Introduction
Trane Air Rotation Units (ARU)
Trane air rotation units are the ideal solution for heating and cooling large open spaces. Air rotation units
are the perfect product for conditioning warehouses, fulfillment centers, and manufacturing facilities.
Air rotation units eliminate stratification, eliminate roof tops units, reduce building structural steel, lower
maintenance and energy costs, and provide complete temperature control.

Additional Air Rotation Benefits


• Elimination of RTUs
• Less structural support on roof
• Units maintained at floor level: coils and filters
• Limited unit static = Lower fan BHP
• Even temperatures in space for valuable product
• Eliminates maintenance and installation associated with ductwork
• Available in four cabinet sizes: A, B, C, D

Copyright
This document and the information in it are the property of Trane, and may not be used or reproduced in
whole or in part without written permission. Trane reserves the right to revise this publication at any time,
and to make changes to its content without obligation to notify any person of such revision or change.

Trademarks
All trademarks referenced in this document are the trademarks of their respective owners.

©2022 Trane PKG-PRC025A-EN


Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Trane Air Rotation Units (ARU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Heating and Cooling Cabinet (B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Heating and Cooling Cabinet (C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Heating and Cooling Cabinet (D) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

PKG-PRC025A-EN 3
Features and Benefits
Standard Features
• Indoor Units
• 4,000 to 108,000 CFM Range
• Chilled Water or DX Cooling
• Indirect Fired Gas Heat
• Direct Drive Propeller Fans
• Two Inch Foam Panel Construction
• Aluminum Tubular Framing
• Sloped Drain Pans to ensure complete condensate removal for IAQ
• Single Point Power
• Fully integrated, Factory-installed, and Commissioned controls
• Trane Variable Frequency Drive
• Hinged Access Doors

Other Benefits
• Outdoor Units
• Outside Air Conditioned Through the ARU
• Economizer Operation
• Additional Heating Options
• Custom Filtration for IAQ
• Custom Unit Heights
• Airfoil Supply Air Diffusers
• Stainless Steel Sloped Drain Pan
• DDC Controls
• Painted Exterior – Custom Colors

4 PKG-PRC025A-EN
Model Number Description
Digits 1, 2, 3 - Unit Model Digit 23 - Controls Options Digits 32-39
ARU = Air Rotation Unit 0 = None Reserved for future expansion
1 = Stand Alone
Digit 4, 5 - Design Sequence 2 = DDC
Digit 40
AA 0= N/A
Digit 24 - Dampers S = Design Special
Digits 6 - Base Size 0 = None
A=5x5 1 = Econo Split
B=9x7 2= Full Eco
C = 13 x 7 3= OA
D = 17 x 7
Z = Custom Digit 25 - Grilles
S= Stamped
Digit 7, 8, 9 - KCFM A = Airfoil
D = Ducted
Digit 10 - Mode Digit 26 - Discharge Module
C = Cooling 0 = No
H = Heating 1 = Yes
B = Both
Digit 27 - Paint
Digits 11, 12, 13, 14 - MBH 0=No
1= Yes
Digit 15 - Indoor/Outdoor Digit 28 - Drain Pan
I = Indoor G= Galvanized
O = Outdoor S= Stainless
Digit 16 - Voltage Digit 29 - Filter Type
A = 208V/230V A = 2" MERV 8
B = 460V B = 2" MERV 13
C = 575V C = Custom
Digit 17 - Coil Type Digit 30- Grill Config
1 = CW 1
2 = DX 2
Digit 18, 19, 20 - Tonnage 3
4
Digit 31 - Unit Height
Digit 21 - Fan Size
A = 17’ Cooling only
1 = 36"
B = 25'
2 = 54"
C = Custom
C = Custom
Digit 22 - Fan Quantity

PKG-PRC025A-EN 5
Performance Data
Table 1. Heating and cooling cabinet (A)

