INVERTER AIR PLASMA CUTTING MACHINE
130LP
www.worldwel.com
■ TECHNICAL SPECIFICATIONS
- Usable at any plant by easy to change input voltage 220V, 380V, 440V
- Easy to verify cutting current by digital ammeter during cutting
- Cutting with air only, no need other gas
- Non contact arc starting by pilot circuit
- No need keeping to push torch switch during cutting by turning AUTO switch On which
is on front panel of power source
ITEM UNIT 130LP
Input Voltage V 220V/380V/440V, 1/3Ph
Frequency Hz 50/60
Rated Output Current A 130
Input Current @ rated output KVA 23
No Load Voltage V 273
Output Current Range A 35 ~ 130
Output Voltage V 120
Duty Cycle @ rated output % 60
Max. cutting thickness mm 25
Dimension (W×D×H) mm 400×780×640
Weight kg 62
■ Output Connection (Front of the machine)
․ Connect the work cable (which is connected to the work clamp) to the "+ METAL" terminal.
․ To connect the torch,
- Connect a electrode cable to the "- TORCH" terminal
- Connect a torch switch connector to the torch switch receptacle
- Connect a pilot wire to the pilot receptacle.
■ FRONT PANEL
1 Power Switch When it is turn on, the cooling fan and all of electrical circuit inside the machine will be operated.
2 Control Fuse (5A) It will be broken by any electrical problems
3 Current Adjust Volume Adjust the current
4 Power Lamp It indicates that the machine is on and input voltage is within acceptable range.
It indicates the thermal over load or output disabled by any electrical problems or the failure of
5 Warning Lamp
program. When it is on, the machine will not supply power at the output.
6 Pilot Switch Possible the non contact cutting with workpiece by pilot circuit.
7 Auto Switch If it is On, no need keeping to push torch switch during cutting
It is for checking the flow of the air. If this switch is ON, then the air is flowed by opening the
8 Air Check Switch
solenoid valve inside the machine.
9 Ammeter It indicates the cutting current
10 Air Pressure Indicator It indicates the air pressure
■ START UP
Turn On the main power supplied to machine
Turn On the power switch of machine and then verify that the power lamp is On and the cooling fan is running
Regulate the air pressure to 75PSI using the lever of air regulator when air check switch is ON
Select PILOT ON or OFF of the pilot selection switch
Select AUTO ON or OFF of the auto selection switch
Set the proper cutting current by the output current adjusting volume
Start cutting
130LP PARTS LIST
*Description can be changed by LOT number
NO. PART NAME DESCRIPTION QTY.
1 Magnet GMC-30P2 AC220V 50/60HZ 1
2 Main PCB WTM06[Ver.01] 1
3 HF PCB TMD-45A89 1
4 Control Transformer PCB VAC-01 1
5 MF Condensor 20㎌/1000V[LARGE] 4
6 MF Condensor 10㎌/800V[SMALL] 2
7 Condensor 2700/400V 2
8 Toggle Switch DWT-6210 1
9 Control Transformer 7642 2
10 Control Transformer 5719 1
11 Input Terminal 6M/M 1
12 NFB 3P-80A NDB3-100J4 80/3LTS 1
13 Pressure Meta 40/10 1
14 META PCB WPMD-01 1
15 FUSE 3A 1
16 VOLUME PCB WPVR-01 1
17 Resistor, Stick 100W5Ω 2
18 FAN-150T 150T [PIN TYPE] 1
19 FAN-120T 120T [PIN TYPE] 2
20 Regulator FR UNIT-TAW3000-03B 1
21 Slave PBC WPSB-01 1
22 Resistor, Discharge N20W10ΩJ 4
23 Output Diode DB2F150N6S,P6S 2
24 IGBT 600V,200A 2
25 IGBT Drive PCB WGE-01 2
26 InputBridgeDiode 6RI 100E-080 1
27 Temp. Switch N85 1
28 Pressure Sensor DP-07 1
29 Solenoid Valve TWIN DC24V 1.6/3M/M[HS-TW] 1
30 Terminal,MID MID 1
31 Terminal, Air NIPPLE(PLASMA) 1
32 Terminal Pilot OT SMALL (BLACK) 1
33 Connector K25-2R 1
34 Noise Filter PCB WTF-02 1
35 Pilot Surge PCB WNF-02 2
36 Induction coil 130LP 1
37 Choke Transformer 130LP 1
38 Coil 130LP 1
39 Main Transformer 130LP 1
40 Terminal MJ-175 1
41 PWD PCB WPD-02 1