PIM Master Anritsu MW82119B

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Technical Data Sheet

PIM Master™
Passive Intermodulation Analyzer with
Site Master™ Cable & Antenna Analyzer

MW82119B
LTE 600 w/1900 MHz, LTE 700, APT 700, LTE 800,
Cellular 850, E-GSM 900, DCS 1800, PCS/AWS, UMTS 2100, LTE 2600
PIM Master™ Technical Data
Introduction
Anritsu introduces the first fully integrated Passive Intermodulation (PIM) Analyzer plus Cable and Antenna Analyzer
(Option 331) suitable for commissioning and maintaining global wireless networks. This high-performance,
battery-operated unit allows operators to fully characterize infrastructure quality by measuring Return Loss, VSWR,
Cable Loss, Passive Intermodulation, Distance-to-Fault, and Distance-to-PIM.

Passive Intermodulation (PIM) Analyzer Highlights


• PIM vs. Time, Swept PIM, Noise Floor, Distance-to-PIM
• 3rd, 5th, and 7th order intermodulation products detected
• Test Power: 20 dBm to 46 dBm
• Residual PIM: –125 dBm typical

Cable and Antenna Analyzer Highlights (Option 331)


• Measurements: RL, VSWR, Cable Loss, DTF, Phase
• DTF Time Delay
• Frequency range: 2 MHz to 3 GHz
• Sweep Speed: 1 ms/data point typical
• Calibration: OSL and FlexCal™

Capabilities and Functional Highlights


• Integrated solution • Battery operated: >3.0 hour run time
• Display: 8.4 in (213 mm) daylight viewable • IP54 rated for dust and water spray
• MIL-STD-810G drop test rated • Stainless steel lifting rings
• Padded soft case for extra protection • Easy-to-use, menu-driven user interface
• Quick Name Matrix simplifies naming in the field • GPS tag measurements (Option 31)
• High Accuracy Power Meter (Option 19)

Size: 350 mm x 314 mm x 152 mm (13.8 in x 12.4 in x 6.0 in)


Lightweight: 9.2 kg to 12.4 kg (20 lb to 27 lb) depending on options

2 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Table of Contents
Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
PIM Analyzer Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cable and Antenna Analyzer (Option 331). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GPS Receiver (Option 31) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
High Accuracy Power Meter (Option 19) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Line Sweep Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
easyTest Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Web Remote Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Programmable Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Standard Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
USB Power Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Manuals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Definitions All specifications and characteristics apply to Revision 2 instruments under the following conditions, unless
otherwise stated:
Warm-Up Time After 10 minutes of warm-up time, where the instrument is left in the on state.
Typical Performance Typical specifications are not tested and are not warranted. They are generally representative of the
nominal characteristic performance.
Uncertainty A coverage factor of K=2 is applied to the measurement uncertainties.
Calibration Cycle Recommended calibration cycle is 12 months.
All specifications subject to change without notice. For the most current data sheet, please visit the Anritsu
web site: www.anritsu.com

MW82119B TDS PN: 11410-00821 Rev. AF 3 of 20


MW82119B Specifications
General Specifications
PIM Master Connectors
PIM Test Port 7/16 DIN, female, 50 Ω
Dual USB Type A 2x Type A (connect USB Flash Drive and USB Power Sensor)
USB Mini-B 1x Mini-B (connect to PC for data transfer)
GPS SMA, female (with GPS option only)
External Power 2.1 mm x 5.5 mm barrel connector, 12 VDC to 15 VDC, < 5.0 A
PIM Test Port Damage Level +10 dBm (10 mW) continuous, (PIM Rx band)
+35 dBm (3 W) continuous, (PIM Tx band)*
1900 MHz In Test Port Type N, Female, 50 Ω (Option 600)
1900 MHz In Test Port Damage Level +10 dBm (10 mW) continuous, 1900 MHz Rx band)
VNA Test Port Type N, female, 50 Ω (Option 331)
VNA Test Port Damage Level 40 dBm continuous
* Able to survive full reflection of 2 X 46 dBm PIM test tones generated by the MW82119B.

Display
Size 213 mm (8.4 in) touch screen
Resolution 800 x 600
Pixel Defects No more than five defective pixels (99.9989% good pixels)

Battery
Type Li-Ion
Battery Operation 3.0 hours, typical
Charging Limits While charging, battery must be 0 °C to +45 °C, Relative Humidity ≤ 80 %

Power
AC/DC Adapter Input: 100 VAC to 240 VAC, 50/60 Hz
Output: 12 VDC

Regulatory Compliance1
European Union EMC 2014/30/EU, EN 61326-1:2013; CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11;Low Voltage
Directive 2014/35/EU; Safety EN 61010-1:2010; RoHS Directive 2011/65/EU + 2015/863
United Kingdom EMC SI 2016/1091; BS EN 55011 & BS 61000-4-2/3/4/5/6/8/11; Consumer Protection (Safety) SI 2016/1101;
BS EN 61010-1:2010; Environmental Protection SI 2012/3032; 2011/65/EU & 2015/863
Australia and New Zealand RCM AS/NZS 4417:2012
South Korea KCC-REM-A21+-0004
Canada ICES-1(A)/NMB-1(A)

Environmental MIL-PRF-28800F Class 2


Operating Temperature Range –10 ºC to 55 ºC
Storage Temperature Range –51 ºC to 71 ºC
Maximum Relative Humidity 95 % RH at 30 ºC, non-condensing
Vibration, Sinusoidal 5 Hz to 55 Hz
Vibration, Random 10 Hz to 500 Hz
Half Sine Shock 30 gn
Altitude 4600 meters, operating and non-operating
Explosive Atmosphere MIL-PRF-28800F, Section 4.5.6.3; MIL-STD-810G, Method 511.5, Procedure 1
Ingress Protection (IP) IP54, IP67 when enclosed in optional transit case

