0% found this document useful (0 votes)
200 views17 pages

MC-MJC e

This document discusses Mitsubishi's dual fuel auxiliary and composite boilers. It provides details on their production record and lineup of oil and dual fuel boilers ranging from 5 to 15 tons per hour of evaporation. Specifications and features are described for the MC-EF auxiliary boiler and MJC-F composite boiler. The document also outlines the boiler control system and dual fuel burner.

Uploaded by

motionblured65
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
200 views17 pages

MC-MJC e

This document discusses Mitsubishi's dual fuel auxiliary and composite boilers. It provides details on their production record and lineup of oil and dual fuel boilers ranging from 5 to 15 tons per hour of evaporation. Specifications and features are described for the MC-EF auxiliary boiler and MJC-F composite boiler. The document also outlines the boiler control system and dual fuel burner.

Uploaded by

motionblured65
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Mitsubishi Dual Firing Auxiliary Boiler

MC, MJC

August, 2022

BZA-S08055-R3

© 2022 MITSUBISHI HEAVY INDUSTRIES MARIE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved.
Contents

1. Dual Firing boiler production record


2. Lineup of Auxiliary and Composite Boiler
3. Specification of MC-EF Boiler
4. Feature of MC-EF Boiler
5. Specification of MJC-F Composite Boiler
6. Feature of MJC-F Composite Boiler
7. Boiler Control System
8. Dual Fuel Burner
9. Auxiliary Machinery

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 1
1. Dual Firing boiler production record

● More than 130 years history in the marine market

● Manufacturing Record;
Total about 6,035 sets (as of April 2022 including Main Boiler and Economizer)
459 sets of the boilers are for Dual firing Boiler.

Robust and Proven Design !!

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 2
2. Lineup of Auxiliary and Composite Boiler

■ Oil Firing

Evaporation (t/h) ~5 ~10 ~15 Image

MC-A
1~14 t/h
0.7MPa

Aux. MC-E
5~8 t/h
boiler 0.7MPa

MC-D
1~4.5 t/h
0.7MPa

Composite MJC
2~5 t/h
boiler 0.7MPa

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 3
2. Lineup of Auxiliary and Composite Boiler

■ Dual Firing

Evaporation (t/h) ~5 ~10 ~15 Image

MC-AF
5~11 t/h
0.7MPa
*1

Aux. MC-EF
5~8 t/h
boiler 0.7MPa
*1

MC-DF
1~4 t/h
0.7MPa

Composite MJC-F
2~5 t/h
boiler 0.7MPa

*1:Less than 5 t/h is available.

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 4
3. Specification of MC-EF Boiler
■ Specification
Type MC-50EF MC-60EF MC-70EF MC-80EF
Evaporation 5t/h 6t/h 7t/h 8t/h
Design Press. 0.9MPa
Working Press. 0.7MPa
Steam Temp. Saturated
Fuel Gas, HFO, MGO, LSHFO
FGC*1 322kg/h 387kg/h 451kg/h 516kg/h
*1 Fuel Gas Consumption CH4 : 100% (50MJ/kg LHV)

REFERENCE IMAGE CYLINDRICAL BOILER

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 5
4. Feature of MC-EF Boiler
■ Structure Platform

• Top-firing Burner DF Burner Safety valves


(Top firing)
• Water tube type Exhaust Gas

• Manhole on steam/water drum and Steam

furnace side
• Platform for access to top part of
Manhole
Boiler
Manhole

■ Feature
Soot blower
・Less soot deposit using plain tube
・Applied MHI own control system on
basis of conventional MAC-B boiler Plain Tube,
・Safety Control system considering In-line arrg’t

Furnace Explosion prevention

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 6
5. Specification of MJC-F Composite Boiler

■ Specification
MJC MJC MJC MJC
Type
-250F -280F -340F -360F
Evaporation
2t/h 3t/h 5t/h
at BNR. section

Design Press. 0.9MPa

Working Press. 0.7MPa

Steam Temp. Saturated

Fuel Gas, HFO, MGO, LSHFO

FGC*1 129kg/h 193kg/h 323kg/h

Exh. gas flow 30~ 60~ 70~


at Eco. section 100t/h 130t/h 180t/h
*1 Fuel Gas Consumption CH4 : 100% (50MJ/kg LHV)

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 7
6. Feature of MJC-F Composite Boiler

Exhaust Gas Outlet Exhaust Gas Outlet


■ Structure (Burner Side) (Economizer Side)

• Side-firing Burner
• Smoke tube type
• Manhole on water drum and exh. Manhole

gas side

Manhole

■ Feature
・Applied MHI own control system on
basis of conventional MAC-B boiler DF Burner

・Safety Control system considering (Side firing)

Furnace Explosion prevention Manhole

Exhaust Gas Inlet


(Economizer Side)

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 8
7. Boiler Control System

■ High Reliability & Safety Control System


MADIC : Mitsubishi Automatic Digital Illustrated Control System

⚫ ABC:Automatic Boiler Control


■ ACC:Automatic Combustion Control
・Master control
・Fuel flow control
・Air flow control
■ FWC:Feed Water Control

⚫ BMS : Burner Management System


・Burner Ignition / Extinguish
・Burner Purge Sequence
・Boiler Shut-down for safeguard
Emergency operation Boiler control panel

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 9
7. Boiler Control System
■ Countermeasure for Furnace Explosion
● Monitoring and Interlocking function
• Purging of furnace before igniting the burner (more than 6 times
air volume)
• Purging of furnace after extinguishing the burner
• Purging of residual fuel after extinguishing the burner
• Several interlock for burner ignition safety.
• Monitoring of flame condition

● Ignition Stability
• Ignition by a pilot burner flame
• Confirmation of pilot burner flame
during ignition

● Duplication of safety devices


• Flame scanners
• Fuel Shut-off Valves

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 10
7. Boiler Control System
■ GCU function
● Dual fuel burner is capable of oil or gas individual firing and
oil/gas dual firing.(FO mode/Gas mode/Dual mode)
● Boiler can be used as GCU
Purpose Fuel mode Remark

Initial gas filling up (N2⇒LNG) LNG mixed with N2 gas


Dual
Gas free (LNG⇒N2) (N2 contents : 0 to100%)

Fuel tank pressure adjustment Gas LNG (Pure methane)

FO Dual Gas
Fuel Mode Transition

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 11
7. Boiler Control System
■ Boiler data storage system
● Data collection can be available.

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 12
8. Dual Fuel Burner
■ Burner selection
● Burner maker is Volcano or Sunflame
● Burner is varied depending on the steam evaporation

Control
Evaporation Burner type (Maker)
system supplier
SDR (Sunflame)
1~4 t/h or Burner maker
Vignis (Volcano)

5~11 t/h SFFGII (Volcano) MHI-MME

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 13
8. Dual Fuel Burner
■ Burner specification

Maker Volcano Sunflame


Burner
SFFGII Vignis SDR
type
Fuel OIL Steam/Air atomizing type Rotary cup type
spray
method GAS External mixing External mixing
Turn down ratio 4.6~10:1 10:1 10:1

Appearance

© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 14
9. Auxiliary Machinery

Special Accessories for Dual Firing Boiler can be provided


■Extraction Air Fan Unit

■Gas Valve Unit with Enclosure


- Gas Detector
- Junction Box & Solenoid valve board
- Safety devices etc.

Outline of Ext. Air Fan

Outline of GVU
© 2022 MITSUBISHI HEAVY INDUSTRIES MARINE MACHINERY & EQUIPMENT CO., LTD. All Rights Reserved. 15