 s 64016
N/A 5 64016
5 NU 64016
5 NU 64016
N/A 5 64017
1 s 64017
N/A 5 64017
5 NU 64017
5 NU 64017
N/A 5 64040
N/A 5 64040
N/A 5 64041
N/A 5 64041
N/A 5 64042
N/A 5 64042
N/A 5 64043
N/A 5 64043
N/A 5 64044
N/A 5 64044
N/A 5 64044
N/A 10 64045
700 mA 3 64045
N/A 75 64046
700 mA 3 64046
3 NU 64047
3 NU 64047
3 NU 64047
3 NU 64047
4 V 50 64049
0.5 V 50 64049
4 V 50 64050
0.5 V 50 64050
4 V 50 64051
0.5 V 50 64051
Vbatt - 2 V 50 64052
1 V 50 64052
1 NU 5 64055
0 NU 5 64055
1 NU 5 64056
0 NU 5 64056
1 NU 5 64057
0 NU 5 64057
1 NU 5 64058
0 NU 5 64058
1 NU 5 64059
0 NU 5 64059
1 NU 5 64060
0 NU 5 64060
100 % 5 64061
0 % 5 64061
1500 V 5 64063
25 V 5 64063
100 % 5 64064
0 % 5 64064
1 NU 5 64065
0 NU 5 64065
1 NU 5 64067
0 NU 5 64067
1500 A 3 64068
-1500 A 3 64068
1500 V 3 64069
25 V 3 64069
1500 A 5 64070
5 A 5 64070
1500 V 5 64071
25 V 5 64071
1000000 W 5 64072
100 W 5 64072
1500 V 5 64073
0 V 5 64073
800 A 5 64074
-800 A 5 64074
1000000 Wh 5 64077
1000 Wh 5 64077
1 NU 5 64078
0 NU 5 64078
1 NU 5 64079
0 NU 5 64079
1 NU 5 64080
0 NU 5 64080
1 NU 5 64081
0 NU 5 64081
1 NU 5 64082
0 NU 5 64082
1 NU 5 64083
0 NU 5 64083
1 NU 5 64084
0 NU 5 64084
3 NU 5 64085
0 NU 5 64085
100 % 5 64087
0 % 5 64087
1500 A 5 64089
0 A 5 64089
1000000 W 5 64090
0 W 5 64090
1500 A 5 64091
0 A 5 64091
1500 A 5 64092
0 A 5 64092
1000000 W 5 64093
0 W 5 64093
1000000 W 5 64094
0 W 5 64094
1500 V 5 64095
0 V 5 64095
1000000 Wh 5 64096
-1000000 Wh 5 64096
1000000 Wh 5 64097
0 Wh 5 64097
1000000 Wh 5 64098
0 Wh 5 64098
100 % 5 64099
10 % 5 64099
System Action
I/O if fault flag is TRUE
Received message length is not 4 bytes for CAN message EV_EvStatus consecutively
and error count exceeds threshold
Time since most recent reception of CAN message EV_EvStatus exceeds a timeout
threshold
More than one CAN message EV_EvStatus is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
Received message length is not 8 bytes for CAN message EV_RessInfo consecutively
and error count exceeds threshold
Time since most recent reception of CAN message EV_RessInfo exceeds a timeout
threshold
More than one CAN message EV_RessInfo is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_RessVoltLimits is received during one sample
time/ model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_RessTargets1 is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_ChgPortInfo is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
Time since most recent reception of CAN message EV_IO_CMD exceeds a timeout
threshold
More than one CAN message EV_IO_CMD is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_ChgCrntLimits is received during one sample
time/ model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_ChgPwrLimits is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_DchgCrntLimits is received during one sample
time/ model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_DchgPwrLimits is received during one sample
time/ model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_RemainingTime is received during one sample
time/ model iteration (overrun) consecutively and overrun exceeds threshold
More than one CAN message EV_RessTargets2 is received during one sample time/
model iteration (overrun) consecutively and overrun exceeds threshold
Output for relay 1 is in any configuration other than disabled and short circuit to
battery is detected on the output for relay 1
Output for relay 1 is in any configuration other than disabled and open load is
detected when the output for relay 1 is off
Output for relay 2 is in any configuration other than disabled and short circuit to
battery is detected on the output for relay 2
Output for relay 2 is in any configuration other than disabled and open load is
detected when the output for relay 2 is off
Output for LED 1 is in any configuration other than disabled and short circuit to
battery is detected on the output for LED 1
Output for LED 1 is in any configuration other than disabled and open load is
detected when the output for LED 1 is off
Output for LED 2 is in any configuration other than disabled and short circuit to
battery is detected on the output for LED 2
Output for LED 2 is in any configuration other than disabled and open load is
detected when the output for LED 2 is off
Output for LED 3 is in any configuration other than disabled and short circuit to
ground is detected on the output for LED 3
Output for LED 3 is in any configuration other than disabled and short circuit to
battery is detected on the output for LED 3
Output for LED 3 is in any configuration other than disabled and open load is
detected when the output for LED 3 is off
Output for Wakeup 1 is in any configuration other than disabled and open load is
detected when the output for Wakeup 1 is OFF
Output for Wakeup 1 is in any configuration other than disabled and overcurrent is
detected on the output for Wakeup 1 is ON
Output for Wakeup 2 is in any configuration other than disabled and open load is
detected when the output for Wakeup 2 is on
Output for Wakeup 2 is in any configuration other than disabled and overcurrent is
detected on the output for Wakeup 2 is ON
Open load is detected when the output for lock actutator is on and charge lock is
not in desired position and retry count exceeds threshold after multiple retries
following a charge lock actuator fault detection
Overcurrent is detected on the output for lock actuator and charge lock is not in
desired position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection
Undervoltage is detected on the output for lock actuator and charge lock is not in
desired position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection
Overtemperature is detected on the output for lock actuator and charge lock is not
in desired position and retry count exceeds threshold after multiple retries
following a charge lock actuator fault detection
Analog input 1 is configured for a temperature sensor input and raw voltage of
analog input 1 is greater than a threshold
Analog input 1 is configured for a temperature sensor input and raw voltage of
analog input 1 is less than a threshold
Analog input 2 is configured for a temperature sensor input and raw voltage of
analog input 2 is greater than a threshold
Analog input 2 is configured for a temperature sensor input and raw voltage of
analog input 2 is less than a threshold
Analog input 3 is configured for a temperature sensor input and raw voltage of
analog input 3 is greater than a threshold
Analog input 3 is configured for a temperature sensor input and raw voltage of
analog input 3 is less than a threshold
Analog input 4 is configured for a lock position feedback voltage input and raw
voltage of analog input 4 is greater than a threshold
Analog input 4 is configured for a lock position feedback voltage input and raw
voltage of analog input 4 is less than a threshold
The received physical (engineering) value of CAN signal Charge Normal Stop is
above a threshold
The received physical (engineering) value of CAN signal Charge Normal Stop is
below a threshold
The received physical (engineering) value of CAN signal Charge Emergency Stop is
above a threshold
The received physical (engineering) value of CAN signal Charge Emergency Stop is
below a threshold
The received physical (engineering) value of CAN signal Permit To Sleep is above a
threshold
The received physical (engineering) value of CAN signal Permit To Sleep is below a
threshold
The received physical (engineering) value of CAN signal Charge Relay Weld-
Checking Status is above a threshold
The received physical (engineering) value of CAN signal Charge Relay Weld-
Checking Status is below a threshold
The received physical (engineering) value of CAN signal Charge Relay(s) Status is
above a threshold
The received physical (engineering) value of CAN signal Charge Relay(s) Status is
below a threshold
The received physical (engineering) value of CAN signal RESS State Of Charge is
above a threshold
The received physical (engineering) value of CAN signal RESS State Of Charge is
below a threshold
The received physical (engineering) value of CAN signal RESS Voltage (Terminal) is
above a threshold
The received physical (engineering) value of CAN signal RESS Voltage (Terminal) is
below a threshold
The received physical (engineering) value of CAN signal RESS Target (Full) SOC is
above a threshold
The received physical (engineering) value of CAN signal RESS Target (Full) SOC is
below a threshold
The received physical (engineering) value of CAN Signal Charge Port Lock Status is
above a threshold
The received physical (engineering) value of CAN Signal Charge Port Lock Status is
below a threshold
The received physical (engineering) value of CAN signal RESS Relay Status is above a
threshold
The received physical (engineering) value of CAN signal RESS Relay Status is below a
threshold
The received physical (engineering) value of CAN signal RESS Demanded (Target)
Current is above a threshold
The received physical (engineering) value of CAN signal RESS Demanded (Target)
Current is below a threshold
The received physical (engineering) value of CAN signal RESS Demanded (Target)
Voltage is above a threshold
The received physical (engineering) value of CAN signal RESS Demanded (Target)
Voltage is below a threshold
The received physical (engineering) value of CAN signal RESS Max Charging Current
is above a threshold
The received physical (engineering) value of CAN signal RESS Max Charging Current
is below a threshold
The received physical (engineering) value of CAN signal RESS Max Voltage is above
a threshold
