Application Manual
9.555.012.4-05 EN/4.94
About this Documentation
Copyright: Copying of this document, and giving it to others and the use or
communication of the contents thereof without express authority are
forbidden. Offenders are liable to the payment of damages. All rights
are reserved in the event of the grant of a patent or the registration
of a utility model or design.
1.1. A safe way to power Production systems, transfer lines and machine tools often consist of
down separate working areas spatially separated working areas, e.g., processing units, transport,
in machinery or plant handling and storage systems (see Figure 3).
If the drive axes in adjacent working areas and in the danger zone are
centrally connected to the power mains by a supply unit (e.g., supply
modules TVM, KDV, TVD, KVR), then each direct-drive motor must
be individually secured against unintentional motions. The danger
zone is the area in which the individual is working.
The starting lockout built into every INDRAMAT drive module makes
it easy to safely power down the motor of each axis with a simple
switch. This switch disconnects the output stage from the control
electronics with the use of a relay in the hardware. The user gains the
following advantages:
The internal control circuits and the output stage control are
internally locked for additional safety. An external motor contactor
does not ensure an additional internal locking of the drive electron-
ics.
1.2. Operating individual axes Drives are frequently run individually during installation. In this case
during installation as well, personnel is often found within the danger zone. Generally,
the acknowledgement switch is used to switch on the mains contactor
to operate the axes. The mains contactor is then switched off again
if unwanted movement occurs, or at the end of an operation.
In addition, using this relay to switch the motors on and off reduces
wear and tear. In effect, it also increases reliability and safety.
2.1. Motor controller function The power for motor current and thus the torque are advanced via the
final output stage (driver) of the drive module. The extent of the
current in the three phases of the three-phase motor is transmitted by
the controller electronics to the final output stage in the form of a
switch-mode pulse-width modulated signal.
The greater the width of the pulse or the switch-mode ratio, the
greater the motor current. The three currents in the three phases of
the motor must additionally be adjusted, in terms of amount and
phase position, to the rotor position given at that point in time, for
sufficient torque to be produced.
2.2. Using the starting lock- The signal at terminals AS1-AS2 of INDRAMAT’s drive module
out signal to secure power activates an internal relay which has two forcibly-connected contacts
off (see Fig. 1). The relay has been quality controlled.
– The first contact of this relay separates the internal controller voltage
of the final output stage in the hardware.
– The control and controller electronics are simultaneously and addi-
tionally blocked. This achieves double redundancy.
– The second contact (acknowledgement contact) signals the activa-
tion of the first contact to the outside.
This means it is not possible, in the event of a fault and given all
conceivable possibilities, that a switch-mode motor current (alternat-
ing current) could be produced within the electrical facilities of the
machine which could make the motor move.
It is also not possible for a current to flow through the motor even when
a fault occurs in one of the six final output stages. The drive does not
move. This fault is immediately acknowledged
– as soon as personnel has moved out of the danger zone,
– when the machine or sector of the facility has been properly
reblocked.
Link circuit
Mains
Supply
module Drive module Drive module Drive module
Controller AS1 AS2 ASQ ASQ AS1 AS2 ASQ ASQ AS1 AS2 ASQ ASQ
2. How the Starting Lockout Works
11
3. Installation and Operating Guidelines
3. Installation and
Operating Guidelines
3.1.1. Using the master switch The master switch must be used to disconnect all of the machine’s
to disconnect the mains electrical equipment from the mains in the following instances:
– when cleaning the machine
– for maintenance and repairs
– prior to long breaks in operation
3.1.2. Using the mains In an emergency off/emergency stop situation the mains contactor
contactor to disconnect the must be disconnected directly so that all main current circuits are
mains switched to zero potential. Those main current circuits that serve
safety purposes must be disconnected first, but not until these
measures have been concluded.
An emergency off situation is defined as danger to either personnel
or machinery in the presence of several faults or problems.
3.1.3. Using the starting The starting lockout exclusively serves to secure the attached motors
lockout to secure against against unintentional starts caused by a fault. Activating it while the
unwanted starts motor is running does not automatically guarantee that the drives will
be safely shutdown.