ESD
PIM Test Port Connector Center Pin Withstands up to ±15 kV
VNA RF Out Connector Center Pin Withstands up to ±15 kV

Size and Weight


Size 350 mm x 314 mm x 152 mm (13.8 in x 12.4 in x 6.0 in)
Weight 9.2 kg to 12.6 kg (20 lb to 27.8 lb), varies by frequency option

Warranty
Duration Standard three-year warranty (one-year warranty on battery)

1. MW82119B-600 (Option 600) is not compliant with CE and RCM radiated emissions requirements.

4 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
PIM Analyzer Specifications
General
Measurements PIM vs. Time, Noise Floor, Distance-to-PIM, Swept PIM
Test Method Reverse (reflected) Passive Intermodulation (PIM) per IEC-62037-1
Intermodulation Order 3rd, 5th, and 7th order, when in receive band (user selectable)
RF Test Frequency Accuracy: ±1.0 ppm at 23 ºC
Stability: ±1.0 ppm from –10 ºC to +55 ºC, typical
Aging: ±1.0 ppm/yr aging, typical

Setup Parameters
Frequency Carrier F1, Carrier F2, Intermodulation Order
Amplitude Ref Value, Scale, Auto Range (On/Off), Amplitude Tone (On/Off)
Setup Output Power, Test Duration (1 s to 1,200 s)
Limit Lines Limit (Upper/Lower), On/Off, Limit Move, Limit Alarm (On/Off, PASS/FAIL indicator)
Markers Markers 1–6 (On/Off), Delta Markers 1–6 (On/Off), Marker to Peak/Valley, All Markers Off
GPS On/Off, 3.3/5.0 V
DTP Cable Velocity, Distance
Save/Recall Setups (.stp), Measurements (.pim), Limit Lines (.lim), Screen Shots (.jpg) (save only)

PIM Analyzer Specifications


PIM Measurement Ranges
RF Test Power Two CW tones 20 dBm to 46 dBm, 0.1 dBm steps
Accuracy: ±0.5 dB (excluding uncertainty)
Residual PIM Performance <–117 dBm, <–125 dBm typical (2x 43 dBm test tones)
<–134 dBm, <–140 dBm typical (2x 20 dBm test tones)
PIM Measurement Range –70 dBm to –140 dBm (Revision 1 instruments)
–50 dBm to –140 dBm (Revision 2 instruments)

Band Option Frequency Range


Tx1: 617 MHz to 618 MHz, Tx2: 633 MHz to 652 MHz
LTE 600 w/1900 MHz Option 600
Rx1: 663 MHz to 698 MHz, Rx2: 1867 MHz to 1888 MHz
Tx1: 731 MHz to 734.5 MHz, Tx2: 746 MHz to 768 MHz
LTE 700 Option 700
RxLower: 698 MHz to 717 MHz, RxUpper: 777 MHz to 806 MHz
Tx1: 758 MHz to 776 MHz, Tx2: 788 MHz to 803 MHz
APT 700 Option 701
RxLower: 710 MHz to 748 MHz, RxUpper: 825 MHz to 845 MHz
Tx1: 791 MHz to 795 MHz, Tx2: 811.5 MHz to 821 MHz
LTE 800 Option 800
Rx: 832 MHz to 862 MHz
Tx1: 869 MHz to 871 MHz, Tx2: 881.5 MHz to 894 MHz
Cellular 850 Option 850
Rx: 824 MHz to 849 MHz
Tx1: 925 MHz to 937.5 MHz, Tx2: 951.5 MHz to 960 MHz
E-GSM 900 Option 900
Rx1: 880 MHz to 915 MHz
Tx1: 1805 MHz to 1837 MHz, Tx2: 1857.5 MHz to 1880 MHz
DCS 1800 Option 180
Rx: 1710 MHz to 1785 MHz
Tx1: 1930 MHz to 1945 MHz, Tx2: 1965 MHz to 1995 MHz, Tx3: 2110 MHz to 2155 MHz
PCS/AWS Option 194
Rx1: 1850 MHz to 1910 MHz (using Tx1 and Tx2), Rx2: 1710 MHz to 1755 MHz (using Tx1 and Tx3)
Tx1: 2110 MHz to 2112.5 MHz, Tx2: 2130 MHz to 2170 MHz
UMTS 2100 Option 210
RxLower: 1920 MHz to 1980 MHz, RxUpper: 2050 MHz to 2090 MHz
Tx1: 2620 MHz to 2630 MHz, Tx2: 2650 MHz to 2690 MHz
LTE 2600 Option 260
Rx: 2500 MHz to 2570 MHz

MW82119B TDS PN: 11410-00821 Rev. AF 5 of 20


MW82119B Specifications
PIM Analyzer Specifications (continued)

PIM vs. Time


Description IM product magnitude vs. time
Test Frequencies F1, F2, and IM product frequencies fixed, user selectable
Measurements Peak PIM over measurement duration, Instantaneous PIM

Noise Floor (Time View)


Description Noise level vs. time at IM product frequency
Test Frequencies IM product frequency fixed, user selectable
Measurements Peak signal level over measurement duration, Instantaneous signal level

Noise Floor (Spectrum View)


Description Noise level vs. frequency
Test Frequencies Swept measurement over Rx band of instrument
Measurements Peak signal level, Instantaneous signal level

Distance-to-PIM
Description IM product magnitude vs. distance
Test Frequencies F1 or F2 frequency swept to produce range of IM product frequencies for analysis
Fault Resolution Varies by frequency option, <3 m (<10 ft) typical with Enhanced Resolution activated
Maximum Range Varies by frequency option and number of Data Points selected
Markers Standard marker functions plus Marker Table (On/Off)
Trace Overlay DTP/DTP, DTP/DTF

