Manual de Instalare Modul de Extensie Paradox ZX1

The document provides instructions for programming and using the DGP2-ZX1 one-zone hardwire module with Digiplex and DigiplexNE security panels. It can be programmed through the panel's keypad or module broadcast feature to set options like tamper recognition and input speed timings. The module has one hardwired input for connecting up to two detection devices, which must be assigned to zones on the panel.

Uploaded by

citeste
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views2 pages

Manual de Instalare Modul de Extensie Paradox ZX1

The document provides instructions for programming and using the DGP2-ZX1 one-zone hardwire module with Digiplex and DigiplexNE security panels. It can be programmed through the panel's keypad or module broadcast feature to set options like tamper recognition and input speed timings. The module has one hardwired input for connecting up to two detection devices, which must be assigned to zones on the panel.

Uploaded by

citeste
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

WinLoad Security Management Software (refer to the WinLoad

Software Help File for more information).

Section [001] - Option [1]


Tamper Recognition
One-zone Hardwire Module V2.0
(DGP2-ZX1) The DGP2-ZX1 comes equipped with an on-board tamper switch.
When option [1] is enabled in section [001] and the tamper switch
is triggered, a Module Tamper report will be sent to the control
panel via the communication network.

INPUT SPEED TIMINGS


Instructions The input speed defines how quickly the input terminal on the
DGP2ZX1-EI02
DGP2-ZX1 responds to an open zone. The control panel will only
respond if the zone remains open for the duration of the Input
The One-zone Hardwire Module (DGP2-ZX1) is an interface Speed. All other zone definitions and options don’t come into effect
between the Digiplex (DGP-48) or DigiplexNE (DGP-NE96) control until the control panel has responded. This feature prevents any
panels and any hardwired detection devices. The DGP2-ZX1 momentary glitches from causing an alarm or unnecessary
connects to the Digiplex/DigiplexNE control panels’ communication reporting.
network providing you with one additional hardwired input. Input Speed = Base Time x Time Value.

INSTALLATION
Section [002]
The DGP2-ZX1 modules are connected to the control panel’s
communication network in a star and/or daisy chain configuration. Base Time
The communication network consists of four wires that provide This section determines the unit of time to be multiplied by the
power and two-way communication between the control panel and Time Value.
all modules connected to it. Connect the four terminals labeled red, 000 = 15 milliseconds
black, green, and yellow of each DGP2-ZX1 to the corresponding 001 = 1 second
terminals on the control panel as shown in Figure 1 on the back of 002 = 1 minute
this instruction. Please refer to the appropriate control panel’s
Installation & Reference Manual for maximum allowable installation
distance from the control panel. Section [003]
Time Value
ZONE CONNECTIONS
Enter a 3-digit decimal value between 001 and 255. This decimal
Each DGP2-ZX1 has one hardwired input terminal that will allow
value will be multiplied by the Base Time to determine the input
you to connect up to two (with ATZ enabled) non-bus detection
speed. For example, if section [002] = 001 and section [003] = 030,
devices to the Digiplex/DigiplexNE system. Each device connected
the Input Speed will be 30 seconds.
to the DGP2-ZX1’s input terminal must be assigned to a zone in
the control panel and the zone’s parameters must be defined. For
more information, please refer to the appropriate control panel SPECIFICATIONS
Installation & Reference Manual. The DGP2-ZX1 will communicate On-board tamper switch: Yes
the status of the zones to the control panel through the Voltage: 9-16 VDC
communication network. Connect the devices to the DGP2-ZX1 as Current consumption: 28mA maximum
shown in Figure 1 on the back of this sheet. Number of inputs: 1
Number of zones: 1 (2 with ATZ enabled) standard zone
The DGP2-ZX1 follows the ATZ and EOL definitions set
Input speed: 15ms - 255 minutes
in the Digiplex/DigiplexNE control panels.
Power-up indication: Green LED illuminated
Proper operation: Red LED flashes
PROGRAMMING METHOD Locate indication: Green LED flashes
From any keypad connected to the communication network: Communication Fault
STEP 1: Press and hold the [0] key Indication: Green and red LEDs flash alternately
STEP 2: Enter the [INSTALLER CODE] Locate deactivation: Press tamper switch
STEP 3: Enter section [953] (DGP-48) / [4003] (DGP-NE96) Humidity: 95% maximum
STEP 4: Enter the DGP2-ZX1’s 8-digit [SERIAL NUMBER]
STEP 5: Enter the 3-digit [SECTION] you want to program
STEP 6: Enter the required data

Please note that the serial number is located on the DGP2-ZX1’s


PC board. We recommend that you use the DGP2-ZX1’s
programming sheet found in the Digiplex/DigiplexNE Modules’
Programming Guide to keep track of what was programmed and
how. This module can also be programmed using the control
panel’s Module Broadcast Feature (refer to the appropriate control
panel Installation & Reference Manual) as well as through the
Figure 1: Connecting the DGP2-ZX1