During the planning stage and at that time when the machine
is commissioned it should be determined that the starting
lockout can only be activated when the motor is standing
still. This applies to those cases where a torque-free operation
of the drive can cause damage. It is therefore necessary with
hanging axes to tightly clamp the axis before activating the
mechanical brake.
It is not possible to use (only) the starting lock in the following cases:
– for the purpose of electrically separating the motor from the power
voltage of the drive module, e.g., when exchanging motors;
– for any other maintenance, repair or cleaning work on the machine.
BRI+ - BRI- (1) Input for controller voltage for 24 Volt ± 10%
motor blocking brake.
3.3. Sequence and cycle The function and reliability of the starting lockout in its interaction with
when using the starting lock- all other system components of the machine or facility are only as
out good and as safe as the extent to which the following guidelines were
taken into consideration during planning and were checked during
the commissioning of the machine.
1. Shutdown drives:
The drives which are to be shutdown must first be brought to rest
before the starting lockout can be activated.
4. Commissioning operation:
If one or several axes are to be operated during the commissioning
operation with protective devices cancelled, then this should only be
possible if qualified personnel enable this type of operation with a key
switch.
All drives must otherwise be disconnected from the mains via the
emergency off circuit, in this case automatically. The respective
commissioning guidelines must be followed.
Once the protective devices have been cancelled, then the automatic
emergency stop must be immediately activated if one of the following
faults occur. All the drives connected to the central supply module are
halted and hereby disconnected from the mains via the mains
contactor:
6. Access ready:
Once all the preceding steps have been performed and checked, then
all the drives in the disconnected working area have been secured
against unwanted movement.
It is now possible for personnel to enter this zone and access the
equipment.
E1
n(set-point)
E2
RF
0VM
AS1
AS2
ASQ
ASQ
Emergency off
circuit, mains
disconnect
Speed set-point
Set-point default drives halted
n(set-point) at
(e.g. from NC) n(set-point) = 0
input E1 - E2
Controller enable
signal RF off
Controller Drives halted and
enable signal at electronically locked
terminal RF
t
0.5 sec.
Starting
lockout input
signal at
terminal Starting lockout AS
AS1 - AS2 activated
t
max. 0.2 sec.
Doors open,
protective device cancelled
AS/Zeit
3.4. Test The following tests should be performed on each drive in sequence
after each initial commissioning and at set intervals during operation.
No personnel should be within the danger zone during these tests.
It it evident that the mains contactor drops off with a fault (=door
contact and acknowledgement contact ASQ-ASQ open), and the
drive package is disconnected from the mains.
The controller enable signal of the drive module and the set-point can
hereby be simultaneously set to zero. The running drives will then
brake and their energy will be fed into the d.c. voltage link circuit.
Enclosure and
limitations of the
danger zone
Door lock
Door lock
Access door
Mains
Mains
contactor K1
Bb 1
AS1
AS1
AS1
AS1
AS1
ASQ
ASQ
ASQ
ASQ
ASQ
ASQ
ASQ
ASQ
ASQ
ASQ
AS2
AS2
AS2
AS2
AS2
AS/Prinz
Figure 3: A sketch outlining the starting lockout applications using the example of
separated working areas.
AS/manuell
Drives locked Drives locked
in working area in working area
Door ASQ I II
contact for Bb1
working area I
ASQ
Off
3. Installation and Operating Guidelines
K3
On
Multichannel
auxiliary
relays with
K4 contact
monitoring
Mains
contactor K1
19
3. Installation and Operating Guidelines
Variant A:
Emergency off
Off
On
K
a
K
b
K
c
K K K
c b a
Emergency off
Off
K K K On
a c a
K K
b a K
b
K K
c K c
b
K K K
c b a
AS/K4/A+B
4. Controller types The following servo drive modules with starting lockout are available
in addition to standard controllers (without starting lockout).
and related plans
(2) The additional plug-in terminal is plugged into the unit upon
delivery and is, therefore, not a part of the connecting accessories
E...-TDM. In other words, both the standard unit and the unit
with starting lockout have the same connecting accessories.