Swept PIM
Description IM product magnitude vs. frequency
Test Frequencies F1 and F2 frequencies swept to produce range of IM product frequencies
Measurements Peak PIM over measurement duration, Instantaneous PIM

Cable and Antenna Analyzer (Option 331)


Measurements
Measurements VSWR
Return Loss
Cable Loss
Distance-to-Fault (DTF) Return Loss
Distance-to-Fault (DTF) VSWR
1-Port Phase
Smith Chart (50/75  selectable)

Setup Parameters
Measurement Display Single/Dual Measurement Display with independent markers
Frequency Start/Stop, Signal Standard, Start Cal
DTF Start/Stop, DTF Aid, Units (m/ft), Cable Loss, Propagation Velocity, Cable, Windowing
Windowing Rectangular, Nominal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude Top, Bottom, Auto Scale, Full Scale
Sweep Run/Hold, Single/Continuous, RF Immunity (High/Low), Data Points, Averaging/Smoothing,
Output Power (High), RF Pwr When Hold (On/Off)
Data Points 137, 275, 551, 1102, 2204
Markers Markers 1-6 (On/Off), Delta Makers 1-6 (On/Off), Marker to Peak/Valley, Peak/Valley Auto, DTF Time Delay,
Marker Table (On/Off), All Markers Off
Traces Recall, Copy to Display Memory, No Trace Math, Trace ± Memory, (Trace + Memory)/2, and Trace Overlay
(On/Off)
Limit Line On/Off, Single Limit, Multi-segment Edit, Limit Alarm (On/Off), Pass Fail Message (On/Off),
Pass/Fail (Unbounded/Bounded), Warning Limit Offset, Clear Limit
Calibration Start Cal, Cal Type (Standard/FlexCal), Disp Valid Cal Temp Range
Save/Recall Setups (.stp), Measurements (.dat, .vna), Screen Shots (.jpg) (save only)
Application Options Impedance (50 , 75 , Other)

Frequency
Frequency Accuracy ±1.0 ppm at 23 ºC
Stability ±1.0 ppm from –10 ºC to +55 ºC, typical
Aging ±1.0 ppm/yr, typical

Output Power
Power Level –4 dBm, typical

6 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Interference Immunity
On-Channel +17 dBm @ > 1.0 MHz from carrier frequency
On-Frequency 0 dBm within ± 10 kHz of the carrier frequency

Measurement Speed
Return Loss  1.00 ms/data point, RF immunity low, typical
Distance-to-Fault  1.25 ms/data point, RF immunity low, typical

Return Loss
Measurement Range 0 dB to 60 dB
Resolution 0.01 dB

VSWR
Measurement Range 1:1 to 65:1
Resolution 0.01

Cable Loss
Measurement Range 0 dB to 30 dB
Resolution 0.01 dB

Distance-to-Fault
Vertical Range Return Loss 0 dB to 60 dB
Vertical Range VSWR 1:1 to 65:1
Fault Resolution (meters) (1.5 x 108 x vp) / F (vp = velocity propagation constant, F is F2–F1 in Hz)
Horizontal Range (meters) 0 to (Data Points–1) x Fault Resolution, to a maximum of 1500 meters (4921 ft)

1-Port Phase
Measurement Range –180 º to +180 º
Resolution 0.01 º

Smith Chart
Resolution 0.01 50/75 Ω Selectable

Cable and Antenna Analyzer (Option 331) (continued)

Measurement Accuracy
Corrected Directivity > 42 dB, OSL Calibration

Measurement Uncertainty

Return Loss Uncertainty - 2 MHz to 3 GHz Phase Uncertainty - 2 MHz to 3 GHz


10 100
Phase Uncertainty (degrees)
Return Loss Uncertainty (dB)

1 10

0.1 1
-40 -35 -30 -25 -20 -15 -10 -5 0 -40 -35 -30 -25 -20 -15 -10 -5 0
Return Loss (dB) Return Loss (dB)

GPS Receiver (Option 31) (Antenna sold separately)


Setup On/Off, Antenna Voltage 3.3/5.0 V, GPS Info
GPS Time/Location Indicator Time, Latitude, Longitude and Altitude on display
Time, Latitude, Longitude and Altitude with trace storage
Connector SMA(f)

High Accuracy Power Meter (Option 19) (requires external USB Power Sensor)
Amplitude Maximum, Minimum, Offset, Relative On/Off, Units, Auto Scale
Average # of Running Averages, Max Hold
Zero/Cal Zero On/Off, Cal Factor (Center Frequency, Signal Standard)
Limits Limit On/Off, Limit Upper/Lower

MW82119B TDS PN: 11410-00821 Rev. AF 7 of 20


MW82119B Specifications
Power Sensor Model MA24105A MA24106A MA24108A/18A/26A MA24208A/18A MA24330A/40A/50A
Description Inline High High Accuracy Microwave USB Microwave Microwave CW USB
Power Sensor RF Power Sensor Power Sensor Universal USB Power Sensor
Power Sensor
Frequency Range 350 MHz to 4 GHz 50 MHz to 6 GHz 10 MHz to 10 MHz to 8/18 GHz 10 MHz to
8/18/26 GHz 33/40/50 GHz
Connector Type N(f), 50 Ω Type N(m), 50 Ω Type N(m), 50 Ω Type N(m), 50 Ω Type K(m), 50 Ω
(8/18 GHz) (33/40 GHz)
Type K(m), 50 Ω Type V(m), 50 Ω
(26 GHz) (50 GHz)
Dynamic Range +3 dBm to –40 dBm to –40 dBm to –60 dBm to –70 dBm to
+51.76 dBm +23 dBm +20 dBm +20 dBm +20 dBm
(2 mW to 150 W) (0.1 µW to 200 mW) (0.1 µW to 100 mW) (1 nW to 100 mW) (0.1 nW to 100 mW)
Measurand True-RMS True-RMS True-RMS, Slot True-RMS, Slot Average Power
Power, Burst Power, Burst
Average Power Average Power
Measurement Uncertainty ± 0.17 dBa ± 0.16 dBb ± 0.18 dBc ± 0.17 dBd ± 0.17 dBe
Data sheet 11410-00621 11410-00424 11410-00504 11410-00841 11410-00906
(for complete specifications)
Notes: a. Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load.
Measurement results referenced to the input side of the sensor.
b. Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero
mismatch errors.
c. Expanded uncertainty with K=2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors.
d. Power uncertainty expressed with two sigma confidence level for CW measurement after zero operation. Includes
calibration factor and linearity over temperature uncertainties, but not the effects of mismatch, zero set and drift, or noise.
e. Includes linearity over temperature uncertainties, but not the effects of calibration factor, mismatch, zero set and drift, and
noise.

