Revision History
Revision History
Updated Description
No Category
version No.
734 1.052E Add new function As for the options for converting, a function to select a level to maximize the number of steps of the program has
Improve Initial setting for the verification of device memory for FX5CPU has been improved so that SM/SD device was
733 1.052E
operability excluded from the verification target.
<Important>Following problems found in conversion function has been solved.
In some cases;
- When adding local label to a project in which global label declaration has been included and converting the
program, local labels were not assigned and conversion might not be completed.
- Incorrect conversion error (0x12121030) might occur in converting after selecting 'Yes' for the 'Optimize the Number
of Steps' in Options.
- A conversion error might occur when deleting a local label included in subroutine type FB and adding rising/falling
732 1.052E -
instruction for the subroutine type FB.
- As for the 'Open GX Works2 Format Project' function, a conversion error might occur when a specific general FUN
was included in the ST program (including inline structured text) which was read.
- A conversion error (0x110E1B01) might occur when a general FUN was imported to the FB at the 32nd level of the
hierarchy and was converted.
- A conversion error might occur in adding a number of rising/falling instructions to the subroutine type FB calling
macro type FB.
Following problems found in 'Rebuild All' -> 'Write to PLC' have been solved.
In some cases;
- Unexpected value might be returned from the output side of input/output argument of macro type FB.
- A CPU error (3202) might occur when using a return element for a program of macro type FB.
- A CPU error (2820) might occur when connecting indirect specification device to call with the array type argument of
macro type FB.
- As for a SFC program, a CPU error (3140) might occur when writing to PLC with direct expression specified to
transition after deleting action of a initial step.
- When a MOV instruction is connected to a bit type output argument of macro type FB, the macro type FB or the
MOV instruction might not correctly work.
731 1.052E -
- When deleting FB instance and adding a different data type FB instance, rising/falling instruction might not correctly
work.
- As for the substitution of structures including bit type array as member, substituted structure member might show an
incorrect value and not correctly work if bit type array member of one side has manually been assigned.
- When an inverse instruction has been set for the argument of macro type FB, macro type FB might not correctly
work .
- A monitor error occurred when a timer type label was set for the bit type input argument of macro type FB, and it
might be failed to monitor.
- As for the macro type FB (with EN/ENO pins) including multiple bit type output arguments, different bit type output
argument was turned OFF when EN was turned ON.
Following problems found in FBD/LD, SFC diagram editor have been solved.
- When opening program editor and setting LD or FB element while 'Meiryo' has been specified in Font setting,
728 1.052E -
elements and labels were inadequately displayed.
-Following
Changingproblems
colors forfound
comment elements
in FBD/LD and
editor changing
have text layout were enabled while monitoring (Read Only).
been solved.
- Unable to operate editor and the behavior of GX Works3 might be unstable when pasting user FB newly from
element selection window.
727 1.052E -
- Memory shortage error might occur in converting when the output of FB was branched and connector element was
used.
1/31
Following problems found in ladder editor have been solved.
- In some cases, editing inline structured text might be disabled in changing mode from Read Monitor to Write
726 1.052E - Monitor.
- In some cases, font size might not be correctly shown after changing it from View menu while 'Autofit Text Size' has
been enabled in Options.
Following problems found in Verify with PLC function has bee solved.
- In some cases, mismatch of module parameter might occur when 'Verify with PLC is executed after executing 'Write
to PLC'.
725 1.052E -
- In some cases, conversion status might change from a converted one to an unconverted one in executing
'Converted Result Verification' of verification result for a project in which a FB instance has been set to a global label.
The following problem found in System Parameter setting has been solved.
724 1.052E -
Any error did not occur even if the setting for the start XY has been overlapped.
The following problem found in Read from PLC has been solved.
723 1.052E -
In some cases, a warning message for PROFIBUS module might be displayed.
The following problem found in opening a project including ladders has been solved.
722 1.052E -
In some cases, GX Works3 might not correctly work when pressing Ctrl+Pause multiple times.
The following problem has been solved.
721 1.052E -
Unable to delete module FB in units of POUs by deleting data function in Navigation window.
The following problem found in importing XML has been solved.
720 1.052E -
An error occurred when an array was used for input/output label of FB data imported to ladder.
The following problem has been solved.
719 1.052E -
Structures were not restored when executing batch reading from MELSOFT Navigator.
The following problem found in library operation function has been solved.
718 1.052E -
Structures used for returned value were not imported when functions were imported from Library.
The following problem has been solved.
717 1.052E -
In some cases, column width might be changed when Refresh setting of Intelligent Function Module was changed.
The following problem found in adding new module has been solved.
716 1.052E -
Base Mounting Type General Module was not shown in selection field of module type.
The following problem has been solved.
715 1.052E -
Device list was not correctly shown for the device to use for instruction in which an argument(n) was included.
The following problem has been solved.
714 1.052E -
Device list was not correctly shown for the device to use for the GX Works2 compatible instruction.
The following problem has been solved.
713 1.052E - As for the function to reflect the change of the module start I/O No. to related data, GX Works2 compatible instruction
(xxx_M2) was excluded from find target.
The following problem found in Device Batch Replace has been solved.
712 1.052E - All the number of points to be replaced might not be replaced when two or more number of points has been set to a
constant device.
The following problem found in CC-Link Diagnostics of FX5CPU has been solved.
711 1.052E - Unable to execute circuit test when the Intelligent Module No. does not match with the attached position No. of the
module.
Modules for MELSEC iQ-R series shown below have been supported.
- Main Base Module (R33B)
Support new
710 1.050C
modules
- HART-enabled analog-digital converter module (R60ADI8-HA)
- Channel Isolated Pulse Input Module (RD60P8-G)
- Energy Measuring Module (RE81WH)
Modules for MELSEC iQ-R series shown below have been supported.
- CPU Module (FX5UC-32MR/DS-TS)
- Output Module (FX5-C16EYR/D-TS)
Support new
709 1.050C
modules
- Positioning Module (FX5-20PG-D)
- Ethernet Module (FX5-ENET)
- PROFIBUS@-DP Module (FX5-DP-M)
Support new A module for CC-Link IE Field Network shown below has been supported.
708 1.050C
modules - CC-Link IE Field Network Block Type Remote IO-Link Module (NZ2GF2S-60IOLD8)
Functions shown below have been supported for RnCPU (R00CPU, R01CPU, R02CPU, R04CPU, R08CPU,
R16CPU, R32CPU, and R120CPU) and CC-Link IE Built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU,
Support new R32ENCPU, and R120ENCPU).
707 1.050C
modules - Communications by Network No./Station No.
- SFC Activated Step Monitor
- Specifying communication target for iQ-F series CPU modules for Simple PLC Communication
2/31
Support new Register/Cancel Forced Input/Output function has been supported for RnSFCPU (R08SFCPU, R16SFCPU,
706 1.050C
modules R32SFCPU, and R120SFCPU).
Functions shown below have been supported for the Redundant Mode of RnCPU (R08PCPU, R16PCPU, R32PCPU,
Support new and R120PCPU).
705 1.050C
modules - SFC Program
- Setting to Wait Receiving Cyclic Data after Switching System
The following functions have been supported for RJ71EN71 and RnENCPU (network part).
Support new
704 1.050C
modules
- Simple PLC Communication
- MODBUS/TCP Communication
Functions shown below have been supported for C language Intelligent Function Module (RD55UP06-V).
- Data Analysis Library
Support new - MT method function (Generate unit space, Obtaining Mahalanobis distance)
703 1.050C
modules - Multiple regression analysis function
- Data analysis dedicated instruction and data analysis FB
- Updating firmware function with SD Memory Card
Functions shown below have been supported for MELSEC iQ-F series.
Support new - Simple PLC Communication
702 1.050C
modules - System Monitor
- Sensor/Device Monitor of AnyWireASLINK
701 1.050C Add new function
Accessing to RnPSFCPU (R08PSFCPU, R16PSFCPU, R32PSFCPU, and R120PSFCPU) with GOT transparent
function has been supported for Connection Destination Setting.
Functions shown below have been supported for ladder programs.
- Displaying a ladder of an undefined FB/FUN whose definition is deleted or changed.
- Copying a program including FB/FUN ladder to another project even if FB/FUN definition has not been included in
the paste target program.
700 1.050C Add new function - Individually scroll the window of the programs divided to side by side.
- Automatically adjust font size according to the display magnification.
- Automatically adjust display magnification according to the window width.
- Displaying monitor value of an argument device based on the data type of input/output label of general FB/FUN.
3/31
683 1.050C
Improve Function related to CC-Link IE Field Configuration window has been improved so that the lastly selected assignment
operability method can be selected when it is opened next time.
682 1.050C
Improve Sensor/Device Monitor can be shown when connecting GX Works3 with submaster station operated as a master
operability station of CC-Link IE Field via USB.
Improve Required time to write the program of RnCPU (R08PCPU, R16PCPU, R32PCPU, and R120PCPU) has been reduced
681 1.050C
performance by skipping the writing of an unchanged file.
<Important> Following problems found in Convert or Rebuild All have been solved.
In some cases;
- FB might not correctly work when deleting subroutine type FB instance from a project and newly adding FB instance
and converting it.
- Subroutine type FB might not correctly work when editing and converting local labels of subroutine type FB which
680 1.050C -
was called from subroutine type FB.
- FB might not correctly work when editing local labels of the subroutine type FB and newly adding the instance of the
corresponding subroutine type FB.
- FB might not correctly work when converted program blocks were converted after moving them to another program
file.
Following problems found in Convert function have been solved.
- As for ladder programs, automatically tracked labels might be converted to global labels but not local labels if
names of global labels on label editor were the same ones for local labels.
- In some cases, program might not correctly work as specified by type when device type specifier was specified for a
679 1.050C - device using index modification and used as an argument for a general function.
- In some cases, a conversion error was not returned even when a data type label different from the one for
instruction argument was specified under the setting that 'No' was selected for 'Check the data type of instruction
argument' in Options, and program might not correctly work.
677 1.050C -
The following problem found in Convert or Rebuild All (Retain) has been solved.
In some cases, program conversion status might not be the converted one even if no conversion error was found.
The following problem has been solved.
676 1.050C - In some cases, unable to write to PLC when a FB in a FB file in which all FBs were unused were imported to an
unregistered program.
675 1.050C -
The following problem found in Read from PLC function has been solved.
In some cases, structures might be read in reading safety module parameters.
The following problems found in ladder editor have been solved.
In some cases;
- A memory shortage error might occur in copying and pasting between the projects of different models.
- Pointer might not be pasted when selecting range including pointer input area and copying and pasting for ladder blocks including
FB/FUN.
- An error message might be shown when a program block using nested FB was imported from library to project.
- Continuous pasting might not correctly work when copying and pasting was executed after selecting ladders of multiple rows.
- Inputting contacts might be disabled at the input argument side of bit types of FB/FUN.
- Pasting might not correctly work when selecting multiple ladders including notes and copying and pasting.
- Window scrolling might be slow when FB/FUN including 40 or more arguments.
- Editing ladders might be disabled when 'Region and Language' of Windows was changed.
- A memory shortage error might occur in creating vertical line at the title of FB on the ladder.
- Jumping from statement list might take time.
- A memory shortage error might occur in exporting to files when FB in which 2 or more local labels of VAR_PUBLIC or
674 1.050C - VAR_PUBLIC_RETAIN were defined on the program.
- An error message might be shown in scrolling window and clicking a ladder after a program including MC or MCR instruction was
displayed with the window divided.
- Scrolling on monitoring might take time when a global label in which an assignment label was set was used with bit specified.
- Editing operation might take time in specifying local label of constant for the array element of a global label after enabling the
'Display Comment of Assigned Device'.
- GX Works3 might not correctly work when creating a circular reference function and editing its local label.
- Stopping monitor might take time when multiple programs including FB were displayed.
- As for a FB including input argument of both of bit type and other than bit type, a memory shortage error might occur in editing
instance name of FB when connecting to 2 or more coils from an output argument.
- When input label of different FB instance was connected to the output argument of FB and converted, an uninput contact might be
shown.
4/31
Following problems found in SFC have been solved.
- In some cases, replacing might take time if the number of blocks of a ladder which was set as Action/Transition
exceeded 1000.
673 1.050C - - A memory shortage error might occur in opening Zoom after switching ladder display for an unconverted Zoom in
which calling FB/FUN was included.
- GX Works3 might not correctly work when the jump destination within a selection branch was changed.
The following problem found in FBD/LD or SFC program has been solved.
672 1.050C - When labels of the same name with different case sensitivity was specified to local label, changed contents of
FBD/LD or SFC editor might not saved to the project.