Related plans
Plan Servo drive module with Figures
starting lockout
X8
RESET
S1
A1 +24V
±15V
Motoranschluß
BLC2
BLC3
A2 Tacho
Electrical connecting accessories POWER
and programming module RF
Bb
TS
A3
BS
AS
WARNING
L- 300 VDC INPUT
DISCHARGE TIME
Entladezeit > 1 Min.
POWER SUPPLY OUTPUT
VOLTAGE RATING, MUST
Busbars NOT EXCEED POWER
INPUT VOLTAGE DATA
Nur mit Versorgungseinheit
gleicher od. kleinerer POWER-
L+ Spannungsangabe betreiben
Bus terminal X1
ATTENTION!
NEVER REMOVE OR INSTALL THIS
PLUG WHILE VOLTAGE IS APPLIED.
BLACK CABLE ON THE BOTTOM!
Verbindung nie unter Spannung
AC SERVO CONTROLLER
lösen bzw. stecken.
Schwarze Leitung immer unten! TDM ...-100-300-W0
236226 K39/91
X1
SN240060-02029 A01
Programming module MOD with rating plate
Betriebsdaten-Programmierungsmodul
X2
Achtung: Motor- und Verstärkertypenangaben müssen mit der
Installation übereinstimmen, sonst Schädigungsgefahr.
Offset
adjust
X9
Plug-in terminals 1 2 3 4 ZERO ADJ
AS1
AS2
ASQ
ASQ
1 2 3 4 X5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
E1
E2
E3
E4
Bb
Bb
RF
0VM
+15V
0VM
-15V
Ired
MA
Tsense
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10
X6
+15V
0VM
-15V
Tacho
BLC1
BLC2
BLC3
0VM
1 2 3 4 5 6 7 8 9 10
FrontanTDM13
Plug-in terminals
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Servo drive module
Spannungs- und
isolationsgeprüft
BRO+
nach DIN VDE 0160
BRO-
BRI+
TMO
TMO
ASQ
ASQ
BRI-
AS2
AS1
TMI
TMI
frei X8
DO NOT OPERATE
WITHOUT POWER
RESET
A1 S1
Motoranschluß
+24V
HIGH VOLTAGE
±15V
BLC1
Electrical connecting accessories A2
BLC2
MOTOR POWER
and programming module BLC3
Bus terminal X1
L+
ATTENTION!
NEVER REMOVE OR INSTALL THIS
PLUG WHILE VOLTAGE IS APPLIED.
BLACK CABLE ON THE BOTTOM!
Verbindung nie unter Spannung
lösen bzw. stecken.
Schwarze Leitung immer unten! AC SERVO CONTROLLER
TDM 3.3-020-300-W0
236226 K39/91
SN240060-02029 A01
X1
Programming module MOD with rating plate
POSITION FOR OPERATING PARAMETER
MOD 13/1X012-002
PROGRAMMING MODULE, PLUG IN
-15VM
BLC 1
BLC 2
BLC 3
Tacho
0VM
0VM
Plug-in terminals 1 2 3 4 5 6 7 8 9
Feedback
X43
+15VM
-15VM
+24VL
1 2 3 4 5 6 7 8 9
0VM
0VL
RF
TÜ
Bb
Bb
1 2 3 4 5 6 7 8 9 10
Inputs and outputs
1 2 3 4 5 6 7 8 9 10
X42
+15VM
Tsense
0VM
Ired
MA
FB
Iist
E1
E2
E3
E4
1 2 3 4 5 6 7 8 9 10 11 12 13
1 2 3 4 5 6 7 8 9 10 11 12 13
Inputs and outputs
FrontanTDM33
Plug-in terminals
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Servo drive module
Spannungs- und
isolationsgeprüft
BRO+
BRO-
nach DIN VDE 0160
BRI+
TMO
TMO
ASQ
ASQ
BRI-
AS2
AS1
TMI
TMI
frei
X8
DO NOT OPERATE
WITHOUT POWER
RESET
A1 S1
Motoranschluß
+24V
HIGH VOLTAGE
±15V
BLC1
Electrical connection accessories A2
BLC2
MOTOR POWER
and programming module BLC3
Bus terminal X1
L+
ATTENTION!
