Envicool XRow Cooling Solution

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Envicool · Data Center

and Equipment Thermal Expert

Data Center Cooling Energy Storage/Electricity Cooling


CyberMate V series inverter CRAC MC series split air conditioner

XRow series row-based cooling unit MC series door mounted integrated air
conditioner
XRack series micro-modularized
MC series wall mounted integrated air
solution
conditioner
Cabicool series rack cooling solution MC series floor standing integrated air
XSpace series modularized solution conditioner
HumidMate series data center MC series corner standing integrated air
conditioner
constant
MX series heat exchanger
humidity solution
XFlex series IEC solution EMW series air cooled chiller

iFreecooling series economization


system
XStorm series fan wall solution

Telecom Cabinet Cooling Industrial Cooling


DC series air conditioner EIA series air conditioner
EC series air conditioner EIB series air conditioner
HC series combo air EIX series air/water heat exchanger
conditioner
EIW series water cooler
EF series inverter air
conditioner
EX series heat exchanger

Fuji Bridex Pte Ltd

[email protected]
+65 6756 0833

www.bridex.fujielectric.com

Envicool reserves updating right without notice


Save paper for the protection of forest resources
About Envicool
Shenzhen Envicool Technology Co., Ltd. (stock code: 002837) is a hi-tech enterprise which focuses on
Data Center and equipment climate control. The team masters the world class cooling technology,
precise control technology, mechanical design technology and has obtained series patents around
temperature control. After years of accumulation, it has formed a climate control & energy saving system
for Data Center and Access stations.

The solutions and products are widely used in China and overseas market, including Data Center
Temperature Control and Energy-saving Solutions, S&M Data Center Temperature Control Solutions, Micro-
module Server Rack Solutions, Containerized & Modularized Data Center Solutions, Telecom Site Cooling
Solutions, Energy Storage Cooling Solutions, customized solutions for more applications, etc.

Envicool has obtained ISO9001, ISO14001 and ISO45001. The products are CCC, CE, UL, TUV and China
Energy- saving certified. Envicool adopts the Integrated Product Development (IPD) process to develop
products and technologies, and utilizes the JIT and TQC supply chain management modes to meet the
customers' requirement efficiently.

As a member of CCSA and CRA, Envicool takes an active part in the revision of relevant industry standards.

Certifications

ISO14001 ISO9001 ISO45001 CE CCC UL China Energy-saving Certification

National Hi-tech Shenzhen Hi-tech Patents Member of CCSA Outstanding Operation & Data Center Awards
Certification Certification Maintenance Team
Award

01
Company Profile

02
Efficient Cooling Solution for
XRow Row-based Cooling Unit

Modularized Data Center

How to Achieve High Energy Efficiency?

Section

■ Placed closely to the heat source, the return air temperature and evaporating pressure are increased, thus
cooling efficiency can be improved
■ Equipped with EC fan, short air supply distance, fan power consumption can be reduced by 20%~30%

■ Equipped with DC inverter compressor, 10%~100% cooling capacity stepless adjustment, efficiency under
partial load can be highly improved, suitable for data center load characteristics

■ Advanced EVO controller can control the airflow & cooling capacity output as required, realizing the best
cooling effect & lowest power consumption

03
XRow Series Configuration Nomenclature
No. Function Code Description

1 Series Name XRow series row-based cooling unit


XR
Air cooled
2 Series Code 6
Chilled water
9

0
3 Cooling Capacity Eg.: 40kW cooling capacity
4

A Air cooled

C Chilled water
4 System Type
W Water cooled

R CRU

H1 Installed between racks, rear air inlet, front air outlet


Structure Type and
5 Installed between the rack or integrated with racks design, with rear
Air Discharge
L4
air inlet, front air outlet ∠90 ° on both sides
B Cooling

H Cooling, reheating
6 Function
C Cooling, humidifying

P Cooling, reheating, humidifying

Optional Refrigerant / Without refrigerant pump


7
Pump Double circulation: integrated with refrigerant pump
O

XRow Series Indoor Conversion (Distribution) Unit


No. Function Code Description

CRU CRU abbr: refrigerant and chilled water conversion distribution unit
1 Series Name
CDU CDU abbr: chiled water distribution unit

2 Cooling Capacity 150 Cooling capacity: eg. 150 means 150kW

Applications

04
XRow Row-based Cooling Unit

Modularized DC
High Efficient Cooling
Flexible Configuration

Optional centralized condenser, saving space up to 60%


Optional refrigerant pump free cooling module, making
full use of low temperature natural cooling to save energy