The following problem has been solved.
671 1.050C -
When a parameter process window of slave station was shown from the network configuration diagram of CC-Link IE
Field Network, some of the buttons could not be pressed under the environment that display language was English
and display resolution was 768 vertically.
670 1.050C -
The following problem found in the module parameters of CC-Link IE Field Network has been solved.
In some cases, setting safety communication might be failed for MR-J4-GF.
The following problem has been solved.
669 1.050C - When the start XY were changed in module configuration diagram, I/O No. specification device (Un) or Intelligent
Function Module device (Un\GN) were not found in label editor.
668 1.050C -
The following problem found in Verify function has been resolved.
Unable to 'Export to File' of device memory from Verification Result (Detailed Display) window.
667 1.050C -
The following problem has been solved.
Devices used for DMAX, DMIN, EDMAX, EDMIN, EMAX, and EMIN instructions were not correctly shown in Device
666 1.050C -
The following problem has been solved.
When 2 or more Z or LZ devices were used, only 1 device were shown in Cross Reference and Device List.
The following problem has been solved.
665 1.050C - 'Error accessing file' error might occur in writing to Simulator under Windows environment that 'Disable 8.3 file name
creation' has been set.
664 1.050C -
The following problem found in redundant system of PROFIBUS-DP module (RJ71PB91V) has been solved.
In some cases, GX Works3 might not correctly work in executing 'Write to PLC' during monitoring.
The following problem has been solved.
663 1.050C - In some cases, unable to open a project if it was saved while the Device/Buffer Memory Batch Monitor window and
the Active Step Monitor window for All SFC Blocks Batch Monitor are opened.
The following problem found in Confirm Memory Size has been solved.
662 1.050C - In some case, the calculation result of program memory might not be correctly shown when unconverted program file
or FB/FUN file was selected to calculate.
661 1.050C -
The following problem found in Error Jump function of Module Diagnostics has been solved.
In some cases, jumping might not correctly work when a folder was included in a program file.
The following problem found in the function related to CC-Link Diagnostics has been solved.
660 1.050C - In some cases, GX Works3 might not correctly work when 7 or more refresh settings were set to the module
parameter of RJ61BT11 (CC-Link).
Following problems found in Open GX Works2 Format Project have been solved.
- GX Works3 did not correctly work when specifying a project including an undefined FB created by ladder language.
- In some cases, an error might occur when specifying a project including serial communication module to which
'Execution log options' or 'Echo back enable/disable setting' has been set.
659 1.050C - In some cases, GX Works2 compatible instructions might not correctly work.
- As for FBD/LD program, system might not correctly work when the output of rising/falling instruction was branched.
- As for ST and FBD/LD program, a CPU error (2080) might occur when a returned value of instruction was specified
as an argument of the instruction.
The following problem has been solved.
658 1.050C -
In some cases, GX Works3 might not correctly work when Version 1.040S or later ones are overwritten/installed
(including update) to the personal computer in which Version 1.001B or earlier ones have been installed.
5/31
The following problems found in 'Online Program Change' or 'Rebuild All' -> 'Write to PLC' have been solved.
- As for a subroutine type FB or user FUN program, a CPU error (3100) might occur when DX/DY was used as an
argument of transfer instruction.
- As for a local labels included in subroutine type FB, a CPU error (2820) might occur when a subroutine type FB was
added to FB instance after deleting labels.
654 1.047Z - - As for a SFC program, a CPU error (3140) might occur when a series connection or a parallel connection was used
in multiple transitions.
- As for a ladder program, a CPU error (3142) might occur when an inline structured text was added to user FUN.
- Writing might fail when:
Execute 'Write to PLC' for a project using a structure for an unused FB, execute 'Read from PLC' for the project
through the GX Works3 Ver. 1.032J or earlier ones, and add a label to the structure.
The following problem found in FBD/LD editor or SFC editor has been solved.
651 1.047Z - A confirmation message to save project might not be shown when GX Works3 was ended while editing a program.
6/31
Device Test with Execution Condition function of ladder program has been supported for the following modules.
Support new
640 1.047Z
modules
- RnCPU (R00CPU, R01CPU, R02CPU, R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU)
- CC-Link IE built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU)
Following functions have been supported fro FX5CPU.
Support new - User web pages of Web server function
639 1.047Z
modules - 128k steps extension of program capacity
- Options setting for Online Program Change (Divide to write a Program and Program Restore Information)
<Important>The following problem found in RnCPU (redundant mode) or RnPSFCPU has been solved.
Tracking for the specific data was stopped when a power of the standby system was turned OFF/ON after any of the
638 1.046Y - operations shown below.
- 'File batch online change' without writing the program restore information.
- 'File batch online change' for the program in which global labels or FBs are not included.
<Important>The following problem found in label editor of ladder program has been solved.
An execution program was not correctly created after setting the same instance name as other FB to an FB, and
changing it.
637 1.046Y -
If the problem described above occurs, take the following procedure.
With the corresponding FB on the ladder editor selected, press F2, change the instance name to an other name and
change it again.
<Important>The following problem found in importing other format data to Simple Motion module setting function has
been solved.
636 1.046Y - When importing parameters of QD74MH, parameters for the number of pulses per rotation and the movement
amount per rotation were replaced each other.
Function related to RnCPU (redundant mode) or RnPSFCPU has been improved so that Auto Memory Copy Setting
635 1.046Y - is not executed when writing a program file to which a title has been set and turning power of standby system
ON/OFF.
The following problem found in Reflect to System Label Database function has been solved.
- Unable to register when reflecting labels of structure types to system label database.
634 1.046Y -
- MELSOFT Navigator showed 'Editing System Label' even after completing reflecting system labels.
Following problems found in 'Rebuild All' -> 'Write to PLC' have been solved.
- In some cases, a CPU error (3205) might occur when writing data to PLC after deleting FB instance and converting
while 'High-speed' has been set for 'Convert, Online Program Change Target Setting' in Options.
- In some cases, a CPU error (3140) might occur when writing data to PLC after deleting subroutine type FB (with the
630 1.045X - EN/ENO) from a program, executing 'Rebuild All' (Retain), and adding subroutine type FB (with the EN/ENO) again
and converting.
- A CPU error (3C30) occurred when writing data to PLC after editing statement for the function including inline
structured text (created in ladder language) and converting.
Following problems found in 'Read from PLC' have been solved.
- In some cases, a conversion error (0x1212105B) might occur when executing 'Rebuild All' after reading a project
including an unused FB using structure type label.
629 1.045X - - In some cases, a message might be shown saying that the data in PLC has been corrupted when reading data from
PLC after communication error was occurred in executing 'Online Program Change', and executing 'Online Program
Change' again.
7/31
Following problems found in 'Online Program Change' have been solved.
- In some cases, an error message might be shown when executing 'Online Program Change' after getting an
communication error while 'Writing execution program to PLC' has been shown.
- In some cases, a conversion error (0x12011090) might occur while 'Yes' has been set for the 'Save project after
conversion' in Options.
627 1.045X - - In some cases, a project might be saved even if canceling 'Online Program Change' or getting error during the
process while 'Yes' has been set for the 'Save project after conversion' in Options.
- In some cases, unable to execute 'Online Program Change' when using structure type label after deleting a
structure type label used in a program and confirming the structure type label is unused.
- In some cases, a communication error message (ES:010a4080) might be shown when executing 'Online Program
Change' after reading a program including FB from PLC and editing the program.
Following problems found in converting ladder program have been solved.
- In some cases, a conversion error (0x11031F01) might occur when editing ladder and converting it while contacts
and instructions have not been correctly shown after changing the 'Display Connection of Ladder Diagram' in Options
to reduce the number of display contacts.
- In some cases, a conversion error (0x110E19E2) might occur when converting after setting a member of structure
626 1.045X -
array was for an argument that specifies array such as ESTR instructions and others.
- In some cases, a conversion error (0x11031F03) might occur when converting after changing a FB instance through
'Edit FB Instance' that has been set to global label.
- In some cases, the behavior of GX Works3 might be unstable when executing File batch online change after
converting a ladder including '?' device that was shown when an argument of instruction was omitted.
Following problems found in 'Read from PLC' have been solved.
- As for a project including a program using structure label and a program not using structure label, structure type
also might be read when reading a program that did not use structure type label.
- In some cases, program within a inline structured text might not be found/replaced after reading a program including
inline structured text.
- In some cases, an unconverted FB/FUN might be in converted status when editing unused FB/FUN (unconverted
status) after deleting FB/FUN from a program, and reading from PLC after 'Online Program Change'.
625 1.045X -
- When setting a FB to use in a program to global label and not writing to PLC, and reading an other program
including global label, FB might be deleted from global label however the programs status would not be in an
unconverted status.
- In some cases, system behavior might be unstable after a program in which FB that has been created on the
Navigation window by copying was written to PLC although the FB was not used in the program, and read it from
PLC to show FB program body.
8/31
Following problems found in label editor have been solved.
- Check error was not returned even when a label with whose name was a combination of following that is not usable
one for label name and a value was used.
"G", "HG", "RX", "RY", "RWr", "RWw", "ZZ"
621 1.045X - - The reservation status of system label remained to be released when a label name of alias source got system label
was changed.
- In some cases, memory usage capacity might be increased when registering or editing labels from program editor
for Local Label Setting /Global Label Setting in which a large number of defined labels were included.
The following problem found in structure editor has been solved.
620 1.045X - - In some cases, edit content might not be updated if Undo/Redo was executed after editing data.
618 1.045X -
The following problem found in R00CPU model has been solved.
IP filter setting of Ethernet module parameter never show No.5 onwards.
Following problems found in Navigation Window have been solved.
- In some cases, system behavior might be unstable when executing converting after copying structure data between
617 1.045X - projects and getting a circular reference.
- In some cases, memory usage rate might increase when moving FB to other FB file.
Following problems found in a User Library of Element Selection Window have been solved.
- Data type and class setting of alias was deleted if a global label that has been registered to a global label setting of
616 1.045X - other alias source was imported.
- Two user libraries with different case sensitivity were registered when a user library with same file path but different
case sensitivity was registered.
Following problems found in 'Open Other Format File' function have been solved.
- In some cases, system behavior might be unstable when opening a GX Works2 project including FB/FUN.
613 1.045X - - In some cases, a label of tag FB name might not be automatically tracked at where the FB was used in the program
when the tag name was changed through Tag FB Setting and applied immediately after opening a PX Developer
format project.
9/31
Following problems found in Intelligent Function Module monitor have been solved.
- In some cases, system behavior might be unstable when monitoring particular modules(*1).
608 1.045X - - In some cases, display or update of present value might not correctly work when monitoring particular modules(*2).
*1 QJ71FL71(-T -B5)(-F01), QJ71FL71-B2(-F01), QJ71AS92, QJ71DN91
*2 Q62DA(N), QE81WH, QE81WH4W, QE83WH4W, QE84WH
Following modules have been supported for CC-Link IE Field Network Basic.
NZ2MF2S1-32D / NZ2MF2S1-32T / NZ2MF2S1-32TE1 /
NZ2MF2S1-32DT / NZ2MF2S1-32DTE1 /
VS70M-600-E / VS70M-600-ER /
VS70M-800-E / VS70M-800-ER /
Support new VS70M-802-E / VS70M-802-ER /
595 1.045X
modules
VS80M-100-E /
VS80M-200-E / VS80M-200-ER /
VS80M-400-E / VS80M-400-ER /
VS80M-202-E / VS80M-202-ER /
VS80M-402-E / VS80M-402-ER / VS80M-402-D
594 1.045X
Support new Battery-less option cassette (NZ1BLC) has been supported for RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and
modules R120CPU) and CC-Link IE Built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU).
593 1.045X
Support new Online (Asynchronous Mode) function has been supported for High speed data logger module (RD81DL96) and MES
modules interface module (RD81MES96).
Following functions have been supported for RnCPU (R00CPU, R01CPU, R02CPU, R04CPU, R08CPU, R16CPU,
R32CPU, and R120CPU) and CC-Link IE built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and
R120ENCPU).
- Web server function
Support new - Simple PLC Communication function
592 1.045X
modules
- Online Program Change for SFC Active Block
- Target data of Data Logging function/local device with conditions specified and label specification
- Target data of Realtime monitor function/local device with conditions specified and label specification
- Backup/restore of CC-Link master module for iQ Sensor Solution
Support new SIL2 mode has been supported for MELSEC iQ-R channel isolated analog-digital converter module (R60AD8-G).
591 1.045X
modules
Support new SIL2 mode has been supported for MELSEC iQ-R channel isolated digital-analog converter module (R60DA8-G).
