Data Center Switch Data Center Switch: Key Features and Benefits

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DCS208 Data Center Switch

Data Center Switch


AS5812-54X

The Edgecore DCS208 switch meets the high-performance, availability, and network-scaling requirements of
enterprise and cloud data centers. The DCS208 provides full line-rate switching at Layer 2 or Layer 3 across 48 x
10GbE ports and 6 x 40GbE uplinks. The switch can be deployed either as a Top-of-Rack switch, or as part of a
10GbE or 40GbE distributed spine, forming a non-blocking folded-Clos data center fabric. The switch is rack
mountable in either a standard 19 inch rack, or with the Open Rack Switch Adapter in the 21 inch Open Rack.

The DCS208 hardware provides the high availability features required for data center operation, including;
redundant, hot-swappable AC or -48 VDC PSUs or 12 VDC power input; fan with 4+1 redundant fan modules; and
port-to-power or power-to-port airflow options. The DCS208 is an ideal Top-of-Rack switch for virtualized data
centers, with its support of VXLAN and NVGRE tunneling functions in hardware. This open network switch is loaded
with the Open Network Install Environment (ONIE), which supports the installation of compatible Network
Operating System soſtware, including the open source options, plus commercial NOS offerings.

Key Features and Benefits


■ Cost-effective, open network switch for data center fabric.
■ 48 x SFP+ switch ports, supporting 10GbE (DAC, 10GBASE-SR/LR) or 1GbE (1000BASE-T/SX/LX).
■ 6 x 40 QSFP switch ports, each supporting 40GbE (DAC, 40GBASE-SR4/LR4) or 4 x 10GbE (DAC or fiber breakout
cable).
■ Port Grouping to group 4 x 10G ports into one 40G port at the physical layer for maximum bandwidth utilization,
and for 300 m optical reach over MMF (Subject to NOS options).
■ VXLAN and NVGRE tunneling support in hardware for network virtualization.
■ Rack mountable in standard 19" racks. Mountable in 21" Open Rack with the Open Rack Switch Adapter.
■ Supports hot/cold aisle with port-to-power and power-to-port airflow SKUs.
■ All ports on front; PSUs, fan modules on rear.
■ Hot-swappable, load sharing, redundant AC or -48 VDC PSUs. 12 VDC power input option.
■ Hot swappable 4+1 redundant fan modules.
■ Management: Ethernet and console RJ-45 ports; USB storage port.
■ Hardware switch pre-loaded with Open Network Install Environment (ONIE) for automated loading of
compatible open source and commerical NOS offerings.
DCS208 Data Center Switch

