0% found this document useful (0 votes)
17 views

Variables

The document defines a data block called TAMESAMPUERO_Variables containing variables to represent the inputs and outputs of an automation system. The data block contains two structures - one called Entradas to store the input values, and one called Salidas to store the output values. Each structure contains multiple boolean variables to represent sensors, switches and signals. All variables are visible from the HMI and web interface, and writable from the HMI, engineering station and web interface/API.

Uploaded by

deybyklk
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views

Variables

The document defines a data block called TAMESAMPUERO_Variables containing variables to represent the inputs and outputs of an automation system. The data block contains two structures - one called Entradas to store the input values, and one called Salidas to store the output values. Each structure contains multiple boolean variables to represent sensors, switches and signals. All variables are visible from the HMI and web interface, and writable from the HMI, engineering station and web interface/API.

Uploaded by

deybyklk
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Totally Integrated

Automation Portal

SPA_Practica2.3_deyby / PLC_deyby [CPU 1515-2 PN] / Program blocks


TAMESAMPUERO_Variables [DB1]
TAMESAMPUERO_Variables Properties
General
Name TAMESAMPUERO_Varia‐ Number 1 Type DB
bles
Language DB Numbering Automatic
Information
Title Author Comment
Family Version 0.1 User-defined
ID

TAMESAMPUERO_Variables
Name Data type Offset Start value Retain Acces‐ Wri Visi‐ Set‐ Super‐ Comment
sible ta‐ ble in point vision
from ble HMI
HMI/O fro engi‐
PC m neer‐
UA/W HM ing
eb API I/O
PC
UA/
We
b
API
Static
Etapas Ar‐ 0.0 False True Tru True False
ray[0..6] e
of Bool
Etapas[0] Bool 0.0 false False True Tru True False
e
Etapas[1] Bool 0.1 false False True Tru True False
e
Etapas[2] Bool 0.2 false False True Tru True False
e
Etapas[3] Bool 0.3 false False True Tru True False
e
Etapas[4] Bool 0.4 false False True Tru True False
e
Etapas[5] Bool 0.5 false False True Tru True False
e
Etapas[6] Bool 0.6 false False True Tru True False
e
Entradas Struct 2.0 False True Tru True False
e
SD (Sensor Bool 2.0 false False True Tru True False
llenado) e
SS (Contador) Bool 2.1 false False True Tru True False
e
Marcha Bool 2.2 false False True Tru True False
e
Paro Bool 2.3 false False True Tru True False
e
Reserva1 Bool 2.4 false False True Tru True False
e
Reserva2 Bool 2.5 false False True Tru True False
e
Totally Integrated
Automation Portal

Name Data type Offset Start value Retain Acces‐ Wri Visi‐ Set‐ Super‐ Comment
sible ta‐ ble in point vision
from ble HMI
HMI/O fro engi‐
PC m neer‐
UA/W HM ing
eb API I/O
PC
UA/
We
b
API
Reserva3 Bool 2.6 false False True Tru True False
e
Reserva4 Bool 2.7 false False True Tru True False
e
Reserva5 Bool 3.0 false False True Tru True False
e
Reserva6 Bool 3.1 false False True Tru True False
e
Reserva7 Bool 3.2 false False True Tru True False
e
Reserva8 Bool 3.3 false False True Tru True False
e
Reserva9 Bool 3.4 false False True Tru True False
e
Reserva10 Bool 3.5 false False True Tru True False
e
Reserva11 Bool 3.6 false False True Tru True False
e
Reserva12 Bool 3.7 false False True Tru True False
e
Salidas Struct 4.0 False True Tru True False
e
M (Cinta) Bool 4.0 false False True Tru True False
e
K1 (Tolva) Bool 4.1 false False True Tru True False
e
Luz verde Bool 4.2 false False True Tru True False
e
Luz amarilla Bool 4.3 false False True Tru True False
e
Luz roja Bool 4.4 false False True Tru True False
e
Reserva13 Bool 4.5 false False True Tru True False
e
Reserva14 Bool 4.6 false False True Tru True False
e
Reserva15 Bool 4.7 false False True Tru True False
e
Reserva16 Bool 5.0 false False True Tru True False
e
Reserva17 Bool 5.1 false False True Tru True False
e
Reserva18 Bool 5.2 false False True Tru True False
e
Reserva19 Bool 5.3 false False True Tru True False
e
Reserva20 Bool 5.4 false False True Tru True False
e
Reserva21 Bool 5.5 false False True Tru True False
e
Totally Integrated
Automation Portal

Name Data type Offset Start value Retain Acces‐ Wri Visi‐ Set‐ Super‐ Comment
sible ta‐ ble in point vision
from ble HMI
HMI/O fro engi‐
PC m neer‐
UA/W HM ing
eb API I/O
PC
UA/
We
b
API
Reserva22 Bool 5.6 false False True Tru True False
e
Reserva23 Bool 5.7 false False True Tru True False
e
Temporizador Struct 6.0 False True Tru True False
e
Int Bool 6.0 false False True Tru True False
e
Q Bool 6.1 false False True Tru True False
e
Contador Struct 8.0 False True Tru True False
e
Int Bool 8.0 false False True Tru True False
e
Q Bool 8.1 false False True Tru True False
e
Q_1 Bool 8.2 false False True Tru True False
e
Q_2 Bool 8.3 false False True Tru True False
e
Q_3 Bool 8.4 false False True Tru True False
e
Q_4 Bool 8.5 false False True Tru True False
e
Reset Bool 8.6 false False True Tru True False
e
contaje Int 10.0 0 False True Tru True False