590 1.045X
modules
589 1.045X
Support new Register/Cancel Forced Input/Output function has been supported for RnPCPU (R08PCPU, R16PCPU, R32PCPU,
modules and R120PCPU).
10/31
Following functions have been supported for a redundant mode of RnPCPU (R08PCPU, R16PCPU, R32PCPU, and
Support new
R120PCPU).
588 1.045X - Online Program Change of a program restore information in the background.
modules
- Online Program Change that does not write a program restore information.
Following functions have been supported for RnSFCPU (R08SFCPU, R16SFCPU, R32SFCPU, and R120SFCPU).
587 1.045X
Support new - Write to PLC that does not write a program restore information.
modules - Online Program Change that does not write a program restore information.
586 1.045X Add new function Displaying error history of the selected station from diagnostics window has been supported for CC-Link IE Field
Following functions have been supported for ladder program.
- Enter comment in Undefined Label Registration window before registering labels.
585 1.045X Add new function - Change the background color of FB and application instruction
- Specify the number of device comment rows and device label name wrapping in printing
Following functions have been supported for Open GX Works2 Format Project.
- Read the parameter of QX70, QX71, and QX72
579 1.045X Add new function - Read the parameter of QJ71GP21S-SX
- Read the Device/Label Automatic-Assign Setting
Connections via QCPUs shown below have been supported for Specify Connection Destination function.
- PC side I/F: USB and Ethernet Board
Improve - PLC side I/F: CPU Module (QCPU)
576 1.045X
operability - Network Communication Route: Other Station (Single Network)
*: Supported route: CC-IE Control, CC-IE Field, Ethernet
573 1.045X
Improve Function related to ST editor, FBD/LD editor, and Watch window has been improved so that device type specifier can
operability be added for the index-modified device.
572 1.045X
Improve Function related to ladder editor, FBD/LD editor, and SFC diagram editor has been improved so that Device/Buffer
operability Memory Batch Monitor can be executed from right-click menu on the editor.
Function related to ST editor (including inline structured text) has been improved so that the matching brackets are
Improve
571 1.045X highlighted.
operability
11/31
570 1.045X
Improve Function related to label editor has been improved so that the number of display windows can be fixed through the
operability setting in Options.
Functions related to Verify Result display have been improved as follows.
Improve
569 1.045X - Display 'No mismatch' when the verification result of Parameter, Device Comment, and Device Memory are
operability
matched
Improve Candidate Display Setting for labels has been supported for Find, Replace, and Watch window.
568 1.045X
operability
Improve Find by partial match with FBs or structure members specified has been supported for Find and Replace function.
567 1.045X
operability
Jumping function by Find or Cross Reference has been improved so that enabling getting back to the position before
Improve
566 1.045X jump by tracing back the jump history.
operability
563 1.045X
Improve Find/Replace within the specified range has been supported for a Device Comment editor.
operability
Flexible High-Speed I/O Control Module Configuration Tool' ([Tool] -> [Module Tool List]) has been improved so that
562 1.045X
Improve the displayed contents in each block of Hardware logic outline window and Multi function counter block detail window
operability can be displayed in a language matched with display language.
Module configuration diagram has been improved so that station Nos. for network modules that were controlled by
Improve
560 1.045X other PLC.
operability
Registering library function has been improved so that is enabled even when an Element Selection window is not
Improve
559 1.045X displayed.
operability
Writing function for the following modules has been improved so that writing is skipped for unchanged files to reduce
the required time to write.
Improve
RnCPU (R00CPU, R01CPU, R02CPU, R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU)
557 1.045X RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU)
performance
RnSFCPU (R08SFCPU, R16SFCPU, R32SFCPU, and R120SFCPU)
556 1.045X Support new OS Windows 10 IoT Enterprise has been supported.
555 1.045X Notice CSP+ can be installed from the installer of GX Works3. (CSP+ once was included in DVD.)
Open Other Format File' function has been improved so that reading program can be enabled if the target program included
Improve instructions whose argument can be omitted(*).
554 1.044W * D(P).DDRD, D(P).DDWR, JP.READ, JP.SREAD, JP.WRITE, JP.SWRITE, GP.READ, GP.SREAD, GP.WRITE, GP.SWRITE,
operability
J.ZNRD, J.ZNWR, JP.ZNWR, JP.ZNRD
<Important>The following problems found in Convert/Rebuild All have been solved.
- In some cases, program might not correctly work if the program in which rising/falling instruction was used for subroutine type FB
was converted after multiple FB instances were set to global labels and rising/falling instruction was added after Rebuild All
553 1.044W - (reassignment).
- In some cases, structured data type were not correctly transferred in a program whose global labels of structured data type were
transferred to local labels when a FB instance was set to global label for subroutine type FB.
The following problem found in installing (including updating) Version 1.040S or later one of GX Works3 has been solved.
552 1.044W - In some cases, an error message saying 'required files are not found' might be shown while registering profile and failed to install.
12/31
The following problems found in 'Online Program Change' or 'Rebuild All' -> 'Write to PLC' have been solved.
- A CPU error (2820) occurs when specific instructions (HOURM, DHOURM, PID, SORTL, and DSORTL) were used for subroutine
type FBs.
- In some cases, an CPU error might occur in the programs calling subroutine type FB using macro type FB shown below.
551 1.044W -
- A CPU error (2820) occurs when FB instance was set to the type (local/global) different from the caller.
- A CPU error (3100) occurs when 'Optimize the Number of Steps' was set in Options.
- In some cases, a CPU error (3380) might occur when a note was used for an output of the structure type (manually assigned) of
subroutine type FB.
The following problem found in 'Read from PLC' has been solved.
- In some cases, a memory shortage error might occur in reading module parameters of MELSECNET/H module(*1).
*1: QJ71BR11, QJ71LP21(-25 S-25 G GE), QJ71NT11B
550 1.044W - - In some cases, default module parameters of Port 2 of information module(*2), CC-Link IE built-in CPU module(*3) which has
been written to PLC might not be correctly read to a project if they were read again after editing parameters in the project.
*2: RJ71EN71(E+E), RJ71EN71(E+CCIEC), RJ71EN71(E+CCIEF)
*3: RnENCPU(_RJ71EN71(E+IEC), _RJ71EN71(E+IEF))
The following problem found in Simulation function has been solved.
549 1.044W - In some cases, a CPU error (2440) might occur when the Simulation function was executed for the project under the multiple CPU
configuration using RQ extension base.
The following problem found in FBD/LD, SFC editor has been solved.
545 1.044W - A minus sign was deleted when an constant value greater than -1.0 and smaller than 0 was entered.
- To update GX Works3;
->Install the update version of 1.043v or later ones.
The following problem has been solved.
542 1.042U - In some cases, a CPU error (3302) might occur when a program called from subroutine type FB in which a pointer type label was used for
macro type FB was written to PLC.
The following problem found in 'Read from PLC' ha been solved.
541 1.042U - - In some cases, read global label might be disappeared in safety project.
- In some cases, FB/FUN program might be disappeared after reading FB/FUN in which two or more inline structured text was included.
- In some cases, parameters of slave station might be deleted for the CC-Link IE Field Network Module.
The following problem found in 'Write to PLC' has been solved.
540 1.042U -
In some cases, insufficient memory error might occur when a label initial value file was written.
The following problem found in Convert/Rebuild All has been solved.
- In some cases, conversion error (0x1201106F) might occur when 'Update Library POU' was executed for a user library to which FB/FUN was
539 1.042U - registered.
- In some cases, conversion error (0x12011068) might occur when a data name of function block was changed.
- In some cases, program might not correctly work because a structured data type manually assigned to global label was not substituted for a
nested FB with two or more hierarchies
The following problem found in ladder editor using floating window has been solved.
538 1.042U -
In some cases, the operation of GX Works3 might be unstable when the window is activated during converting.
The following problem found in label editor has been solved.
537 1.042U -
If a row for which 'Access from External Device' of Global Label Setting was checked was copied and pasted, it was unchecked.
The following problem has been solved.
536 1.042U -
In some cases, paper settings might not be correctly applied for a specific printer driver.
The following problem found in Simulation function has been solved.
535 1.042U - In some cases, CPU error (2820) might occur when bit device digit was specified and Multiple CPU High Speed Transmission Area was used
for the operand of BMOV instruction.
The following problem found in redundant system has been solved.
534 1.042U -
Event Notification of instrumentation function has not been sent by control system after executing Switch System function.
The following problem found in MELSOFT Navigator has been solved.
533 1.042U -
Processing did not complete correctly after reflecting parameters of data to which R12CCPU-V has been set.
The following problem found in ladder editor has been solved.
533 1.042U -
Wrapped display might be incorrect when inserting a column at the right of right most cell for a row including parallel circuit.
532 1.040S Notice Compatible function for High DPI which was supported version1703 and after ones of Windows 10 has been supported.
Improve Performance of Open function has been improved.
531 1.040S
performance
Improve Display efficiency has been improved when 'Parameter + Program' or 'Select All' button was pressed in 'Write to PLC' window.
530 1.040S
performance
13/31
Improve Performance of 'Online Program Change' has been improved in editing subroutine type FB/FUN.
529 1.040S
performance
Improve Batch install including GX Developer has been enabled for Windows 10.
528 1.040S
operability
Following functions have been supported for Navigation window.
- Reduce the number of hierarchies of module parameter
Improve - Start module tool
527 1.040S
operability - Filter display items
- Change background color and font color
- Display warning message in moving data
Improve Function related to Module Configuration Diagram has been improved so that module parameters of multiple port can be opened.
526 1.040S
operability
Improve Function related Element Selection window has been improved so that library POU can be updated to project in a batch.
525 1.040S
operability
Improve I/O assignment setting of system parameter has been improved so that 'Do not Synchronize' was set for synchronous target module setting for
524 1.040S
operability a CPU module which was set as 'Empty'.
Following functions have been supported for ladder editor.
- In converting ladder including specific instruction (INV, MEP, MEF, EGP, and EGF), return an conversion error if the ladder pattern was not
appropriate as instruction specification
- Save the display position of ladder diagram in saving project data to restore the position in opening it
Improve - When the cursor position is within nesting of master control, the nesting No. is displayed in window title to monitor the conductive status
523 1.040S
operability - Edit line statement displayed in Navigation window
- Display label comment of structure member in comment input window
- In ladder diagram display including FB/FUN, ladder is displayed highlighted when input/output ladder of FB/FUN is not displayed after changing
number of display contacts through Options
FBD/LD editor has been improved so that candidate can be displayed for pointer type label in edit box after selecting jump label element and
Improve
522 1.040S pressing F2 key.
operability
Following functions have been supported for device comment editor.
Improve
521 1.040S - Horizontally split
operability
- Device comment of word device with bit specification can be included for the target to delete unused device comment
Improve Cross reference function has been improved o so that assigned label of alias source are displayed in device display field for alias label.
520 1.040S
operability
Improve Find/Replace function has been improved so that the Find/Replace target object can be searched based on the display order in Navigation
519 1.040S
operability window.
Improve Online Program Change function has been improved so that users are able to select whether to write or not to write the program through Online
518 1.040S
operability Data Operation Window when Online Program Change was executed while the program has been converted.
Improve Operability and visibility have been improved for Watch window.
517 1.040S
operability
Improve Function related to CC-Link IE Field Basic diagnostics has been improved so that users are able to check errors and corrective actions of slave
516 1.040S
operability station.
Following functions have been supported for Print function.
Improve
515 1.040S - Skip the parameters of unset items
operability
- Switching Color and Font setting between in printing and in displaying editor
Following functions have been supported for GX Works3 Q/L/FX series compatible mode.
514 1.040S Add new function - Open the Q/L/FXCPU project
- Read from the Q/L/FXCPU project
- Automatic start of diagnostics function of Q/LCPU
The following function has ben supported for CC-Link IE Field Network.
513 1.040S Add new function
Head module setting can be imported through Safety Communication Setting for Safety Communication Function (SIL2).
Following functions have been supported for ladder program.
- Import/Export function of CSV file for labels
- Enable to set whether to output step No. or not in exporting text file
512 1.040S Add new function - Export CSV file/HTML file/text file concurrently
- Specifying print range
- Print by page break in units of ladder block
- Using assignment devices for label input
Following functions have been supported for SFC and FBD/LD program.
511 1.040S Add new function - Change editor background color or element color
- Set color for each comment element
510 1.040S Add new function Copy device comment in copying elements option has been supported for copy function of SFC editor.
509 1.040S Add new function Displaying page break has been supported for FBD/LD editor.
Following functions have been supported for AnyWireASLINK and CC-Link IE Field.