NEVER REMOVE OR INSTALL THIS
PLUG WHILE VOLTAGE IS APPLIED.
BLACK CABLE ON THE BOTTOM!
Verbindung nie unter Spannung
lösen bzw. stecken.
Schwarze Leitung immer unten!
AC SERVO CONTROLLER
TDM 4.3-020-300-W0
236226 K39/91
MOD 17/1X001-193
CORRECT MODULE, BEFORE START UP
Platz für Betriebsdaten-Programmierungs-
HS 1
HS 2
HS 3
0VM
T0
T1
T2
T3
Plug-in terminals 1 2 3 4 5 6 7 8 9 10
Feedback
X49
+15VM
-15VM
24VL
1 2 3 4 5 6 7 8 9 10
0VM
0VL
RF
TÜ
Bb
Bb
1 2 3 4 5 6 7 8 9
Inputs and outputs
X50
1 2 3 4 5 6 7 8 9
+15VM
Tsense
0VM
Ired
MA
FB
Iist
E1
E2
E3
E4
1 2 3 4 5 6 7 8 9 10 11 12 13
1 2 3 4 5 6 7 8 9 10 11 12 13 Inputs and outputs
FrontanTDM43
Plug-in terminals
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Servo drive module
Spannungs- und
isolationsgeprüft
BRO+
nach DIN VDE 0160
BRO-
BRI+
TMO
TMO
ASQ
ASQ
BRI-
AS2
AS1
TMI
TMI
frei X8
DO NOT OPERATE
WITHOUT POWER
RESET
A1 S1
Motoranschluß
+24V
HIGH VOLTAGE
±15V
BLC1
Electrical connection accessories A2
BLC2
MOTOR POWER
and programming module BLC3
Bus terminal X1
L+
ATTENTION!
NEVER REMOVE OR INSTALL THIS
PLUG WHILE VOLTAGE IS APPLIED.
BLACK CABLE ON THE BOTTOM!
Verbindung nie unter Spannung
lösen bzw. stecken.
Schwarze Leitung immer unten! AC SERVO CONTROLLER
TDM 6.1-020-300-W0
236226 K39/91
SN240060-02029 A01
X1
Programming module MOD with rating plate
POSITION FOR OPERATING PARAMETER
MOD 19/1X012-002
PROGRAMMING MODULE, PLUG IN
-15VM
BLC 1
BLC 2
BLC 3
Tacho
0VM
0VM
Plug-in terminals 1 2 3 4 5 6 7 8 9
Feedback
X43
+15VM
-15VM
+24VL
1 2 3 4 5 6 7 8 9
0VM
0VL
RF
TÜ
Bb
Bb
1 2 3 4 5 6 7 8 9 10
Inputs and outputs
1 2 3 4 5 6 7 8 9 10
X42
+15VM
Tsense
0VM
Ired
MA
FB
Iist
E1
E2
E3
E4
1 2 3 4 5 6 7 8 9 10 11 12 13
1 2 3 4 5 6 7 8 9 10 11 12 13
Inputs and outputs
FrontanTDM6
Plug-in terminals
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Servo drive module
Spannungs- und
isolationsgeprüft
BRO+
BRO-
BRI+ nach DIN VDE 0160
TMO
TMO
ASQ
ASQ
BRI-
AS2
AS1
TMI
TMI
frei
X8
DO NOT OPERATE
WITHOUT POWER
RESET
A1 S1
Motoranschluß
+24V
HIGH VOLTAGE
±15V
BLC1
Electrical connecting accessories A2
BLC2
MOTOR POWER
and programming module BLC3
Bus terminal X1
L+
ATTENTION!
NEVER REMOVE OR INSTALL THIS
PLUG WHILE VOLTAGE IS APPLIED.
BLACK CABLE ON THE BOTTOM!
Verbindung nie unter Spannung
lösen bzw. stecken.
Schwarze Leitung immer unten!