Cooling Performance

Cooling Type CW or DX

Tonnage Range (Tons) See Factory

Number of Coils See Factory

Fan Performance

Fan Type See Factory

CFM Range See Factory

Number of Fans See Factory

Number of VFDs See Factory

Fan Horse Power Range (per fan) See Factory

Fan Diameter (per fan) See Factory

Heating Performance

Heater Type Indirect

Number of Heaters (minimum/maximum) 1 to 2

Gas Type LP or NG

Turndown (minimum/maximum) 2:1 / 4:1

Heating Input (minimum/maximum) 200 / 200

Filters

Type Furnished MERV 8

Filter Dimensions 25" W x 16" H x 2" D

Electrical (Based on Heating and Cooling Unit)

MCA (minimum/maximum) 460v See Factory

MOP (minimum/maximum) 460v See Factory

MCA (minimum/maximum) 208v See Factory

MOP (minimum/maximum) 208v See Factory

6 PKG-PRC025A-EN
Performance Data

Table 2. Heating and cooling cabinet (B)

Cooling Performance

Cooling Type CW or DX

Tonnage Range (Tons) 80 to 160

Number of Coils 2

Fan Performance

Fan Type Direct Drive Prop

CFM Range 25,000 to 54,000

Number of Fans 1

Number of VFDs 1

Fan Horse Power Range (per fan) 20 to 30 HP

Fan Diameter (per fan) 36" or 54"

Heating Performance

Heater Type Indirect

Number of Heaters (minimum/maximum) 2 to 3

Gas Type LP or NG

Turndown (minimum/maximum) 4:1 to 15:1

Heating Input (minimum/maximum) 1200 / 1800

Filters

Type Furnished MERV 8

Filter Dimensions 25" W x 16" H x 2" D

Electrical (Based on Heating and Cooling Unit)

MCA (minimum/maximum) 460v 39 / 57

MOP (minimum/maximum) 460v 60 / 90

MCA (minimum/maximum) 208v 82 / 125

MOP (minimum/maximum) 208v 125 / 200

PKG-PRC025A-EN 7
Performance Data

Table 3. Heating and cooling cabinet (C)

Cooling Performance

Cooling Type CW or DX

Tonnage Range (Tons) 160 to 240

Number of Coils 2

Fan Performance

Fan Type Direct Drive Prop

CFM Range 55,000 to 86,000

Number of Fans 2

Number of VFDs 2

Fan Horse Power Range (per fan) 20 to 25 HP

Fan Diameter (per fan) 36" or 54"

Heating Performance

Heater Type Indirect

Number of Heaters (minimum/maximum) 4 to 5

Gas Type LP or NG

Turndown (minimum/maximum) 20:1 to 25:1

Heating Input (minimum/maximum) 2400 / 3000

Filters

Type Furnished MERV 8

Filter Dimensions 25" W x 16" H x 2" D

Electrical (Based on Heating and Cooling Unit)

MCA (minimum/maximum) 460v 76 / 96

MOP (minimum/maximum) 460v 90 / 110

MCA (minimum/maximum) 208v 164 / 212

MOP (minimum/maximum) 208v 200 / 250

8 PKG-PRC025A-EN
Performance Data

Table 4. Heating and cooling cabinet (D)

Cooling Performance

Cooling Type CW or DX

Tonnage Range (Tons) 240 to 300

Number of Coils 2

Fan Performance

Fan Type Direct Drive Prop

CFM Range 87,000 to 108,000

Number of Fans 2

Number of VFDs 2

Fan Horse Power Range (per fan) 25 to 30 HP

Fan Diameter (per fan) 36" or 54"

Heating Performance

Heater Type Indirect

Number of Heaters (minimum/maximum) 6

Gas Type LP or NG

Turndown (minimum/maximum) 20:1 to 30:1

Heating Input (minimum/maximum) 3600

Filters

Type Furnished MERV 8

Filter Dimensions 25" W x 16" H x 2" D

Electrical (Based on Heating and Cooling Unit)