508 1.040S Add new function - iQ Sensor Solution Compliant Backup/Restore Function
- Sensor/Device Monitor
Following functions have been supported for Simulation function.
507 1.040S Add new function - System simulation which simulates Cyclic Communication
- Save/restore simulation environment (system configuration, data written to simulator)
506 1.040S Add new function Automatic conversion of instruction of ST program (including inline structured text) has been supported for the Open GX Works2 Format
505 1.040S Add new function Reading project parameter and FB property initial value has been supported for Open PX Developer Format Project.
504 1.040S Add new function Watch function and docking/floating function has been supported for 'Flexible High-speed I/O Control Module Setting Tool' ([Tool] -> [Module
503 1.040S Add new function Interchange data function between electrical CAD and GX Works3 Project via MELSOFT Navigator has been supported.
502 1.040S Add new function Offline monitor of FX5CPU has been improved so that users are able to monitor logging data value shown by GX LogViewer in program editor.
Reading data shown below has been supported for Open GX Works2 Format Project function of FX5CPU.
501 1.040S Add new function - FX3G /3GC project
- CC-Link setting of network parameter
Following modules have been supported for MELSEC iQ-R series.
Support new - Programmable Controller CPU (R00CPU, R01CPU, and R02CPU)
500 1.040S - SIL2 Process CPU (R08PSFCPU, R16PSFCPU, R32PSFCPU, and R120PSFCPU)
modules
- SIL2 function module (R6PSFM)
- SIL2 mode of Input Module with diagnostics function (RX40NC6B) and Output Module with diagnostics function (RY40PT5B)
Following modules have been supported for MELSEC iQ-F series.
Support new
499 1.040S - Analog Input Module (FX5-4AD)
modules
- Analog Output Module (FX5-4DA)
Support new Following modules have been supported for CC-Link IE Field Network.
498 1.040S
modules - Block Type I/O Module (NZ2GFCE3N-32D, NZ2GFCE3N-32T, and NZ2GFCE3N-32DT)
Support new The following module has been supported for MELSEC Q series.
497 1.040S
modules - MELSEC-Q series MES Interface Module (QJ71MES96N)
RnCPU(R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU) and RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and
Support new R120ENCPU) and RnPCPU (R08PCPU, R16PCPU, R32PCPU, and R120PCPU) have supported for the following functions.
496 1.040S
modules - Setting whether to write/not to write program restore information
- File batch online change of FB program and global label
Support new Normal mode (high speed: 1μs/CH) and High speed continuous logging function have been supported for High Speed Analog-Digital Converter
495 1.040S
modules Module (R60ADH4).
Support new Referring detailed information of DB buffering of MES Interface Module (RD81MES96) has been supported for Intelligent Function Module.
494 1.040S
modules
14/31
Following functions have been supported for FX5CPU.
- Realtime Monitor Function
Support new - Extended File Register function
493 1.040S
modules - Web Server function
- MODBUS/TCP Communication slave function
- Time setting function (STNP client)
<Important>The following problem has been solved.
492 1.040S -
In some cases, rising/falling instruction to use for subroutine type FB might not work.
<Important>The following problem found in ladder program has been solved.
491 1.040S - - In some cases, instruction might not work when coil equivalent instruction was connected to the bit type output of macro type FB.
- In some cases, rising/falling contact might not correctly work when they were connected to input variable of function in FB for ladder program.
<Important>The following problem found in label editor has been solved.
490 1.040S -
In some cases, device No. might overlap in device automatic input of global label using structured data type.
<Important>The following problem has been solved.
489 1.040S - In some cases, initial value might not be set correctly when a structured data type in which an initial value has been set was used as an array
type label for FB.
The following problem has been solved.
488 1.040S - In some cases, an error message saying 'set parameters back to default' might be shown when a project created by the models other than
RnCPU or RnENCPU was opened in earlier versions of GX Works3.
The following problem found in Open GX Works2 Format Project function has been solved.
487 1.040S - The system read the 'Local Station' of CC-Link setting for Network Parameter as 'Master Station' if CC-Link module in which the start XY has not
been set for I/O Assignment Setting was included in the project.
The following problem found in Print function has been solved.
486 1.040S -
Safety FB/FUB was not displayed while 'Program Block' has been selected for 'Select Print Unit'.
The following problem has been solved.
485 1.040S - In some cases, conversion error (0x12121057) might occur when 'Rebuild All (Retain)' was executed after adding instance of subroutine type FB
(with 2 or more layers) using subroutine type FB.
Following problems found in Convert or Rebuild All function have been solved.
484 1.040S - - In some cases, conversion error (0x1212105B) or CPU error (3100) might occur when Convert or Rebuild All was executed after changing FB
type.
- In some cases, conversion error (0x1212105A) or CPU error (2820) might occur when Convert or Rebuild All was executed after changing FB
Following problems found in 'Online Program Change' function have been solved.
- Unable to monitor a subroutine type FB correctly if it was added to a program, which calls subroutine type FB using macro type FB, and 'Online
483 1.040S - Program Change' was executed.
- Unable to execute 'Online Program Change' when it was executed immediately after opening a project of SFC program which has been saved
in unconverted status
Following problems found in a function related to parameter have been solved.
- In some cases, an overlap error of start I/O might be shown for system parameter even if they were not overlapped.
- Inter-module Synchronization Setting was not correctly set when the station type of CC-Link IE Field Network Module was changed from
482 1.040S - master/local station to sub-master station.
- GX Works3 did not correctly work when a project in which 'set by program' has been set for 'Parameter Setting Method' was opened and its
parameter was set back to default ones.
- In some cases, unable to write 'Hour' and 'Minute' correctly (Application Settings -> Time Setting -> Execution Timing -> Specified Time (Hour,
Minute Day of Week) > Clock Time (Hour Minute)) for Module Parameter of CPU or RJ71EN71
Following problems found in label editor have been solved.
- In some cases, unable to delete blank row.
481 1.040S - - In some cases, label mismatch result might be returned by Verify when data type was edited to other data type by Copy and Paste operation.
- In some cases, result of 'All Find' might not correctly displayed if an blank row was included.
- System label disappeared when project was saved after reading data from PLC
The following problem has been solved.
480 1.040S - In some cases, local labels might not have the priority when 'Yes' has been selected for 'Use the Same Label Name in Global Label and Local
Label' in Options.
Following problems found in ladder editor have been solved.
- In some cases, conversion error (0x11031F01) might occur after pasting ladder to a wrapped ladder.
- In some cases, unable to input instruction for an input argument of FB/FUN under Insert mode.
- In some cases, device comment which has been set to the device with digit specification or index modification might not be displayed correctly.
- In some cases, ladder might not be displayed correctly after changing note type in Statement/Note Batch Edit.
- In some cases, unable to edit ladder after importing ladder program of FB.
- In some cases, GX Works3 might not correctly work if pasting ladder and undo have been repeatedly executed.
- When the 6 argument of JP.SREAD instruction was omitted, an error message saying 'device setting is not correct' was shown and was not
able to use the instruction.
479 1.040S - - In some cases, device comment with bit specification might not be pasted after copy and paste of ladder.
- In some cases, ladder might not be deleted correctly when selecting range while displaying note.
- In some cases, ladder might not be pasted correctly when copy and paste of ladder was executed while displaying note.
- In some cases, Find/Replace might not correctly work if outline display was folded for inline structured text.
- In some cases, instruction/label candidates might not be displayed in inline structured text.
- In some cases, instruction might not be correctly replaced if it is executed so that the number of occupied points of instruction to display was
changed.
- GX Works3 did not work correctly when Replace Character String was executed for a program using general FUN.
- In some cases, ladder might not correctly displayed when the window was scrolled after editing ladder while monitoring, and executing 'Online
Program Change'.
- In some cases, monitored value might not correctly displayed when structured array was defined for the member of structured data type.
The following problem found in ST editor has been solved.
478 1.040S -
In some cases, GX Works3 might not correctly work when using 'Ctrl + mouse wheel' after setting font size as any of 1 to 7 in Color and Font
The following problem found in ST program and FBD/LD program has been solved.
477 1.040S -
A CPU error (3140) occurred when input/output class of local label defined in specific order to create macro type FB, and use it in a program.
The following problem found in SFC editor and FBD/LD editor has been solved.
476 1.040S -
In some cases, edited data including comment batch link might not be saved in a project if it was saved immediately after executing Comment
Following problems found in FBD/LD editor have been solved.
- In some cases, GX Works3 might not correctly work when VAR_OUTPUT of subroutine type FB was inverted and connected to VAR_INPUT
475 1.040S - of FUN.
- Label did not automatically track for digit specified label.
- In some cases GX Works3 might not correctly work when FBD/LD editor and Faceplate was operated respectively after displaying Faceplate
Following problems found in Cross Reference have been solved.
- Label in which structure member has been specified as an array element was not shown.
474 1.040S - - In some cases, 'Valid'/'Invalid' might not be correctly displayed for 'Access from External Device'.
-> Please set the setting again after checking 'Access from External Device' ON and OFF in global label editor.
- In some cases 'Write/Read' the items of Cross Reference result might not correctly displayed for ST editor
The following problem found in Device List has been solved.
473 1.040S -
First argument of MTR instruction was not correctly displayed.
Following problems found in Find/Replace have been solved.
472 1.040S - - Find/Replace was not correctly executed when a double word device has been used for instruction.
- In some cases, device comment might disappear after device/label replacement when the comment was moved for 2 or more program files.
The following problem found in Specify Connection Destination function has been solved.
471 1.040S - Unable to set 'Other Station Setting' when 'Ethernet Board Communication GOT Connection' was selected from 'Connection Channel List' while
'Serial Port GOT Connection' was selected.
15/31
Following problems found in 'Writ to PLC' function have been solved.
470 1.040S - - In some cases, a CPU error (2820) might occur when a program including FB definition name with same name but different in cases was
written to PLC.
- In some cases, progress display might not reach 100% in writing device memory.
Following problems found in 'Read from PLC' have been solved.
- In some cases, local labels might disappear when reading from PLC is executed after Verify with PLC and project verification.
469 1.040S - - Label comment of local label were read when only global label were read.
- In some cases, program might not be read correctly when a program using FB from SD Memory Card.
16/31
The following problem found in ladder editor has been solved.
440 1.036N - In some cases, ladder might be incorrect if a column was inserted to wrapping ladder.
The following problem found in Label Candidacy Display of ST editor has been solved.
438 1.036N - In some cases, a local label of FB which was changed after Rebuild All might not be correctly shown.
The following problem found in CPU Parameter setting window has been solved.
437 1.036N - Incorrect message was shown if an invalid character was entered to the file name of file register setting.
The following problem found in 'Verify with PLC' function has been solved.
436 1.036N - Verification result for FB/FUN file was mismatch if an unconverted FB/FUN was included in the verification target.
As for a program file including a falling instruction, function has been improved so that behaviors of falling instructions in scanning immediately
Improve
434 1.036N after 'File batch online change' and 'Online Program Change' could be the same.
performance
Following modules have been supported for MELSEC iQ-F series.
- CPU Module (FX5UC-32MT/DS-TS, FX5UC-32MT/DSS-TS)
- Input Module (FX5-C32EX/DS-TS)
- Output Module (FX5-C32EYT/D-TS, FX5-C32EYT/DSS-TS)
Support new - Input/Output Module (FX5-C32ET/DS-TS, FX5-C32ET/DSS-TS)
433 1.035M
modules - ASLINK Master Module (FX5-ASL-M)
- CC-Link Master/Intelligent Device Module (FX5-CCL-MS)
- Positioning Module (FX5-20PG-P)
- Temperature Control Module (FX5-4LC)
Support new Multiple Input Module (FX5 8AD)
The following modules have been supported for CC-Link IE Field Network.
432 1.035M
modules - Block Type I/O Module (NZ2GF2B2-16A, NZ2GF2B2-16R, NZ2GF2B2-16S, NZ2GF2S2-16A, NZ2GF2S2-16R, and NZ2GF2S2-16S)
Support new The following modules have been supported for CC-Link IE Field Network Basic.
431 1.035M
modules - Block Type I/O Module (NZ2MFB1-32D, NZ2MFB1-32T, NZ2MFB1-32TE1, NZ2MFB1-32DT, NZ2MFB1-32DTE1, NZ2MFB2-16A, and
Following functions have been supported for RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU).
Support new - Online Program Change for SFC Non-Active Block
430 1.035M - Number of connecting stations extension (from 16 to 64 stations), Group No. setting for CC-Link IE Field Network Basic
modules
- Access to CPU module built-in data base from external device
- Enabling 'Use MC/MCR in EN Control' which is a unique option in creating subroutine type FB
Following functions have been supported for RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU).