The received physical (engineering) value of CAN signal RESS Max Voltage is below
a threshold
The received physical (engineering) value of CAN signal RESS Max Charging Power is
above a threshold
The received physical (engineering) value of CAN signal RESS Max Charging Power is
below a threshold
Configuration for port DC measurement is set to available and the received physical
(engineering) value of CAN signal DC voltage measured by EV at the charge inlet is
above a threshold
Configuration for port DC measurement is set to available and the received physical
(engineering) value of CAN signal DC voltage measured by EV at the charge inlet is
below a threshold
Configuration for port DC measurement is set to available and the received physical
(engineering) value of CAN signal DC current measured by EV at the charge inlet is
above a threshold
Configuration for port DC measurement is set to available and the received physical
(engineering) value of CAN signal DC current measured by EV at the charge inlet is
below a threshold
The received physical (engineering) value of CAN signal RESS Total Energy is above
a threshold
The received physical (engineering) value of CAN signal RESS Total Energy is below
a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD1 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD1 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD2 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD2 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD3 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD3 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD4 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD4 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD5 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output LSD5 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output HSD1 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output HSD1 is below a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output HSD2 is above a threshold
The received physical (engineering) value of CAN signal for desired state of digital
output HSD2 is below a threshold
The received physical (engineering) value of CAN signal EV minimum voltage limit is
above a threshold
The received physical (engineering) value of CAN signal EV minimum voltage limit is
below a threshold
The received physical (engineering) value of CAN signal EV energy request is above
a threshold
The received physical (engineering) value of CAN signal EV energy request is below
a threshold
The received physical (engineering) value of CAN signal EV RESS Maximum Energy is
above a threshold
The received physical (engineering) value of CAN signal EV RESS Maximum Energy is
below a threshold
The received physical (engineering) value of CAN signal EV RESS Minimum Energy is
above a threshold
The received physical (engineering) value of CAN signal EV RESS Minimum Energy is
below a threshold
The received physical (engineering) value of CAN signal EV RESS Bulk State Of
Charge is above a threshold
The received physical (engineering) value of CAN signal EV RESS Bulk State Of
Charge is below a threshold
Def tags for system
Bit Enum Name action
req[prod-fltaction-001]
FltCanBusVehOffRatBit_SC
req[prod-fltaction-002]
FltEcuSupplyVoltOorhBit_SC
req[prod-fltaction-003]
FltEcuSupplyVoltOorlBit_SC
req[prod-fltaction-004]
FltVrefaVoltOorhBit_SC
req[prod-fltaction-005]
FltVrefaVoltOorlBit_SC
req[prod-fltaction-006]
FltVrefbVoltOorhBit_SC
req[prod-fltaction-007]
FltVrefbVoltOorlBit_SC
req[prod-fltaction-008]
FltEvCanMsg01CreBit_SC
req[prod-fltaction-009]
FltEvCanMsg01CtoBit_SC
req[prod-fltaction-010]
FltEvCanMsg01CorBit_SC
req[prod-fltaction-011]
FltEvCanMsg01CsmBit_SC
req[prod-fltaction-012]
FltEvCanMsg01CsqBit_SC
req[prod-fltaction-013]
FltEvCanMsg02CreBit_SC
req[prod-fltaction-014]
FltEvCanMsg02CtoBit_SC
req[prod-fltaction-015]
FltEvCanMsg02CorBit_SC
req[prod-fltaction-016]
FltEvCanMsg02CsmBit_SC
req[prod-fltaction-017]
FltEvCanMsg02CsqBit_SC
req[prod-fltaction-018]
FltEvCanMsg03CreBit_SC
req[prod-fltaction-019]
FltEvCanMsg03CtoBit_SC
req[prod-fltaction-020]
FltEvCanMsg03CorBit_SC
req[prod-fltaction-021]
FltEvCanMsg03CsmBit_SC
req[prod-fltaction-022]
FltEvCanMsg03CsqBit_SC
req[prod-fltaction-023]
FltEvCanMsg04CreBit_SC
req[prod-fltaction-024]
FltEvCanMsg04CtoBit_SC
req[prod-fltaction-025]
FltEvCanMsg04CorBit_SC
req[prod-fltaction-026]
FltEvCanMsg04CsmBit_SC
req[prod-fltaction-027]
FltEvCanMsg04CsqBit_SC
req[prod-fltaction-028]
FltEvCanMsg05CreBit_SC
req[prod-fltaction-029]
FltEvCanMsg05CtoBit_SC
req[prod-fltaction-030]
FltEvCanMsg05CorBit_SC
req[prod-fltaction-031]
FltEvCanMsg05CsmBit_SC
req[prod-fltaction-032]
FltEvCanMsg05CsqBit_SC
req[prod-fltaction-033]
FltEvCanMsg06CreBit_SC
req[prod-fltaction-034]
FltEvCanMsg06CtoBit_SC
req[prod-fltaction-035]
FltEvCanMsg06CorBit_SC
req[prod-fltaction-036]
FltEvCanMsg06CsmBit_SC
req[prod-fltaction-037]
FltEvCanMsg06CsqBit_SC
req[prod-fltaction-038]
FltEvCanMsg07CreBit_SC
req[prod-fltaction-039]
FltEvCanMsg07CtoBit_SC
req[prod-fltaction-040]
FltEvCanMsg07CorBit_SC
req[prod-fltaction-041]
FltEvCanMsg07CsmBit_SC
req[prod-fltaction-042]
FltEvCanMsg07CsqBit_SC
req[prod-fltaction-043]
FltEvCanMsg08CreBit_SC
req[prod-fltaction-044]
FltEvCanMsg08CtoBit_SC
req[prod-fltaction-045]
FltEvCanMsg08CorBit_SC
req[prod-fltaction-046]
FltEvCanMsg08CsmBit_SC
req[prod-fltaction-047]
FltEvCanMsg08CsqBit_SC
req[prod-fltaction-048]
FltEvCanMsg09CreBit_SC
req[prod-fltaction-049]
FltEvCanMsg09CtoBit_SC
req[prod-fltaction-050]
FltEvCanMsg09CorBit_SC
req[prod-fltaction-051]
FltEvCanMsg09CsmBit_SC
req[prod-fltaction-052]
FltEvCanMsg09CsqBit_SC
req[prod-fltaction-053]
FltEvCanMsg10CreBit_SC
req[prod-fltaction-054]
FltEvCanMsg10CtoBit_SC
req[prod-fltaction-055]
FltEvCanMsg10CorBit_SC
req[prod-fltaction-056]
FltEvCanMsg10CsmBit_SC
req[prod-fltaction-057]
FltEvCanMsg10CsqBit_SC
req[prod-fltaction-058]
FltEvCanMsg11CreBit_SC
req[prod-fltaction-059]
FltEvCanMsg11CtoBit_SC
req[prod-fltaction-060]
FltEvCanMsg11CorBit_SC
req[prod-fltaction-061]
FltEvCanMsg11CsmBit_SC
req[prod-fltaction-062]
FltEvCanMsg11CsqBit_SC
req[prod-fltaction-063]
FltEvCanMsg12CreBit_SC
req[prod-fltaction-064]
FltEvCanMsg12CtoBit_SC
req[prod-fltaction-065]
FltEvCanMsg12CorBit_SC
req[prod-fltaction-066]
FltEvCanMsg12CsmBit_SC
req[prod-fltaction-067]
FltEvCanMsg12CsqBit_SC
req[prod-fltaction-068]
FltEvCanMsg13CreBit_SC
req[prod-fltaction-069]
FltEvCanMsg13CtoBit_SC
req[prod-fltaction-070]
FltEvCanMsg13CorBit_SC
req[prod-fltaction-071]
FltEvCanMsg13CsmBit_SC
req[prod-fltaction-072]
FltEvCanMsg13CsqBit_SC
req[prod-fltaction-073]
FltDoutLsd1ScbBit_SC
req[prod-fltaction-074]
FltDoutLsd1OffOplBit_SC
req[prod-fltaction-075]
FltDoutLsd2ScbBit_SC
req[prod-fltaction-076]
FltDoutLsd2OffOplBit_SC
req[prod-fltaction-077]
FltDoutLsd3ScbBit_SC
req[prod-fltaction-078]
FltDoutLsd3OffOplBit_SC
req[prod-fltaction-079]
FltDoutLsd4ScbBit_SC
req[prod-fltaction-080]
FltDoutLsd4OffOplBit_SC
req[prod-fltaction-081]
FltDoutLsd5ScgBit_SC
req[prod-fltaction-082]
FltDoutLsd5ScbBit_SC
req[prod-fltaction-083]
FltDoutLsd5OffOplBit_SC
del[prod-fltaction-084]
FltDoutHsd1OplBit_SC req[prod-fltaction-178]
del[prod-fltaction-085]
FltDoutHsd1CrntOorhBit_SC req[prod-fltaction-179]
del[prod-fltaction-086]
FltDoutHsd2OplBit_SC
del[prod-fltaction-087]
FltDoutHsd2CrntOorhBit_SC req[prod-fltaction-180]
req[prod-fltaction-088]
FltHb1OplBit_SC
req[prod-fltaction-089]
FltHb1CrntOorhBit_SC
req[prod-fltaction-090]
FltHb1VoltOorlBit_SC
req[prod-fltaction-091]
FltHb1TempOorhBit_SC
req[prod-fltaction-092]
FltTempAcAin1VoltOorhBit_SC
req[prod-fltaction-093]
FltTempAcAin1VoltOorlBit_SC
req[prod-fltaction-094]
FltTempDcPosAin2VoltOorhBit_SC
req[prod-fltaction-095]
FltTempDcPosAin2VoltOorlBit_SC
req[prod-fltaction-096]
FltTempDcPosAin3VoltOorhBit_SC
req[prod-fltaction-097]
FltTempDcPosAin3VoltOorlBit_SC
req[prod-fltaction-098]
FltLockPosAin4VoltOorhBit_SC
req[prod-fltaction-099]
FltLockPosAin4VoltOorlBit_SC
req[prod-fltaction-100]
FltCrxChgNormStopOobhBit_SC
req[prod-fltaction-101]
FltCrxChgNormStopOoblBit_SC
req[prod-fltaction-102]
FltCrxChgEmergStopOobhBit_SC
req[prod-fltaction-103]
FltCrxChgEmergStopOoblBit_SC
req[prod-fltaction-104]
FltCrxPermitSleepOobhBit_SC
req[prod-fltaction-105]
FltCrxPermitSleepOoblBit_SC
req[prod-fltaction-106]
FltCrxChgRlyWeldStOobhBit_SC
req[prod-fltaction-107]
FltCrxChgRlyWeldStOoblBit_SC
req[prod-fltaction-108]
FltCrxChgRlyStOobhBit_SC
req[prod-fltaction-109]
FltCrxChgRlyStOoblBit_SC
req[prod-fltaction-110]
FltCrxEvIsolStOobhBit_SC
req[prod-fltaction-111]
FltCrxEvIsolStOoblBit_SC
req[prod-fltaction-112]
FltCrxRessSocOobhBit_SC
req[prod-fltaction-113]
FltCrxRessSocOoblBit_SC
req[prod-fltaction-114]
FltCrxRessVoltOobhBit_SC
req[prod-fltaction-115]
FltCrxRessVoltOoblBit_SC
req[prod-fltaction-116]
FltCrxTrgtSocOobhBit_SC
req[prod-fltaction-117]
FltCrxTrgtSocOoblBit_SC
req[prod-fltaction-118]
FltCrxChgPortLockStOobhBit_SC
req[prod-fltaction-119]
FltCrxChgPortLockStOoblBit_SC
req[prod-fltaction-120]
FltCrxRessRlyStOobhBit_SC
req[prod-fltaction-121]
FltCrxRessRlyStOoblBit_SC
req[prod-fltaction-122]
FltCrxTrgtCrntOobhBit_SC
req[prod-fltaction-123]
FltCrxTrgtCrntOoblBit_SC
req[prod-fltaction-124]
FltCrxTrgtVoltOobhBit_SC
req[prod-fltaction-125]
FltCrxTrgtVoltOoblBit_SC
req[prod-fltaction-126]
FltCrxChgCrntMaxOobhBit_SC
req[prod-fltaction-127]
FltCrxChgCrntMaxOoblBit_SC
req[prod-fltaction-128]
FltCrxVoltMaxOobhBit_SC
req[prod-fltaction-129]
FltCrxVoltMaxOoblBit_SC
req[prod-fltaction-130]
FltCrxChgPwrMaxOobhBit_SC
req[prod-fltaction-131]
FltCrxChgPwrMaxOoblBit_SC
req[prod-fltaction-132]