AC SERVO CONTROLLER
TDM 7.1-020-300-W0
236226 K39/91
MOD 21/1X005-123
CORRECT MODULE, BEFORE START UP
Platz für Betriebsdaten-Programmierungs-
HS 1
HS 2
HS 3
0VM
T0
T1
T2
T3
Plug-in terminals 1 2 3 4 5 6 7 8 9 10
Feedback
X49
+15VM
-15VM
24VL
1 2 3 4 5 6 7 8 9 10
0VM
0VL
RF
TÜ
Bb
Bb
1 2 3 4 5 6 7 8 9
Inputs and outputs
X50
1 2 3 4 5 6 7 8 9
+15VM
Tsense
0VM
Ired
MA
FB
Iist
E1
E2
E3
E4
1 2 3 4 5 6 7 8 9 10 11 12 13
1 2 3 4 5 6 7 8 9 10 11 12 13 Inputs and outputs
FrontanTDM7
12
Safety guard
373
355
X2
X6
min. 80 mm for 7
9
Maßblatt TDM13
Tightening torque M (Nm) for terminal bolt: M6 = 5 Nm
A
Tightening torque M A(Nm) for terminal bolt: M5 = 3 Nm
Tightening torque M A(Nm) for terminal bolt: M5 = 1,5 Nm
27
28
Fan baffle only required View without safety guard
if the unit 12 325
- is mounted on min. 80 mm for
the left side of the 7 Outlet for cooling air cooling air outlet
drive package, or, 5
- is mounted at a
distance greater than
100 mm from an adjacent unit
on the left side. M5
(Fan baffle with screws S1
A1
INDRAMAT mat. No.: 224 869
must be ordered separately) A2
RESET
A3
Motor connection
LED Display Safety guard
( 3 x M6 ) L-
373 +1
Heatsink
355
X8
390
Controller
X1
voltage supply
Programming
module
Feedback
max. 1.5 mm ZERO-ADJ Zero adj.
Ready to operate and speed control
controller voltages
max. 1.5 mm
Set point
max. 1.5 mm Access for cooling air min. 80 mm for
9
7
326 cooling air outlet
4. Controller types and related plans
70
Function input,
Tightening torque M A (Nm) for terminal bolt X8: M6 = 5 Nm
signals
Tightening torque M A (Nm) for terminal bolt X8: M5 = 3 Nm
15 poles, max. 1.5 mm 2
Maßblatt/TDM33/43/6/7
128
Safety guard
Figure 12: Dimension sheets for TDM 3.3, TDM 4.3, TDM 6.1 and TDM 7.1
48
4. Controller types and related plans
min. 80
390
TDM1/Einbau
373
105
TDM
105
TDM
60
7
TDM
TDM
TVM
min. 80
min. 2
housing or cabinet
Completely closed
325
min. 400
min. 80
TDM3/4/6/7Einbau
390
373
TDM
70
74±0,5
TDM
TDM
TDM
TDM
7
92±0,5
TVM
105
60
min. 80
min. 2
housing or cabinet
Completely closed
325
min. 400
Figure 14: Mounting dimensions for TDM 3.3, TDM 4.3, TDM 6.1 and TDM 7.1
Standard type:
24V-Connection
TDM …
Standard module
cooling unit LE 5-024 (24 volt fan)
80
min. 200
61
65,5
290,5
Obsolete type:
TDM …
F7
min. 200
X74
290,5
61
65,5
LE5
Figure 15: Fan dimensions for TDM 3.3, TDM 4.3, TDM 6.1 and TDM 7.1
modules
Programming
MOD 1 / MOD 2
ext. use
Tacho signal for
use
Shield
Current set-point
for external
Ready to operate
Summing input
Summing input
Differential input
X8 X8
X5
9
8
7
6
5
4
3
2
1
11
15
14
13
12
10
L- L- Power
Busbars
Bb
Bb
E4
E3
E2
E1
RF
DC 300 volts
MA
Ired
0VM
0VM
L+ L+ (busbars)
-15VM
Tsense
+15VM
Supply for
1 UD 1
2 BB additional
Bus connection 3 +15VM Servoantriebsmodul TDM 1.3
4,5,6,7 0VM Signal drive
cable processing
8,9 -15VM (12 pole bus modules
10 0VL cable)
black 11 +24VL using
12 12 electrical
X1 X1
connecting
accessories
X13 X14
Shield
avail.