Support new - Online Program Change for SFC Non-Active Block
429 1.035M - Number of connecting stations extension (from 16 to 64 stations), Group No. setting for CC-Link IE Field Network Basic
modules
- Access to CPU module built-in data base from external device
- Enabling 'Use MC/MCR in EN Control' which is a unique option in creating subroutine type FB
Support new Writing a program restore information in background has been supported for the process mode of RnPCPU (R08PCPU, R16PCPU, R32PCPU,
428 1.035M
modules and R120PCPU).
Following functions have been supported for Positioning Modules (RD75D2, RD75D4, RD75P2, and RD75P4).
Support new - Offline Simulation
427 1.035M - Automatic Command Speed Calculation
modules
- Automatic Sub Arc Calculation
- OPR method (double as a limit switch)
An option has been added to select whether to save the project automatically after Convert/Write to PLC/Online Program Change/Change TC
426 1.035M Add new function
Setting Value.
Following functions have been supported for program editor.
425 1.035M Add new function - Display device comment setting
- Display user created help from FB/FUN
- In registering Watch/Device Batch Replace after range selection, the same device/label is not registered
424 1.035M Add new function Export function of text file has been supported for ladder program.
Following functions have been supported for Verify function.
423 1.035M Add new function - Verify module parameter of Intelligent Function Module
- Verify module extended parameter of Simple Motion Module
422 1.035M Add new function CC-Link IE Field Diagnostics and CC-Link IE Control Diagnostics have been supported so that they can be used when other station is
Simulation function has been supported for the following functions.
- Forced ON/OFF of external input/output for RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU)
421 1.035M Add new function - Multiple CPU system configuration between RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU) and Motion
CPU (R16MTCPU, R32MTCPU, and R64MTCPU)
- Signal flow area expansion of FB for RnPCPU (R08PCPU, R16PCPU, R32PCPU, and R120PCPU)
- Interaction with the simulation function of RD77GF32
420 1.035M Add new function Open GX Works2 format project function has been improved so that parameters of QY22 can be imported.
419 1.035M Add new function Continuous logging function has been supported for 'Flexible High-Speed I/O Control Module Setting Tool' ([Tool] -> [Module Tool List]).
Following functions have been supported for FX5CPU.
- Memory Dump
- Change TC Setting Value
418 1.035M Add new function - Offline Monitor
- Parallel Link
- IP Filter
- FTP Server
Verification of extension adapter
Simulation function of Simple Motion Module has been supported for FX5CPU.
417 1.035M Add new function
Interaction with simulation function of FX5CPU has also been supported.
416 1.035M Add new function CPU access via CC-Link IE Field Network has been supported for GOT transparent function of FX5CPU.
415 1.035M Add new function An option to reduce the number of program steps has been added for FX5CPU.
414 1.035M Add new function Online Program Change' has been supported for a project in which only one program file has been included as 'No Execution Type'.
Functions for Find/Replace have been improved as follows.
Improve - An option has been added to find DX/DY in batches when X/Y is the target
413 1.035M
operability - As for device replacement, moving comments other than target while the option to move device comment has been enabled
17/31
Following functions have been supported for ladder editor.
- Change column width while multiple columns are selected
- Leave horizontal line after deleting instruction under Insert mode
Improve - Paste ladder to the position, where vertical line could not be pasted such as the one before a statement, with an appropriate correction for the
412 1.035M vertical line
operability
- Cancel the device editing operation by [F2] key, with [ESC] key
- Select and copy the range of Input/Output of FB
- Copy a ladder program including labels from e-manual
Set display magnification in batches
Following functions have been supported for FBD/LD editor.
Improve
411 1.035M - Switch enable/disable Element Auto-connect
operability
- Print based on the number of wrapping ladders
Improve FBD/LD, SFC editor has been improved so that display order of comment elements can be changed.
410 1.035M
operability
Following functions have been supported for CC-Link IE Field Network setting.
Improve - Save the parameters of slave station in the project
409 1.035M
operability - Set safety communication beforehand under offline environment without module machine
Improve Realtime Monitor function (GX LogViewer) and CPU Module Logging Configuration Tool have been improved so that they could be started from
408 1.035M
operability GX Works3.
Improve Device List function of FX5CPU has been improved so that devices which were used in CPU built-in function could be detected.
407 1.035M
operability
Improve Performance related to copy or paste data of POU of FB or Global Label have been improved.
406 1.035M
performance
Improve Performance of Find function have been improved.
405 1.035M
performance
Improve 'Rebuild All' performance and memory usage rate have been improved.
404 1.035M
performance
'Write to PLC' performance have been improved for the following files.
Improve - Global Label Initial Value
403 1.035M
performance - Common Device Comment
- Each Program Device Comment
Improve 'Read from PLC' performance while Navigation window is opened has been improved.
402 1.035M
performance
Improve Monitor display performance in starting monitoring and after scrolling has been improved for ladder editor.
401 1.035M
performance
Following editing performance have been improved for label editor.
Improve - Select range and delete the assignment (device/label) columns
400 1.035M
performance - Delete local labels of FB
- Edit global labels in the case that mass labels have been registered to Watch
The following problem found in a project of GX Works3 Ver.1.019V or earlier one has been solved.
399 1.035M -
In some cases, some part of ladder program might not be correctly restored when 'Read from PLC' was executed after 'Online Program
The following problem found in a program created with ladder language has been solved.
398 1.035M - Series connection/parallel connection program including 'LD SM400' and dynamic array labels might not correctly work when 'Yes' was selected
for 'Optimize the Number of Steps' in Options.
18/31
The following problems found in rising/falling instructions have been solved.
In some cases:
'- Rising/falling instruction which was used in macro type FB might not correctly work when the same macro type FB was used multiple times in
subroutine type FB.
- Rising/falling instruction which was used in subroutine type FB might not correctly work when subroutine type FB including rising/falling
instruction was changed to other subroutine type FB.
380 1.033K - - A conversion error (0x12121057) might occur when Rebuild All (label assignment retaining) was executed for a project using subroutine type
FB including rising/falling instruction.
- A conversion error (0x12121057) might occur when subroutine type FB (ladder program) including rising/falling instruction was edited and
'Online Program Change' was executed after Read from PLC operation.
- Rising/falling instruction used in safety subroutine type FB might not correctly work when an safety subroutine type FB instance was added to a
program in which the same safety type subroutine FB was used multiple times.
The following problem has been solved.
379 1.033K - In some cases, a conversion error (0x12121057) might not occur even the reserved space of Signal Flow area was insufficient in a program
using a nested subroutine type FB.
The following problem has been solved.
378 1.033K - After a conversion error (0x12121044) for a nested subroutine type FB, the operation of GX Works3 might be unstable when 'Convert' was
executed after deleting local labels and setting label initial value.
The following problem has been solved.
377 1.033K -
In some cases, conversion error might occur when local device was set as the output argument of macro type FB.
The following problem has been solved.
376 1.033K - After 'Rebuild All' operation, the color of characters in Navigation window which were supposed to be changed white might remain red for a
project whose program using macro type FB was registered as unregistered one.
The following problems found in 'Online Program Change' or 'Rebuild' -> 'Write to PLC' operations.
In some cases:
'- A CPU error (3205) or a communication error message (ES:010a4080) might be shown when 'Online Program Change' was executed for a
program which used its unused FB/FUN.
- A CPU error (3205) or a communication error message (ES:010a4080) might be shown when 'Online Program Change' was executed for a
program after deleting used FB/FUN to make its status unused.
375 1.033K - - A communication error message (ES:010a4080) might be shown when 'Online Program Change' was executed if instance of FB to be
converted was set to global label.
- As for a ST, SFC, or FBD/LD language program, a CPU error (3202) might occur if 'Rebuild All' -> 'Write to PLC' was executed after an 'Online
Program Change' conversion error.
- Memory shortage error might occur when 'Online Program Change' was executed after 'Convert' or 'Rebuild All', closing project, and newly
reading it from PLC.
The following problem found in SFC editor has been solved.
374 1.033K - In some cases, GX Works3 might not correctly work when action/transition was pasted after cutting while 'Yes' was selected for the 'Include
Zoom in Copying' and 'Paste Data with Different Data Name' in Options for SFC Diagram Editor.
The following problem found in ladder program has been solved.
373 1.033K - In some cases, GX Works3 might not correctly work if vertical line was written crossing over rows including MC instruction for a program in
which statement was under double-line symbol (contact for MC instruction).
The following problem has been solved.
372 1.033K - In some cases, a memory shortage error might occur when the order of line statement was changed and opened in Navigation window after
closing floating ladder editor.
The following problem found in ladder editor has been solved.
371 1.033K -
In some cases, it might take a while if a row was inserted to wrapping ladder while the system is running under Write Mode.
The following problem found in ladder editor has been solved.
370 1.033K -
In some cases, mouse might not scroll by lines set through the property of mouse for Windows.
The problem found in ST editor have been solved.
369 1.033K - The following operations might cause .NET Framework errors.
- ST editor was opened while device memory editor or label editor was shown.
- Editing ST program which has too many rows to fit in one screen.
The following problem has been solved.
368 1.033K -
In some cases, memory shortage error might occur when multiple function blocks/functions were pasted to Navigation window.
The following problem found in FX5CPU has been solved.
367 1.033K -
In some cases, an error message might be shown when W device is set as latch in CPU Parameter setting.
The following modules have been supported for MELSEC iQ-R series.
- High Speed Digital-Analog Converter Module (R60DAH)
Support new - AC Input Module (RX28)
366 1.032J
modules - Contact Output Module (RY18R2A)
- Extension Cable (RC100B)
- BACnet Module (RJ71BAC96)
Support new The following modules have been supported for CC-Link IE Field Network.
365 1.032J
modules - Specified low-power radio Bridge Module (NZ2WM-GFBT)
Support new A new function has been supported for RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU) and Motion CPU
364 1.032J
modules (R16MTCPU, R32MTCPU, and R64MTCPU) to configure multiple CPU system.
The following functions have been supported for process control function.
- Process control extended function
363 1.032J Add new function - Tag FB setting
- Docking window (FB Property window)
- Faceplate
- Open PX Developer Format Project
The following functions have been supported for FBD/LD editor.
362 1.032J Add new function - Link Comment
- FBD Network Block List
- Option function to Use Same Display Format for Contact as Device/Label Current Value
The following functions have been supported for Verify function.
361 1.032J Add new function - Detailed verification of program files
- Verify device comment, device memory, or file register with PLC
- Function to hide the matched ladder blocks in verification result window
360 1.032J Add new function Change TC Setting Value function has been supported.
359 1.032J Add new function Sensor/Device Monitor function has been supported.
358 1.032J Add new function Latch function has been supported for Simulation function.
Improve The function related to data list display of Online Data Operation has been improved.
357 1.032J
operability Users are able to set the target items whether to show or hide through Set Favorites setting.
Improve Write to PLC' function has been improved.
356 1.032J
operability If module label has not been used in Refresh setting of Module Parameter, they are not set as write target when global label is selected.
Improve Options to limit the Convert or Rebuild All function has been supported.
355 1.032J
operability
Improve MELSAP-L (Instruction Format) display of SFC editor has been improved so that the monitored value at cursor position is highlighted.
354 1.032J
operability
Improve The function related to Forced Input/Output Registering Window has been improved so that it can be started from Monitor Status bar.
353 1.032J
operability
Improve The function related to the Library of Element Selection window so that data can be added through 'Add to Project' menu.
352 1.032J
operability
19/31
A message prompting user to retry the operation shown under the following conditions has been improved.
Improve
351 1.032J Communication error (disconnection and other errors) or cancelling occurred during 'Online Program Change' under the setting that 'Write in
operability
Background' has been selected for 'Write a Program Restore Information'.
Improve Function has been improved so that an conversion error can be returned if a constant or bit device (X, Y, M, L, SM, F, B, and SB) was set to the
350 1.032J
operability second argument of the dedicated instruction G(P).OFFGAN.
Improve Function related to 'Write to PLC' and 'Online Program Change' has been improved for the case that label initial value had not been used.
349 1.032J
performance
Improve 'Verify with PLC' function has been improved in verifying program files.
348 1.032J
performance
Improve 'Paste Data' function of POU using Module Label or Module FB has been improved.
347 1.032J
performance
Following explanation has been added for the Operating Environment of GX Works3 Installation Instruction.
346 1.032J Notice
'For a project including 20,000 or more labels, a 64-bit operating system with Intel Core i7 processor and 8GB or more memory is
The following problem found in executing 'Rebuild All' -> 'Write to PLC' has been solved.