FltCrxPortVoltDcOobhBit_SC
req[prod-fltaction-133]
FltCrxPortVoltDcOoblBit_SC
req[prod-fltaction-134]
FltCrxPortCrntDcOobhBit_SC
req[prod-fltaction-135]
FltCrxPortCrntDcOoblBit_SC
req[prod-fltaction-136]
FltCrxRessTotalEgyOobhBit_SC
req[prod-fltaction-137]
FltCrxRessTotalEgyOoblBit_SC
req[prod-fltaction-138]
FltCrxDoutLsd1OobhBit_SC
req[prod-fltaction-139]
FltCrxDoutLsd1OoblBit_SC
req[prod-fltaction-140]
FltCrxDoutLsd2OobhBit_SC
req[prod-fltaction-141]
FltCrxDoutLsd2OoblBit_SC
req[prod-fltaction-142]
FltCrxDoutLsd3OobhBit_SC
req[prod-fltaction-143]
FltCrxDoutLsd3OoblBit_SC
req[prod-fltaction-144]
FltCrxDoutLsd4OobhBit_SC
req[prod-fltaction-145]
FltCrxDoutLsd4OoblBit_SC
req[prod-fltaction-146]
FltCrxDoutLsd5OobhBit_SC
req[prod-fltaction-147]
FltCrxDoutLsd5OoblBit_SC
req[prod-fltaction-148]
FltCrxDoutHsd1OobhBit_SC
req[prod-fltaction-149]
FltCrxDoutHsd1OoblBit_SC
req[prod-fltaction-150]
FltCrxDoutHsd2OobhBit_SC
req[prod-fltaction-151]
FltCrxDoutHsd2OoblBit_SC
req[prod-fltaction-152]
FltCrxHb1DirOobhBit_SC
req[prod-fltaction-153]
FltCrxHb1DirOoblBit_SC
req[prod-fltaction-154]
FltCrxHb1DutcycOobhBit_SC
req[prod-fltaction-155]
FltCrxHb1DutcycOoblBit_SC
req[prod-fltaction-156]
FltCrxChgCrntMinOobhBit_SC
req[prod-fltaction-157]
FltCrxChgCrntMinOoblBit_SC
req[prod-fltaction-158]
FltCrxChgPwrMinOobhBit_SC
req[prod-fltaction-159]
FltCrxChgPwrMinOoblBit_SC
req[prod-fltaction-160]
FltCrxDchgCrntMaxOobhBit_SC
req[prod-fltaction-161]
FltCrxDchgCrntMaxOoblBit_SC
req[prod-fltaction-162]
FltCrxDchgCrntMinOobhBit_SC
req[prod-fltaction-163]
FltCrxDchgCrntMinOoblBit_SC
req[prod-fltaction-164]
FltCrxDchgPwrMaxOobhBit_SC
req[prod-fltaction-165]
FltCrxDchgPwrMinOobhBit_SC
req[prod-fltaction-166]
FltCrxDchgPwrMinOobhBit_SC
req[prod-fltaction-167]
FltCrxDchgPwrMinOoblBit_SC
req[prod-fltaction-168]
FltCrxVoltMinOobhBit_SC
req[prod-fltaction-169]
FltCrxVoltMinOoblBit_SC
req[prod-fltaction-170]
FltCrxRessEgyReqOobhBit_SC
req[prod-fltaction-171]
FltCrxRessEgyReqOoblBit_SC
req[prod-fltaction-172]
FltCrxRessEgyMaxOobhBit_SC
req[prod-fltaction-173]
FltCrxRessEgyMaxOoblBit_SC
req[prod-fltaction-174]
FltCrxRessEgyMinOobhBit_SC
req[prod-fltaction-175]
FltCrxRessEgyMinOoblBit_SC
req[prod-fltaction-176]
FltCrxRessBulkSocOobhBit_SC
req[prod-fltaction-177]
FltCrxRessBulkSocOoblBit_SC
System action requirements
EVCC shall Immediately terminate the DC charging session if Vehicle CAN bus is in off state (
N/A )
EVCC shall Immediately terminate the DC charging session if ECU Supply Voltage feedback is
greater than a threshold ( 31V )
EVCC shall Immediately terminate the DC charging session if ECU Supply Voltage feedback is less
than a threshold ( 9V )
EVCC shall Immediately terminate the DC charging session if Sensor supply VREF A voltage is
greater than a threshold ( 5.36V )
EVCC shall Immediately terminate the DC charging session if Sensor supply VREF A voltage is less
than a threshold ( 4.67V )
EVCC shall Immediately terminate the DC charging session if Sensor supply VREF B voltage is
greater than a threshold ( 5.36V )
EVCC shall Immediately terminate the DC charging session if Sensor supply VREF B voltage is less
than a threshold ( 4.67V )
EVCC shall Immediately terminate the DC charging session if Received message length is not 4
bytes for CAN message EV_EvStatus consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_EvStatus exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_EvStatus is received during one sample time/ model iteration (overrun) consecutively and
overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_EvStatus is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_EvStatus is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RessInfo consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RessInfo exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RessInfo is received during one sample time/ model iteration (overrun) consecutively and
overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RessInfo is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RessInfo is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RessVoltLimits consecutively and error count exceeds threshold ( N/A
)
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RessVoltLimits exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RessVoltLimits is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RessVoltLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RessVoltLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RessTargets1 consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RessTargets1 exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RessTargets1 is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RessTargets1 is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RessTargets1 is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_ChgPortInfo consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_ChgPortInfo exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_ChgPortInfo is received during one sample time/ model iteration (overrun) consecutively and
overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_ChgPortInfo is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_ChgPortInfo is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_IO_CMD consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_IO_CMD exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_IO_CMD is received during one sample time/ model iteration (overrun) consecutively and
overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_IO_CMD is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_IO_CMD is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_ChgCrntLimits consecutively and error count exceeds threshold (
N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_ChgCrntLimits exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_ChgCrntLimits is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_ChgCrntLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_ChgCrntLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_ChgPwrLimits consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_ChgPwrLimits exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_ChgPwrLimits is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_ChgPwrLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_ChgPwrLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_DchgCrntLimits consecutively and error count exceeds threshold
( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_DchgCrntLimits exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_DchgCrntLimits is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_DchgCrntLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_DchgCrntLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_DchgPwrLimits consecutively and error count exceeds threshold ( N/A
)
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_DchgPwrLimits exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_DchgPwrLimits is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_DchgPwrLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_DchgPwrLimits is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RemainingTime consecutively and error count exceeds threshold
( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RemainingTime exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RemainingTime is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RemainingTime is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RemainingTime is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RessEnergy consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RessEnergy exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RessEnergy is received during one sample time/ model iteration (overrun) consecutively and
overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RessEnergy is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RessEnergy is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Received message length is not 8
bytes for CAN message EV_RessTargets2 consecutively and error count exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Time since most recent reception of
CAN message EV_RessTargets2 exceeds a timeout threshold ( 1s )
EVCC shall Immediately terminate the DC charging session if More than one CAN message
EV_RessTargets2 is received during one sample time/ model iteration (overrun) consecutively
and overrun exceeds threshold ( N/A )
EVCC shall Immediately terminate the DC charging session if Checksum for CAN message
EV_RessTargets2 is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Rolling counter sequence for CAN
message EV_RessTargets2 is incorrect consecutively and exceeds threshold ( 5NU )
EVCC shall Immediately terminate the DC charging session if Output for relay 1 is in any
configuration other than disabled and short circuit to battery is detected on the output for relay
1 ( N/A )
EVCC shall Immediately terminate the DC charging session if Output for relay 1 is in any
configuration other than disabled and open load is detected when the output for relay 1 is off
( N/A )
EVCC shall Immediately terminate the DC charging session if Output for relay 2 is in any
configuration other than disabled and short circuit to battery is detected on the output for relay
2 ( N/A )
EVCC shall Immediately terminate the DC charging session if Output for relay 2 is in any
configuration other than disabled and open load is detected when the output for relay 2 is off
( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 1 is in any configuration other
