02 190 0012 MK 062

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

DATA SHEET

MP FLASH GAS COMPRESSOR


(API Std 617, 7th Edition)
GENERAL
1 NOTE: INFORMATION TO BE COMPLETED: BY PURCHASER BY MANUFACTURER
2 APPLICABLE TO: PROPOSAL PURCHASE AS BUILT
3 CLIENT: CONFIDENTIAL PROJECT: CONFIDENTIAL JOB NO.: 2190001
4 ITEM NO.: C2374 NO. REQUIRED: 1
5 SITE: OFFSHORE FPSO - TROPICAL SE ASIA MODEL NO.: VTA
6 SERVICE: GAS COMPRESSION SERIAL NO.: VTA
7 CONTINUOUS INTERMITTENT STAND BY DRIVER TYPE (1-3.1.1) ELECTRIC MOTOR
8 MFR. MODEL: DRIVER ITEM NO.

9 OPERATING CONDITIONS
10 Start Of HP LP
11 (ALL DATA ON TOTAL FLOW BASIS) Filed Life Operation Operation
12
13 YEAR 2013 2015 2020
14 GAS HANDLED (ALSO SEE PAGE ) HYDROCARBON VAPOUR
15 GAS PROPERTIES (1-2.1.1.4) 1 X 100% 1 X 100% 1 X 100%
16 Flow MMSCFD (101.3 kPa.a & 20°C DRY) 16.7 7.8 2.2
17 WEIGHT FLOW, kg/h (WET) (DRY) 20,780 9,080 2491
18 INLET CONDITIONS
19 PRESSURE (Barg) 23.70 23.70 18.10
20 TEMPERATURE (°C) 33.5 29.4 26.1
21 RELATIVE HUMIDITY (%) - - -
22 MOLECULAR WEIGHT (M) 25 23.4 23.0
23 Cp/Cv ( K1 ) OR (KAVG ) 1.335 1.344 1.32
24 COMPRESSIBILITY (Z1 ) OR (ZAVG ) 0.884 0.897 0.921
3
25 INLET VOLUME, m /h (WET / DRY) 758 355 157
26 DISCHARGE CONDITIONS
27 PRESSURE (Barg) 64.00 64.00 44.00
28 TEMPERATURE (°C) 108.6 107.7 95.3
29 Cp/Cv (K2 ) OR (KAVG ) 1.343 1.342 1.312
30 COMPRESSIBILITY (Z2 ) OR (ZAVG ) 0.872 0.892 0.914
31 GAS POWER REQUIRED (kW g) (NOTE 1) 722.9 341.7 85.2
32 TRAIN kW b REQUIRED
33 DRIVER kW d REQUIRED, INCL. EXT. LOSSES (GEAR, ETC.)
34 SPEED (RPM)
35 TURNDOWN (%)
36 POLYTROPIC HEAD (N.m/kg)
37 POLYTROPIC EFFICIENCY (%) 77.09 77.16 76.95
38 CERTIFIED POINT
39 PERFORMANCE CURVE NUMBER
40 PROCESS CONTROL (1-3.4.2.1)
41 METHOD SUCTION THROTTLING VARIABLE INLET SPEED VARIATION DISCHARG COOLED BYPASS
42 FROM kPa.a GUIDE VANES FROM % BLOWOFF FR
43 TO kPa.a (2-3.4.2.2) TO % TO
40 SIGNAL SOURCE (1-3.4.2.1)
41 TYPE ELECTRONIC PNEUMATIC OTHER
42 RANGE mA kPa.a
43 ANTI-SURGE SYSTEM (1-3.4.2.2)
44
45 REMARKS: NOTE 1 - C2374 & C2373 ARE DRIVEN BY THE SAME MOTOR
46 2. MUST COMPLY WITH NACE MR0175
47
48
49
50
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 1 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 OPERATING CONDITIONS (Continued) (1-2.1.1.1) (1-3.1.2) (1-3.1.3)