8 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Line Sweep Tools (for your PC)

Trace Capture
Browse to Instrument View and copy traces from the test equipment to your PC using Windows Explorer
Open Current Files Open PIM or DAT files
Capture Plots To The Line Sweep Tools screen, DAT files, Database, or JPEG

Traces
Trace Types Return Loss, VSWR, DTF-RL, DTF-VSWR, Cable Loss, Smith Chart, PIM vs. Time, Swept PIM, Noise Floor, and DTP
Trace Formats DAT, PIM, CSV, PNG, BMP, JPG, HTML, Data Base, and PDF

Report Generation
Report Generator Includes GPS location along with measurements
Report Format Create reports in HTML or PDF format
Report Setup Report Title, Company, Prepared for, Location, Date and Time, Filename, Company logo
Trace Setup 1 Trace Portrait Mode, 2 Trace Portrait Mode, 1 Trace Landscape Mode
PIM Report Tabular summary report with pass/fail analysis

Trace Validation
Presets 7 presets allow “one click” setting of up to 6 markers and one limit line
Marker Controls 6 regular Markers, Marker Peak, Marker Valley, Marker between, and frequency entry
Delta Markers 6 Delta markers
Limit Line Enable and drag or value entry. Also works with presets
Next Trace Button Next Trace and Previous trace arrow keys allow quick switching between traces

Tools
Cable Editor Allows creation of custom cable parameters
Distance to Fault Converts a Return Loss trace to a Distance to Fault trace
Measurement Calculator Converts Real, Imaginary, Magnitude, Phase, RL, VSWR, Rho, and Transmit power
Signal Standard Editor Creates new band and channel tables
Renaming Grid 36 user definable phrases for creation of file names, trace titles, and trace subtitles

Connectivity
Connections USB cable, USB Memory Stick

easyTest Tools (for your PC)


Instrument Mode PIM Analyzer Mode, Cable & Antenna Analyzer Mode (Option 331)

Commands
Display Image Allows putting a custom image on the instrument screen
Recall Setup Places the instrument into a known state
Prompt Displays instructional messages on the instrument screen
Save Allows automatic or manual saving of traces

Connectivity
Connections Ethernet, USB cable or USB memory stick

MW82119B TDS PN: 11410-00821 Rev. AF 9 of 20


MW82119B Specifications
Web Remote Control
Control Full instrument control through a browser – all instrument functions except power switch
Connections RJ45 Ethernet jack
Third-party Wi-Fi router
Protocol HTTP/TCP/IP
Physical Layer Cat 5 Cable, Wi-Fi router compatible
Browser Designed for use with HTML 5 Compliant Browsers (Google Chrome or Mozilla Firefox preferred)
Operating System iOS, Windows, Linux, Android operating systems that can host the HTML 5 compliant browser
Remote Hardware PCs, Tablets, and Smart Phones with Ethernet or Wi-Fi connections
Download Individual instrument files downloaded via browser
Multiple instrument files and directories zipped and downloaded via browser
Screen capture capability
File downloads are not supported by iOS
Display Modes Normal: All modes & displays supported
Fast: Not currently supported
Password The instrument can be password protected
Passwords may be used to manage who controls the instrument
Users and Devices to Instruments Ratio One device can view and control many instruments

Programmable Remote Control


Functionality Instrument functionality is available via remote programming.
See the MW82119B Programming Manual for details.
Programming Language Standard Commands for Programmable Instruments (SCPI)
Interfaces USB, LAN

10 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Ordering Information
Model Number Description
MW82119B PIM Master™ Passive Intermodulation Analyzer
(must be ordered with ONE frequency option)
Frequency Options (must order one, and only one)
MW82119B-0600 LTE 600 w/1900 MHz
MW82119B-0700 LTE 700
MW82119B-0701 APT 700
MW82119B-0800 LTE 800
MW82119B-0850 Cellular 850
MW82119B-0900 E-GSM 900
MW82119B-0180 DCS 1800
MW82119B-0194 PCS/AWS 1900/2100
MW82119B-0210 UMTS 2100
MW82119B-0260 LTE 2600
Other Options
MW82119B-0019 High Accuracy Power Meter (requires USB power sensor)
MW82119B-0031 GPS Receiver (requires GPS antenna)
MW82119B-0331 Site Master™ Cable and Antenna Analyzer
MW82119B-0098 Standard Calibration to ISO 17025 and/or Z540.1
MW82119B-0099 Premium Calibration to ISO 17025 and/or Z540.1 plus test data

MW82119B TDS PN: 11410-00821 Rev. AF 11 of 20


MW82119B Specifications
Standard Accessories (included with instrument)
Accessory Description Accessory Description

2000-1786-R 2000-1797-R
Soft Carrying Case, Screen Access Screen Protector Film, 8.4 in

2000-1691-R 2000-1371-R
Stylus with Coiled Tether Ethernet Cable, 7 ft (213 cm)

40-187-R
633-75
AC-DC Adapter with AC Power Cord (country
Rechargeable Li-Ion Battery, 7500 mAh
dependent)