Free Soſtware Included

Interfaces

1 2 3

5 6

7 8

9 10

Description
1. 48 x 10G SFP+ ports 6. RJ-45 console port

2. 6 x 40G QSFP+ uplink ports 7. PSU 2

3. RJ-45 management port 8. PSU 1

4. Port LED indicators 9. Grounding point

5. USB storage port 10. Hot-swappable 4+1 redundant fans


DCS208 Data Center Switch
Ports Soſtware
■ Switch Ports: ■ Switch is loaded with Open Network Install Environment (ONIE)
48 x SFP+ each supporting 10GbE or 1GbE soſtware installer
6 x QSFP each supporting 40GbE or 4 x 10GbE ■ Compatible with the following NOS options: open source
■ Management Ports on Front Panel: options, plus commercial NOS offerings.
1 x RJ-45 serial console
1 x RJ-45 100/1000BASE-T management Power
1 x USB Type A storage port ■ PSUs: 2 redundant, load-sharing, hot-swappable AC or -48 VDC
Input Voltage: 90 to 264 VAC at 50-60 Hz. -48 to -72 VDC.
Key Components ■ Input Current: Max 6 A@100/120 VAC, 3 A@ 200/240 VAC,
■ Switch Silicon: Broadcom BCM56864 Trident II+ 720 10 A@ -72 VDC
■ CPU Modules: ■ PSU Efficiency: Up to 93% for AC PSUs
Intel® Atom® C2538 quad-core 2.4GHz x86 processor ■ Power input option: 12 VDC
8 GB SO-DIMM DDR3 RAM with ECC ■ Max Power: 282 W, with pluggable optics
16 MB SPI
32GB mSATA Regulatory
■ EMI
Performance CE Mark (EN55032 Class A)
■ Switching Capacity: 1.44 Tbps full duplex FCC Part 15 Class A
■ Forwarding Rate: 1 Bpps ■ VCCI
■ Jumbo frames support up to 9K Bytes ■ Safety
■ Packet Buffer Size: 16 MB integrated packet buffer CB, EN 62368
■ Subject to NOS: UL
■ MAC Address: 32 K min./288 K max. ■ Environmental:
■ VLAN IDs: 4 K Temperature: IEC 68-2-14
■ Support 4 K ECMP group Drop: ISTA 2A
■ IPv4: 16 K min./112 K max. host entries; 16 K LPM entries with Vibration: IEC 68-2-36, IEC 68-2-6
TCAM-only mode Shock: IEC 68-2-29
■ IPv6: 8 K min./56 K max. host entries; IPv6/64=8K TCAM-only Acoustic Noise Level: Target at under 60 dB in 40°C
mode ■ RoHS-6 Compliant
■ Country of Origin: Taiwan (TAA Compliant)
Supported Optics and Cables
■ SFP+ Ports: Warranty
10GBASE-CR DAC: up to 5 m passive; up to 10 m active Please check www.edge-core.com for the warranty terms in your
10GBASE-SRL/SR: up to 100/300 m over OM3 MMF country.
10GBASE-LR: Up to 10km over SMF 10GBASE-T
1000BASE-SX, 1000BASE-LX, 100/1000BASE-T For More Information
■ QSFP Ports: To find out more about Edgecore Networks Corporation products
40GBASE-CR4 DAC; 0.5 m to 7 m; Passive and Active and solutions, visit www.edge-core.com.
40GBASE-CR4 DAC to 4 x SFP+
40GBASE-SR4: Up to 100 m over OM3 MMF, 150 m over OM4 MMF About Edgecore Networks Corporation
Edgecore Networks Corporation is in the business of providing
40GBASE-LR4: Up to 10 km over SMF
innovative network solutions. In the service provider network, in the
data center or in the cloud, Edgecore Networks Corporation delivers
Physical and Environmental
the soſtware and systems that transform the way the world
■ Dimensions (WxDxH): 43.84 x 47.3 x 4.34 cm (17.26 x 18.62 x 1.71 in) connects. Edgecore Networks Corporation serves customers and
■ Weight: 8.95 kg (19.73 lb), with two installed PSU modules partners worldwide. Additional information can be found at
■ Fans: hot-swappable 4+1 redundant fans www.edge-core.com.
■ Operating Temperature: 0°C to 40°C (32°F to 104°F)
■ Storage Temperature: -40°C to 70°C (-40°F to 158°F) Edgecore Networks Corporation is a subsidiary of Accton
■ Operating Humidity: 5% to 95% non-condensing Technology Corporation, the leading network ODM company. The
Edgecore data center switches are developed and manufactured by
LEDs Accton.
■ 10G SFP+ Port LEDs: Link Speed, Link Status, Activity
■ 40G QSFP Port LEDs: Link Status, Activity for 40G status To purchase Edgecore Networks solutions, please contact your
■ 40G QSFP Breakout LEDs: set of 24 LEDs, 4 per QSFP port, Edgecore Networks Corporation representatives at +886 3 563 8888
show Link, Status, Activity 10G links with 4 x 10G breakout (HQ) or +1 (949)-336-6801 or authorized resellers.
■ Ethernet Management Port LED: Link Status, Activity
■ Console Port LED: Link Status © Copyright 2021 Edgecore Networks Corporation. The information contained herein
is subject to change without notice. This document is for informational purposes only
■ System LEDs: PSU1, PSU2, Diagnostic, Fans, Locator and does not set forth any warranty, expressed or implied, concerning any
equipment, equipment feature, or service offered by Edgecore Networks Corporation.
Edgecore Networks Corporation shall not be liable for technical or editorial errors or
omissions contained herein.
DCS208 Data Center Switch

Ordering Information
Base Model: AS5812-54X; Intel® Atom® C2538 processor; 48-Port 10G SFP+ with 6x40G QSFP uplinks; ONIE
soſtware installer.
Model Number Part Number PSU Airflow Region (power cord)

5812-54X-O-AC-F-US FP1ZZ5654408A dual AC PSUs port-to-power airflow N. America

5812-54X-O-AC-B-US FP1ZZ5654409A dual AC PSUs power-to-port airflow N. America

5812-54X-O-AC-F-EU FP1ZZ5654208A dual AC PSUs port-to-power airflow Europe

5812-54X-O-AC-B-EU FP1ZZ5654209A dual AC PSUs power-to-port airflow Europe

5812-54X-O-AC-F-UK FP1ZZ5654308A dual AC PSUs port-to-power airflow UK

5812-54X-O-AC-B-UK FP1ZZ5654309A dual AC PSUs power-to-port airflow UK

5812-54X-O-AC-F-JP FP1ZZ5654508A dual AC PSUs port-to-power airflow Japan

5812-54X-O-AC-B-JP FP1ZZ5654509A dual AC PSUs power-to-port airflow Japan

5812-54X-O-48V-F FP1ZZ5654043A dual -48 VDC PSUs port-to-power airflow

5812-54X-O-48V-B FP1ZZ5654045A dual -48 VDC PSUs power-to-port airflow

5812-54X-O-12V-F FP1ZZ56540CAA one 12 VDC power input port-to-power airflow

5812-54X-O-12V-B FP1ZZ56540CCA one 12 VDC power input power-to-port airflow


400 W AC Power Supply FRU
CPR-4011-4M11 F0TZZ5652003A port-to-power airflow no power cord
(PSU-AC-400-F)
400 W AC Power Supply FRU
CPR-4011-4M21 F0TZZ5652002A power-to-port airflow no power cord
(PSU-AC-400-B)
400 W -48 VDC Power Supply FRU
UM400D01-01 F0TZZ5654004A port-to-power airflow no power cord
(PSU-48V-400-F)
400 W -48 VDC Power Supply FRU
UM400D01 F0TZZ5654003A power-to-port airflow no power cord
(PSU-48V-400-B)
FAN-1U-1x1D-F F0TZZ5654000A Fan Tray FRU port-to-power airflow

FAN-1U-1x1D-B F0TZZ5654001A Fan Tray FRU power-to-port airflow

Model Number Part Number Description

58XX-54X-SVC-RTF REWECECWA008Z AS5812-54X Annual Hardware Service, post warranty, Return-to-Factory

RKIT-L-6712 F0TZZ6632001A Rack mount kit


Open Rack Switch Adapter, for mounting standard 19 inch form factor 1U switches into 21
ORSA-1U F0TZZ5654002A
inch Open Rack

EC-DS-1221-R14

You might also like