than disabled and short circuit to battery is detected on the output for LED 1 ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 1 is in any configuration other
than disabled and open load is detected when the output for LED 1 is off ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 2 is in any configuration other
than disabled and short circuit to battery is detected on the output for LED 2 ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 2 is in any configuration other
than disabled and open load is detected when the output for LED 2 is off ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 3 is in any configuration other
than disabled and short circuit to ground is detected on the output for LED 3 ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 3 is in any configuration other
than disabled and short circuit to battery is detected on the output for LED 3 ( N/A )
EVCC shall set a fault for reporting over CAN if Output for LED 3 is in any configuration other
than disabled and open load is detected when the output for LED 3 is off ( N/A )
EVCC shall Immediately terminate the DC charging session if Output for Wakeup 1 is in any
configuration other than disabled and open load is detected when the output for Wakeup 1 is
OFF ( N/A )
EVCC shall Immediately terminate the DC charging session if Output for Wakeup 1 is in any
configuration other than disabled and overcurrent is detected on the output for Wakeup 1 is ON
( 700mA )
EVCC shall Immediately terminate the DC charging session if Output for Wakeup 2 is in any
configuration other than disabled and open load is detected when the output for Wakeup 2 is on
( N/A )
EVCC shall Immediately terminate the DC charging session if Output for Wakeup 2 is in any
configuration other than disabled and overcurrent is detected on the output for Wakeup 2 is ON
( 700mA )
EVCC shall Terminate the DC charging session if Open load is detected when the output for lock
actutator is on and charge lock is not in desired position and retry count exceeds threshold after
multiple retries following a charge lock actuator fault detection ( 3NU )
EVCC shall Terminate the DC charging session if Overcurrent is detected on the output for lock
actuator and charge lock is not in desired position and retry count exceeds threshold after
multiple retries following a charge lock actuator fault detection ( 3NU )
EVCC shall Terminate the DC charging session if Undervoltage is detected on the output for lock
actuator and charge lock is not in desired position and retry count exceeds threshold after
multiple retries following a charge lock actuator fault detection ( 3NU )
EVCC shall Terminate the DC charging session if Overtemperature is detected on the output for
lock actuator and charge lock is not in desired position and retry count exceeds threshold after
multiple retries following a charge lock actuator fault detection ( 3NU )
EVCC shall Immediately terminate the DC charging session if Analog input 1 is configured for a
temperature sensor input and raw voltage of analog input 1 is greater than a threshold ( 4V )
EVCC shall Immediately terminate the DC charging session if Analog input 1 is configured for a
temperature sensor input and raw voltage of analog input 1 is less than a threshold ( 0.5V )
EVCC shall Immediately terminate the DC charging session if Analog input 2 is configured for a
temperature sensor input and raw voltage of analog input 2 is greater than a threshold ( 4V )
EVCC shall Immediately terminate the DC charging session if Analog input 2 is configured for a
temperature sensor input and raw voltage of analog input 2 is less than a threshold ( 0.5V )
EVCC shall Immediately terminate the DC charging session if Analog input 3 is configured for a
temperature sensor input and raw voltage of analog input 3 is greater than a threshold ( 4V )
EVCC shall Immediately terminate the DC charging session if Analog input 3 is configured for a
temperature sensor input and raw voltage of analog input 3 is less than a threshold ( 0.5V )
EVCC shall Immediately terminate the DC charging session if Analog input 4 is configured for a
lock position feedback voltage input and raw voltage of analog input 4 is greater than a threshold
( Vbatt - 2V )
EVCC shall Immediately terminate the DC charging session if Analog input 4 is configured for a
lock position feedback voltage input and raw voltage of analog input 4 is less than a threshold
( 1V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Normal Stop is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Normal Stop is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Emergency Stop is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Emergency Stop is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Permit To Sleep is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Permit To Sleep is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Charge Relay Weld-Checking Status is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Charge Relay Weld-Checking Status is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Relay(s) Status is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal Charge Relay(s) Status is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV HV Isolation Monitoring Status is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV HV Isolation Monitoring Status is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS State Of Charge is above a threshold ( 100% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS State Of Charge is below a threshold ( 0% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Voltage (Terminal) is above a threshold ( 1500V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Voltage (Terminal) is below a threshold ( 25V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Target (Full) SOC is above a threshold ( 100% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Target (Full) SOC is below a threshold ( 0% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN Signal Charge Port Lock Status is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN Signal Charge Port Lock Status is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Relay Status is above a threshold ( 1NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Relay Status is below a threshold ( 0NU )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Demanded (Target) Current is above a threshold ( 1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Demanded (Target) Current is below a threshold ( -1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Demanded (Target) Voltage is above a threshold ( 1500V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Demanded (Target) Voltage is below a threshold ( 25V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Charging Current is above a threshold ( 1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Charging Current is below a threshold ( 5A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Voltage is above a threshold ( 1500V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Voltage is below a threshold ( 25V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Charging Power is above a threshold ( 1000000W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Max Charging Power is below a threshold ( 100W )
EVCC shall Immediately terminate the DC charging session if Configuration for port DC
measurement is set to available and the received physical (engineering) value of CAN signal DC
voltage measured by EV at the charge inlet is above a threshold ( 1500V )
EVCC shall Immediately terminate the DC charging session if Configuration for port DC
measurement is set to available and the received physical (engineering) value of CAN signal DC
voltage measured by EV at the charge inlet is below a threshold ( 0V )
EVCC shall Immediately terminate the DC charging session if Configuration for port DC
measurement is set to available and the received physical (engineering) value of CAN signal DC
current measured by EV at the charge inlet is above a threshold ( 800A )
EVCC shall Immediately terminate the DC charging session if Configuration for port DC
measurement is set to available and the received physical (engineering) value of CAN signal DC
current measured by EV at the charge inlet is below a threshold ( -800A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Total Energy is above a threshold ( 1000000Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal RESS Total Energy is below a threshold ( 1000Wh )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD1 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD1 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD2 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD2 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD3 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD3 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD4 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD4 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD5 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output LSD5 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output HSD1 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output HSD1 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output HSD2 is above a threshold ( 1NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal for desired state of digital output HSD2 is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Hbridge 1 Direction Commmand is above a threshold ( 3NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Hbridge 1 Direction Commmand is below a threshold ( 0NU )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Hbridge 1 Dutycycle Commmand is above a threshold ( 100% )