Optional ∠90° supply air on both sides


Optional cooling capacity range: 5-60kW
Optional dual power input

XRow Series DX Units Features


Low Opex During Full Life Cycle
■ DC inverter compressor with 10%~100% cooling capacity
stepless adjustment, high efficiency under partial load
■ Indoor high efficient EC fan, supply air close to server
rack, saving energy by 20%~30%
■ Outdoor fan with stepless speed regulation, control
airflow volume as required
■ Compact design, saving space

■ High return air temperature design, energy efficiency


increased by 20%~30%

High Reliability
■ DC inverter, starting current less than rated current ,
reducing impact on power grid
■ Excellent performance with stable dehumidification
under 10% load
■ Expert self-diagnosis and fault warning function

■ N+1 redundant configuration of fans

Flexible Cooling
■ Precise control of temperature and humidity

■ The cooling capacity and airflow output automatically


adjust with load change
■ Intelligent team work function can help unbalanced load

area to realize coordination

05
EVO Intelligent Control System
EVO Display System
■ 7-inch, 800×480 dot matrix true color touch

■ screen Temperature and humidity curves

■ Graphical display of components running status

■ Alarm information display, easy for operation

and maintenance

■ Multi-level password protection, and hierarchical


authorization management

RS485, SNMP, TCP/IP EVO Team Work System


■ Team work 32 units, connecting network easily
CAN CAN CAN ■ Optional zone temperature control

■ Shared temperature and humidity setting

■ Team work mode: demand management, trend


management, rotation and breakdown shift
automatically, realizing adaptive energy saving

EVO Control System


■ N+1 redundant configuration of fan, control
airflow volume as required
■ Compatible with aisle differential pressure control

■ Optional multiple high-precision supply & return


air temperature and humidity sensors

■ Optional connection of multiple temperature and


humidity sensors, multi-point detection

EVO Intelligent Monitoring System


■ Standard RS485 interface, support modbus
protocol
■ Optional ethernet interface, support TCP/IP,
SNMP protocol
■ Optional cloud remote monitoring module,
read unit info remotely through web pages,
WeChat official account and APP
■ Support upgrading air conditioner software
and writing parameter remotely

06
XRow Row-based Cooling Unit

XRow Data Sheet of DX Units ( Air cooled/Water cooled)


Indoor Unit Model XR6012A XR6020A XR6040A XR6050A

Power Supply 380V 3Ph 50Hz 380V 3Ph 50Hz 380V 3Ph 50Hz 380V 3Ph 50Hz
35°C 37°C 35°C 37°C 35°C 37°C 35°C 37°C
Return Air Condition 26%RH 24% RH 26%RH 24%RH 26%RH 24%RH 26%RH 24%RH

Performance Technical Data

Total Cooling Capacity - kW 11.5 12.2 22.2 24.2 37.7 39.5 45.5 47.8

Sensible Cooling Capacity - kW 11.5 12.2 22.2 24.2 37.7 39.5 45.5 47.8

Sensible Heat Ratio - % 100 100 100 100 100 100 100 100
Max. Power Consumption of Unit
8.0 8.0 12.0 12.0 21.7 21.7 27.1 27.1
- kW
Full Load Amps (FLA) - A 16.5 16.5 23.4 23.4 41.6 41.6 58.5 58.5

Quantity of Compressor 1 1 1 1 1 1 1
1
Rated Power Consumption of 10.6 11.4 12.1
2.7 2.9 5.45 5.95 10.0
Compressor - kW
Indoor EC Fan Technical Data

Airflow - CMH 2500 4800 4800


2500 7800 7800 10000 10000
Quantity of EC Fan 6 6 6
6 4 4 10 10
Rated Power Consumption of 0.35 0.75 0.75
0.35 1.2 1.2 2.0 2.0
EC Fan - kW
Heating

Heating Capacity - kW 3 3 3 3 6 6 6 6

Humidification

Humidification Capacity - kg/h 3 3 3 3 3 3 3 3

Connection Size

Gas - mm 16 16 19 22

Liquid - mm 9.52 12.7 16 19

Drain Pipe - ID, mm 25 19 19 19

Physical Data

Width - mm 300 300 600 600

Depth - mm 1200 1200 1200 1200

Height - mm 2000 2000 2000 2000

Weight - kg 170 235 325 350

Breakers

Breaker- A 32 40 63 80

Remark: condensing temperature at 45℃

07
XRow Air-cooled Condenser
■ Stepless speed regulation fan
■ Owl fan with low noise
■ Optional iFreecooling integrated refrigerant pump free
cooling solution
■ Fans and motors with easy maintenance, adapt to various
climate conditions