2 GAS ANALYSIS: Start Of HP LP
3 MOL % Field Life Operation Operation REMARKS:
4 MW 2013 2015 2020
5 AIR 28.966 - - -
6 OXYGEN 32.000 - - -
7 NITROGEN 28.016 0.05 0.05 0.04
8 WATER VAPOR 18.016 0.23 0.18 0.19
9 CARBON MONOXIDE 28.010 - - -
10 CARBON DIOXIDE 44.010 3.31 3.87 4.14
11 HYDROGEN SULFIDE 34.076 - - - (1-2.2.1.6)
12 HYDROGEN 2.016 - - - (1-2.2.1.9)
13 METHANE 16.042 67.20 72.39 73.32
14 ETHYLENE 28.052 - - -
15 ETHANE 30.068 11.12 9.9 10.26
16 PROPYLENE 42.078 - - -
17 PROPANE 44.094 10.08 7.91 7.43
18 I-BUTANE 58.120 2.65 1.83 1.39
19 n-BUTANE 58.120 3.43 2.30 1.79
20 I-PENTANE 72.146 0.94 0.68 0.59
21 n-PENTANE 72.146 0.61 0.45 0.45
22 HEXANE 86.172 0.31 0.29 0.32
23 C7-C9 106.813 0.04 0.06 0.08 (1-2.2.1.3)
24
25 TOTAL
26 AVG. MOL. WT.
27 LOCATION: (1-2.1.8) NOISE SPECIFICATIONS: (1-2.1.9)
28 INDOOR OUTDOOR GRADE APPLICABLE TO MACHINE:
29 HEATED UNDER ROOF MEZZANINE SEE SPECIFICATION
30 UNHEATED PARTIAL SIDES APPLICABLE TO NEIGHBORHOOD:
31 ELEC. AREA CLASSIFICATION (1-2.1.14) CL GR DIV SEE SPECIFICATION
32 ACOUSTIC HOUSING: YES NO
33 SITE DATA (1-2.1.8)
34 ELEVATION m BAROMETER kPa.a APPLICABLE SPECIFICATIONS:
35 RANGE OF AMBIENT TEMPS: API 617, CENTRIFUGAL COMPR. FOR GEN. REFINERY SERV.
36 DRY BULB WET BULB VENDOR HAVING UNIT RESPONSIBILITY (1-1.5.53) (1-1.8) (1-2.1.3)
37 NORMAL °C
38 MAXIMUM °C GOVERNING SPECIFICATION (IF DIFFERENT)
39 MINIMUM °C
40 °C
41 UNUSUAL CONDITIONS: DUST FUMES PAINTING:
42 °C MANUFACTURER'S STD.
43 OTHER (1-2.1.8) OTHER
44
45 COPPER AND COPPER ALLOYS PROHIBITED (1-2.2.1.14) SHIPMENT: (4.4)
46 COATING: (1-2.2.1.16) DOMESTIC EXPORT EXPORT BOXING REQ'D.
47 ROTATING COMPONENTS OUTDOOR STORAGE MORE THAN 6 MONTHS (1-4.4.1) MO
48 STATIONARY COMPONENTS SPARE ROTOR ASSEMBLY PACKAGED FOR (1-4.4.3.10)
49 REMARKS: HORIZONTAL STORAGE VERTICAL STORAGE
50
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 2 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 CONSTRUCTION FEATURES
2 SPEEDS: INTERMEDIATE MAIN PROCESS CONNECTIONS (2-2.4.5)
3 MAX. CONT. RPM TRIP RPM DISCH. PRESSURE (kPa.g): MAX MIN
4 MAX. TIP SPEEDS m.s-1 @ 100% SPEED INLET PRESSURE (kPa.g): MAX MIN
5 m.s-1 @ MAX. CONT. SPEED GUIDE VANES
6 LATERAL CRITICAL SPEEDS (DAMPED) MATERIAL
7 FIRST CRITICAL RPM MODE NUMBER OF AXIAL BLADE ROWS
8 SECOND CRITICAL RPM MODE NUMBER OF ADJUSTABLE ROWS
9 THIRD CRITICAL RPM MODE NO. VANES GUIDE VANE
10 FOURTH CRITICAL RPM MODE IMPELLERS:
11 LATERAL ANALYSIS ADDITIONAL REQUIREMENTS (1-2.6.2.14) NO. DIAMETERS
12 TRAIN LATERAL ANALYSIS REQUIRED (1-2.6.2.6) NO. VANES EA. IMPELLER
13 TRAIN TORSIONAL ANALYSIS REQUIRED (1-2.6.7.1) TYPE (OPEN, ENCLOSED, ETC.)
14 TORSIONAL CRITICAL SPEEDS: TYPE FABRICATION
15 FIRST CRITICAL RPM MATERIAL
16 SECOND CRITICAL RPM MIN. YIELD STRENGTH (MPa)
17 THIRD CRITICAL RPM HARDNESS: (Rc) (BRINNEL) MAX. MIN.
18 FOURTH CRITICAL RPM SMALLEST TIP INTERNAL WIDTH (mm)
19 LIST OF TRAIN UNDESIRABLE SPEEDS (1-2.6.1.4) MAX. MACH. NO. @ IMPELLER EYE
20 STABILITY ANALYSIS (1-2.6.5) MAX. IMPELLER HEAD @ 100% SPEED (N.m/kg)
21 VIBRATION: SHAFT:
22 ALLOWABLE TEST LEVEL μ ONE PIECE BUILT UP
23 (PEAK TO PEAK) MATERIAL
24 NAMEPLATE (2-2.11.2) DIA @ IMPELLERS (mm) DIA @ COUPLING (mm)
25 US CUSTOMARY METRIC SHAFT END: TAPERED CYLINDRICAL
26 ROTATION, VIEWED FROM DRIVEN END CW CCW SPLINED INTEGRAL FLANGE
27 MATERIALS INSPECTION REQUIREMENTS (1-4.2.2.1) MIN. YIELD STRENGTH (MPa)
28 RADIOGRAPHY REQUIRED FOR SHAFT HARDNESS (BNH) (Rc)
29 ULTRASONIC REQUIRED FOR MAX. TORQUE CAPABILITY (N.m)
30 MAGNETIC PARTICLE REQUIRED FOR BALANCE PISTON:
31 LIQUID PENETRANT REQUIRED FOR MATERIAL AREA mm2
32 LOW TEMPERATURE (1-2.2.1.15.3) FIXATION METHOD
33 MDMT (°C) AT CONCURRENT PRESS. NORMAL CLEARANCE (mm)
34 OTHER TRAIN COMPONENTS (1-2.2.1.15.2) FLOW WITH NORMAL CLEARANCE (kg/h)
35 CASING: FLOW WITH 2X NORMAL CLEARANCE (kg/h)
36 MODEL PRESS. CONN. BAL LINE DOWNSTREAM (2-2.5.4.3)

