This document provides specifications for a microprocessor-based colorimeter. It has the following key features: - It can measure concentration levels at various wavelengths between 410-640nm. - It has features like auto-zero, LED light source, silicon photodiode detector, and data storage. - It provides measurement of transmittance, absorbance, and concentration values on its LED display. - It is compact, easy to use, and suitable for applications in fields like clinical, pharmaceutical, food, and more.

Uploaded by

Syed Fuzail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views2 pages

CL223

This document provides specifications for a microprocessor-based colorimeter. It has the following key features: - It can measure concentration levels at various wavelengths between 410-640nm. - It has features like auto-zero, LED light source, silicon photodiode detector, and data storage. - It provides measurement of transmittance, absorbance, and concentration values on its LED display. - It is compact, easy to use, and suitable for applications in fields like clinical, pharmaceutical, food, and more.

Uploaded by

Syed Fuzail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Microprocessor

CL 223
Based Colorimeter
PRODUCT SPECIFICATION SHEET

Table Top LED Display Test Tube

SALIENT FEATURES APPLICATIONS Clinical


Microcontroller based
Digital Colorimeter.
Pharmaceutical
Long Life LED Light source. In determination of
concentration
Auto Zero Facility. of constituents in
Long Life Photo Diode Detector. Food &
Beverages
Display of %T, Abs and
User friendly operation.
two Concentration Clinical
Water
scales C1 & C2. Last factors used for C1 and C2 will be Pharmaceutical
stored along with last wavelength and
the last scale even on power turn off. Agriculture
Food & Beverages

Auto Storage Facility for Concentration. Water Analysis. Chemical

Analytical and
Immune to ambient light variations.
Agricultural Mines &
Chemistry Geology
Compact, Rugged, Sturdy, Reliable and
Easy to Operate. Metallurgy
Metals

Only 1 ml of sample needed.


SPECIFICATIONS

PEAK WAVELENGTH PHOTOMETRIC RANGE LIGHT SOURCE


410, 470, 490, 520, 540, 580, % Transmission 0 to 250 LED
610 & 640 nm Absorbance -0.31 to 2.0 Abs
Repeatability ± 0.01 Abs DETECTOR
SAMPLE VOLUME
Readability %T 1
Silicon Photo Diode
Min. 1 ml Abs 0.01

SAMPLE HOLDER
CONCENTRATION RANGE SHUTTER
75 x 12 mm ± 0.5 mm Test tube
C1 000 TO 999 To prevent the Detector from
with 10 mm Path Length
continuous exposure to Light
C2 00.0 TO 99.9
ACCESSORIES SUPPLIED
DATA PRESENTATION
With Matched Test Tubes
Readout 5 digit 7 segment LED of 14mm height Instrument

POWER REQUIREMENT PHYSICAL DIMENSIONS


230 V ± 10% AC, 50 Hz, 1ϕ, 5 VA Max. Size (WxDxH) in mm 155 x 162 x 86
Weight (in kg) Approx. 1

B-90, A.P.I.E., Sanathnagar, Hyderabad 500 018, Telangana., India


An ISO 9001:2018 | 14001 | 27001 Certified Company
Tel +91 40 44451234 Fax +91 40 23771639 [email protected]

www.elico.co Celebrating 60 years of our Journey www.elico.co/60years

Ahmedabad Bengaluru Bhopal Bhubaneswar Chennai Cochin Delhi Guwahati


[email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]
+91 98241 75321 +91 99000 28741 +91 99930 96876 +91 99371 12105 +91 98402 65797 +91 81291 84400 +91 98710 06104 +91 91211 77451
© 2020 ELICO

Hyderabad Kolkata Lucknow Mumbai Patna Visakhapatnam


[email protected] [email protected] [email protected] [email protected] [email protected] [email protected]
+91 99896 25457 +91 91211 77452 +91 91980 01666 +91 77100 96111 +91 91211 77450 +91 99899 94532

You might also like