Embedded Solutions

for Transportation and Industrial Markets


www.men.de/products/02F603-.html

F603 – 3U CompactPCI® Side Card USB/COM

n 4 HP extension for 3U Intel® SBCs F14, F15,


F17, F18, F19P, F21P
n 1 RS232
n 2 USB 2.0
n 2.5" SATA hard-disk slot
n CompactFlash® slot

The F603 is a 4HP mixed USB/COM extension card for Thus, the F603 provides one COM interface as well as two more USB
3U Intel® based CompactPCI® single-board computers. 2.0 interfaces that extend the Single-Board Computer functionality to 4
It can be used in combination with the F14 and USB ports at the front panel.
compatible CPU boards. In addition an onboard 2.5" SATA hard-disk slot and a CompactFlash®
Modern Intel® based boards increasingly support USB slot is available on the F603.
interfaces as an exclusive universal connection of The F603 is directly plugged to the right side of the respective single-
devices such as keyboard, mouse, CD-ROM, floppy etc. board computer. A robust connector makes for high mechanical
Especially in industrial applications however many stability. It is delivered with an 8HP front panel, replacing the 4HP front
existing systems still use legacy I/O. panel of a 3U single-board computer and thus resulting in a solid one-
piece front panel.

Diagram

F603 Data Sheet / 2012-04-02 Page 1


Embedded Solutions
for Transportation and Industrial Markets
www.men.de/products/02F603-.html

Technical Data

I/O n USB
o Two USB 2.0 ports

o Series A connector at front panel

o UHCI implementation

o Data rates up to 480Mbit/s

o High current up to 1A

n UART
o One RS232 at front panel

o Data rates 300bit/s..230kbit/s (up to 1 Mbit/s with shielded cable)

o FIFO receive and transmit buffers for high data throughput

o Handshake lines: full support

Mass Storage n Serial ATA (SATA)


o One port for onboard 2.5" hard-disk drive

o Transfer rates up to 150MB/s (depends on hard disk)

o RAID level 0/1 support (depends on CPU board)

n CompactFlash® card interface


o Via USB to PATA converter

o Type I

o True IDE mode

o Multiword DMA 2 and UDMA 4 support

n Please note that operating systems which cannot boot from removable data carriers (e.g. Windows® XP)
cannot boot from the CompactFlash® over USB

Miscellaneous n CompactPCI® J1 is assembled for increased mechanical stability and/or for power supply

Electrical Specifications n Supply voltage/power consumption:


o +5V (-3%/+5%), 50mA typ. (w/o hard disk)

o +3.3V (-3%/+5%), 95mA typ. (w/o hard disk)

n MTBF: tbdh @ 40°C according to IEC/TR 62380 (RDF 2000)

Mechanical Specifications n Dimensions: conforming to CompactPCI® specification for 3U boards


n Mountable on right (standard) or left (option) side of the CPU
n Weight: 130g (w/o hard disk and CompactFlash®)

Environmental Specifications n Temperature range (operation):


o 0..+60°C up to -40..+85°C (depending on hard disk; please refer to the hard disk specifications for

possible limits)
o Airflow: min. 10m³/h

n Temperature range (storage): -40..+85°C


n Relative humidity (operation): max. 95% non-condensing
n Relative humidity (storage): max. 95% non-condensing
n Altitude: -300m to + 3,000m
n Shock: 15g/11ms
n Bump: 10g/16ms
n Vibration (sinusoidal): 2g/10..150Hz
n Conformal coating on request

Safety n PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers

EMC n Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)

Software Support n Driver software can be found in the data sheet of the CPU board that you use.

F603 Data Sheet / 2012-04-02 Page 2


Embedded Solutions
for Transportation and Industrial Markets
www.men.de/products/02F603-.html

Configuration & Options

Standard Configurations

Article No. Interfaces Mass Storage Position Operation Temperature

02F603-00 1 COM, 2 USB 2.0 SATA HD and right of CPU 0..+60°C


CompactFlash

Options

Mass storage n Second CompactFlash® interface instead of SATA hard disk


o Via AD95 adapter

Mechanical n Mounting of side card on left side of the CPU

Operation Temperature n 0..+60°C


n -40..+85°C

Please note that some of these options may only be available for large volumes. Please ask our sales staff for more information.

Ordering Information

Standard F603 Models 02F603-00 3U CompactPCI® side card with 2 USB and 1 COM extension, SATA hard disk and
CompactFlash® slot, for F14 and compatible SBCs, mounted to the right of the SBC,
0..+60°C

Memory 0751-0028 CompactFlash® card, 2 GB, Type I, -40..+85°C, S.M.A.R.T. interface

0751-0060 CompactFlash® card, 16 GB, -40..+85°C

Miscellaneous Accessories 0710-0038 HDD SATA 2.5", 100 GB, 1.5GB/s, 4200rpm, -10°..+70°C

Documentation Compare Chart 3U CompactPCI® / PlusIO CPU cards » Download

Compare Chart 3U CompactPCI® / PlusIO peripheral cards » Download

Compare Chart 3U CompactPCI® / PlusIO extension cards » Download

For more information on the interoperability of the side cards with the respective CPU boards please see the
extension card compatibility matrix (PDF)

20F603-00 F603 User Manual

F603 Data Sheet / 2012-04-02 Page 3


Embedded Solutions
for Transportation and Industrial Markets
www.men.de/products/02F603-.html

Contact Information

Germany France USA

MEN Mikro Elektronik GmbH MEN Mikro Elektronik SAS MEN Micro Inc.
Neuwieder Straße 3-7 18, rue René Cassin 860 Penllyn Blue Bell Pike
90411 Nuremberg ZA de la Châtelaine Blue Bell, PA 19422
Phone +49-911-99 33 5-0 74240 Gaillard Phone (215) 542-9575
Fax +49-911-99 33 5-901 Phone +33 (0) 450-955-312 Fax (215) 542-9577
Fax +33 (0) 450-955-211

[email protected] [email protected] [email protected]


www.men.de www.men-france.fr www.menmicro.com

The date of issue stated in this data sheet refers to the Technical Data only. Changes in ordering information given herein do not affect the date of issue. All brand or product names are
trademarks or registered trademarks of their respective holders.
MEN is not responsible for the results of any actions taken on the basis of information in the publication, nor for any error in or omission from the publication.
MEN expressly disclaims all and any liability and responsibility to any person, whether a reader of the publication or not, in respect of anything, and of the consequences of anything,
done or omitted to be done by any such person in reliance, whether wholly or partially, on the whole or any part of the contents of the publication.
The correct function of MEN products in mission-critical and life-critical applications is limited to the environmental specification given for each product in the technical user manual.The
correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product
for the applicable use case and has to be agreed upon in writing by MEN and the customer.Should the customer purchase or use MEN products for any unintended or unauthorized
application, the customer shall indemnify and hold MEN and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses,
and reasonable attorney fees arising out of, directly or indirectly, any claim or personal injury or death associated with such unintended or unauthorized use, even if such claim alleges
that MEN was negligent regarding the design or manufacture of the part.
In no case is MEN liable for the correct function of the technical installation where MEN products are a part of.

Copyright © 2015 MEN Mikro Elektronik GmbH. All rights reserved.

F603 Data Sheet / 2012-04-02 Page 4

You might also like