Metrix MX5060
Metrix MX5060
Metrix MX5060
Bench-top Multimeters
TECHNICAL SPECIFICATIONS MX 5060 * MX 5006
DC, AC and AC+DC voltages
Range 60 mV* 600 mV 6V 60 V 600 V 1000 V 6,000 and 60,000 counts
Resolution* 0.001 mV 0.01 mV 0.0001 V 0.001 V 0.01 V 0.1 V
DC accuracy 0.05% 0.09%
AC and AC+DC bandwidth
AC ans AC+DC basic accuracy 0.5%
100 kHz
0.8%
MX 5006
VLowZ AC basic accuracy (520 kΩ) 0.5% 1.2%
DC, AC and AC+DC current
Range 6000 µA 60 mA 600 mA 6A 10 A / 20 A (30 s max)
MX 5060
Resolution* 0.1 µA 0.001 mA 0.01 mA 0.0001 A 0.001 A
DC accuracy 0.8%
AC and AC+DC bandwidth 20 kHz 10 kHz
AC and AC+DC accuracy 1%
Frequency
Frequency range 60 Hz 600 Hz 6 kHz 60 kHz
Resolution* 0.01 Hz 0.1 Hz 1 Hz 10 Hz
Resistance and continuity
Range 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 MΩ
Resolution* 0.01 Ω 0.1 kΩ 0.001 kΩ 0.01 kΩ 0.0001 MΩ 0.001 MΩ
Basic accuracy 0.2% 0.4%
Protection 1,000 V electronic protection
Audible continuity detection 600 Ω SIGNAL <30 Ω +/-5 Ω < 5V
Diode test
Voltage measurement 3 V, resolution 1 mV + Buzzer <40 mV ±10 mV
Capacitances
Range 6 nF 60 nF 600 nF 6 µF 60 µF 600 µF 6 mF 60 mF
Resolution 0.001 nF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1 µF 10 µF
K thermocouple temperature
Operating range -200 °C to +1,200 °C
Accuracy / Resolution 0.5% R / 0.1 °C
Other functions
Min/Max/Peak ± On all positions measured
ΔREL MEM relative value on secondary display subtracted from the measured value on the main display
PWM filter 4th-order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors
Central Zero VDC and IDC with central zero
USB communication With SX-DMM2 software – SCPI commands
AD.COM - Code : 906211382 - Ed.1 - 09/2013 - Characteristics subject to modifications according to technological developments.
Measurement rate and bargraph 5 measurements per second and 61-segment bargraph for analogue function
General specifications
Display type Transflective LCD with backlighting, broadened viewing angle and 16 mm digits
60,000-count* or 6,000-count double display
PC interfaces USB type B connector – SX-DMM2 software
Mains power supply Universal 230 V / 47-63 Hz / removable mains lead and 110V** version < 2 VA
Safety / EMC Safety as per IEC61010-1 (2001) 1000V-CATIII – EMC as per EN61326-1
Environment Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C
Mechanical specifications Dimensions (L x D x H): 295 x 295 x 95 mm – Weight: 1.85 kg
Warranty 3 years
*60,000 counts
State at Delivery & References Accessories
MX 5006 multimeter delivered with EU mains power cable, MX 5060 multimeter delivered with EU mains power cable, SX-DMM software for bench-top multimeters > SX-DMM2
1.5 m red straight/straight cable, 1.5 m black straight/straight 1.5 m red straight/straight cable, 1.5 m black straight/straight Set of 2 x BNC/banana leads with rear connection > AG1066-Z
cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe,
operating manual on CD and start-up guide on paper
> MX5006
cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe,
operating manual on CD, start-up guide on paper and remote
programming manual > MX5060
Calibration kit
K thermocouple with adapter
> P01196770
> P01102107Z Simple and effective for your laboratories…
Replacement parts
1.5 m mains power cable > AG0416 l Error-free current measurement up to 10 A thanks to the single A terminal
** MX5006-110 and MX5060-110 versions available on request 1000 V 11 A fuse (x5) > P01297092
1.80 m USB A/B cable > P01295293 l TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth
l Measurement stability with the VLowZ calibre which eliminates spurious voltages
For assistance and ordering
l Measurement stability on variable speed drives with the 300 Hz PWM filter
l Recording and monitoring of the signed Min, Max and Peak values
FRANCE UNITED KINGDOM MIDDLE EAST
Chauvin Arnoux Chauvin Arnoux Ltd Chauvin Arnoux Middle East l Compliance with IEC 61010 1000 V CAT III double insulation, optimized safety
190, rue Championnet Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk P.O. BOX 60-154
75876 PARIS Cedex 18 Dewsbury, West Yorkshire - WF12 7TH 1241 2020 JAL EL DIB - LEBANON
Tel: +33 1 44 85 44 38 Tel: +44 1924 460 494 Tel: +961 1 890 425
Fax: +33 1 46 27 95 59 Fax: +44 1924 455 328 Fax: +961 1 890 424
[email protected] [email protected] [email protected]
www.chauvin-arnoux.fr www.chauvin-arnoux.com www.chauvin-arnoux.com
MX 5006-5060_VGB_MTX Compact F 18/10/13 09:51 Page3
Designed for operation in total safety, the MX 5006 & MX 5060 TRMS multimeters can be used for a wide variety of applications in the electrical
engineering and electronics sectors. With their measurement ranges and the multiple possible combinations, they are particularly versatile.