806-141-R 3-2000-1498
Automotive Power Adapter, 12 VDC, 60 W USB A/5-pin mini-B Cable, 10 ft (305 cm)

1091-422-R
2000-1714-R
Adapter, 7/16 DIN(f) to 7/16 DIN(m), 50 Ω (Connector
Shoulder Strap
Saver)

USB Power Sensors (for complete ordering information, see the respective data sheets of each sensor)
Accessory Description Accessory Description
MA24330A MA24108A
Microwave CW USB Power Sensor, 10 MHz to 33 GHz, Microwave USB Power Sensor,
+20 dBm 10 MHz to 8 GHz, +20 dBm to –40 dBm
MA24340A MA24118A
Microwave CW USB Power Sensor, 10 MHz to 40 GHz, Microwave USB Power Sensor,
+20 dBm 10 MHz to 18 GHz, +20 dBm to –40 dBm
MA24350A MA24126A
Microwave CW USB Power Sensor, 10 MHz to 50 GHz, Microwave USB Power Sensor,
+20 dBm 10 MHz to 26 GHz, +20 dBm to –40 dBm
MA24208A
Microwave Universal USB Power Sensor,
10 MHz to 8 GHz, +20 dBm to –60 dBm MA24105A
Inline Dual Directional High Power Sensor,
MA24218A 350 MHz to 4 GHz, +3 dBm to +51.76 dBm
Microwave Universal USB Power Sensor,
10 MHz to 18 GHz, +20 dBm to –60 dBm

MA24106A
MA25100A
High Accuracy RF Power Sensor,
RF Power Indicator
50 MHz to 6 GHz, +23 dBm to –40 dBm

12 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Manuals (Soft copy at www.anritsu.com)
Part Number Description
10100-00065 Product Information Safety and Compliance
10580-00400 PIM Master User Guide
10580-00402 PIM Master Measurement Guide
10580-00403 PIM Master Programming Manual
10580-00240 Power Meter Measurement Guide
10580-00241 Cable and Antenna Analyzer Measurement Guide
11410-00473 Troubleshooting Guide – Cable, Antenna, and Components
11410-00726 Equipment Verification Process

Optional Accessories
Accessory Kits
Accessory Description Accessory Description

2000-1745-R 2000-1476-R
PIM Master Backpack Accessory Kit PIM Master Hard Case Accessory Kit
(Consists of 67135, 2000-1626-R, 2000-1749-R, (Consists of 760-260-R, 2000-1626-R, 2000-1749-R,
1091-446-R, 1091-425-R (qty 2), 1091-426-R (qty 2), 1091-446-R, 1091-425-R (qty 2), 1091-426-R (qty 2),
1091-427-R, 01-510, 01-513-R, 971-9-R, 971-10-R, 1091-427-R, 01-510, 01-513-R, 971-9-R, 971-10-R,
11410-00726) 11410-00726)

Backpack and Transit Case


Accessory Description Accessory Description

760-265-R
67135 Transit Case (holds MW82119A/B PIM Analyzer plus
accessories)
Anritsu Backpack (for handheld instrument and PC)
Exterior Dimensions: 24.76 x 19.57 x 13.90 in
(62.9 x 49.7 x 35.3 cm)

760-259-R 760-260-R
Transit Case (holds MW82119A/B PIM Analyzer only) Transit Case (holds PIM Analyzer Accessories)
Exterior Dimensions: 24.83 x 19.69 x 11.88 in Exterior Dimensions: 24.39 x 19.36 x 8.79 in
(63.1 x 50 x 30.2 cm) (62 x 49.2 x 22.3 cm)

MW82119B TDS PN: 11410-00821 Rev. AF 13 of 20


MW82119B Specifications
Calibration Components, 50 Ω (These components are not designed to withstand PIM test power levels. Suitable for cable and antenna analyzer
measurements only.)
Accessory Description Accessory Description

2000-1619-R
OSLN50A-8
Precision Open/Short/Load, 7/16 DIN(f), DC to
High Performance Type N(m), DC to 8 GHz, 50 Ω
6.0 GHz 50 

OSLNF50A-8 22N50
High Performance Type N(f), DC to 8 GHz, 50 Ω Open/Short, N(m), DC to 18 GHz, 50 

ICN50B 22NF50
Calibration Module, 10 MHz to 6.0 GHz, N(m), 50 Ω Open/Short, N(f), DC to 18 GHz, 50 

2000-1914-R
SM/PL-1
Precision Open/Short/Load, 4.3-10(f), DC to 6 GHz,
Precision Load, N(m), 42 dB, 6.0 GHz
50 

2000-1915-R
SM/PLNF-1
Precision Open/Short/Load, 4.3-10(m), DC to 6 GHz,
Precision Load, N(f), 42 dB, 6.0 GHz
50 

2000-1618-R
Precision Open/Short/Load, 7/16 DIN(m),
DC to 6.0 GHz 50 

14 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Precision Adapters (Recommended for cable and antenna line sweep applications only. Not Low PIM.)
Accessory Description Accessory Description

34NN50A 510-90-R
N(m) to N(m), DC to 18 GHz, 50 Ω 7/16 DIN(f) to N(m), DC to 7.5 GHz, 50 Ω

34NFNF50 510-91-R
N(f) to N(f), DC to 18 GHz, 50 Ω 7/16 DIN(f) to N(f), DC to 7.5 GHz, 50 Ω

1091-26-R 510-92-R
SMA(m) to N(m), DC to 18 GHz, 50 Ω 7/16 DIN(m) to N(m), DC to 7.5 GHz, 50 Ω

1091-27-R 510-93-R
SMA(f) to N(m), DC to 18 GHz, 50 Ω 7/16 DIN(m) to N(f), DC to 7.5 GHz, 50 Ω

