0% found this document useful (0 votes)
38 views2 pages

Apolo Textil Demo EthernetIP Parameters

This document summarizes modified parameter settings for a Yaskawa A1000 CIMR-A drive model. Over 50 parameter values were changed from their default settings, including control method, operation mode selection, acceleration/deceleration times, frequency references, motor setup values, option card communication settings, digital input/output functions, motion setup type, and homing settings. The modified parameter settings indicate non-default configuration of the drive for a particular application.

Uploaded by

Abraham Lara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views2 pages

Apolo Textil Demo EthernetIP Parameters

This document summarizes modified parameter settings for a Yaskawa A1000 CIMR-A drive model. Over 50 parameter values were changed from their default settings, including control method, operation mode selection, acceleration/deceleration times, frequency references, motor setup values, option card communication settings, digital input/output functions, motion setup type, and homing settings. The modified parameter settings indicate non-default configuration of the drive for a particular application.

Uploaded by

Abraham Lara
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Modified Parameter Settings Report (Program) 20/07/2022 11:44:10 a. m.

Program (Drive Selected / Connected):

Drive Type / Model: A1000 CIMR-A*2*0006***


Software: 10070 (Motion Control)

Project:
User:

Information

Default
Parameter Value Information Setting
A1 Initialization
A1-02 Control method 3 Flux vector 2
b1 Operation Mode Selection
b1-01 Reference selection 3 Option card 1
b1-02 Operation method selection 3 Option card 1
C1 Acceleration and Deceleration Times
C1-01 Acceleration time 1 1.0 sec 2.0 sec
C1-02 Deceleration time 1 1.0 sec 2.0 sec
C1-03 Acceleration time 2 1.0 sec 2.0 sec
C1-04 Deceleration time 2 1.0 sec 2.0 sec
d1 Frequency Reference
d1-09 Frequency reference 9 10.00 Hz 6.09 Hz
d1-10 Frequency reference 10 10.00 Hz 6.10 Hz
d1-16 Frequency reference 16 2.00 Hz 6.16 Hz
E1 Motor 1 V/f Pattern Characteristics
E1-13 Base voltage 230.0 VAC 0.0 VAC
E2 Motor 1 Setup
E2-01 Motor rated current 3.00 A 4.90 A
E2-02 Motor rated slip 1.20 Hz 2.60 Hz
E2-03 Motor no-load current 1.98 A 2.30 A
E2-05 Motor line-to-line resistance 3.918 Ohm 3.577 Ohm
E2-06 Motor leak inductance 14.4 % 18.5 %
E2-07 Saturation Comp 1 0.47 0.50
E2-08 Saturation Comp 2 0.73 0.75
E2-11 Motor rated output 0.75 kW 1.10 kW
F1 PG Option
F1-01 PG constant 1000 PPR 1024 PPR
F1-05 PG rotation 1 Phase B leads with forward run command. 0
F6 Option Card 1 Serial Communication
F6-14 BUS Error Auto Reset 1 Enabled 0
F7 Option Card 2 Serial Communication
F7-13 Address Startup Mode 0 User defined 2
F7-15 Speed Mode Setting 100 100Mbps speed setting 10
F7-23 Dynamic Output Assembly 116 Parameter 1 0288 0000

DriveWizard Industrial for Windows (C) by Yaskawa America, Inc. 1/2


Default
Parameter Value Information Setting
F7-24 Dynamic Output Assembly 116 Parameter 2 028B 0000
F7-25 Dynamic Output Assembly 116 Parameter 3 0200 0000
F7-26 Dynamic Output Assembly 116 Parameter 4 0201 0000
F7-27 Dynamic Output Assembly 116 Parameter 5 0202 0000
F7-28 Dynamic Output Assembly 116 Parameter 6 0203 0000
F7-29 Dynamic Output Assembly 116 Parameter 7 060B 0000
F7-30 Dynamic Output Assembly 116 Parameter 8 060F 0000
F7-31 Dynamic Output Assembly 116 Parameter 9 0291 0000
F7-33 Dynamic Input Assembly 166 Parameter 1 0049 0000
F7-34 Dynamic Input Assembly 166 Parameter 2 004A 0000
F7-35 Dynamic Input Assembly 166 Parameter 3 004B 0000
H1 Multi-Function Digital Inputs
H1-03 Terminal S3 function selection 82 Home Command 24
H1-04 Terminal S4 function selection 83 Home Switch 14
H1-05 Terminal S5 function selection 84 Positive Over-travel Limit Switch 03
H1-06 Terminal S6 function selection 85 Negative Over-travel Limit Switch 04
H1-07 Terminal S7 function selection 80 Move 06
H1-08 Terminal S8 function selection 87 Distance Select A 08
H2 Multi-Function Digital Outputs
H2-01 Terminal M1/M2 Selection 0041 Move Complete 0000
H2-02 Terminal M3/M4 Selection 0042 Homing Complete 0001
H2-03 Terminal M5/M6 Selection 0043 Homing Needed 0002
P1 Motion Setup
P1-01 Motion Type 1 Linear Absolute 0
P1-02 Distance Select 2 Option Card 0
P1-03 Move Cmd. Type 1 Rising Edge 0
P1-09 Counts Per Unit 400 cts 4096 cts
P1-10 Distance Units 3 Centimeters 0
P2 Homing Setup
P2-02 Homing Speed 30.0 Hz 10.0 Hz
P2-06 Homing Offset Dist 20.00 cm 0.00 cm

DriveWizard Industrial for Windows (C) by Yaskawa America, Inc. 2/2