345 1.032J - In some cases, labels in ladder program might not be correctly displayed for a project in which data of global labels have been repeatedly added
and deleted.
The following problems found in 'Online Program Change' have been solved.
- In some cases, label initial value might not be applied if the value has been set to local label.
- In some cases, label initial value might not be applied if the value of structure type global label has been deleted.
- In some cases, CPU error (3380) might occur if a ladder program including subroutine type FB whose argument was pointer type label has
been edited.
- In some cases, CPU error (4080) might occur if nested FB has been added to SFC program.
344 1.032J - - In some cases, the system might not return an error but conversion operation was interrupted if user has created an unconvertable project
(circular reference of FB).
- In some cases, GX Works3 might not correctly work if user has created an unconvertable project (newly add labels).
- Communication error message (ES:010a4022) was shown and failed to execute Online Program Change if global label a project including
unused FB/FUN files that did not existed in PLC has been edited.
- In some cases, an message prompting user to retry the operation after communication was started again might not be shown even if
communication error (disconnection and other errors) occurred during Online Program Change.
The following CPU errors in executing 'Rebuild All' -> 'Write to PLC' have been solved.
- In some cases, CPU error (3142 or 2820) might occur if 'Yes' was selected for 'Optimize the Number of Steps' in Options for a ladder program
343 1.032J - in which subroutine program call instruction (CALL/ECALL/FCALL/XCALL) was included.
- In some cases, CPU error (3202) might occur for a project including unconverted FBs/FUNs.
- In some cases CPU error (3300) might occur for a project in which a FB including pointer type label has been set to local label
The following problem found in executing 'Rebuild All' -> 'Write to PLC' has been solved.
342 1.032J - In some cases, program might not correctly work if 'Yes' was selected for 'Optimize the Number of Steps' in Options for a project in which
devices have been assigned to bit type array global label with two or more dimensions.
The following problem found in executing 'Rebuild All' -> 'Write to PLC' has been solved.
341 1.032J - In some cases, program might not correctly work if 'Yes' was selected for 'Optimize the Number of Steps' in Options for a FUN in which local
label has been used in Inline Structured Text.
The following problem found in ST program has been solved.
In some cases, program might not correctly work if general FUNs shown below have been included.
340 1.032J - - INT_TO_BITARR(_E)
- DINT_TO_BITARR(_E)
- CPY BITARR( E)
The following problem has been solved.
339 1.032J -
In some cases, label initial value might not correctly work if binary or octal constant has been set to the initial value of global label.
The following problem has been solved.
338 1.032J -
In some cases, program might not correctly work if manually assigned structured data type label has been set to input/output instruction of FUN.
The following problem has been solved.
337 1.032J -
In some cases, a program using multiple module FBs might not be correctly converted if it has been repeatedly converted.
The following problem has been solved.
336 1.032J -
In some cases, data to be converted might not be converted if 'Convert' was executed after updating module labels and adding FUNs.
The following problem has been solved.
335 1.032J - Failed to 'Write to PLC' if a program, that did not show the unconverted status even after changing data name of program block, was written to
PLC without conversion.
The following problem found in ladder program has been solved.
334 1.032J -
In some cases, system might fail to 'Rebuild All' if a dummy device '?' has been set to FB/FUN.
The following problem has been solved.
333 1.032J -
In some cases, GX Works3 might not correctly work if 'Read Mounting Status' has been repeatedly executed.
The following problem found in Redundant PLC (Redundant Mode of R08PCPU, R16PCPU, R32PCPU, or R120PCPU) has been solved.
332 1.032J -
In some cases, operation might fail if only system parameters have been written to PLC for both systems after memory initialization.
The following problem found in History of Element Selection window has been solved.
331 1.032J - In some cases, GX Works3 might not correctly work if drag and drop was executed under the status that the number of histories has exceeded
100 or more.
The following problem has been solved.
330 1.032J -
In some cases, GX Works3 might not correctly work if a project, which was saved while ST editor or SFC editor was opened, was opened.
The following problem found in label editor has been solved.
329 1.032J -
System was unstable if a structure member was successively added.
The following problem has been solved.
328 1.032J -
In some cases, FB might not be correctly monitored if data name of program file or FB file has been changed.
The following problem found in Cross Reference function has been solved.
327 1.032J -
In some cases, Find might not be executed if I/O No. designation device has been specified as Find target.
The following problem found in ladder editor has been solved.
326 1.032J - - In some cases, instance name might not be changed through 'Edit FB Instance' to the one which an Alias has been set to.
- In some cases, an unexpected labels might be shown by label candidacy display.
- In some cases, scroll bar was not displayed for the monitoring window of Inline Structured Text.
The following problem found in Verify function has been solved.
325 1.032J - - If 'No' has been selected for 'Distinguish between Contact and Comparison Instruction Equivalent to Contact' in Options, 'Unable to compare'
message might be shown in project verification result window.
- As for 'Verify with PLC' function for a ladder program including FBs, matched ladder might be shown as unmatched ones.
The following problem found in ST editor has been solved.
324 1.032J -
ST editor window was scrolled up to the top during monitoring if Start Monitoring/Stop Monitoring has been repeatedly executed.
The following problem has been solved.
323 1.032J -
CheckWarning was returned if a program included a general FB between MC and MCR instruction.
The following problem found in FX5CPU has been solved.
322 1.032J -
In some cases, Rising/Falling instruction might not correctly work in subroutine type FB.
The following problem found in Simulator of FX5CPU has been solved.
321 1.032J -
In some cases, a program including functions might not correctly work.
The following problem has been solved.
320 1.031H -
Failed to connect with the GT Simulator3 of GT Designer3 while the simulator of FX5CPU was running.
The following modules have been supported for MELSEC iQ-R series.
Support new - Redundant Power Supply Module (R63RP)
319 1.030G - Triac Output Module (RY20S6)
modules
- Flexible High-Speed I/O Control Module (RD40PD01)
- Simple Motion Module (RD77GF32)
20/31
The following modules have been supported for MELSEC iQ-F series.
Support new - CPU Module (FX5U-64MR/DS, FX5U-64MT/DS, FX5U-64MT/DSS, FX5U-80MR/DS, FX5U-80MT/DS, FX5U-80MT/DSS)
318 1.030G - Input/output Module (FX5-16ER/ES, FX5-16ET/ES, FX5-16ET/ESS)
modules
- Extension Adapter (FX5-4AD-PT-ADP, FX5-4AD-TC-ADP)
- Simple Motion Module (FX5-80SSC-S)
The following modules have been supported for CC-Link IE Field Network.
Support new - Multiple Input Module (NZ2GF2S-60MD4)
317 1.030G
modules - Analog Input Module (NZ2GFCE-60ADI8, NZ2GFCE-60ADV8)
- Analog Output Module (NZ2GFCE-60DAI8, NZ2GFCE-60DAV8)
The following functions have been supported for RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, R120CPU) and RnENCPU (R04ENCPU,
Support new R08ENCPU, R16ENCPU, R32ENCPU, R120ENCPU).
316 1.030G
modules - Forced ON/OFF function of external input output
- CC-Link IE Filed Network Basic Function
The following modules have been supported for AnyWireASLINK Master Module (RJ51AW12AL).
Support new
315 1.030G - AnyWireASLINK Configuration Setting
modules
- Intelligent Function Module Monitor
Support new CPU access via CC-Link IE Field Network has been supported for GOT transparent function.
314 1.030G
modules
The following functions have been supported for Simulation function.
- Label initialization control and redundant function for RnPCPU(R08PCPU, R16PCPU, R32PCPU, R120PCPU)
313 1.030G Add new function - Cooperative simulation with RnMTCPU
- Cooperative simulation with RD77GF
- I/O system setting function of FX5CPU
The following functions have been supported for ladder program.
312 1.030G Add new function - Import/Export of CSV file
- Export to HTML file
311 1.030G Add new function Function to delete unused labels has been supported.
The following functions have been supported for FBD/LD editor.
- Use of assignment device for label input
- Display for wrap text of label name/comment range
310 1.030G Add new function - Display FB/FUN to connect to device or label in Cross Reference
- Display labels and devices simultaneously
- Find/Replace with range specified
- Display 'Undefined Label Registration' for the label including member display ( ) or array display ([])
309 1.030G Add new function An option to disable the editing function by mouse operation has been added for ladder editor.
308 1.030G Add new function Verify project function has been supported for device comment, device memory, and file register.
An option to set locale has been added to convert the program including the character strings whose language is different from the one for the
307 1.030G Add new function
locale setting of Windows.
The following functions have been supported for SFC language.
306 1.030G Add new function - MELSAP-L (Instruction Format) display
- Open a new window by bock start step during SFC Auto-scroll monitoring
The following functions have been supported for FX5CPU.
- Write data to Memory Card/read data from Memory Card
- FTP Server function
- Event history function
305 1.030G Add new function - Logging function
- Auto-detect function of the connected devices for the Ethernet
- Intelligent Function Module monitor function
- Simple setting display of device/label memory area setting
- Verify function of built in function parameter
CC Link IE Field Network Basic Function
Open GX Works2 Format Project' function has been improved so that it can import the following modules' parameters.
QJ71C24N/QJ71C24/QJ71C24N-R2/QJ71C24-R2/
QJ71C24N-R4/
Q68RD3-G/Q68TD-G-H02(H01)/
Q68TD-G-H01/Q68TD-G-H02/
Q64TCRTN/Q64TCRT/Q64TCRTBWN/Q64TCRTBW/
Q64TCTTN/Q64TCTT/Q64TCTTBWN/Q64TCTTBW/
QD77MS2/QD77MS4/QD77MS16/
304 1.030G Add new function
QX10/QX10-TS/QX40/QX40-TS/QX40-S1/
QX40H/QX41/QX41-S1/QX41-S2/QX42/QX42-S1/
QX80/QX80-TS/QX80H/QX81/QX81-S2/QX82/
QX82-S1
QY10/QY10-TS/QY40P/QY40P-TS/QY41H/QY41P/
QY50/
QY80/QY80-TS/QY81P/QY82P/
QH42P/
303 1.030G Add new function Read function of GX Works2 format has been improved so that device assignment of global labels can be held for FXCPU.
Improve Function related to the project without label has been improved so that programs can be individually selected or written to PLC.
302 1.030G
operability
Improve Function related to Offline Monitor has been improved so that the logging data displayed in GX LogViewer can be monitored in program editor.
301 1.030G
operability
Improve Function related to Navigation window has been improved so that statement set as 'Display in Navigation Window' or multiple worksheets can be
300 1.030G
operability displayed even label and FB/FUN were hidden.
Improve Visibility of the monitored value has been improved for the ladder editor displayed at a low magnification.
299 1.030G
operability
Improve Statement editing function of ladder editor has been improved so that editing for END instruction can be enabled.
298 1.030G
operability
Improve As for the function to open system parameter has been improved so that other parameter setting window or module configuration diagram can
297 1.030G
operability be closed.
Improve 'Confirm Memory Size (Offline)' function has been improved so that users are able to select byte or number of steps through 'Display Unit'.
296 1.030G
operability
Improve Installation function has been improved so that GX LogViewer and CPU Module Logging Configuration Tool can be installed.
295 1.030G
operability
Improve Editing performance of the parameter setting window has been improved for Intelligent Function Module.
294 1.030G
performance
Improve 'Copy the Range Including Hidden Bit Specification Information' performance has been improved for the device comment editor.
293 1.030G
performance
The following problem found in 'Online Program Change' has been solved.
'- CPU error (3142) might occur if 'Online Program Change' is executed after editing macro type FB.
292 1.030G - '- CPU error (4080) might occur if adding general FB to the program and executing 'Online Program Change' operation is repeated.
- CPU error might occur if 'Online Program Change' is executed after changing the definition of the structured data type.
- Unable to execute 'Online Program Change' because of an internal information mismatch error if 'Online Program Change' is executed while
'Yes' was selected for the 'Optimize the Number of Steps' in Options for the SFC language program
The following problem has been solved.
291 1.030G -
In some cases, CPU error(3205) might occur in writing project to PLC if the project contained unused FB.
21/31
The following problem has been solved.
290 1.030G - In some cases, structured data type might not be correctly transferred from the program in which structured data type has been set to input
argument/output argument/result value of function.
The following problem found when module label was selected as the refresh target in Refresh setting.
289 1.030G - - Refresh setting might not be correctly read if parameters of Simple Motion Module has been read from PLC.
- Assignment target of module label in R60ADH4 might be overlapped.
The following problem has been solved.
288 1.030G -
In some cases, device assignment of module label was incorrect if module label with the same model name or same module type was added.
The following problem has been solved.