1091-80-R 510-96-R
SMA(m) to N(f), DC to 18 GHz, 50 Ω 7/16 DIN(m) to 7/16 DIN (m), DC to 7.5 GHz, 50 Ω

1091-81-R 510-97-R
SMA(f) to N(f), DC to 18 GHz, 50 Ω 7/16 DIN(f) to 7/16 DIN (f), DC to 7.5 GHz, 50 Ω

1091-172-R 510-102-R
BNC(f) to N(m), DC to 1.3 GHz, 50 Ω N(m) to N(m), DC to 11 GHz, 50 Ω, 90° right angle

1091-465-R 1091-467-R
Adapter, DC to 6 GHz, 4.3-10(f) to N(f), 50 Ω Adapter, DC to 6 GHz, 4.3-10(m) to N(f), 50 Ω

MW82119B TDS PN: 11410-00821 Rev. AF 15 of 20


MW82119B Specifications
Low PIM Adapters
Accessory Description Accessory Description

1091-421-R 1091-433-R
Low PIM Adapter, 7/16 DIN(m) to 7/16 DIN(m), DC to Low PIM Adapter, 4.1-9.5(f) to 7/16 DIN(f), DC to
6.0 GHz, 50 Ω 3.0 GHz, 50 Ω

1091-422-R 1091-434-R
Low PIM Adapter, 7/16 DIN(m) to 7/16 DIN(f), DC to Low PIM Adapter, 4.1-9.5(m) to 7/16 DIN(f), DC to
6.0 GHz, 50 Ω 3.0 GHz, 50 Ω

1091-423-R 1091-435-R
Low PIM Adapter, 7/16 DIN(m) to N(m), DC to 6.0 GHz, Low PIM Adapter, 4.1-9.5(f) to N(m), DC to 3.0 GHz,
50 Ω 50 Ω

1091-424-R 1091-436-R
Low PIM Adapter, 7/16 DIN(m) to N(f), DC to 6.0 GHz, Low PIM Adapter, 4.1-9.5(m) to N(m), DC to 3.0 GHz,
50 Ω 50 Ω

1091-425-R 1091-440-R
Low PIM Adapter, 7/16 DIN(f) to N(f), DC to 6.0 GHz, Low PIM Adapter, 4.3-10(f) to 7/16 DIN(f), DC to
50 Ω 6.0 GHz, 50 Ω

1091-426-R 1091-441-R
Low PIM Adapter, 7/16 DIN(f) to N(m), DC to 6.0 GHz, Low PIM Adapter, 4.3-10(m) to 7/16 DIN(f), DC to
50 Ω 6.0 GHz, 50 Ω

1091-427-R 1091-443-R
Low PIM Adapter, 7/16 DIN(f) to 7/16 DIN(f), DC to Low PIM Adapter, 4.3-10(m) to N(m), DC to 6.0 GHz,
6.0 GHz, 50 Ω 50 Ω

1091-431-R 1091-442-R
Low PIM Adapter, 45°, 7/16 DIN(m) to 7/16 DIN(f), DC Low PIM Adapter, 4.3-10(f) to N(m), DC to 6.0 GHz,
to 3.0 GHz, 50 Ω 50 Ω

1091-432-R 1091-446-R
Low PIM Adapter, 45°, 7/16 DIN(f) to 7/16 DIN(f), DC PIM Standard, –80 dBm ±3 dB at 1730 MHz, with 2 x
to 3.0 GHz, 50 Ω 20 W, 7/16 DIN(m) to 7/16 DI (f), 50 Ω

1091-468-R 1091-466-R
Low PIM Adapter, 4.3-10(f) to 7/16 DIN(m), DC to Low PIM Adapter, 4.3-10(m) to 7/16 DIN(m), DC to
6.0 GHz, 50 Ω 6.0 GHz, 50 Ω

16 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
PIM Analyzer Loads
Accessory Description Accessory Description

2000-1749-R 2000-1724-R
Low PIM Load, 700 MHz to 2600 MHz, 10 W, 7/16 Low PIM Load, 663 MHz to 2800 MHz, 40 W, 7/16
DIN(m), 7/16 DIN(f), 50 Ω DIN(m), 7/16 DIN(f), 50 Ω

2000-1913-R
Low PIM Load, 700 MHz to 2600 MHz, 10 W, 4.3-10(m)
to 4.3-10(f), 50 Ω

Attenuators (Recommended for power measurements only. Not Low PIM.)


Accessory Description Accessory Description

3-1010-122 3-1010-124
Attenuator (Bi-directional), 20 dB, 5 W, DC to Attenuator (Bi-directional), 40 dB, 100 W, DC-8.5 GHz,
12.4 GHz, N(m) to N(f) N(f) input to N(m) output, Unidirectional

3-1010-123
Attenuator (Bi-directional), 30 dB, 50 W, DC to
8.5 GHz, N(m) to N(f)

GPS Antennas (active)PIM Analyzer Test Cables


Accessory Description Accessory Description

2000-1528-R 2000-1760-R
Magnet Mount, SMA(m) with 5 m (16.4 ft) cable, Miniature Antenna, SMA(m), requires 2.5 VDC to
requires 5 VDC 3.7 VDC

2000-1652-R
Magnet Mount, SMA(m) with 0.3 m (1 ft) cable,
requires 3.3 VDC or 5 VDC

PIM Test Port Cables


Accessory Description Accessory Description
2000-1626-R 16DD50-2.75-R
PIM Test Cable, 3.0 m, 7/16 DIN(m) to 7/16 DIN(m), Armored PIM Test Cable, 2.75 m, 7/16 DIN(m) to
50 Ω 7/16 DIN(m), 50 Ω
2000-1783-R 16DD50-4.0-R
PIM Test Cable, 3.0 m, 7/16 DIN(m) to 7/16 DIN(f), 50 Armored PIM Test Cable, 4.0 m, 7/16 DIN(m) to
Ω 7/16 DIN(m), 50 Ω
2000-1845-R
PIM Test Cable, 3.0 m, 7/16 DIN(m) to 4.3-10(m), 50 Ω
2000-1846-R
PIM Test Cable, 3.0 m, 7/16 DIN(m) to 4.3-10(f), 50 Ω