EVCC shall set a fault for reporting over CAN if The received physical (engineering) value of CAN
signal Hbridge 1 Dutycycle Commmand is below a threshold ( 0% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum charging current limit is above a threshold ( 1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum charging current limit is below a threshold ( 0A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum charging power limit is above a threshold ( 1000000W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum charging power limit is below a threshold ( 0W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV maximum discharge current limit is above a threshold ( 1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV maximum discharge current limit is below a threshold ( 0A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum discharge current limit is above a threshold ( 1500A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum discharge current limit is below a threshold ( 0A )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV maximum discharge power limit is above a threshold ( 1000000W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV maximum discharge power limit is below a threshold ( 0W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum discharge power limit is above a threshold ( 1000000W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum discharge power limit is below a threshold ( 0W )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum voltage limit is above a threshold ( 1500V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV minimum voltage limit is below a threshold ( 0V )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV energy request is above a threshold ( 1000000Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV energy request is below a threshold ( -1000000Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Maximum Energy is above a threshold ( 1000000Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Maximum Energy is below a threshold ( 0Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Minimum Energy is above a threshold ( 1000000Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Minimum Energy is below a threshold ( 0Wh )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Bulk State Of Charge is above a threshold ( 100% )
EVCC shall Immediately terminate the DC charging session if The received physical (engineering)
value of CAN signal EV RESS Bulk State Of Charge is below a threshold ( 10% )
Def tags for fault
detection and DTC DTC requirements
[prod-fltdtc-047 EVCC shall set a J1939 DTC with SPN 64001 and FMI if Vehicle CAN bus is in
off state ( N/A )
[prod-fltdtc-048 EVCC shall set a J1939 DTC with SPN 64002 and FMI if ECU Supply Voltage
feedback is greater than a threshold ( 31V )
[prod-fltdtc-049 EVCC shall set a J1939 DTC with SPN 64002 and FMI if ECU Supply Voltage
feedback is less than a threshold ( 9V )
[prod-fltdtc-050 EVCC shall set a J1939 DTC with SPN 64003 and FMI if Sensor supply VREF A
voltage is greater than a threshold ( 5.36V )
[prod-fltdtc-051 EVCC shall set a J1939 DTC with SPN 64003 and FMI if Sensor supply VREF A
voltage is less than a threshold ( 4.67V )
[prod-fltdtc-052 EVCC shall set a J1939 DTC with SPN 64004 and FMI if Sensor supply VREF B
voltage is greater than a threshold ( 5.36V )
[prod-fltdtc-053 EVCC shall set a J1939 DTC with SPN 64004 and FMI if Sensor supply VREF B
voltage is less than a threshold ( 4.67V )
[prod-fltdtc-054 EVCC shall set a J1939 DTC with SPN 64005 and FMI if Received message
length is not 4 bytes for CAN message EV_EvStatus consecutively and error
count exceeds threshold ( N/A )
[prod-fltdtc-055 EVCC shall set a J1939 DTC with SPN 64005 and FMI if Time since most recent
reception of CAN message EV_EvStatus exceeds a timeout threshold ( 1s )
[prod-fltdtc-056 EVCC shall set a J1939 DTC with SPN 64005 and FMI if More than one CAN
message EV_EvStatus is received during one sample time/ model iteration
(overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-057 EVCC shall set a J1939 DTC with SPN 64005 and FMI if Checksum for CAN
message EV_EvStatus is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-058 EVCC shall set a J1939 DTC with SPN 64005 and FMI if Rolling counter
sequence for CAN message EV_EvStatus is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-059 EVCC shall set a J1939 DTC with SPN 64006 and FMI if Received message
length is not 8 bytes for CAN message EV_RessInfo consecutively and error
count exceeds threshold ( N/A )
[prod-fltdtc-060 EVCC shall set a J1939 DTC with SPN 64006 and FMI if Time since most recent
reception of CAN message EV_RessInfo exceeds a timeout threshold ( 1s )
[prod-fltdtc-061 EVCC shall set a J1939 DTC with SPN 64006 and FMI if More than one CAN
message EV_RessInfo is received during one sample time/ model iteration
(overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-062 EVCC shall set a J1939 DTC with SPN 64006 and FMI if Checksum for CAN
message EV_RessInfo is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-063 EVCC shall set a J1939 DTC with SPN 64006 and FMI if Rolling counter
sequence for CAN message EV_RessInfo is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-064 EVCC shall set a J1939 DTC with SPN 64007 and FMI if Received message
length is not 8 bytes for CAN message EV_RessVoltLimits consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-065 EVCC shall set a J1939 DTC with SPN 64007 and FMI if Time since most recent
reception of CAN message EV_RessVoltLimits exceeds a timeout threshold
( 1s )
[prod-fltdtc-066 EVCC shall set a J1939 DTC with SPN 64007 and FMI if More than one CAN
message EV_RessVoltLimits is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-067 EVCC shall set a J1939 DTC with SPN 64007 and FMI if Checksum for CAN
message EV_RessVoltLimits is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-068 EVCC shall set a J1939 DTC with SPN 64007 and FMI if Rolling counter
sequence for CAN message EV_RessVoltLimits is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-069 EVCC shall set a J1939 DTC with SPN 64008 and FMI if Received message
length is not 8 bytes for CAN message EV_RessTargets1 consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-070 EVCC shall set a J1939 DTC with SPN 64008 and FMI if Time since most recent
reception of CAN message EV_RessTargets1 exceeds a timeout threshold
( 1s )
[prod-fltdtc-071 EVCC shall set a J1939 DTC with SPN 64008 and FMI if More than one CAN
message EV_RessTargets1 is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-072 EVCC shall set a J1939 DTC with SPN 64008 and FMI if Checksum for CAN
message EV_RessTargets1 is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-073 EVCC shall set a J1939 DTC with SPN 64008 and FMI if Rolling counter
sequence for CAN message EV_RessTargets1 is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-074 EVCC shall set a J1939 DTC with SPN 64009 and FMI if Received message
length is not 8 bytes for CAN message EV_ChgPortInfo consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-075 EVCC shall set a J1939 DTC with SPN 64009 and FMI if Time since most recent
reception of CAN message EV_ChgPortInfo exceeds a timeout threshold ( 1s )
[prod-fltdtc-076 EVCC shall set a J1939 DTC with SPN 64009 and FMI if More than one CAN
message EV_ChgPortInfo is received during one sample time/ model iteration
(overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-077 EVCC shall set a J1939 DTC with SPN 64009 and FMI if Checksum for CAN
message EV_ChgPortInfo is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-078 EVCC shall set a J1939 DTC with SPN 64009 and FMI if Rolling counter
sequence for CAN message EV_ChgPortInfo is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-079 EVCC shall set a J1939 DTC with SPN 64010 and FMI if Received message
length is not 8 bytes for CAN message EV_IO_CMD consecutively and error
count exceeds threshold ( N/A )
[prod-fltdtc-080 EVCC shall set a J1939 DTC with SPN 64010 and FMI if Time since most recent
reception of CAN message EV_IO_CMD exceeds a timeout threshold ( 1s )
[prod-fltdtc-081 EVCC shall set a J1939 DTC with SPN 64010 and FMI if More than one CAN
message EV_IO_CMD is received during one sample time/ model iteration
(overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-082 EVCC shall set a J1939 DTC with SPN 64010 and FMI if Checksum for CAN
message EV_IO_CMD is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-083 EVCC shall set a J1939 DTC with SPN 64010 and FMI if Rolling counter
sequence for CAN message EV_IO_CMD is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-084 EVCC shall set a J1939 DTC with SPN 64011 and FMI if Received message
length is not 8 bytes for CAN message EV_ChgCrntLimits consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-085 EVCC shall set a J1939 DTC with SPN 64011 and FMI if Time since most recent
reception of CAN message EV_ChgCrntLimits exceeds a timeout threshold ( 1s
)
[prod-fltdtc-086 EVCC shall set a J1939 DTC with SPN 64011 and FMI if More than one CAN
message EV_ChgCrntLimits is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-087 EVCC shall set a J1939 DTC with SPN 64011 and FMI if Checksum for CAN
message EV_ChgCrntLimits is incorrect consecutively and exceeds threshold (
5NU )
[prod-fltdtc-088 EVCC shall set a J1939 DTC with SPN 64011 and FMI if Rolling counter