XRow Air-cooled Condenser Data Sheet


Outdoor Unit Model XRC16 CS38 CS54 CS66

Full Load Amps (FLA) - A 10.5 1.7 1.7 3.4

Quantity of Fan 2 1 1 2

Operating Temperature Range (Standard) -20 ~45°C -20 ~45°C -20 ~45°C -20 ~45°C
Operating Temperature Range (with Low Temperature
Startup Kits)
-40 ~45°C -40 ~45°C -40 ~45°C -40 ~45°C
Physical Data
Width - mm 1280 1610 1910 1910
Depth - mm 360 653 653 653
Height - mm 1260 982 1270 1270
Weight - mm 125 130 150 160
Breakers & Cables
Breaker - A 20 10 10 20
Outdoor Unit
Power Cables - mm² 4 1.5 1.5 1.5
Remark:
• XRC16 supports horizontal installation only
• CS series outdoor units support horizontal and vertical installation

Centralized Air Cooled Condenser


■ V-type high efficient coil design
■ Stepless speed regulation fan
■ Modular design
■ Optional iFreecooling integrated refrigerant pump free
cooling solution
■ High chimney fan with low noise

Data Sheet of Air Cooled Centralized Condenser


Model
Quantity of
Fan
L (mm) W (mm) H (mm) Weight (kg) Liquid Line - Hot Gas Line -

OD mm) OD mm) (
CS38U 1 1020 1020 1840 120 16 22
CS54U 1 1020 1020 1840 140 16 22
CS66U 1 1080 1080 2000 155 19 28

08
XRow Row-based Cooling Unit
XRow + iFreecooling Data Sheet
Indoor Unit Model XR6020A XR6040A XR6050A

Power Supply 380V 3Ph 50Hz 380V 3Ph 50Hz 380V 3Ph 50Hz
Return Air Condition 37℃ DB/24%RH 37℃ DB/24%RH 37℃ DB/24%RH
DX Unit Performance
DX Cooling Capacity - kW 24.2 39.5 47.8
DX Sensible Cooling Capacity - 24.2 39.5 47.8
kW Sensible Heat Ratio - % 100 100 100
Indoor Fan Technical Data
Airflow - CMH 4800 7800 10000
Quantity of Fan 6 4 10
Heating
Heating Capacity - kW 3 6 6
Humidification
Humidification Capacity - kg/h 3 3 3
Connection Size
Liquid - mm 12.7 16 19
Gas - mm 16 19 22
Humidifier Inlet Pipe G1/2” G1/2” G1/2”
Condensate Pump Drain Pipe - ID, 10 10 10
mm Drain Pipe - ID, mm 19 19 19
Dimensions
Width - mm 300 600 600
Depth - mm 1200 1200 1200
Height - mm 2000 2000 2000
Breakers & Cables

Breaker - A 32 50 63
Cooling
Cables - mm² 6 10 16

Breaker - A 40 63 80
Cooling + Humidifying
Cables - mm² 6 10 16

Cooling + Humidifying Breaker - A 40 63 80


+ Reheating Cables - mm² 6 10 16

Remark: condensing temperature at 45℃

Data Sheet of Integrated Refrigerant Pump Centralized Condenser


Model Quantity of Fan L (mm) W (mm) H (mm) Liquid Line -

OD mm)
Hot Gas Line -
OD mm) (
CS38P 1 1020 1020 1840 16 22
CS54P 1 1020 1020 1840 16 22
CS66P 1 1080 1080 2000 19 28

Remark: the unit size is the footprint size, and the protruding part of the electric control box along the length direction is not included

10
XRow Row-based Cooling Unit

XRow Data Sheet of CW Units


Indoor Unit Model XR9020C XR9060C

Power Supply 380V 3Ph 50Hz 380V 3Ph 50Hz

Inlet Water Temperature -℃ 7 10 12 7 10 12

Outlet Water Temperature -℃ 12 15 18 12 15 18

Return Air Condition -℃ 35 37 35 37 35 37 35 37 35 37 35 37

Performance Technical Data

Total Cooling Capacity - kW 29.4 33.6 23.9 27.5 20.4 22.7 60.5 70.5 48.9 56.2 41.8 46.7

Sensible Cooling Capacity - kW 26.2 29.3 23.4 25.3 20.4 22.6 55.2 61.4 48.6 53.3 41.8 46.7

Sensible Heat Ratio - % 89.1 87.0 97.9 92.0 100 99.6 91.2 87.1 99.4 94.8 100 100

Rated Power Consumption of EC Fan - 0.75 0.75 0.75 0.75 0.75 0.75 3.50 3.50 3.50 3.50 3.50 3.50

kW Max. Power Consumption - kW 6.75 6.75 6.75 6.75 6.75 6.75 8.75 8.75 8.75 8.75 8.75 8.75

Full Load Amps (FLA) - A 14.7 14.7 14.7 14.7 14.7 14.7 16.97 16.97 16.97 16.97 16.97 16.97

Water Flowrate - m³/h 5.20 5.90 4.20 4.80 3.00 3.40 11.00 12.70 9.00 10.20 6.50 7.20