37 CASING SPLIT SHAFT SLEEVES:


38 MATERIAL AT INTERSTG. CLOSE MAT'L.
39 THICKNESS (mm) CORR. ALLOW. (mm) CLEARANCE POINTS
40 MAX. ALLOWABLE PRESS kPa.g AT SHAFT SEALS MAT'L.
41 TEST PRESS (kPa.g):HELIUM HYDRO ACCESSIBLE (2-2.8.3)
42 MAX. ALLOWABLE TEMPERATURE (°C) ROTOR
43 MAX OPER. TEMP. °C MIN. OPER. TEMP. °C DISASSEMBLY AND REASSEMBLY (2-2.6.8.2.1.1)
44 MAX CASING CAPACITY (Nm3/hr) AT SPEED BALANCING (1-2.6.8.3)
45 SYSTEM RELIEF VALVE SET PT. (2-2.3.1.1) kPa.g SEQUENTIAL LOW SPEED BAL. PREC. AT SPEED BAL. (1-2.6.8.6)
46 QC OF INACCESSIBLE WELDS (1-2.3.1.11.2) RESIDUAL BALANCE CHECK (1-2.6.8.7)
47 DIAPHRAGMS: LABYRINTHS:
48 MATERIAL INTERSTAGE
49 AXIALLY SPLIT: YES NO (2-2.4.8) TYPE MATERIAL
50 BALANCE PISTON
51 TYPE MATERIAL
52 REMARKS:
53
54
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 3 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 CONSTRUCTION FEATURES (CONTINUED)


2 SHAFT SEALS: BUFFER GAS CONTROL SYSTEM SCHEMATIC BY VENDOR
3 SEAL TYPE (1-2.8.1.3) PRESSURIZING GAS FOR SUBATMOSPHERIC SEALS (1-2.8.2.4)
4 SETTLING OUT PRESSURE (1-2.8.1.3) (kPa.g) EDUCTOR INJECTION (1-2.8.2.3)
5 MIN. SEALING PRESSURE (kPa.g) SEAL MANUFACTURER
6 SUPPLEMENTAL DEVICE REQUIRED FOR CONTACT LEAKAGE TO PROCESS (GAL/DAY/SEAL)
7 SEALS (1-2.8.3.4) TYPE BUFFER GAS REQUIRED FOR:
8 TYPE BUFFER GAS (1-2.8.1.5) AIR RUN-IN OTHER
9 PRESSURE (1-2.8.1.6) kPa.g FLOW (PER SEAL):
10 FLOW RATE kg/MIN NORM: kg/MIN @ kPa ΔP
11 FILTRATION MAX.: kg/MIN @ kPa ΔP
12 BUFFER GAS SYSTEM REQUIRED (2-2.8.1.5) BEARING HOUSING CONSTRUCTION:
13 MANIFOLD (1-3.5.1.4) TYPE (SEPARATE, INTEGRAL) SPLIT
14 METHOD OF CONTROL (1-2.8.1.5) MATERIAL

15
16 REMARKS:
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 4 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 CONSTRUCTION FEATURES (CONTINUED)