MCA (minimum/maximum) 460v 96 / 111

MOP (minimum/maximum) 460v 110 / 125

MCA (minimum/maximum) 208v 212 / 245

MOP (minimum/maximum) 208v 250 / 300

PKG-PRC025A-EN 9
Dimensions
Heating and Cooling Cabinet (B)
Figure 1. Indoor heat and cool

WEIGHT: 6043.41 LBS


124.54

108.60

A
MOD 4
60.89 53.65

MOD 3 HEATER
26'-6 4 "
1

MOD 2 SA FAN
101.64

MOD 1 COILS
102.06

FILTERS DOOR
A SECTION A-A

Figure 2. Indoor cooling

124.54

WEIGHT: 3888.19 LBS


89.73

SA FAN
MOD 2
101.64
16'-11 8 "
5

COILS
MOD 1
102.00

FILTERS DOOR
A
SECTION A-A

Note: Standard dimensions shown. Spacer modules available for extended unit heights with
2, 6, and 10 feet options.

10 PKG-PRC025A-EN
Dimensions

Heating and Cooling Cabinet (C)


Figure 3. Indoor heat and cool

5
108 8 "

167 8 "
3

A
GRILLS
101 5/8"

MODULE 4

MODULE 3 HEATERS
61"
30'-6 4 "
1

101 5/8"

MODULE 2 SA FAN

MODULE 1

COILS
102"

ELEC. FILTERS
BOX DRAIN SECTION A-A
A

Figure 4. Indoor cooling

3
89 4 "
167 8 "
3

A
GRILLS
101 5/8"

MODULE 2 SA FANS
16'-11 8 "
5

MODULE 1
COILS
102"

ELEC.
BOX DRAIN A FILTERS SECTION A-A

Note: Standard dimensions shown. Spacer modules available for extended unit heights with
2, 6, and 10 feet options.

PKG-PRC025A-EN 11
Dimensions

Heating and Cooling Cabinet (D)


Figure 5. Indoor heat and cool

5
108 8 "

218 4 "
1

A
GRILLS
101.63

MODULE 4

HEATERS
60.89

MODULE 3
30'-6"

SA FANS
MODULE 2
101.63

COILS
MODULE 1
102.00

FILTERS
ELEC.
BOX SECTION A-A
A

Figure 6. Indoor cool

3
89 4 "
218 4 "
1

A GRILLS

SA FANS
101.63

MODULE 2
16'-11 5/8"

COILS
MODULE 1
102.00

FILTERS
ELEC.
BOX A SECTION A-A

Note: Standard dimensions shown. Spacer modules available for extended unit heights with
2, 6, and 10 feet options.

12 PKG-PRC025A-EN
Weights
Table 1. ARU heating and cooling weights (based on catalog drawing)

Model Number Total Unit Weights - Cooling Only Total Unit Weight (lbs) - Heating and Cooling

ARU A See Factory See Factory

ARU B 4,889 6,044

ARU C 6,630 10,273

ARU D 8,800 13,420

PKG-PRC025A-EN 13
Mechanical Specifications
General
ARU Construction Section Includes:
• Cabinet
– Access Doors
– Structural Base
• Propeller Fans
– Motors
– VFD
• Chilled Water Coils
• DX Coils
• Gas Heaters
• Dampers
• Filters
• Air Distribution Grilles
• Controls

Cabinet
• Unit structure is constructed of an extruded aluminum tubular framing system.
• Structural panel construction consists of a 2-inch thick insulating foam core with R-14 insulation value
surrounded on both sides by water resistant stabilizers sandwiched between aluminum sheets with
an exterior painted finish.

Access Doors
The unit access doors are constructed of the same insulating panels as the rest of the unit and are
designed to match the construction of the unit. Access doors are hinged and swing out for proper access.
A secondary safety door will be installed if immediate danger is present past the access door. The safety
door shall require tools to bypass.

Structural Bases
The unit base frame is constructed from structural steel c-channel around the entire perimeter of the unit
and is provided with intermediate structural steel members, channel, and angle iron as required to support
all internal components. All tubing, channel, lift lugs, and angle joints are metal inert gas welded.