Water Side Pressure Drop - kPa 106.8 121.6 76.2 87.5 40.3 48.6 106.1 124.5 71.7 87.3 38.4 46.7

Main Fan Technical Data

Airflow - CMH 4800 11000

Quantity of Fan 6 3

Heating

Heating Capacity - kW 3 6

Humidification

Humidification Capacity - kg/h 3 3

Connection Size

Inlet Water Pipe 28 35

Outlet Water Pipe 28 35

Drain Pipe - ID, mm 19 19

Physical Data

Width - mm 300 600

Depth - mm 1200 1200

Height - 2000 2000

mm Weight 170 250

- kg
Breakers

Breaker - A 20 32

11
CDU Chilled Water Distribution Unit
with XRow Series Chilled Water Unit

Features

■ Standardized, easy to operate & maintain, standard rack


design, neat and tidy
■ Flexible installation location, either be close or far away from
the rack
■ Equipped with water leakage detector rope, high reliability
■ Each inlet & outlet water pipe has valve separately, to isolate
the chilled water unit, and make maintenance easy

■ Each inlet & outlet water pipe has insulation to prevent


condensation

Product Introduction

■ CDU chilled water distribution unit, to be flexibly used with XRow series chilled water unit
■ Achieve standardized connection between the chiller and the chilled water unit, and distribute chilled water evenly to each unit
■ Each water supply and return branch pipeline is equipped with a separate valve, independently control the cold water supply at
each end. The number of supply and return water branch pipelines can be designed according to actual needs

CDU Data Sheet


CDU Model CDU120 CDU180 CDU240

Performance Specification

Cooling Capacity - kW 120 180 240


Connection Size

Main Inlet Pipe - mm 76 89 89


MainOutletPipe-mm 76 89 89
Available Quantity of Chilled Water Unit 4 6 8
Chilled Water Unit Inlet Pipe - mm 35 35 35
Chilled Water Unit Outlet Pipe - mm 35 35 35
Physical Data

Width - mm 600 600 600

Depth - mm 1200 1200 1200


Height - mm 2000 2000 2000
Weight - kg 175 185 200

12
XRow Row-based Cooling Unit

XRow + CRU
Product Introduction
CRU to be used flexibly with XRow series cooling unit, using
integration of pump circulation and multi-connected cooling
unit. The outer chilled water circuit, which can be integrated
with a dry cooler to use natural cold sources or with chiller,
and the inner circulation is refrigerant flow circuit. Achieve no
water into data center

Applications
■ Data center of core computer room
■ Financial data center

Value / Features
High Reliability
■ No water into the data center
■ CRU refrigerant pump has 1+1 redundancy
■ Redundant backup of fans
■ Support dual power supply

High Energy Efficiency


■ Large-area micro-channel heat exchanger, with high heat
exchange efficiency
■ High efficient EC fan, energy saving by 20%~30%
■ 100% SHR design, no condensed water produced during operation

Intelligent Control
■ CRU is equipped with 7-inch touch screen
■ Advanced team work control function for multiple units
■ Graphical display of components operation and environmental
status
■ Standard RS485 interface, optional SNMP and TCP/IP interfaces

13
CRU Heat Pipe Air Conditioner System Diagram

CRU Data Sheet XRow Data Sheet


Model CRU100 CRU150 CRU240 CRU400 Indoor Unit Model XR030R XR060R

Cooling Capacity - kW 100 150 240 400 Power Supply 220V 1Ph 50Hz
Inlet Water Temperature - ℃ 7 7
Power Supply 380V 3Ph 50Hz Outlet Water Temperature - ℃ 12 12
Full Load Amps (FLA) - A 2.7 8 Return Air Condition - ℃ 37 37
2.7 8
Performance Technical Data
Refrigerant Inlet Pipe 42 54 54 67 Total Cooling Capacity - kW 28.0 44.5
Diameter - mm Sensible Cooling Capacity - kW 28.0 44.5
Refrigerant Outlet Pipe Sensible Heat Ratio - % 100 100
28 28 35 35
Diameter - mm Max Power Consumption - kW 0.8 1.50
Chilled Water Inlet Pipe Main Fan Technical Data
DN50 DN65 DN80 DN100 4800 9000
Diameter Airflow - CMH
Quantity of Fan 6 12
Chilled Water Outlet DN50 DN65 DN80 DN100 Connection Size
Pipe Diameter 16
Liquid - mm 16
1100 1100 1100 1700 Gas - mm
Width - mm 22 28
850 850 850 1000 Physical Data
Depth - mm
Width - mm 300 600
Height - mm 1950 1950 1950 2000 Depth - mm 1200 1200
Height - mm 2000 2000
Weight - kg 460 520 620 950
Weight - kg 190 270