0% found this document useful (0 votes)
34 views2 pages

2VT469

This document provides specifications for the Model 2VT469 3-Phase Voltage Transformer. It is a 60 Hz transformer manufactured to meet ANSI and IEC standards with a 600 Volt insulation level and 10 kV BIL. It has an accuracy of +1% at burdens up to 5 VA at power factors of 1.0 and 0.95. Thermal ratings are 40 VA at 30°C ambient and 27 VA at 55°C ambient. It comes in various voltage ratios and is designed to operate line-to-line or at reduced voltage line-to-ground or line-to-neutral.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views2 pages

2VT469

This document provides specifications for the Model 2VT469 3-Phase Voltage Transformer. It is a 60 Hz transformer manufactured to meet ANSI and IEC standards with a 600 Volt insulation level and 10 kV BIL. It has an accuracy of +1% at burdens up to 5 VA at power factors of 1.0 and 0.95. Thermal ratings are 40 VA at 30°C ambient and 27 VA at 55°C ambient. It comes in various voltage ratios and is designed to operate line-to-line or at reduced voltage line-to-ground or line-to-neutral.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

3

3 P
Phha
asse
e V
Voollt
taag
gee T
Trra
anns
sffo
orrm
meer
r

Model 2VT469

REGULATORY AGENCY APPROVALS

Manufactured to meet the requirements of ANSI/IEEE C57.13.

Classified by U.L. in accordance with IEC 44-1

FREQUENCY:

60 Hz.

STANDARD

SECONDARY VOLTAGE:

120 Volts

INSULATION LEVEL:

600 Volt , 10 kV BIL full wave.

ACCURACY CLASS:

+ 1% at all burdens up to 5 VA at 1.0 and 0.95 P.F.

THERMAL RATING:
o o

40 VA at 30 C. amb., 27 VA at 55 C. amb.

Terminals are No. 6-32 screws with one

lockwasher and one flatwasher.

Approximate weight 4.5 lbs.

Clear Plastic Cover

CATALOG VOLTAGE TURNS REC. PRIMARY

NUMBER RATIO RATIO FUSE RATING

2VT469—069 69.3:120 0.58:1 1.5 9


2VT469—120 120:120 1:1 1.0

2VT469—208 208:120 1.73:1 0.5

2VT469—240 240:120 2:1 0.5

2VT469—277 277:120 2.31:1 0.5

2VT469—288 288:120 2.4:1 0.4

2VT469—300 300:120 2.5:1 0.4

2VT469—346 346:120 2.88:1 0.4

*2VT469—480 *480:120 4:1 0.25

*2VT469—600 *600:120 5:1 0.25

Section 9 15
M
Mood
deell 2
2VVT
T446
699

See page 17 for 3-Phase 4 W ire connected version

• The core and coil assembly is encased in a thermoplastic shell and filled with resin.

• These transformers are designed for operation line-to-line. They may also be operated line -to-ground

or line-to-neutral at reduced voltage voltage, (58% of rated volts).

• It is desirable to use a 0.40 amp fuse in the secondary to protect the transformer.

• With two exceptions these transformer are ANSI C57.13 group 1. Those marked * are group 2.

• Models designed specifically for 50Hz operation are available with reduced performance. Consult

factory for details.

• Model 2VT469 is an assembly of two transformers in one case with all terminals accessible, for open

delta connection.

• Each transformer has a clear plastic cover.

CONNECTION DIAGRAM

USA, Canada, Asia, Latin America Europe, Middle East , Africa

Tel: +1-800-547-8629 Tel: +34-94-485-88-00

Fax: +1-905-201-2455 Fax: +34-94-485-88-45

e-mail: [email protected] e-mail: [email protected]

16 Section 9 Please refer to our website www.GEMultilin.com for more detailed contact information CS00A40625 Rev.

You might also like