Reference potential
Tacho voltage
Rotor position acknowledgement
Rotor position acknowledgement
Rotor position acknowledgement
Supply voltage
Unit fan
Special AC 220 volts
3-pole cable (1) AC 220V AC 220V (3 pole special
Motor power
ASQ cable)
ASQ
AS2
AS1
internal F5 connection
0VM
Tacho
BLC 1
BLC 2
BLC 3
+15VM
0VM
-15VM
X9
4
3
2
1
4
9
5
6
7
8
1
2
3
X8
4. Controller types and related plans
10
A1 A2 A3
0VL
+24VL
AC 220V
5
2
3
4
7
8
9
11
10
12
F G H E A B C D
(1) Note on the controller fan:
+24VL Controller
ϑ>
3
Acknowledgement
Anschlpl/TDM13
MAC Servo Motor
4. Controller types and related plans
accessories
connecting
Supply for
additional
using the
electrical
modules
AC 220 volt
drive
additional
supply of
modules
drive
ext. 24 volt unit fan
M
(12 pole bus
Obsolete type
DC 300 volts
+24VL
processing
X73
ext. unit fan
(1)
(busbars)
0VL
Signal
cable)
Power
M
X43/4
X43/5
AC 220 volts
X74 F7
module X14
from supply
or drive
AC 115/220 volt
(1) Connection for
L+
X8
L-
X1
unit fan:
optional
12
1
Programming
module
220V
MOD 13 / MOD 14
AC
Motor
fan
M
Servoantriebsmodul TDM 3.3
X41
3
1
Motor feedback
Bb 2 11
Controller enable signal 3 Supply voltage 0VM
RF 1 10
4 +15VM
+24VL 8 9
5 Rotor position acknowledgement BLC 3
Controller voltage 0VL 7 8
6 Rotor position acknowledgement BLC 2
6 7
for external 7 Rotor position acknowledgement BLC 1
+15VM 5 4
use 8 Tacho voltage Tacho
0VM 9 2
9 Reference potential 0VM
-15VM 4 5
10 Shield
Temperature monitoring TÜ 6
X8
X43
Motor power
D
connection
A1 A2 A3
X42
M
B
1
3
E1
Differential input 2
A
E2
Blocking Thermostat
3
contact
Shield
4 TMI 14
E
E3
Summing input
5 ϑ>
Summing input E4 13
6 TMI
F H
avail. 15
10 MA
Current set point 10
11 Iist BRI- 0VL Controller
Current actual value 9
12 0VM BRO+ +24VL motor blocking brake
Reference potential 8
13 Tsense TMO
Tacho signal for 7 Evaluation
ext. use TMO motor thermostat contact
6
+15VM
-15VM
+24VL
4,5,6,7 0VM
0VL
BB
UD
5
frei
4
AS1 +24VL Controller
3 0VL starting lockout
AS2
2
8,9
ASQ
10
12
11
Acknowledgement
1
2
3
1
starting lockout
X1
ASQ
X8
L+
L-
X3
Supply module
feedin via electrical
Drive component
Bus connection
accessories
connecting
Busbars
cable
black
Anschlpl/TDM33
modules via
accessories
connecting
Supply for
additional
electrical
drive
AC 220 volt
additional
supply of
modules
ext. 24 volt unit fan
drive
M
(12 pole bus
Obsolete type
DC 300 volts
+24VL
processing
X73
ext. unit fan
(1)
(busbars)
Signal
0VL
cable)
Power
M
X49/4
X49/5
X74 F7
AC 220 volts
module X14
from supply
or drive
AC 115/220 volt
(1) Connection
L+
for optional
X8
L-
X1
unit fan:
12
1
Programming
220V
module
AC
Motor
MOD 17 / MOD 18
fan
M
X48
1 10 2
Bb 0VM
Ready to operate 2 Supply voltage 9 10
Bb +15VM
Motor feedback
1
X8
X50
Motor power
D
connection
A1 A2 A3
1 E1
Differential input 2 M
B
E2
3
3
Shield
A
Blocking Thermostat
4 E3
Summing input
contact
5 14
Summing input E4 TMI
E
Reference potential
6 0VM ϑ>
7 13
Controller voltage +15VM TMI
F H
8 12
ext. current peak limitation Ired BRO+
brakes
9 FB
avail.
