0% found this document useful (0 votes)
135 views2 pages

BSB-310-Output Module-Monitored

This document summarizes an AutroSafe output module that provides four monitored output circuits. It features monitoring for breaks or shorts, plugs onto mounting rails, and addresses outputs automatically. The module outputs alarms to devices and routes faults. It complies with fire safety standards and has terminals to connect outputs and power.

Uploaded by

Irlan Leite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views2 pages

BSB-310-Output Module-Monitored

This document summarizes an AutroSafe output module that provides four monitored output circuits. It features monitoring for breaks or shorts, plugs onto mounting rails, and addresses outputs automatically. The module outputs alarms to devices and routes faults. It complies with fire safety standards and has terminals to connect outputs and power.

Uploaded by

Irlan Leite
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AutroSafe Output Module, Monitored - BSB-310

Features
• Provides four monitored output circuits
• Monitoring function for break or short-circuiting
• Easily plugged onto each other or onto other I/O
modules on a standard mounting rail
• Automatic addressing of the I/O module
• Designed to meet EN-54 and LPCB requirements,
and conforms to CE standards

Applications
The Output Module BSB-310 provides four moni-
tored output circuits for alarm sounders, fire-alarm
devices, fire-alarm routing equipment, fire-protection
devices and other fault outputs.

The I/O module is easily plugged onto a mounting Connections


rail inside the Fire Alarm Control Panel (BS-310/320)
or the Controller (BC-320).
Front view when mounted on rail
Each alarm circuit has its own freely programmable
address and signal frequencies. The standard fre-
quency is 2 Hz.

Each output is fused with a 1A self-resetting fuse. Screw


The outputs are continuously monitored to detect a terminal 10
possible break or short-circuit.
Screw
24V is supplied to the relay contacts via the internal terminal 1
bus, or in parallel via the screw terminals.

The I/O module will automatically detect its own ad- The I/O module has the following connections:
dress; no Dip-switch or jumper settings are required.
Screw Terminal no. Signal
1 Output AK1 - OV
2 Output AK1 + (+24V)
3 Output AK2 - (OV)
4 Output AK2 + (+24V)
5 Output AK3 - OV
6 Output AK3 + (+24V)
7 Output AK4 - OV
8 Output AK4 + (+24V)
9 Internal input only 24 VBAT
10 Internal input only 0 VBAT

The output AK4 may be configured to be used as a


monitored Fault Warning Routing Equipment
(FWRE) output (an output which routes a fault-
warning signal to a fault-warning signal receiving-
station).

P-BSB310/CE - Rev. D, 040514 Protecting life, environment and property...


Output Module, Monitored - BSB-310

Technical Specifications Installation Overview


Dimensions (mm) 95x89x32
Weight (g) 81
Materials Top and bottom: Zytel
FR7200
Output
Snap-on mounting device: Module A utronica A utronica Autronica
End of line resistor
Zytel 7335S
Electrical connection Internal system: plug-in
connection
Outputs: screw terminals
(maximum cable dimension
2,5mm2)
Mounting Onto a standard mounting Schematics - Monitored Output
rail inside the Fire Alarm
Control Panel or Controller.
Control outputs: four pieces Voltage: 24V DC
monitored Maximum load: Terminal point 2, 4, 6, 8
1A each output +
24V_BAT
3A total
Sense
Electronic fuse: -
Terminal point 1, 3, 5, 7
Trip current: 2,2 A per
output at 25°C
End of line resistor 2000 Ohm Monitoring
Internal current consumption 24VREG, idle: 10 mA

24VREG, 12,5%
communication capacity: 26
mA Schematics - Fault Warning Routing Equipment
Output resistance accuracy on +/-25% (FWRE) Output, output 4 only
the loop
Output monitoring – short- < 200 Ohm
Ext FW Routing Eq
circuit
Output monitoring – normal 1000 - 3000 Ohm 8
(Not connected)
Output monitoring – break > 3000 Ohm 24V_BAT
Sense FWRE

7
Order Number
0V_BAT
Order Description Ship Weight
number metric/imperial
BSB-310 Output Module, Monitored

N.B. At inductive load, a protection diode must be


used.