600 V CAT IV & 1,000 V CAT III electrical engineering applications
Due to their high level of electrical safety, the MX 5006 and MX 5060 can be used for multiple
The table below shows all the functions which you can apply (or not) to the measurements in order to broaden their scope. applications:
➢ Measurements on household appliances, power sockets, handheld tools and similar equipment.
➢ Measurements on switchboards, circuit-breakers, disconnectors, junction boxes, etc.
Measurement type / Functions Max Peak ± ΔREL Range HOLD PWM
Min Auto Manual filter ➢ Measurements on electrical equipment or other industrial appliances connected to the fixed
VLowZ voltage installation.
AC voltage l l l In ΔREL l l l l ➢ And even measurements on equipment installed upstream of the main circuit-breaker for a building.
AC+DC voltage mode only
Current (A)
Voltage VDC
l l l l l l
Current ADC
Voltage 60 mVDC l l l l l l
Voltage 60 mVAC
l l l l l l
Voltage 60 mVAC+DC
Temperature l l In ΔREL l l l Applications on variable speed drives
Resistance l l mode only l l l
The MX 5006 & MX 5060 both offer the main
Capacitance l l l l l
functions required for measurements on
Frequency l l l l
variable speed drives.
Period 1/F l l
Continuity l ➢ VLowZ low impedance to avoid the problem of "spurious" voltages.
PWM
Diode test l l ➢ A 4th-order low-pass filter (300 Hz cut-off frequency) for stable measurements by
eliminating the noise usually present on PWM variable speed drives.
Ergonomics
These laboratory multimeters are stackable, but are also equipped with a multi-directional stand. Designed on the basis of Transflective LCD
technology, their large 16 mm display is exceptionally easy to read. As a result, the MX 5060 offers 60,000 measurement counts with a double
backlit display and a bargraph with central zero. Example: voltage measurement on a variable speed drive
Recording
Installed on a PC, the SX-DMM2 software can be used to process the measurements. It provides time/date-
stamped recordings of the values measured and displays the signal on the PC. All the data processed in
this way can be transferred into a spreadsheet very simply.