10 11
Current set point MA BRO-
G
11 15
Current actual value Iist
12 10
Reference potential 0VM BRI- 0VL Controller
13 9
Tacho signal for Tsense BRI+ +24VL motor blocking brake
8
ext. use TMO
7 Evaluation
TMO motor thermostat contact
6
+15VM
-15VM
+24VL
5
4,5,6,7 0VM
0VL
BB
UD
frei
4
AS1 +24VL Controller
3 0VL starting lockout
AS2
2
ASQ
8,9
Acknowledgement
10
12
11
1
1
2
3
L+
L-
X3
Supply module
feedin via electrical
Drive component
Bus connection
accessories
connecting
Busbars
cable
black
Anschlpl/TDM43
AC 220 volt
additional
supply of
modules
drive
modules via
accessories
connecting
Supply for
additional
electrical
Obsolete type
X73
ext. unit fan
(1)
M
DC 300 volts
processing
M
+24VL
Power
Signal
0VL
X74 F7
AC 220 volts
module X14
from supply
or drive
AC 115/220 volt
X43/4
X43/5
(1) Connection
unit fan:
optional
for
L+
X8
L-
X1
12
1
220V
AC
Motor
fan
M
1
Bb
Ready to operate 2
Bb
X41
3
Controller enable signal RF 3
4
+24VL
feedback
use 8 rotor position acknowledgement BLC 3
Motor
0VM 7 8
9 rotor position acknowledgement BLC 2
-15VM 6 7
10 rotor position acknowledgement BLC 1
Temperature monitoring TÜ 5 4
Tacho voltage Tacho
9 2
X43
6
Programming
X8
module
MOD 19 / MOD 20
X42
Motor power
D
connection
A1 A2 A3
C
Differential input E1
M
2
E2
B
3
3
Shield
4
A
Blocking Thermostat
Summing input E3
contact
5
Summing input
6
E4 TMI 14
E
Reference potential
7
0VM ϑ>
Controller voltage +15VM 13
8 TMI
F H
-15VM
+24VL
3
4,5,6,7 0VM
0VL
BB
starting lockout
UD
AS2 0VL
2
ASQ Acknowledgement
1
ASQ starting lockout
8,9
10
12
11
X3
1
2
3
X1
X8
L+
L-
Supply module
feedin via electrical
Drive component
Bus connection
accessories
connecting
Busbars
cable
black
Anschlpl/TDM6
Power Signal
DC 300 volts processing
AC 220 volt
additional
Supply of
modules
drive
drive modules
the electrical
accessories
connecting
Supply for
additional
using
X73
ext. 24 volt unit fan
M
M
DC 300 volts
processing
bus cable)
+24VL
(busbars)
(12 pole
X74 F7
AC 220 volts
Power
module X14
Signal
from supply
0VL
or drive
AC 115/220 volt
X49/4
X49/5
(1) Connection
for optional
unit fan:
L+
X8
L-
X1
12
1
220V
AC
Motor
fan
M
Programming
module
X48
MOD 21 / MOD 22
10 2
0VM
1 Supply voltage 9 10
+15VM
Motor feedback
Bb
3
1
X49
X8
Motor power
D
connection
A1 A2 A3
M
X50
1 3
A
Blocking Thermostat
Differential input E1
contact
2 14
E2 TMI
3
E
Shield
4
ϑ>
Summing input E3 13
5 TMI
F H
Summing input E4 12
6 BRO+
brakes
-15VM
+24VL
3
4,5,6,7 0VM
0VL
BB
starting lockout
UD
AS2 0VL
2
ASQ Acknowledgement
1
ASQ starting lockout
8,9
10
12
11
X3
1
2
3
X1
X8
L+
L-
Supply module
feedin via electrical
Drive component
accessories
connecting
Bus connection
Busbars
cable
black
Anschlpl/TDM7
9.555.012.4
258 241