sequence for CAN message EV_ChgCrntLimits is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-089 EVCC shall set a J1939 DTC with SPN 64012 and FMI if Received message
length is not 8 bytes for CAN message EV_ChgPwrLimits consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-090 EVCC shall set a J1939 DTC with SPN 64012 and FMI if Time since most recent
reception of CAN message EV_ChgPwrLimits exceeds a timeout threshold
( 1s )
[prod-fltdtc-091 EVCC shall set a J1939 DTC with SPN 64012 and FMI if More than one CAN
message EV_ChgPwrLimits is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-092 EVCC shall set a J1939 DTC with SPN 64012 and FMI if Checksum for CAN
message EV_ChgPwrLimits is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-093 EVCC shall set a J1939 DTC with SPN 64012 and FMI if Rolling counter
sequence for CAN message EV_ChgPwrLimits is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-094 EVCC shall set a J1939 DTC with SPN 64013 and FMI if Received message
length is not 8 bytes for CAN message EV_DchgCrntLimits consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-095 EVCC shall set a J1939 DTC with SPN 64013 and FMI if Time since most recent
reception of CAN message EV_DchgCrntLimits exceeds a timeout threshold
( 1s )
[prod-fltdtc-096 EVCC shall set a J1939 DTC with SPN 64013 and FMI if More than one CAN
message EV_DchgCrntLimits is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-097 EVCC shall set a J1939 DTC with SPN 64013 and FMI if Checksum for CAN
message EV_DchgCrntLimits is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-098 EVCC shall set a J1939 DTC with SPN 64013 and FMI if Rolling counter
sequence for CAN message EV_DchgCrntLimits is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-099 EVCC shall set a J1939 DTC with SPN 64014 and FMI if Received message
length is not 8 bytes for CAN message EV_DchgPwrLimits consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-100 EVCC shall set a J1939 DTC with SPN 64014 and FMI if Time since most recent
reception of CAN message EV_DchgPwrLimits exceeds a timeout threshold
( 1s )
[prod-fltdtc-101 EVCC shall set a J1939 DTC with SPN 64014 and FMI if More than one CAN
message EV_DchgPwrLimits is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-102 EVCC shall set a J1939 DTC with SPN 64014 and FMI if Checksum for CAN
message EV_DchgPwrLimits is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-103 EVCC shall set a J1939 DTC with SPN 64014 and FMI if Rolling counter
sequence for CAN message EV_DchgPwrLimits is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-104 EVCC shall set a J1939 DTC with SPN 64015 and FMI if Received message
length is not 8 bytes for CAN message EV_RemainingTime consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-105 EVCC shall set a J1939 DTC with SPN 64015 and FMI if Time since most recent
reception of CAN message EV_RemainingTime exceeds a timeout threshold
( 1s )
[prod-fltdtc-106 EVCC shall set a J1939 DTC with SPN 64015 and FMI if More than one CAN
message EV_RemainingTime is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-107 EVCC shall set a J1939 DTC with SPN 64015 and FMI if Checksum for CAN
message EV_RemainingTime is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-108 EVCC shall set a J1939 DTC with SPN 64015 and FMI if Rolling counter
sequence for CAN message EV_RemainingTime is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-109 EVCC shall set a J1939 DTC with SPN 64016 and FMI if Received message
length is not 8 bytes for CAN message EV_RessEnergy consecutively and error
count exceeds threshold ( N/A )
[prod-fltdtc-110 EVCC shall set a J1939 DTC with SPN 64016 and FMI if Time since most recent
reception of CAN message EV_RessEnergy exceeds a timeout threshold ( 1s )
[prod-fltdtc-111 EVCC shall set a J1939 DTC with SPN 64016 and FMI if More than one CAN
message EV_RessEnergy is received during one sample time/ model iteration
(overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-112 EVCC shall set a J1939 DTC with SPN 64016 and FMI if Checksum for CAN
message EV_RessEnergy is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-113 EVCC shall set a J1939 DTC with SPN 64016 and FMI if Rolling counter
sequence for CAN message EV_RessEnergy is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-114 EVCC shall set a J1939 DTC with SPN 64017 and FMI if Received message
length is not 8 bytes for CAN message EV_RessTargets2 consecutively and
error count exceeds threshold ( N/A )
[prod-fltdtc-115 EVCC shall set a J1939 DTC with SPN 64017 and FMI if Time since most recent
reception of CAN message EV_RessTargets2 exceeds a timeout threshold
( 1s )
[prod-fltdtc-116 EVCC shall set a J1939 DTC with SPN 64017 and FMI if More than one CAN
message EV_RessTargets2 is received during one sample time/ model
iteration (overrun) consecutively and overrun exceeds threshold ( N/A )
[prod-fltdtc-117 EVCC shall set a J1939 DTC with SPN 64017 and FMI if Checksum for CAN
message EV_RessTargets2 is incorrect consecutively and exceeds threshold
( 5NU )
[prod-fltdtc-118 EVCC shall set a J1939 DTC with SPN 64017 and FMI if Rolling counter
sequence for CAN message EV_RessTargets2 is incorrect consecutively and
exceeds threshold ( 5NU )
[prod-fltdtc-119 EVCC shall set a J1939 DTC with SPN 64040 and FMI if Output for relay 1 is in
any configuration other than disabled and short circuit to battery is detected
on the output for relay 1 ( N/A )
[prod-fltdtc-120 EVCC shall set a J1939 DTC with SPN 64040 and FMI if Output for relay 1 is in
any configuration other than disabled and open load is detected when the
output for relay 1 is off ( N/A )
[prod-fltdtc-121 EVCC shall set a J1939 DTC with SPN 64041 and FMI if Output for relay 2 is in
any configuration other than disabled and short circuit to battery is detected
on the output for relay 2 ( N/A )
[prod-fltdtc-122 EVCC shall set a J1939 DTC with SPN 64041 and FMI if Output for relay 2 is in
any configuration other than disabled and open load is detected when the
output for relay 2 is off ( N/A )
[prod-fltdtc-123 EVCC shall set a J1939 DTC with SPN 64042 and FMI if Output for LED 1 is in
any configuration other than disabled and short circuit to battery is detected
on the output for LED 1 ( N/A )
[prod-fltdtc-124 EVCC shall set a J1939 DTC with SPN 64042 and FMI if Output for LED 1 is in
any configuration other than disabled and open load is detected when the
output for LED 1 is off ( N/A )
[prod-fltdtc-125 EVCC shall set a J1939 DTC with SPN 64043 and FMI if Output for LED 2 is in
any configuration other than disabled and short circuit to battery is detected
on the output for LED 2 ( N/A )
[prod-fltdtc-126 EVCC shall set a J1939 DTC with SPN 64043 and FMI if Output for LED 2 is in
any configuration other than disabled and open load is detected when the
output for LED 2 is off ( N/A )
EVCC shall set a J1939 DTC with SPN 64044 and FMI if Output for LED 3 is in
any configuration other than disabled and short circuit to ground is detected
on the output for LED 3 ( N/A )
EVCC shall set a J1939 DTC with SPN 64044 and FMI if Output for LED 3 is in
any configuration other than disabled and short circuit to battery is detected
on the output for LED 3 ( N/A )
EVCC shall set a J1939 DTC with SPN 64044 and FMI if Output for LED 3 is in
any configuration other than disabled and open load is detected when the
output for LED 3 is off ( N/A )
[prod-fltdtc-127 EVCC shall set a J1939 DTC with SPN 64045 and FMI if Output for Wakeup 1
is in any configuration other than disabled and open load is detected when
the output for Wakeup 1 is OFF ( N/A )
[prod-fltdtc-128 EVCC shall set a J1939 DTC with SPN 64045 and FMI if Output for Wakeup 1
is in any configuration other than disabled and overcurrent is detected on the
output for Wakeup 1 is ON ( 700mA )
[prod-fltdtc-129 EVCC shall set a J1939 DTC with SPN 64046 and FMI if Output for Wakeup 2
is in any configuration other than disabled and open load is detected when
the output for Wakeup 2 is on ( N/A )
[prod-fltdtc-130 EVCC shall set a J1939 DTC with SPN 64046 and FMI if Output for Wakeup 2
is in any configuration other than disabled and overcurrent is detected on the
output for Wakeup 2 is ON ( 700mA )
[prod-fltdtc-131 EVCC shall set a J1939 DTC with SPN 64047 and FMI if Open load is detected
when the output for lock actutator is on and charge lock is not in desired
position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection ( 3NU )
[prod-fltdtc-132 EVCC shall set a J1939 DTC with SPN 64047 and FMI if Overcurrent is
detected on the output for lock actuator and charge lock is not in desired
position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection ( 3NU )
[prod-fltdtc-133 EVCC shall set a J1939 DTC with SPN 64047 and FMI if Undervoltage is
detected on the output for lock actuator and charge lock is not in desired
position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection ( 3NU )
[prod-fltdtc-134 EVCC shall set a J1939 DTC with SPN 64047 and FMI if Overtemperature is
detected on the output for lock actuator and charge lock is not in desired
position and retry count exceeds threshold after multiple retries following a
charge lock actuator fault detection ( 3NU )
[prod-fltdtc-135 EVCC shall set a J1939 DTC with SPN 64049 and FMI if Analog input 1 is
configured for a temperature sensor input and raw voltage of analog input 1
is greater than a threshold ( 4V )
[prod-fltdtc-136 EVCC shall set a J1939 DTC with SPN 64049 and FMI if Analog input 1 is
