Ir3300 017

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Service Bulletin COPIER

Issued by Canon Europa N.V.

Model : iR2200-3300/2200i-3300i No.: iR3300-017


(FF-T01-L5-000011-02)
DATE: 25.10.02

Location : Hard Disk Drive

Subject : Information of E602 troubleshooting

Reason : This bulletin notifies of servicing procedure to be followed if E602 error (HD-related error) occurred on an
iR machine

Details :
E602 errors on iR machines are classified into the following errors by the subcode and corresponding cause:

(1) E602-0001
A HD mount error was detected when the HD was started up.

(2) E602-0002
A HD data read error was detected when the HD was started up.

(3) E602-0003
The data address registered on the HD is not consistent with the data. (Write-abort error on HD sector)

(4) E602-0004
An error occurs by checking the Control Table of “Image storage area” when the machine is “ON”.
(See Note: 3)

Trouble shooting of each sub code is as follows.


(1) E602-0001
Check the faulty connection between the HDD and the main controller PCB
Poor HDD : Replace the HDD, and reinstall System Software
Poor Main Controller PCB : Replace the main controller PCB

(2) E602-0002
System Software is not installed properly : Reinstall System Software

-1/4-
iR3300-017

(3) E602-0003
The following 4 partitions exist in the HDD of the iR models, and countermeasure differs depending
on whether Write-Abort occurs in the area.
(Note) Partitions on iR machine

1) Image storage area


Saves and stores image data.
2) General-purpose file storage area
Stores user setting data, various log data, PDL spool data, and image data address.
3) PDL-related file storage area
Stores font data for printers.
4) Firmware storage area
Stores system software.

(a) If write to the image storage area was aborted


A function is implemented to fix a write-abort error in the image storage area, which automatically
repairs the error after power is turned off and switched on again. (The function writes dummy data at
locations specified by the data pointer to fix address-data inconsistency.)
If a write-abort error occurred in the image storage area and E602-0003 is output, turn off the main
power and then turn it on again to fix the error. (See Note 1.)

(b) If write to other areas than the image storage area was aborted
If write to other areas than the image storage area was aborted, the automatic recovery function is unable
to fix it. Follow the procedure below to manually recover the sector.

(i) If the machine can be entered service mode


- Enter service mode and set "0" for COPIER > FUNCTIONS > SYSTEM > HD-CHECK.
(This will check and recover the entire sectors on the HD.) (This takes about 20 to 40 minutes depending on
the HD capacity.)
- After executing HD-CHECK, turn the power off and turn it on again to check that the HD starts up
normally. If the HD fails to start up, set "1" and then "2" for HD-CLEAR. ("1" initializes the image storage
area; "2" the general-purpose file storage area.)
- After recovering from the write-abort error, reinstall system software. (System reinstallation is
recommended, as there is possibility that the sector fails to return in a proper state after
auto-recovery of Write Abort sector)

(ii) If the machine cannot enter service mode


E602-0003 may appear after power-on on a machine in a state incapable of entering service mode.
(This occurs if write-abort error is detected during self-diagnosis after power-on.)
In this case, turn on the main power while holding down digit keys 1 and 9 at the same time. This
activates a function that is equivalent to setting "0" for HD-CHECK in service mode.
After calling up the function, see "If the machine can enter service mode" above and do as you do
after entering service mode.

(4) E602-0004
(a) In case recovery is possible, indicate the service error E602-0004 on the screen once, and turn
“OFF” and “ON” the machine to recover
(b) In case recovery is impossible, the service error E602-0004 appears all the time on the screen :
Replace the HDD and reinstall System Software

-2/4-
iR3300-017

Remarks :
(1) Causes of write-abort errors
As a rule, write-abort error results from inconsistency between the address (data pointer) and the data.
The address-data consistency is broken by turning power off at illegal timings.

iR machines access their HD at the timings below, not to mention when copying and/or writing of PDL data.
If the main power is turned off coinciding with any of the following events, the E602-0003 error occurs.

i) 150 ms of initial process within 1 minute after a job


An iR machine performs internal process in the main unit for a duration of 150 ms at undetermined timing
within 1 minute after completion of a copy/fax/print job. (During the internal process in the main unit, the
controller accesses the image data address files on the HD.)

At what point in the 1-minute time span the process starts is undetermined. If the main power is turned on
during the 150 ms, The E602-0003 code may appear when the power is turned on next time.

ii) 19 ms of inquiry from NetSpot


If an inquiry for job history information is sent from NetSpot on a PC to the copier, the HD makes writing
operation for about 19 ms. Turning off the main power within this duration may cause E602-0003 when the power
is turned on next time.

iii) Operation of remote UI


The HD makes writing operation also when remote UI is working. Turning off the main power within the duration
may cause E602-0003 when the power is turned on next time.

(2) Maintenance functions in service mode


Checking and initializing the whole HDD or each partition of the 4 are possible from the following
menus in service mode.
COPIER->FUNCTION->SYSTEM->CHK-TYPE : Specifying affected area
COPIER->FUNCTION->SYSTEM->HD-CHECK : Checking HDD or partitions
COPIER->FUNCTION->SYSTEM->HD-CLEAR : Initializing partitions

CHK-TYPE HD-CHECK HD-CLEAR


0(The whole disk) Faulty sector check and recovery (No function)
1(Area to accumulate image) Compatibility check Initialization
2(Area to store general-purpose files) Compatibility check Initialization
3(Area to store PDL related files) Compatibility check Initialization
4(Area to store Firmware) Compatibility check (No function)
Operation Procedure: Follow the chart above, and specify the area you wish to process with
CHK-TYPE. Carry out HD-CHECK when checking compatibility,
and HD-CLEAR when performing initialization.

※ System reinstallation is recommended after auto-recovery of sector with HD-CHECK


(CHK-TYPE=0), as there is possibility that sector fails to return in a proper state.
※ If initializing “Image storage area” is carried out with HD-CLEAR (CHK-TYPE=1),
all images accumulated in HDD are deleted.

(3) Prevention measures against E602-003/004


It is recommended to turn “OFF” the control panel, and put the machine in sleep mode before
turning “OFF” the main power as prevention measures against E602-003/004. (for reduce the HDD load)

-3/4-
iR3300-017

Cautions :
(1) Note 1: Automatic recovery from write-abort error in the image storage area by main power off/on
This function is supported by the following versions of system software:
iR2200 : v6.01 or later
Other models : Initial mass-production versions

(2) Note 2: Recovery of sectors by holding down 1+9 during power-on


This function is supported by the following versions of boot ROM:
v7.25

(3) Note 3: About E602-0004


As a result of the report “Incapability of booting up caused by HDD trouble” from the field,
it was found out that the Control Table of “Image storage area” had been crashed.
In case the Control Table is crashed, abnormal operations occur when checking
compatibility during boot-up or when accessing files after boot-up.
To reinforce prevention of the abnormal operations, software is modified to process the
detailed check of the control table of “Image storage area” when the machine is “ON”.
The indication appears if an error occurs during the check.

This function is supported by the following System Software versions or later:


iR2200-3300 : v31.04 or later
Other models : supported from version manufactured at the initial volume production