Bench-top Multimeters
TECHNICAL SPECIFICATIONS MX 5060 * MX 5006
DC, AC and AC+DC voltages
Range 60 mV* 600 mV 6V 60 V 600 V 1000 V 6,000 and 60,000 counts
Resolution* 0.001 mV 0.01 mV 0.0001 V 0.001 V 0.01 V 0.1 V
DC accuracy 0.05% 0.09%
AC and AC+DC bandwidth
AC ans AC+DC basic accuracy 0.5%
100 kHz
0.8%
MX 5006
VLowZ AC basic accuracy (520 kΩ) 0.5% 1.2%
DC, AC and AC+DC current
Range 6000 µA 60 mA 600 mA 6A 10 A / 20 A (30 s max)
MX 5060
Resolution* 0.1 µA 0.001 mA 0.01 mA 0.0001 A 0.001 A
DC accuracy 0.8%
AC and AC+DC bandwidth 20 kHz 10 kHz
AC and AC+DC accuracy 1%
Frequency
Frequency range 60 Hz 600 Hz 6 kHz 60 kHz
Resolution* 0.01 Hz 0.1 Hz 1 Hz 10 Hz
Resistance and continuity
Range 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 60 MΩ
Resolution* 0.01 Ω 0.1 kΩ 0.001 kΩ 0.01 kΩ 0.0001 MΩ 0.001 MΩ
Basic accuracy 0.2% 0.4%
Protection 1,000 V electronic protection
Audible continuity detection 600 Ω SIGNAL <30 Ω +/-5 Ω < 5V
Diode test
Voltage measurement 3 V, resolution 1 mV + Buzzer <40 mV ±10 mV
Capacitances
Range 6 nF 60 nF 600 nF 6 µF 60 µF 600 µF 6 mF 60 mF
Resolution 0.001 nF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1 µF 10 µF
K thermocouple temperature
Operating range -200 °C to +1,200 °C
Accuracy / Resolution 0.5% R / 0.1 °C
Other functions
Min/Max/Peak ± On all positions measured
ΔREL MEM relative value on secondary display subtracted from the measured value on the main display
PWM filter 4th-order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors
Central Zero VDC and IDC with central zero
USB communication With SX-DMM2 software – SCPI commands
AD.COM - Code : 906211382 - Ed.1 - 09/2013 - Characteristics subject to modifications according to technological developments.
Measurement rate and bargraph 5 measurements per second and 61-segment bargraph for analogue function
General specifications
Display type Transflective LCD with backlighting, broadened viewing angle and 16 mm digits
60,000-count* or 6,000-count double display
PC interfaces USB type B connector – SX-DMM2 software
Mains power supply Universal 230 V / 47-63 Hz / removable mains lead and 110V** version < 2 VA
Safety / EMC Safety as per IEC61010-1 (2001) 1000V-CATIII – EMC as per EN61326-1
Environment Storage: -20 °C to +70 °C – Operation: 0 °C to +40 °C
Mechanical specifications Dimensions (L x D x H): 295 x 295 x 95 mm – Weight: 1.85 kg
Warranty 3 years
*60,000 counts
State at Delivery & References Accessories
MX 5006 multimeter delivered with EU mains power cable, MX 5060 multimeter delivered with EU mains power cable, SX-DMM software for bench-top multimeters > SX-DMM2
1.5 m red straight/straight cable, 1.5 m black straight/straight 1.5 m red straight/straight cable, 1.5 m black straight/straight Set of 2 x BNC/banana leads with rear connection > AG1066-Z
cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe,
operating manual on CD and start-up guide on paper
> MX5006
cable, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe,
operating manual on CD, start-up guide on paper and remote
programming manual > MX5060
Calibration kit
K thermocouple with adapter
> P01196770
> P01102107Z Simple and effective for your laboratories…
Replacement parts
1.5 m mains power cable > AG0416 l Error-free current measurement up to 10 A thanks to the single A terminal
** MX5006-110 and MX5060-110 versions available on request 1000 V 11 A fuse (x5) > P01297092
1.80 m USB A/B cable > P01295293 l TRMS AC+DC and up to 60,000 counts displayed with 100 kHz bandwidth
l Measurement stability with the VLowZ calibre which eliminates spurious voltages
For assistance and ordering
l Measurement stability on variable speed drives with the 300 Hz PWM filter
l Recording and monitoring of the signed Min, Max and Peak values
FRANCE UNITED KINGDOM MIDDLE EAST
Chauvin Arnoux Chauvin Arnoux Ltd Chauvin Arnoux Middle East l Compliance with IEC 61010 1000 V CAT III double insulation, optimized safety
190, rue Championnet Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk P.O. BOX 60-154
75876 PARIS Cedex 18 Dewsbury, West Yorkshire - WF12 7TH 1241 2020 JAL EL DIB - LEBANON
Tel: +33 1 44 85 44 38 Tel: +44 1924 460 494 Tel: +961 1 890 425
Fax: +33 1 46 27 95 59 Fax: +44 1924 455 328 Fax: +961 1 890 424
[email protected] [email protected] [email protected]