configured for a temperature sensor input and raw voltage of analog input 1
is less than a threshold ( 0.5V )
[prod-fltdtc-137 EVCC shall set a J1939 DTC with SPN 64050 and FMI if Analog input 2 is
configured for a temperature sensor input and raw voltage of analog input 2
is greater than a threshold ( 4V )
[prod-fltdtc-138 EVCC shall set a J1939 DTC with SPN 64050 and FMI if Analog input 2 is
configured for a temperature sensor input and raw voltage of analog input 2
is less than a threshold ( 0.5V )
[prod-fltdtc-139 EVCC shall set a J1939 DTC with SPN 64051 and FMI if Analog input 3 is
configured for a temperature sensor input and raw voltage of analog input 3
is greater than a threshold ( 4V )
[prod-fltdtc-140 EVCC shall set a J1939 DTC with SPN 64051 and FMI if Analog input 3 is
configured for a temperature sensor input and raw voltage of analog input 3
is less than a threshold ( 0.5V )
[prod-fltdtc-141 EVCC shall set a J1939 DTC with SPN 64052 and FMI if Analog input 4 is
configured for a lock position feedback voltage input and raw voltage of
analog input 4 is greater than a threshold ( Vbatt - 2V )
[prod-fltdtc-142 EVCC shall set a J1939 DTC with SPN 64052 and FMI if Analog input 4 is
configured for a lock position feedback voltage input and raw voltage of
analog input 4 is less than a threshold ( 1V )
[prod-fltdtc-143 EVCC shall set a J1939 DTC with SPN 64055 and FMI if The received physical
(engineering) value of CAN signal Charge Normal Stop is above a threshold
( 1NU )
[prod-fltdtc-144 EVCC shall set a J1939 DTC with SPN 64055 and FMI if The received physical
(engineering) value of CAN signal Charge Normal Stop is below a threshold
( 0NU )
[prod-fltdtc-145 EVCC shall set a J1939 DTC with SPN 64056 and FMI if The received physical
(engineering) value of CAN signal Charge Emergency Stop is above a
threshold ( 1NU )
[prod-fltdtc-146 EVCC shall set a J1939 DTC with SPN 64056 and FMI if The received physical
(engineering) value of CAN signal Charge Emergency Stop is below a
threshold ( 0NU )
[prod-fltdtc-147 EVCC shall set a J1939 DTC with SPN 64057 and FMI if The received physical
(engineering) value of CAN signal Permit To Sleep is above a threshold
( 1NU )
[prod-fltdtc-148 EVCC shall set a J1939 DTC with SPN 64057 and FMI if The received physical
(engineering) value of CAN signal Permit To Sleep is below a threshold
( 0NU )
[prod-fltdtc-149 EVCC shall set a J1939 DTC with SPN 64058 and FMI if The received physical
(engineering) value of CAN signal Charge Relay Weld-Checking Status is above
a threshold ( 1NU )
[prod-fltdtc-150 EVCC shall set a J1939 DTC with SPN 64058 and FMI if The received physical
(engineering) value of CAN signal Charge Relay Weld-Checking Status is below
a threshold ( 0NU )
[prod-fltdtc-151 EVCC shall set a J1939 DTC with SPN 64059 and FMI if The received physical
(engineering) value of CAN signal Charge Relay(s) Status is above a threshold (
1NU )
[prod-fltdtc-152 EVCC shall set a J1939 DTC with SPN 64059 and FMI if The received physical
(engineering) value of CAN signal Charge Relay(s) Status is below a threshold (
0NU )
[prod-fltdtc-153 EVCC shall set a J1939 DTC with SPN 64060 and FMI if The received physical
(engineering) value of CAN signal EV HV Isolation Monitoring Status is above a
threshold ( 1NU )
[prod-fltdtc-154 EVCC shall set a J1939 DTC with SPN 64060 and FMI if The received physical
(engineering) value of CAN signal EV HV Isolation Monitoring Status is below a
threshold ( 0NU )
[prod-fltdtc-155 EVCC shall set a J1939 DTC with SPN 64061 and FMI if The received physical
(engineering) value of CAN signal RESS State Of Charge is above a threshold
( 100% )
[prod-fltdtc-156 EVCC shall set a J1939 DTC with SPN 64061 and FMI if The received physical
(engineering) value of CAN signal RESS State Of Charge is below a threshold
( 0% )
[prod-fltdtc-157 EVCC shall set a J1939 DTC with SPN 64063 and FMI if The received physical
(engineering) value of CAN signal RESS Voltage (Terminal) is above a
threshold ( 1500V )
[prod-fltdtc-158 EVCC shall set a J1939 DTC with SPN 64063 and FMI if The received physical
(engineering) value of CAN signal RESS Voltage (Terminal) is below a
threshold ( 25V )
[prod-fltdtc-159 EVCC shall set a J1939 DTC with SPN 64064 and FMI if The received physical
(engineering) value of CAN signal RESS Target (Full) SOC is above a threshold (
100% )
[prod-fltdtc-160 EVCC shall set a J1939 DTC with SPN 64064 and FMI if The received physical
(engineering) value of CAN signal RESS Target (Full) SOC is below a threshold (
0% )
[prod-fltdtc-161 EVCC shall set a J1939 DTC with SPN 64065 and FMI if The received physical
(engineering) value of CAN Signal Charge Port Lock Status is above a
threshold ( 1NU )
[prod-fltdtc-162 EVCC shall set a J1939 DTC with SPN 64065 and FMI if The received physical
(engineering) value of CAN Signal Charge Port Lock Status is below a
threshold ( 0NU )
[prod-fltdtc-163 EVCC shall set a J1939 DTC with SPN 64067 and FMI if The received physical
(engineering) value of CAN signal RESS Relay Status is above a threshold
( 1NU )
[prod-fltdtc-164 EVCC shall set a J1939 DTC with SPN 64067 and FMI if The received physical
(engineering) value of CAN signal RESS Relay Status is below a threshold
( 0NU )
[prod-fltdtc-165 EVCC shall set a J1939 DTC with SPN 64068 and FMI if The received physical
(engineering) value of CAN signal RESS Demanded (Target) Current is above a
threshold ( 1500A )
[prod-fltdtc-166 EVCC shall set a J1939 DTC with SPN 64068 and FMI if The received physical
(engineering) value of CAN signal RESS Demanded (Target) Current is below a
threshold ( -1500A )
[prod-fltdtc-167 EVCC shall set a J1939 DTC with SPN 64069 and FMI if The received physical
(engineering) value of CAN signal RESS Demanded (Target) Voltage is above a
threshold ( 1500V )
[prod-fltdtc-168 EVCC shall set a J1939 DTC with SPN 64069 and FMI if The received physical
(engineering) value of CAN signal RESS Demanded (Target) Voltage is below a
threshold ( 25V )
[prod-fltdtc-169 EVCC shall set a J1939 DTC with SPN 64070 and FMI if The received physical
(engineering) value of CAN signal RESS Max Charging Current is above a
threshold ( 1500A )
[prod-fltdtc-170 EVCC shall set a J1939 DTC with SPN 64070 and FMI if The received physical
(engineering) value of CAN signal RESS Max Charging Current is below a
threshold ( 5A )
[prod-fltdtc-171 EVCC shall set a J1939 DTC with SPN 64071 and FMI if The received physical
(engineering) value of CAN signal RESS Max Voltage is above a threshold
( 1500V )
[prod-fltdtc-172 EVCC shall set a J1939 DTC with SPN 64071 and FMI if The received physical
(engineering) value of CAN signal RESS Max Voltage is below a threshold ( 25V
)
[prod-fltdtc-173 EVCC shall set a J1939 DTC with SPN 64072 and FMI if The received physical
(engineering) value of CAN signal RESS Max Charging Power is above a
threshold ( 1000000W )
[prod-fltdtc-174 EVCC shall set a J1939 DTC with SPN 64072 and FMI if The received physical
(engineering) value of CAN signal RESS Max Charging Power is below a
threshold ( 100W )
[prod-fltdtc-175 EVCC shall set a J1939 DTC with SPN 64073 and FMI if Configuration for port
DC measurement is set to available and the received physical (engineering)
value of CAN signal DC voltage measured by EV at the charge inlet is above a
threshold ( 1500V )
[prod-fltdtc-176 EVCC shall set a J1939 DTC with SPN 64073 and FMI if Configuration for port
DC measurement is set to available and the received physical (engineering)
value of CAN signal DC voltage measured by EV at the charge inlet is below a
threshold ( 0V )
[prod-fltdtc-177 EVCC shall set a J1939 DTC with SPN 64074 and FMI if Configuration for port
DC measurement is set to available and the received physical (engineering)
value of CAN signal DC current measured by EV at the charge inlet is above a
threshold ( 800A )
[prod-fltdtc-178 EVCC shall set a J1939 DTC with SPN 64074 and FMI if Configuration for port
DC measurement is set to available and the received physical (engineering)
value of CAN signal DC current measured by EV at the charge inlet is below a
threshold ( -800A )
[prod-fltdtc-179 EVCC shall set a J1939 DTC with SPN 64077 and FMI if The received physical
(engineering) value of CAN signal RESS Total Energy is above a threshold
( 1000000Wh )
[prod-fltdtc-180 EVCC shall set a J1939 DTC with SPN 64077 and FMI if The received physical
(engineering) value of CAN signal RESS Total Energy is below a threshold
( 1000Wh )
[prod-fltdtc-181 EVCC shall set a J1939 DTC with SPN 64078 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD1 is
above a threshold ( 1NU )
[prod-fltdtc-182 EVCC shall set a J1939 DTC with SPN 64078 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD1 is
below a threshold ( 0NU )
[prod-fltdtc-183 EVCC shall set a J1939 DTC with SPN 64079 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD2 is
above a threshold ( 1NU )
[prod-fltdtc-184 EVCC shall set a J1939 DTC with SPN 64079 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD2 is
below a threshold ( 0NU )
[prod-fltdtc-185 EVCC shall set a J1939 DTC with SPN 64080 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD3 is
above a threshold ( 1NU )
[prod-fltdtc-186 EVCC shall set a J1939 DTC with SPN 64080 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD3 is
below a threshold ( 0NU )
[prod-fltdtc-187 EVCC shall set a J1939 DTC with SPN 64081 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD4 is
above a threshold ( 1NU )
[prod-fltdtc-188 EVCC shall set a J1939 DTC with SPN 64081 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD4 is