MW82119B TDS PN: 11410-00821 Rev. AF 17 of 20


MW82119B Specifications
Interchangeable Adapter Phase Stable Test Port Cables, Armored w/Reinforced Grip (Recommended for cable and antenna line
sweep applications. Not low PIM. It uses the same ruggedized grip as the Reinforced Grip series cables. Now you can also change the adapter interface
on the grip to four different connector types)
Accessory Description
15RCN50-1.5-R
1.5 m, DC to 6 GHz, N(m), N(f), 7/16 DIN(m),
7/16 DIN(f), 50 Ω
15RCN50-3.0-R
3.0 m, DC to 6 GHz, N(m), N(f), 7/16 DIN(m),
7/16 DIN(f), 50 Ω

Phase-Stable Test Port Cables, Armored w/Reinforced Grip (Recommended for cable and antenna line sweep applications only. Not low
PIM.)
Accessory Description Accessory Description
15RDN50-1.5-R 15RNFN50-1.5-R
1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50 Ω 1.5 m, DC to 6 GHz, N(m) to N(f), 50 Ω

15RDFN50-1.5-R 15RNFN50-3.0-R
1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50 Ω 3.0 m, DC to 6 GHz, N(m) to N(f), 50 Ω

15RDN50-3.0-R
3.0 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50 Ω
15RDFN50-3.0-R
3.0 m, DC to 6 GHz, N(m) to 7/16 DIN(f), 50 Ω

Phase-Stable Test Port Cables, Armored (Recommended for cable and antenna line sweep applications only. Not Low PIM. Use with tightly
spaced connectors and other general purpose applications)
Accessory Description Accessory Description
15NNF50-1.5C 15NDF50-1.5C
1.5 m, DC to 6 GHz, N(m) to N(f), 50 Ω 1.5 m, DC to 6 GHz GHz, N(m) to 7/16 DIN(f), 50 Ω

15NN50-1.5C 15ND50-1.5C
1.5 m, DC to 6 GHz, N(m) to N(m), 50 Ω 1.5 m, DC to 6 GHz, N(m) to 7/16 DIN(m), 50 Ω

15N43M50-1.5C
15NNF50-3.0C
Test Port Extension Cable, Armored, 1.5 m,
3.0 m, DC to 6 GHz, N(m) to N(f), 50 Ω
DC to 6 GHz, N(m) to 4.3-10(m)
15N43F50-1.5C
15NN50-3.0C
Test Port Extension Cable, Armored, 1.5 m,
3.0 m, DC to 6 GHz, N(m) to N(m), 50 Ω
DC to 6 GHz, N(m) to 4.3-10(f)
15N43M50-3.0C
15NNF50-5.0C
Test Port Extension Cable, Armored, 3 m,
5.0 m, DC to 6 GHz, N(m) to N(f), 50 Ω
DC to 6 GHz, N(m) to 4.3-10(m)
15N43F50-3.0C
15NN50-5.0C
Test Port Extension Cable, Armored, 3 m,
5.0 m, DC to 6 GHz, N(m) to N(m), 50 Ω
DC to 6 GHz, N(m) to 4.3-10(f)

18 of 20 PN: 11410-00821 Rev. AF MW82119B TDS


Specifications MW82119B
Bandpass Filters
Accessory Description Accessory Description
1030-114-R 1030-151-R
806 MHz to 869 MHz, N(m) to SMA(f), 50 Ω High Pass, 700 MHz, N(m) to N(f), 50 Ω

1030-109-R 1030-152-R
24 MHz to 849 MHz, N(m) to SMA(f), 50 Ω Low Pass, 200 MHz, N(m) to N(f), 50 Ω

1030-110-R 1030-153-R
880 MHz to 915 MHz, N(m) to SMA(f), 50 Ω Low Pass, 550 MHz, N(m) to N(f), 50 Ω

1030-111-R 1030-155-R
1850 MHz to 1910 MHz, N(m) to SMA(f), 50 Ω 2500 MHz to 2700 MHz, N(m) to N(f), 50 Ω

1030-112-R 1030-178-R
2400 MHz to 2484 MHz, N(m) to SMA(f), 50 Ω 1920 MHz to 1980 MHz, N(m) to N(f), 50 Ω
1030-105-R 1030-179-R
890 MHz to 915 MHz, N(m) to N(f), 50 Ω 777 MHz to 798 MHz, N(m) to N(f), 50 Ω

1030-106-R 1030-180-R
1710 MHz to 1790 MHz, N(m) to N(f), 50 Ω 2500 MHz to 2570 MHz, N(m) to N(f), 50 Ω

1030-107-R 2000-1684-R
1910 MHz to 1990 MHz, N(m) to N(f), 50 Ω 791 MHz to 821 MHz, N(m) to N(f), 50 Ω

1030-149-R 2000-2147-R
High Pass, 150 MHz, N(m) to N(f), 50 Ω 3700 MHz to 3980 MHz, N(m) to N(f)
1030-150-R
High Pass, 400 MHz, N(m) to N(f), 50 Ω

Miscellaneous Accessories
Accessory Description Accessory Description

2000-1884-R
2000-1374 PIM Hunter™ Test Probe (For full specifications, refer
External Dual Charger for Li-lon Batteries to the 2000-1884-R Technical Data Sheet
11410-00999)

633-75 2000-1691-R
Rechargeable Li-Ion Battery, 7500 mAh Stylus with Coiled Tether

01-528-R
01-510
Torque Wrench for coupling torque of 4.3-10
Adjustable Wrench
connectors, 22 mm opening

01-201
Torque End Wrench, 5/16 in, 0.9 N·m (8 lbf·in), For 01-513-R
tightening male devices, for SMA, 3.5 mm, 2.4 mm, K, 1-1/4 in Torque Wrench
and V connectors

971-9-R 971-10-R
Cleaning Wipes Cleaning Swabs

MW82119B TDS PN: 11410-00821 Rev. AF 19 of 20


Training at Anritsu
Anritsu has designed courses to help you stay up to date with technologies important to your job. For available training
courses, visit: www.anritsu.com and search for training and education.