287 1.030G -
In some cases, it might not be able to change module type for the positioning project or the project including a Temperature Control Module.
The following problem found in a ladder program including a Inline Structured Text has been solved.
286 1.030G -
GX Works3 might not correctly work if a Inline Structured Text was deleted while the 'Verify Result' window was displayed.
The following problem found in 'Watch' function has been solved.
285 1.030G -
If a character type label was monitored, data which was out of the data length of the character type was also monitored .
The following problem has been solved.
284 1.030G -
In some cases, 'Device Batch Replace' might fail if 'Copy' was selected for the 'Device Comment' through 'Replace Options'
The following problem found in cooperative simulation function with Simple Motion Module has been solved.
283 1.030G -
GX Works3 did not correctly work if a project whose scan time monitoring time was exceeded its setting time was operated.
The following problem found in 'Write to PLC' function has been solved.
282 1.030G - - It might not be able to select file individually for the project which was newly read from PLC.
- As for the project containing a safety program, it might not be able to write file register to the PLC with initialized status.
The following problem found in FBD/LD editor monitor has been solved.
281 1.030G -
In some cases, the conduction state of the connected line might not be displayed.
The following problem has been solved.
280 1.030G -
As for the 'Input Device Comment' window of ladder editor, '&' can not be displayed in preview window.
The following problem has been solved.
279 1.030G -
In some cases, it might not be able to switch editor mode from write mode to write monitor mode for the ladder program including unconverted
The following problem found in 'Read from PLC' function has been solved.
278 1.030G - - Error might occur in reading data from PLC if a project in which single quarts (') and double quarts (") were used in label comment
simultaneously was read from PLC.
- GX Works3 might not correctly work for a particular project if global label was read.
The following problem has been solved.
277 1.030G -
If the 'Contact Display Width' (Options) was changed while the ladder editor was closed, it was changed to the unexpected width.
The following problem has been solved.
276 1.030G - If [Initialization] was executed from [CPU Memory Operation...] of [Related Functions] in [Online data Operation] ([Online] -> [Verify with PLC]),
the GX Works3 might not correctly work.
The following problem has been solved.
275 1.030G -
Unable to set SNTP Server IP Address If a GX Works2 format project which did not use the SNTP function setting was opened.
The following problem found in a project containing global labels (standard/safety/standard safety shared) has been solved.
274 1.030G -
In some cases, safety/standard safety shared global labels might not be correctly read.
The following problem found in Specify Connection Destination setting has been solved.
273 1.030G -
In some cases, error might occur when Network No. and Station No. was entered in 'PC side I/F Detailed Setting of Ethernet Board'.
The following problem has been solved.
272 1.030G -
In some cases, it might not be printed if pages to print was specified and printing was executed from 'Print Preview' window.
The following problem has been solved.
271 1.030G -
GX works3 did not correctly work if Find was executed after switching hierarchy display of Cross Reference.
The following problem found in SFC diagram editor has been solved.
GX Works3 might not correctly work for the cases shown below.
270 1.030G - - Insert the Selection Branch/Simultaneous Branch.
- Repeat the Zoom In/Zoom Out operation while SFC Auto-scroll monitoring is executed.
- Replace step relays to labels
The following problem has been solved.
269 1.030G -
In some cases, GX Works3 might not correctly work if the split ladder editor was opened during monitoring.
The following problem found in 'Rebuild All' function has been solved.
268 1.030G - GX Works did not correctly work for the cases shown below.
- Rebuild all function for unconvertable project (FB instance is circular reference)
- Rebuild all function after undo operation in label editor
Failing in reading GX Works2 format project for the following projects has been solved.
267 1.030G - - FXCPU project in which device comments were set for a particular buffer memory
- FXCPU project in which statements were set with the maximum number of characters with the use label setting
The following problem has been solved.
266 1.030G -
Device comment 'Error Clear Request' which should be set to Y10 was set to Y0E after reading the sample comment of RD81DL96.
The following problem has been solved.
265 1.030G - In some cases, GX Works3 might not correctly work if other module tool was started after closing the Temperature trace window ([Tool] ->
[Module Tool List]).
The following problem has been solved.
264 1.028E - If Convert of Rebuild All (label assignment retaining) was executed after adding instance of subroutine type FB whose labels were changed, the
subroutine type FB might not work correctly.
The function related to opening the Watch window has been improved.
262 1.028E -
The following problem has been solved.
261 1.028E - In some cases, system might be unstable if the entire global label data of definition source were deleted from the Navigation Window while they
were displayed in Watch.
22/31
Required time to start Monitor function has been reduced for the ladder program of the Safety FB.
255 1.027D -
The following problem found in RnPCPU (R08PCPU, R16PCPU, R32PCPU, and R120PCPU) has been solved.
254 1.027D - In some cases, communication error message might be shown in reading Memory Card.
Required time to complete inputting ladders was reduced if the result of auto-tracking has been shown in Cross Reference of ladder editor.
251 1.027D -
The following problem has been solved.
250 1.027D - In some cases, the ladder editor might not be fitted to the window width even if the 'Fit the editor width to the window width' was executed.
Function has been improved so that the system is able to check whether the display language setting between the System Locale Settings of
249 1.027D - Windows and the GX Works3 is matched in converting because the invalid conversion result might be returned if those two language setting
have not been matched.
The following problem found in SA\X and SA\Y of safety device has been solved.
247 1.027D - Users were not able to input device comment/device memory for device No. 2000 to 2FFF.
The following problem found in communication with multiple CPU modules via CC Link IE Control/Field Board has been solved.
If a communication error occurred at one CPU module, communication speed with other CPU module might be slowed.
246 1.027D -
The following problem found in ST or FBD/LD language program has been solved.
235 1.026C - In some cases, unable to jump to the conversion error point related to instruction or general function/function block from output window.
23/31
Support new Redundant power supply system has been supported for the following modules.
modules - RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU)
229 1.025B - CC-Link IE Built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU)
- RnPCPU(R08PCPU, R16PCPU, R32PCPU, and R120PCPU)
Support new CPU access via following network boards has been supported for Specify Connection Destination function.
modules - CC-Link IE Controller Network Interface Board
228 1.025B - CC-Link Field Network Interface Board
- CC-Link Ver.2 Board
- MELSECNET/H Board
Support new CPU access via CC-Link IE Controller Network has been supported for GOT Transparent function.
227 1.025B
modules
Support new Block type I/O (NZ2GF2B1N1-16D, NZ2GF2B1N1-16T, and NZ2GF2B1N1-16TE)(extension terminal block type: 3 steps) has been supported
226 1.025B modules for CC-Link IE Field Network.
Support new Following modules of MELSEC iQ-F series have been supported.
modules - CPU: FX5U-32MR/DS, FX5U-32MT/DS, and FX5U-32MT/DSS
225 1.025B - I/O: FX5-16ET/ES-H, FX5-16ET/ESS-H, FX5-32ER/DS, FX5-32ET/DS, and FX5-32ET/DSS
- Network: FX5-CCLIEF
Add new function Change module type function from iQ-F series (FX5UCPU) to iQ-R series (R04CPU) has been supported.
224 1.025B
Add new function Simulation function has been supported for FX5CPU.
223 1.025B
Add new function Sample Library has been supported for the Library Pool function of FX5CPU.
222 1.025B
Add new function Function to open the User Library of GX Works2 format has been supported for FX5CPU.
221 1.025B
Add new function Function to display XY assignment information has been supported for the Module Configuration diagram and Navigation window of FX5CPU.
220 1.025B
Add new function Check Syntax function has been supported for FX5CPU.
219 1.025B
Add new function A new function has been added for FX5CPU to display the free space volume of label memory area in output window in completing the
218 1.025B Convert/Online Program Change/Rebuild All.
Add new function Multiple worksheets have been supported for ST, FBD/LD editor.
217 1.025B
Add new function Label Initial Value Reflection Setting function has been supported for RnPCPU (R08PCPU, R16PCPU, R32PCPU, and R120PCPU).
216 1.025B
Add new function Verify function for PLC module parameters has been supported.
215 1.025B
Add new function Auto-registration to Watch window function has been supported for FBD/LD editor.
214 1.025B
Add new function Print function has been improved so that users are able to specify pages to print.
213 1.025B
Add new function Function to detect unused label has been supported.
212 1.025B
Add new function Function to adjust the width of entire editor to the one of window has been supported for ladder editor.
211 1.025B
Add new function Replace function has been improved so that the ladder program can be replaced if it is running under read mode.
210 1.025B
Add new function Function to restore the ladder to the one before editing has been supported for ladder editor.
209 1.025B
Add new function Continuous Paste function of ladder editor has been improved so that comments can be displayed.
208 1.025B
Add new function Grid Display function of ladder editor has been improved so that switching show/hide and setting color can be enabled.
207 1.025B
Add new function Cross Reference function has been improved so that the currently displayed window can be specified as a Find target.
206 1.025B
Add new function Navigation window function has been improved so that Label and FB/FUN items can be hidden.
205 1.025B
Add new function Device Batch Replace function has been improved so that the value which was set in points can be hold if character strings was pasted to the
204 1.025B replace device.
Add new function FBD/LD, SFC editor has been improved so that display color of device/label and comment can be changed.
203 1.025B
Add new function FBD/LD, SFC program has been improved so that warning is displayed if Type Conversion is automatically executed.
202 1.025B
Add new function 'Output Mode upon CPU Error' has been added to the Module Parameter of Analog Module (R60DA4, R60DAI8, R60DAV8, R60DA8-G, and
201 1.025B
R60DA16-G).
Add new function Module Tool (Create Wave Output Data) has been supported for Remote Head Module (RJ72GF15-T2).
200 1.025B
Add new function High-Speed Logging Mode Has been supported for Analog Module (Q64ADH).
199 1.025B
Add new function RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU) and CC-Link IE built-in CPU (R04ENCPU, R08ENCPU, R16ENCPU,
R32ENCPU, and R120ENCPU) have supported for the following functions.
198 1.025B - Backup/Restore Function of CPU Module
- iQ Sensor Solution Compliant Backup/Restore Function
- File Transfer Function (FTP Client)
Improve Operability of editing comment has been improved for Watch and Cross Reference function.
197 1.025B
performance
24/31
Improve Export function of device comment has been improved so that the output file can be sorted by device type.
196 1.025B
performance
Improve Visibility of bit display has been improved for Device/Buffer Memory Batch Monitor and Watch window.
195 1.025B
performance
Improve Function to specify the range to Find/Replace has been supported for ladder editor.
194 1.025B
performance
Improve FBD/LD, SFC editor has been improved so that it can be zoomed in/out against the cursor position.
193 1.025B
performance
Improve Module labels related function has been improved so that it can be easily updated.
192 1.025B
performance
Improve Required time to display Online data operation window has been reduced for the Ethernet direct connection of FX5CPU.
191 1.025B
performance
The following problem found in ST or FBD/LD program has been solved.
190 1.025B - In some cases, system did not correctly work if a structure data type was substituted to other structure data type using MOVE_E(MOVE)
instruction.
The following problem found in ST or FBD/LD program has been solved.
189 1.025B - In some cases, error message after Rebuild All (Reassignment) might not be shown if 'No' was selected for 'Minimize the Temporary Area' in
Options.
188 1.025B - The following problem found in ST program has been solved.
In some cases, assignment statement placed after the DY device in which TRUE has been assigned might not be executed.
The following problem found in Analog Module (R60DA4 (Q Compatible Mode) and R60DAI8 (Q Compatible Mode)) has been solved.
179 1.025B - Disconnection Detection was not correctly displayed in Module Diagnostics window.
The following problem found in Temperature trace function has been solved.
178 1.025B - In some cases, monitor might not be displayed.
The following problem found in I/O Assignment Setting of System Parameter has been solved.
176 1.025B - In some cases, GX Works3 might not correctly work if a general module with no points were included.
The problem found in FX5CPU, where initial values of the following general FBs might not be correctly worked, has been solved.
- TIMER_100_FB_M
170 1.025B - - TIMER_10_FB_M
- TIMER_1_FB_M
25/31
The following problem found in FX5CPU has been solved.
168 1.025B - In some cases, the fifth argument of the monitor value for ADPRW instruction might not be shown.
The following problem found in FBD/LD, SFC editor has been solved.
165 1.023Z - In some cases, a program after editing might not be saved.
The following problem found in Intelligent Function Module has been solved.
164 1.023Z - Unable to enter the hexadecimal number for module parameters.
The following problem found in Write to PLC function has been solved.
163 1.023Z - In some case, it might take several minute to complete writing global label or Online Program Change if 'Access from External Device' has been
checked.
The following problem has been solved.