Propeller Fans
• Direct drive propeller fans for increased efficiency.
• Aluminum anti-sparking blades.
• Dynamic balancing as an assembly.

Motors
Direct drive propeller fans are provided with high efficiency totally enclosed, fan-cooled (TEFC) electric
motors.

Variable Frequency Drives (VFDs)


Propeller fans are equipped with Trane vfds. Integral disconnect and primary fusing. Variable frequency
drives and are tested in the factory for reliable startup.

14 PKG-PRC025A-EN
Mechanical Specifications

Chilled Water Coils


• Chilled water coils are of the aluminum plate ripple fin 0.006 inches extended surface rated in
accordance with AHRI 410 for water, steam, or ethylene/propylene glycol water mixture. The tubes
are 5/8 inch and have a minimum 0.017-inch wall thickness or 1/2 inch tube 0.016 wall thickness.
Seamless copper expanded into the fin collars to provide a permanent mechanical bond. Coil headers
shall be non-ferrous seamless copper, and provided with brass or copper pipe connections. Each coil
is provided with capped vent and drain connections. All coils are fully drainable with no trapped tubes.
• Coil casings are G90 galvanized steel with formed 1-1/2 inch flanges on all sides of the coil.
• All coils are leak tested under water at 350 psig and rated for 250 psig working pressures.
• Coil supply and return piping connections extending through the cabinet wall is sealed by rubber
grommets with caulking on the exterior of the casing.

DX Coils
• The tubes are 1/2 inch tube with 0.016 wall thickness. Coil casings are G90 galvanized steel with
formed 1-1/2 inch flanges on all sides of the coil with the tube sheets having pressed or extruded tube
holes. The coil casing is reinforced so that the maximum unsupported length is 44 inches. The
reinforcements are of the same material as the casing.
• All coils are safety listed with 750 psig rating.
• Coil supply and return piping connections extending through the cabinet wall are sealed by rubber
grommets with caulking on the exterior of the casing. Coils shipped with dry nitrogen holding charge
to prevent moisture intrusion and verify leak free arrival.

Indirect Fired Gas Heaters (In-shot Burners)


• Indirect fired heaters will have 80% minimum thermal efficiency and incorporate listed Gas-fired
components. The duct furnace models are listed by Intertek Testing Services (ITS/ETL) for operation
on natural or propane gas to the current edition of ANSI Z83.8 Standard for Gas-Fired Duct Furnaces.
Duct furnaces are for installation on the positive pressure side of the circulating air blower only.
• The duct furnace module employs an aluminized steel cabinet with 1-inch thick thermal insulation for
exterior cabinets, stainless steel tubular heat exchanger assembly, and a combustion blower to
provide positive venting of flue gas.
• Air pressure switches to prove air supply for combustion before operation of the gas valve. Patented
in-shot gas burners with integral carryovers and direct spark ignition of the gas burners with remote
flame sensor to prove carryover across all burners.
• Duct furnace modules are listed for application downstream of refrigeration and cooling systems and
provides means for removal of condensate that occurs in the tubes during cooling operation. Heat
exchanger tubes (integral formed dimpled restrictors; formed turbulators) provides for an
unobstructed drainage path and a positive pitch to promote condensate drainage. Drainage is
configured so that burners and burner surfaces are not exposed to condensate.

Dampers
• Standard dampers are opposed blade actuated spring return galvanized frames.
• Low leakage up to 5-inch differential pressure.
• Velocity up to 3000 fpm.
• -40°F to 250°F operating range.
• Stainless jam seals.
• TPE blade seals.

PKG-PRC025A-EN 15
Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient
indoor environments for commercial and residential applications. For more information, please visit trane.com
or tranetechnologies.com.
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We
are committed to using environmentally conscious print practices.

PKG-PRC025A-EN 15 Aug 2022


(NEW) ©2022 Trane

You might also like