below a threshold ( 0NU )
[prod-fltdtc-189 EVCC shall set a J1939 DTC with SPN 64082 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD5 is
above a threshold ( 1NU )
[prod-fltdtc-190 EVCC shall set a J1939 DTC with SPN 64082 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output LSD5 is
below a threshold ( 0NU )
[prod-fltdtc-191 EVCC shall set a J1939 DTC with SPN 64083 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output HSD1 is
above a threshold ( 1NU )
[prod-fltdtc-192 EVCC shall set a J1939 DTC with SPN 64083 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output HSD1 is
below a threshold ( 0NU )
[prod-fltdtc-193 EVCC shall set a J1939 DTC with SPN 64084 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output HSD2 is
above a threshold ( 1NU )
[prod-fltdtc-194 EVCC shall set a J1939 DTC with SPN 64084 and FMI if The received physical
(engineering) value of CAN signal for desired state of digital output HSD2 is
below a threshold ( 0NU )
[prod-fltdtc-195 EVCC shall set a J1939 DTC with SPN 64085 and FMI if The received physical
(engineering) value of CAN signal Hbridge 1 Direction Commmand is above a
threshold ( 3NU )
[prod-fltdtc-196 EVCC shall set a J1939 DTC with SPN 64085 and FMI if The received physical
(engineering) value of CAN signal Hbridge 1 Direction Commmand is below a
threshold ( 0NU )
[prod-fltdtc-197 EVCC shall set a J1939 DTC with SPN 64087 and FMI if The received physical
(engineering) value of CAN signal Hbridge 1 Dutycycle Commmand is above a
threshold ( 100% )
[prod-fltdtc-198 EVCC shall set a J1939 DTC with SPN 64087 and FMI if The received physical
(engineering) value of CAN signal Hbridge 1 Dutycycle Commmand is below a
threshold ( 0% )
[prod-fltdtc-199 EVCC shall set a J1939 DTC with SPN 64089 and FMI if The received physical
(engineering) value of CAN signal EV minimum charging current limit is above
a threshold ( 1500A )
[prod-fltdtc-200 EVCC shall set a J1939 DTC with SPN 64089 and FMI if The received physical
(engineering) value of CAN signal EV minimum charging current limit is below
a threshold ( 0A )
[prod-fltdtc-201 EVCC shall set a J1939 DTC with SPN 64090 and FMI if The received physical
(engineering) value of CAN signal EV minimum charging power limit is above a
threshold ( 1000000W )
[prod-fltdtc-202 EVCC shall set a J1939 DTC with SPN 64090 and FMI if The received physical
(engineering) value of CAN signal EV minimum charging power limit is below a
threshold ( 0W )
[prod-fltdtc-203 EVCC shall set a J1939 DTC with SPN 64091 and FMI if The received physical
(engineering) value of CAN signal EV maximum discharge current limit is
above a threshold ( 1500A )
[prod-fltdtc-204 EVCC shall set a J1939 DTC with SPN 64091 and FMI if The received physical
(engineering) value of CAN signal EV maximum discharge current limit is
below a threshold ( 0A )
[prod-fltdtc-205 EVCC shall set a J1939 DTC with SPN 64092 and FMI if The received physical
(engineering) value of CAN signal EV minimum discharge current limit is
above a threshold ( 1500A )
[prod-fltdtc-206 EVCC shall set a J1939 DTC with SPN 64092 and FMI if The received physical
(engineering) value of CAN signal EV minimum discharge current limit is
below a threshold ( 0A )
[prod-fltdtc-207 EVCC shall set a J1939 DTC with SPN 64093 and FMI if The received physical
(engineering) value of CAN signal EV maximum discharge power limit is above
a threshold ( 1000000W )
[prod-fltdtc-208 EVCC shall set a J1939 DTC with SPN 64093 and FMI if The received physical
(engineering) value of CAN signal EV maximum discharge power limit is below
a threshold ( 0W )
[prod-fltdtc-209 EVCC shall set a J1939 DTC with SPN 64094 and FMI if The received physical
(engineering) value of CAN signal EV minimum discharge power limit is above
a threshold ( 1000000W )
[prod-fltdtc-210 EVCC shall set a J1939 DTC with SPN 64094 and FMI if The received physical
(engineering) value of CAN signal EV minimum discharge power limit is below
a threshold ( 0W )
[prod-fltdtc-211 EVCC shall set a J1939 DTC with SPN 64095 and FMI if The received physical
(engineering) value of CAN signal EV minimum voltage limit is above a
threshold ( 1500V )
[prod-fltdtc-212 EVCC shall set a J1939 DTC with SPN 64095 and FMI if The received physical
(engineering) value of CAN signal EV minimum voltage limit is below a
threshold ( 0V )
[prod-fltdtc-213 EVCC shall set a J1939 DTC with SPN 64096 and FMI if The received physical
(engineering) value of CAN signal EV energy request is above a threshold
( 1000000Wh )
[prod-fltdtc-214 EVCC shall set a J1939 DTC with SPN 64096 and FMI if The received physical
(engineering) value of CAN signal EV energy request is below a threshold ( -
1000000Wh )
[prod-fltdtc-215 EVCC shall set a J1939 DTC with SPN 64097 and FMI if The received physical
(engineering) value of CAN signal EV RESS Maximum Energy is above a
threshold ( 1000000Wh )
[prod-fltdtc-216 EVCC shall set a J1939 DTC with SPN 64097 and FMI if The received physical
(engineering) value of CAN signal EV RESS Maximum Energy is below a
threshold ( 0Wh )
[prod-fltdtc-217 EVCC shall set a J1939 DTC with SPN 64098 and FMI if The received physical
(engineering) value of CAN signal EV RESS Minimum Energy is above a
threshold ( 1000000Wh )
[prod-fltdtc-218 EVCC shall set a J1939 DTC with SPN 64098 and FMI if The received physical
(engineering) value of CAN signal EV RESS Minimum Energy is below a
threshold ( 0Wh )
[prod-fltdtc-219 EVCC shall set a J1939 DTC with SPN 64099 and FMI if The received physical
(engineering) value of CAN signal EV RESS Bulk State Of Charge is above a
threshold ( 100% )
[prod-fltdtc-220 EVCC shall set a J1939 DTC with SPN 64099 and FMI if The received physical
(engineering) value of CAN signal EV RESS Bulk State Of Charge is below a
threshold ( 10% )
Fault Abbreviation
Out Of Range High OORH
Out Of Range Low OORL
Out of Correlation OOC
Short Circuit to battery SCB
Short Circuit to ground SCG
Open Load OPL
Overcurrent OVC
CAN Receive Timeout Error CTO
Slew Rate high SLH
Rationality RAT
Out Of Bound High OOBH
Out Of Bound Low OOBL
CAN Receive Overrun Error COR
CAN Receive Checksum Error CSM
CAN Recieve Error CRE
CAN Receive Counter Sequence Violation CSQ
V2G message receive Timeout VMTO
V2G message receive Sequence Timeout VSTO
V2G message receive Sequence Violation VSEQ
V2G message with FAIL Responsecode VFAIL
PWM in Timeout PWMTO
Slow Flash
Malfunction Indicator Lamp when this DTC is active M0
Red Stop Lamp when this DTC is active R0
Amber Warning Lamp when this DTC is active A0
Protection Lamp when this DTC is active P0
MIL - Malfunction Indicator Lamp This lamp is only illuminated when there is an emission-related tr
RSL - Red Stop Lamp This lamp is used to relay trouble code information that is of a se
AWL - Amber Warning Lamp This lamp is used to relay trouble code information that is reporti
PL - Protect Lamp This lamp is used to relay trouble code information that is reporti
Comment
Raw value is out of range High
Raw value is out of range Low
Mismatch among the values of one variable that are aquired from different sources
Short Circuit to battery was detected on the ECU output pin
Short Circuit to ground was detected on the ECU output pin
Commanded output does not match with the feedback from output pin
Current or Tepmerature is Higher than Normal
An expected CAN Message was not received during a certain time
The absolute slew rate of the analog signal is higher than a positive threshold
Faults issued based on Rationality check
Engineering value is out of bounds High
Engineering value is out of bounds Low
Overrun error detected for the received CAN message, message is received more than once during one sampling time
Checksum error detected for the received CAN message
error occurred when Receiving the CAN Message
The sequence of Counter signal inside the CAN message is not valid
V2G Message Timeout: During the charging session, the expected V2G response message was not received within an accepta
V2G Sequence Timeout: During the charging session, an expected sequence of events was not completed within an acceptabl
V2G Sequence Violation: During the charging session, the received V2G message is not the expected respsone
V2G Fail: During the charging session, the responsecode signal in this V2G message equals to FAIL
PWM Timeout (PWM waveform cannot be detected)
On Off
M2 M3
R2 R3
A2 A3
P2 P3
be immediately stopped.
ectronic sub-system related. For instance, engine coolant temperature is exceeding its prescribed temperature range.
FMI Description
0 Data Valid But Above Normal Operational Range - Most Severe Level
1 Data Valid But Below Normal Operational Range - Most Severe Level
2 Data Erratic, Intermittent Or Incorrect
3 Voltage Above Normal, Or Shorted To High Source
4 Voltage Below Normal, Or Shorted To Low Source
5 Current Below Normal Or Open Circuit
6 Current Above Normal Or Grounded Circuit
7 Mechanical System Not Responding Or Out Of Adjustment
8 Abnormal Frequency Or Pulse Width Or Period
9 Abnormal Update Rate
10 Abnormal Rate Of Change
11 Root Cause Not Known
12 Bad Intelligent Device Or Component
13 Out Of Calibration
14 Special Instructions
15 Data Valid But Above Normal Operating Range - Least Severe Level
16 Data Valid But Above Normal Operating Range - Moderately Severe Level
17 Data Valid But Below Normal Operating Range - Least Severe Level
18 Data Valid But Below Normal Operating Range - Moderately Severe Level
19 Received Network Data In Error
20 Data Drifted High
21 Data Drifted Low
31 Condition Exists
ature range.