Altic

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

UGAM TECHNOLOGY

AN ISO 9001:2015 COMPANY


AN ISO 14001:2015 COMPANY

ALTIC007
FIRE STOP COATING FOR ELECTRICAL CABLES
TECHNICAL SPECIFICATIONS

PRECAUTION IS BETTER THAN CURE BUT THERE IS NO CURE IN CASE OF


FIRE SO DON’T TAKE CHANCE USE ALTIC 007

ALTIC 007
INTUMESCENT FIRE RETARDANT PAINT
CERTIFICATION

ALTIC 00 7FIRE RETARDANT PAINT is Tested and Certified for Circuit Integrity for 4 hours
from NATIONAL TEST HOUSE MUMBAI.

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

Characteristic Specification
PRODUCT ALTIC 007 FR INTUMESCENT CBLE
COATING

HSNCODE 32099020

TYPE Water base ,Intumescent, fire retardant, flexible


and thin coating for cables and cable trays

COLOR Off white/special shades can be manufactured

FINISH Mat

CURING Surface dry 60 min


Track free dry 8 hrs
Hard dry 48 hrs

DRYING Air-drying paint

APPLICATION Brush or air less spray

NON-VOLATILE MATTER Min 70%

SCRATCH HARDNESS No such scratch as to show the bare surface

FLEXIBILITY AND ADHESION No visible damage or detachment of the film


AFTER 48 HOURS AIR DRYING

WATER/ACID/ALKALI/OIL No effect in mild application

SHELF LIFE One year

WATER IMMERSION No effect after immersion for 360 hours

RADIATION No effect

EFFECT ON CABLE JACKETING No effect


MATERIAL
SOLVENT Water

VOC Less than 100 gm/Kg

COVERAGE
REQUIRED FIRE RATING COVERING (SQUARE FOOT/KG) DFT (microns)
30 minutes 24-25 500
1 hour 10-12 1000
2 hours 5-6 2000
3 hours 4 3000
4 hours 2.5-3 4000

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

DESCRIPTION

Expands up to10times the original size when exposed to heat/fire prevents the cable to be

exposed to heat/fire. Can be used as – cable Penetration product, cable coating, cable trays

coating, wood or flammable and flexible product’s coating. Being halogen free and toxic

gasses emission free, ALTIC007 is the most suitable product available in the market.

1. ALTIC007passes the Test Safe`s following tests.

2. Flammability testing of materials and substances, combustion.

3. Product analysis with heat, toxicity and smoke yield.

4. Explosive testing of materials, including flammable gasses, dusts, and vapours.

5. It also passes bench scale flammability test.

ALTIC-007passes the NFPA 703 test for fire retardant Impregnated wood and fire-

retardant coatings for building materials.

ALTIC007passes following tests as per ASTM. –very much within the range of

NFPA approval.

>Flame spread test as per ASTME-162:01

>Smoke generation test as perASTME-662:06.

>Surface burning test as per ASTM E-84.

>Cabinet method fire retardancy test as per ASTM D-1360.

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

ADVANTAGES

1) Thin film coating approximately 500 microns provides reliable fire protection without

causing premature ageing or over heating of cables.

2) Halogen and asbestos free coating.

3) Rating of electrical cables is not reduced.

4) Escape routes and power supply can be used for longer time.

5) Flame spread and insulation damages are delayed in case of prolonged exposure to fire.

6) Minimize smoke generation thereby permitting use in enclosed areas.

7) Burning drips and burning cable fragment drops are minimized to great extent.

8) Coated surfaces will not catch fire or ignite or spread fire.

9) Meets many stringent international fire standards.

10) Best coating with the highest fire protection amongst the coatings of this class.

11) Chemically converts nitrogen oxide and chlorine produced during burning of cables to foam

and charring material thereby reducing the possibility of toxic gasses emission.

12) Long lasting and can be used as outdoor/indoor/or even at places containing high moisture.

13) If coated with epoxy topcoat/varnish ,lifelong performance can be achieved.

14) Being flexible ,it is very much suitable for cables .Does not crack when cables are bent.

Continuous to and from movements also do not affect the performance of the coating.

15) Being water base, and non-toxic, it is eco-friendly.

16) Can be coated by brush/air less spray.

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

APPLICATIONPROCEDURE

Areas should be cleaned, dried and made free from oil and dust . Surface temperature should be

greater than 20degrees C. Stir the can properly. Observe the viscosity for brushing / airless spraying.

Add soft water if required. Apply minimum two coats or as per requirement to achieve 500 microns

dry film thickness. If smooth and decorative finish is required apply UGAM EPOXY TOP COAT

(suitable for intumescent coating). No primers required for this system if to be applied over cables.

But if application is over metallic surfaces, ALTIC ZINC RICH PRIMER should be applied.

PACKINGANDSHELFLIFE
Packing: 20Kg buckets.

Shelf life: Min. one year


Storage: cool and dry place free from freezing

TESTANDAPPROVALS–ALTIC007
DETAILS OFTESTSPASSED

1. A L T I C 0 0 7 passes the Test Safe`s following tests.

A. Flam ability testing of materials and substances, combustion.

B. Product analysis is with heat, toxicity and smoke yield.

C Explosive testing of materials, including flammable gasses, dusts, and vapors.

D. It also passes bench scale flammability test.

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

2. ALTIC007 passes the NFPA 703 test for fire retardant Impregnated wood and fire retardant

coatings for building materials.

3. ALTIC007passesfollowingtestsasperASTM.-verymuchwithintherangeofNFPAapproval.

>Flame spread test as per ASTME-162:01

>SmokegenerationtestasperASTME-662:06.

>Surface burning test as per ASTME-84.

>Cabinet method fire retardancy test as per ASTM D-1360.

PROJECTS COMPLETED

1. Mylan laboratories Ltd (PAN India Bases)

2. Scheinider Electricals

3. Pidilite Industries (PAN India Bases)

4. ONGC LTD

5. Ozone Spinter Ltd

6. HCL Technologies Ltd

7. Ravi Export Ltd

8. Indian Army –J&K

9. Jonson & Jonson ……

TESTINGVIDEOLINK:

ALTIC007-IN-TUMESCENTFRCOATINGFORCABLE

https://drive.google.com/open?id=1oX_3kR1Z3f2bu-dl5WEXGV9GZ1w3zazv

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

Manufactured by:UGAM TECHNOLOGY VADODARA GUJARAT-390008


AN ISO CERTIFIED 9001:2015COMPANY.

The technical specification is correct to the best of our knowledge and under test conditions and
we do not accept any liability towards misuse and contents of it. Product must be tested for
specific use prior to use.

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802
UGAM TECHNOLOGY
AN ISO 9001:2015 COMPANY
AN ISO 14001:2015 COMPANY

UGAM TECHNOLOGY
406-407OrchidPlazaBh/McDonald’sMainSamaSavaliRoadVadodra-390008
[email protected]
Ph.No-+91-8410010286/9925810802

You might also like