Cummins 50kVA

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Diesel Powered

Generating Sets
S Range - 50Hz (3 Phase)

Standard Genset Features Generator Set Performance Generator Set Options

• Cummins water cooled Diesel Voltage Regulation : • PCC 1301 controller


engine, Maintains voltage output to within ±1%. • Coolant heater 230V, 300W
• Oil filter, standard fuel filter • At any power factor between 0.8 and 1.0. • Battery Charger ,12V 6 amps
• Lube-oil drain valve fitted • At any variations from no load to full load. • Electronic Governor
• Electric starter & Charge At any variations from Cold to Hot. • Sound attenuated canopy,
alternator 12V D.C. • At speed droop variations up to 4.0%. • 85 dB(A) at 1 meter
• Mechanical governor
• Heavy duty air filter Frequency Regulation
• Single bearing alternator, class • Isochronous under varying loads from no
H, IP23 load to 100% full load when electronic
• Exciter/Voltage reg - Torque governor is fitted.
Match as std • Random Frequency Variation Will not Voltage Connections
• Controller PCC 0301 with exceed ±0.25% of its mean value for • 230/400V, 3 Phase
display unit constant loads – no load to full load. • 240/415V, 3 Phase
• 3 pole MCB • 220/380V, 3 Phase
• Welded steel base frame with Waveform • 127/220V, 3phase
A/V mounting Total voltage harmonic distortion on open
• FRP fuel tank ,100 ltr cap. circuit is less than 1.8%. With 3 Phase non
• Tank capacity of min. 10 hours distorting balanced linear load is less than
operation at 5.0%.
• 70% standby load
• Set mounted starting battery Telephone Influence Factor (TIF) TIF
• Engine & Alternator Munsell less than 50.
Jade Green THF to BS 4999 Part 40 less than 2%.
• Radiator and Guarding black
• Packing under plastic bag Alternator Temperature Rise Class H
• Operation & Maintenance insulation.
manual
• Standard set of labels
• Soncap Certified Radio Interference
In compliance with BS EN 61000-6 and
VDE levels G and N.
Technical Data
Genset Model ES 43 D5 ES 55 D5 ES 68 D5
Genset Model ES 43 D5 ES 55 D5 ES 68 D5
Prime Power Rating kVA/kW 40/32 50/40 62/50
Standby Rating kVA/kW 43/35 55/44 68/55
Standby Rating Current (Amps) 61 77 96
Specific Fuel Consumption (gms/bhp-hr)
@ 100% Load 151 151 151
Model S3.8G4 S3.8G6 S3.8G7
BHP (Prime power) 52 65 76
Cooling Water cooled Water cooled Water cooled
Aspiration Turbocharged Turbocharged Turbocharged,After cooled
No of Cylinders 4 4 4
RPM 1500 1500 1500
Bore (mm) 97 97 97
Stroke (mm) 128 128 128
Compression Ratio 17.5:1 17.5:1 17.5:1
Displacement (ltrs) 3.8 3.8 3.8
Fuel Diesel ASTM No 2 Diesel Diesel ASTM No 2 Diesel Diesel ASTM No 2 Diesel
Governor Mechanical A2 Mechanical A2 Mechanical A2
Starting System 12V Electrical 12V Electrical 12V Electrical
Lube Oil Specification 15W40 15W40 15W40
Lube Oil Sump Capacity (ltrs) 9 9 9
Coolant Capacity (ltrs) 11 11 11
Exhaust Pipe Size (mm) 75 75 75
Make (Brand) Newage (Stamford) Newage (Stamford) Newage (Stamford)
Frame Size * UC224C UC224E UC224F
Std Voltage 415 volts 415 volts 415 volts
RPM/Frequency 1500rpm/50Hz 1500rpm/50Hz 1500rpm/50Hz
No. Phases 3 phase 3 phase 3 phase
Power Factor 0.8 (lag) 0.8 (lag) 0.8 (lag)
Voltage Regulator (Max) +/-1.0% +/-1.0% +/-1.0%
Class of Insulation H H H
Recommended Cable size (Cu Armoured) 25 sq.mm (31/2 core) 35 sq.mm (31/2 core) 50 sq.mm (31/2 core)
Controller PCC 0301 PCC 0301 PCC 0301
Battery 12V 120 AH 12V 120 AH 12V 120 AH

• Prime Power (PRP) is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a
variable electrical load when operated for an unlimited number of hours per year. The permissible average power output over 24 hours of operation
shall not exceed 70% of the PRP.
• Emergency Standby Power Rating (ESP) is defined as the maximum power available during a variable electrical power sequence, under
the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for
up to 200 hours of operation per year. The permissible average power output over 24 hours of operation shall not exceed 70% of the ESP.
• All ratings are based on the following reference conditions:
ƒ Ambient temperature - 27oC - Altitude above sea level - 150 meters - Relative humidity - 60%
Dimensions (mm)
OPEN ENCLOSED
Model ES 43 D5 ES 55 D5 ES 68 D5 ES 43 D5 ES 55 D5 ES 68 D5
Length 1800 1800 1830 2300 2300 2300
Width 730 730 800 1100 1100 1100
Height 1215 1215 1320 1650 1650 1650
Weight
(kgs.) 750 800 850 1250 1300 1350

CPGI/S50/09