• United States • Sweden • Vietnam


Anritsu Americas Sales Company Anritsu AB Anritsu Company Limited
450 Century Parkway, Suite 190, Kistagången 20 B, 2 tr, 164 40 Kista, Sweden 16th Floor, Peakview Tower, 36 Hoang Cau Street,
Allen, TX 75013, U.S.A. Phone: +46-8-534-707-00 O Cho Dua Ward, Dong Da District, Hanoi, Vietnam
Phone: +1-800-Anritsu (1-800-267-4878) Phone: +84-24-3201-2730
• Finland
• Canada Anritsu AB • P.R. China (Shanghai)
Anritsu Electronics Ltd. Technopolis Aviapolis, Teknobulevardi 3-5 (D208.5.), Anritsu (China) Co., Ltd.
Americas Sales and Support FI-01530 Vantaa, Finland Room 2701-2705, Tower A, New Caohejing
450 Century Parkway, Suite 190, Phone: +358-20-741-8100 International Business Center No. 391 Gui Ping Road
Allen, TX 75013, U.S.A. Shanghai, 200233, P.R. China
Phone: +1-800-Anritsu (1-800-267-4878) • Denmark Phone: +86-21-6237-0898
Anritsu A/S Fax: +86-21-6237-0899
• Brazil c/o Regus Winghouse, Ørestads Boulevard 73, 4th floor,
Anritsu Eletronica Ltda. 2300 Copenhagen S, Denmark • P.R. China (Hong Kong)
Praça Amadeu Amaral, 27 - 1 Andar Phone: +45-7211-2200 Anritsu Company Ltd.
01327-010 - Bela Vista - Sao Paulo - SP, Brazil Unit 1006-7, 10/F., Greenfield Tower, Concordia Plaza,
Phone: +55-11-3283-2511 • Spain No. 1 Science Museum Road, Tsim Sha Tsui East,
Fax: +55-11-3288-6940 Anritsu EMEA Ltd. Kowloon, Hong Kong, P.R. China
Representation Office in Spain Phone: +852-2301-4980
• Mexico Paseo de la Castellana, 141. Fax: +852-2301-3545
Anritsu Company, S.A. de C.V. Planta 5, Edificio Cuzco IV
Blvd Miguel de Cervantes Saavedra #169 Piso 1, 28046, Madrid, Spain • Japan
Col. Granada, Mexico, Ciudad de Mexico, Phone: +34-91-572-6761 Anritsu Corporation
11520, MEXICO 8-5, Tamura-cho, Atsugi-shi, Kanagawa, 243-0016 Japan
Phone: +52-55-4169-7104 • Austria Phone: +81-46-296-6509
Anritsu EMEA GmbH Fax: +81-46-225-8352
• United Kingdom Am Belvedere 10, A-1100 Vienna, Austria
Anritsu EMEA Ltd. Phone: +43-(0)1-717-28-710 • South Korea
200 Capability Green, Anritsu Corporation, Ltd.
Luton, Bedfordshire, LU1 3LU, U.K. • United Arab Emirates 8F, A TOWER, 20, Gwacheondaero 7-gil, Gwacheon-si,
Phone: +44-1582-433200 Anritsu EMEA Ltd. Gyeonggi-do, 13840, Republic of Korea
Fax: +44-1582-731303 Anritsu A/S Phone: +82-2-6259-7300
Office No. 164, Building 17, Dubai Internet City Fax: +82-2-6259-7301
• France P. O. Box – 501901, Dubai, United Arab Emirates
Anritsu S.A. Phone: +971-4-3758479 • Australia
12 avenue du Québec, Immeuble Goyave, Anritsu Pty. Ltd.
91140 VILLEBON SUR YVETTE, France • India Unit 20, 21-35 Ricketts Road,
Phone: +33-1-60-92-15-50 Anritsu India Private Limited Mount Waverley, Victoria 3149, Australia
6th Floor, Indiqube ETA, No.38/4, Adjacent to EMC2, Phone: +61-3-9558-8177
• Germany Doddanekundi, Outer Ring Road, Fax: +61-3-9558-8255
Anritsu GmbH Bengaluru – 560048, India
Nemetschek Haus, Konrad-Zuse-Platz 1, Phone: +91-80-6728-1300 • Taiwan
81829 München, Germany Fax: +91-80-6728-1301 Anritsu Company Inc.
Phone: +49-89-442308-0 7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan
Fax: +49-89-442308-55 • Singapore Phone: +886-2-8751-1816
Anritsu Pte. Ltd. Fax: +886-2-8751-1817
• Italy 1 Jalan Kilang Timor, #07-04/06 Pacific Tech Centre
Anritsu S.r.l. Singapore 159303
Spaces Eur Arte, Viale dell’Arte 25, 00144 Roma, Italy Phone: +65-6282-2400
Phone: +39-6-509-9711 Fax: +65-6282-2533
List Revision Date: 20230901

Data subject to change without notice. MW82119B TDS, PN: 11410-00821, Rev. AF
For the most recent specifications, visit: www.anritsu.com. Copyright November 2023, Anritsu Company, USA. All Rights Reserved.
20 ® Anritsu All trademarks are registered trademarks of their respective companies.
20 of 20 Anritsu utilizes recycled paper and environmentally conscious inks and toner.

You might also like