162 1.023Z - Unable to use GP_SOCRCV instruction in standard program (ST, FBD/LD) of safety CPU.
A new function has been added to display free space volume of label memory area in output window in completing the Rebuild All/Convert/Online
157 1.022Y Add new function Program Change.
A new option has been added so that users are able to select whether to verify ladder diagram or not to show the detailed result from the
156 1.022Y Add new function verification result list.
Function for ladder editor has been improved so that the selected multiple ladders can be deleted at once.
152 1.022Y -
The following problem found in FBD/LD editor has been solved.
151 1.022Y - System did not work correctly in converting if the output of FB element and contact element were connected to variable element and substituted.
26/31
The following modules of MELSEC iQ-R series have been supported.
- Extended Temperature Range Base (R310B-HT and R610B-HT)
- High-Speed Data Logger Module (RD81DL96)
Support new - High-Speed Output Module (RY41NT2H and RY41PT2H)
140 1.020W - High-Speed Analog Module (R60ADH4)
modules
- Simple Motion Module (RD77GF)
- Motion Controller Module (RD77GF)
- C Language Intelligent Function Module (RD55UP06-V)
The following modules which support the CC-Link IE Field Network have been supported.
Support new
139 1.020W - Block type I/O module (NZ2GFCF1-32D, NZ2GFCF1-32T, and Z2GFCF1-32DT)
modules
The following functions have been supported for the Simulation function.
- Simulation for Multiple CPU
- Simulation of RnSFCPU (R08SFCPU, R16SFCPU, R32SFCPU, and R120SFCPU)
138 1.020W Add new function - Simulation of RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU)
- SFC program execution in the simulation function of RnCPU ((R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU)
- Cooperation with multiple simulation functions of RD77MS
- I/O system setting (Process control response operation)
SFC language has been supported for RnPCPU (R08PCPU, R16PCPU, R32PCPU and R120PCPU).
137 1.020W Add new function
The following function has been supported for SFC program.
- Editing multiple initial steps in SFC editor
- Editing jump in SFC editor
136 1.020W Add new function - Copy function of Zoom data of SFC editor
- Find/Replace function of SFC Block Information
- Individual display of the verification result for SFC program and Zoom
- SFC auto-scroll monitor function
Verify with PLC function has been supported for FBD/LD and SFC programs.
135 1.020W Add new function
Setting to Adjust Clock for Daylight Saving Time function has been supported for RnCPU (R04CPU, R08CPU, R16CPU, R32CPU, and
134 1.020W Add new function R120CPU) and RnENCPU (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, and R120ENCPU)
Amplifier-less operation function has been supported for Positioning Modules (RD75D2/D4/P2/P4).
133 1.020W Add new function
English and Chinese version has been supported for the following module of MELSEC iQ-R Series.
132 1.020W Add new function - MES Interface Module (RD81MES96)
Open GX Works2 Format Project function has been improved so that the following settings can be imported.
- Multiple CPU setting, Boot File setting, SFC setting of PLC Parameter
131 1.020W Add new function - CC-Link and Ethernet setting of Network Parameter
- Analog module setting and High-Speed counter module setting of Intelligent Function Module
Function in opening a project has been improved so that restoring work window which was shown last time can be cancelled by pressing Ctrl +
Improve
119 1.020W Break keys.
operability
To prevent the incorrect operation at Rebuild All (reassignment), function has been improved so that assignment setting in rebuilding all can be
Improve
118 1.020W set in Options.
operability
The following function has been supported in Library Pool function.
Improve - Select each POU to export
117 1.020W - Select multiple POUs by the operation for Library List
operability
- Set/Display Help by the operation for Library List
Improve Import/Export function for device comment has been improved so that importing/exporting in batch is enabled for multiple devices.
116 1.020W
operability
Required time to edit label editor has been reduced by specifying the option which disable the automatic synchronization with the program editor
Improve
115 1.020W if label name was edited in label editor.
performance
27/31
The following problem has been solved.
114 1.020W - In some cases, it might fail the 'Read from PLC' processing if the system included a program using OUT instruction in which a timer or counter
type label has been set as an argument.
The following problem found in Device Assignment Confirmation function of the RJ61BT11 (CC-Link) module parameter has been solved.
113 1.020W - Some applicable remote registers (RWr, RWw) have been shown as nonapplicable ones.
The following problem found in FBD/LD program or ST program has been solved.
112 1.020W - In some cases, the program might not correctly work if structured array labels were transferred to instruction of MOVE function or an array was
specified as an output argument whose action was user FB.
The following problem found in 'Online Program Change' function has been solved.
- In some cases, Online Program Change might fail if it is executed after changing program in the case that a program using general
function/function block and a program not using them were included.
110 1.020W - - In some cases, CPU error might occur if Online Program Change was executed after changing ladder program in which macro type FB and
subroutine type FB was nested.
- Error might occur if Online Program Change was executed after adding/deleting user FBs.
The following problem occurred under the setting in which 'Yes' was selected for 'Minimize the Temporary Area' setting in Options has been
solved.
109 1.020W - - In some cases, error might occur if an inline structured text was used in FB or assignment and other statement was used at the end of inline
structured text.
- In some cases, the program might not correctly work if series connection (AND) or parallel connection (OR) has been used in FBD/LD.
The following problem found in Ethernet communication between GX Works3 and PLC has been solved.
100 1.020W - In some cases, error might occur in starting communication, displaying Ethernet diagnostics window, and executing remote reset.
Function for SFC editor has been improved so that conversion error is returned if other than step No.0 (S0) is used as the initial step at the first
top left.
99 1.020W - If this it the case, please change the program as follows.
- Set the step No.0 (S0) for the initial step of the first top left.
- Replace the step No. if the step No.(Sn) errored by SFC control instruction was used.
To ensure consistency, description of a decimal marker has been unified as a period regardless of the display format of decimal point for
95 1.020W - Windows.
The following modules have been supported for MELSEC iQ-F series.
Support new CPU: FX5UC-64MT/D, FX5UC-64MT/DSS, FX5UC-96MT/D, FX5UC-96MT/DSS
94 1.019V I/O: FX5-C16EX/D, FX5-C16EX/DS, FX5-C16EYT/D, FX5-C16EYT/DSS
modules
Extension Power Supply: FX5-C1PS-5V
28/31
The following problem has been solved.
89 1.019V -
Conversion error occurred if the ENO of user FB was connected to the EN of instruction parts/general function parts.
88 1.019V - Function for the instruction including multiple words as an argument has been improved so that specifying the array of structure member is
The following problem found in FBD/LD program has been solved.
87 1.019V -
In some cases, the system might not correctly work if a module FB which set a start address was used.
The following problem has been solved.
86 1.019V - In some cases, error might occur if Online Program Change was executed after reading from PLC function for the program including the general
function block.
The following problem has been solved.
85 1.019V - In some cases, conversion result of transition might be invalid for the SFC program including action/transition if the program was read from PLC,
action was edited, and Online Program Change was executed.
The following problem has been solved.
84 1.019V -
Conversion error occurred if a bit type array was set for the SFC block information.
The following problem has been solved.
83 1.019V -
Error occurred in executing Online Program Change if FBs included in the program to which 'No Execution Type' has been set was edited.
The following problem found in Read from PLC function has been solved.
82 1.019V - In some cases, FUN file or Auto-refresh setting of parameter was not read correctly.
Connection related function has been improved so that the last connection information is cleared after the Ethernet direct connection between
73 1.019V - PLC and Personal Computer was established.
The following problem found in a program includes multiple program blocks has been solved.
71 1.019V - Error occurred in the program block included general function blocks if a program block which does not use general function blocks was edited
and written to PLC.
29/31
The following problem found in FX5CPU has been solved.
In some cases, conversion result might be incorrect in the programs shown below if [Yes] has been checked for [Minimize the Temporary Area]
in Options.
- Program including any of the following general functions.
54 1.017T - AND(_E)/OR(_E)/XOR(_E)/BCD_TO_DINT(_E)/DINT_TO_BCD(_E)/INT_TO_TIME(_E)/WORD_TO_TIME(_E)/
DIV(_E)/MOD(_E)/MUL(_E)/EQ(_E)/GE(_E)/GT(_E)/LE(_E)/LT(_E)/DIV_TIME(_E)/MUL_TIME(_E)/
MAX(_E)/MIN(_E)/MUX(_E)/CONCAT(_E)/INSERT(_E)/MID(_E)/SHL(_E)/SHR(_E)
- Program in which label/device of double word type was specified as the element of array.
ST program including multiplication/division operator
The following problem found in FX5CPU has been solved.
53 1.017T - Deleting labels included in label editor was required to update module labels.
A new function has been supported so that users are able to set the execution order for program blocks.
49 1.015R Add new function
A new function has been supported for verify function so that users are able to check the differences in ladder diagram.
48 1.015R Add new function
I/O System Setting has been supported for Simulation function.
47 1.015R Add new function
A new function has been supported for the program editor so that users are able to monitor the device data of Memory Dump.
46 1.015R Add new function
Memory capacity size calculation function under offline status has been supported.
45 1.015R Add new function
A new option to reduce the number of steps for program has been added.
44 1.015R Add new function
SFC language has been supported.
43 1.015R Add new function Please refer to the Technical Bulletin FA-D-0192 for the Note to read the GX Works2 format SFC program in GX Works3.
Function to Open GX Works2 Format Project has been improved so that the following functions can ben imported.
- Multiple CPU Setting, Boot File Setting, and SFC Setting of PLC Parameter.
42 1.015R Add new function - CC-Link IE Field Setting, CC-Link IE Control Setting of Network Parameter.
- Setting for the QD75 type Positioning Module of Intelligent Function Module.
A new function has been supported to read/write the data for PLC with the Memory Card mounted to the card slot of personal computer.
41 1.015R Add new function
Safety communication function has been supported for CC-Link IE Field Network.
40 1.015R Add new function
Receive buffer full detection signal has been supported for the Ethernet communication for RJ71EN71.
39 1.015R Add new function
New functions shown below have been supported for 'CC-Link IE Field Diagnostics'.
- Detect the error frame reception status in three steps depending on its occurrence frequency.
- Detect the network connection status.
38 1.015R Add new function - Detect the parameter setting status.
- Detect the station type match status.
- Detect the network No. match status.
- Detect the Station No. duplication occurrence status.
Module label and sample comment of RnCPUs shown below have been supported for SFC.
37 1.015R Add new function R04CPU, R08CPU, R16CPU, R32CPU, R120CPU
Function to Open GX Works2 Format Project for FX5CPU has been improved so that the program of Structure Ladder/FBD and the data of
36 1.015R Add new function Device Memory can be imported.
'Read Module Configuration from PLC' function has been supported for FX5CPU.
35 1.015R Add new function
30/31
The following problem has been solved.
25 1.015R - In some cases, Fixed Scan Communication Area Setting of multiple CPU setting might not be applied if system parameters were imported.
The following problem found in the function for the positioning module has been solved.
24 1.015R - Value could be pasted to the masking positioning data in the setting window.
The following problem found in 'Device/Buffer Memory Batch Monitor' has been solved.
23 1.015R - In some cases, the operation of GX Works3 might be stopped if 'Close All Windows' was executed immediately after executing the 'Start
Monitoring (All Windows)'.
The following problem found in 'System Monitor' function has been solved.
20 1.015R - In some cases, 'Event History' window might not be opened.
The following problem found in a program including NOP has been solved.
18 1.015R - In some cases, the operation of GX Works3 might be unstable if the ladder was temporarily changed.
The following problem found in FBD/LD language program has been solved.
14 1.015R - In some cases, the operation of GX Works3 might be unstable if 'Check Program' was executed.
The following problem found in device comment editor has been solved.
7 1.015R - In some cases, the operation of GX Works3 might be unstable if 327680 or more data were pasted.
The following problem found in the function for 'Module Tool List' has been solved.
5 1.015R - In some cases, the operation of GX Works3 might be unstable in executing the Preset for Q series.
The following problem found in 'Print' or 'Print Preview' function of ladder program has been solved.
4 1.015R - In some cases, device comment or statement/note and other information might be output regardless of the 'Additional Information' setting.
The following problem found in 'Open GX Works2 Format Project' function of FX5CPU has been solved.
3 1.015R - The program including the real constant of 6-digit was not reflected to the project of GX Works3.
The following problem found in the function for FX5CPU has been solved.
2 1.015R - In some cases, version information might not be correctly shown in 'Module Diagnostics (CPU Diagnostics)' function.
The following problem found in the function for FX5CPU has been solved.
1 1.015R - In some cases, the operation of GX Works3 might be unstable if the Offset/Gain Setting tool of analog input/output was started without
connecting to PLC.