Network 1:: 11 y 12 2 FC LAD Automatic

This document contains the summary of a Totally Integrated Automation Portal project. It includes 8 networks that control inputs, outputs, timers and flags related to a car entrance system with a light and plume. The networks control the timer for the light and plume activation, detect when a car enters or exits, and turn on the corresponding light and plume using internal flags and timers.

Uploaded by

a01254314
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
31 views2 pages

Network 1:: 11 y 12 2 FC LAD Automatic

This document contains the summary of a Totally Integrated Automation Portal project. It includes 8 networks that control inputs, outputs, timers and flags related to a car entrance system with a light and plume. The networks control the timer for the light and plume activation, detect when a car enters or exits, and turn on the corresponding light and plume using internal flags and timers.

Uploaded by

a01254314
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Totally Integrated

Automation Portal

11 y 12 [FC2]
11 y 12 Properties
General
Name 11 y 12 Number 2 Type FC Language LAD
Numbering Automatic
Information
Title Author Comment Family
Version 0.1 User-defined ID

Name Data type Offset Default value Comment


Input
Output
InOut
Temp
Constant
Return
11 y 12 Void

Network 1:

%I4.0 %M4.6 %Q4.7


"ENTRADA_CARRO" "PARO" "HORA"

%Q4.7
"HORA"

Network 2:

%DB1
"IEC_Timer_0_DB"
TON
%Q4.7 Time %M4.6
"HORA" "PARO"
INQ
T#60sPTETT#0MS

Network 3:

%DB1.DBD8
"IEC_Timer_0_ DB".ET
%Q4.3
>
"Led_time"
Time
T#40s

Network 4:

%DB1.DBD8
"IEC_Timer_0_ DB".ET
%M4.4
>
"Led_time_60"
Time
T#50S

Network 5:

%I4.0 %M4.0
"ENTRADA_CARRO" "M_PLUMA"
S

%I4.1
"SALIDA_CARRO"

Network 6:
Totally Integrated
Automation Portal

%M4.0 %Q4.2
"M_PLUMA" "LEDPLUMA"

Network 7:

%DB3
"PLUMA"
TON
%M4.0 Time %M4.1
"M_PLUMA" "M_PLUMA2"
INQ
T#4SPTETT#0MS

Network 8:

%M4.1 %M4.0
"M_PLUMA2" "M_PLUMA"
R