2 BEARINGS AND BEARING HOUSINGS
3 MAGNETIC BEARINGS (2-2.7.1.1.2)
4 RADIAL THRUST NON-THRUST THRUST ACTIVE INACTIVE
5 TYPE TYPE
6 MANUFACTURER MANUFACTURER
7 LENGTH (mm) UNIT LOADING (MAX. kPa)
8 SHAFT DIA. (mm) UNIT LOAD (ULT.) (kPa)
9 UNIT LOAD (ACT/ALLOW) AREA (mm2)
10 BASE MATERIAL NO. PADS
11 BABBIT THICKNESS (mm) PIVOT: CTR/OFFSET, %
12 NO. PADS PAD BASE MATERIAL
13 LOAD: B'TWN/ON PAD COPPER BACKED (2-2.7.3.7)
14 PIVOT: CTR/OFFSET, % LUBRICATION FLOODED DIRECTED (2-2.7.3.6)
15 PAD MATERIAL (2-2.7.2.2) (2-2.7.2.3) THRUST COLLAR INTEGRAL REPLACEABLE
16 BEARING SPAN mm MATERIAL
17 SIZING CRITERION (2-2.7.3.3)
18 BEARING TEMPERATURE DETECTORS (2-3.4.7) VIBRATION DETECTORS: SEE ATTACHED API 670 DATA SHEET
19 SEE ATTACHED API 670 DATA SHEET TYPE MODEL
20 THERMOCOUPLES TYPE MFR
21 RESISTANCE TEMP DETECTORS NO. AT EA SHAFT BEARING TOTAL NO.
22 RESISTANCE MAT'L OHMS OSCILLATOR-DETECTORS SUPPLIED BY
23 ALARM TEMPERATURE (°C) MFR MODEL
24 SHUTDOWN TEMPERATURE (°C) MONITOR SUPPLIED BY (2-3.4.7.2)
25 PROVISION FOR LOCAL DISCONNECT (1-2.7.4.6) LOCATION ENCLOSURE
26 LOCATION-JOURNAL BEARING MFR MODEL
27 NO. EA PAD EVERY OTHER PAD /BRG SCALE RGE ALARM SET @ μ
28 OTHER SHTDWN: SET @ μ TIME DELAY SEC
29 LOCATION-THRUST BRG CASING VIBRATION TRANSDUCERS (2-3.4.7.5)
30 NO. EA PAD EVERY OTHER PAD /BRG CASING VIBRATION MONITORS (2-3.4.7.6)
31 OTHER AXIAL POSITION DETECTOR SEE ATTACHED API 670 DATA SHEET
32 NO. (INACT) EA PAD EVERY OTHER PAD /BRG TYPE MODEL
33 OTHER MFR NO. REQUIRED
34 LOCAL DISCONNECTION (1-2.7.4.6) OSCILLATOR-DEMODULATOR SUPPLIED BY
35 MONITOR SUPPLIED BY (2-3.4.7.4) MFR MODEL
36 LOCATION ENCLOSURE MONITOR SUPPLIED BY (2-3.4.7.2)
37 MFR. MODEL LOCATION ENCLOSURE
38 SCALE RG. ALARM SET @ °C MFR MODEL
39 SHTDWN SET @ °C TIME DELAY SCALE RGE ALARM SET @ MILS
40 SHTDWN: SET @ MILS TIME DELAY SEC
41 KEY PHASOR REQUIRED
42 COMPRESSOR GEAR HS GEAR LS
43 CASING CONNECTIONS (1-2.3.2.2)
44 ANSI/ASME MATING
45 CONNECTION B16.1; B16.5; FACING ORIENTATION FLANGED FLG & GAS
46 B16.42; B16.47 BORE OR GASKET VELOCITY
47 SERIES A, B; STUDDED BY VENDOR m.s-1
48 ISO 7005-1, -2;OTHER (1-2.3.2.2.1) (1-2.3.2.2.7)
49 INLET
50 DISCHARGE

51
52
53
54
55 BOROSCOPIC INSPECTION PORTS (2-2.3.2.4)
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 5 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 Other Connections
2 Service No. Size Type Remarks
3 Lube - Oil inlet
4 Lube - Oil Outlet
5 Seal - Oil Inlet
6 Seal - Oil Outlet
7 Seal - Gas Inlet
8 Seal - Gas Outlet
9 Casing Drains
10 Stage Drains
11 Pressure
12 Temperature
13 Solvent Injection
14 Purge for:
15 Brg. housing
16 Btwn brg & seal
17 Btwn seal & gas
18 Individual Stage Drains Required (1-2.3.2.1.7)
19 Drains Valved Blinded
20 Drains Valved, Blinded Manifolded
21 LUBRICATION AND SEALING SYSTEMS (1-2.10) (1-3.5.1.2)
22 SEE ATTACHED API 614 DATA SHEET
23 SEPARATE COMBINED (2-2.10.1)
24 INTEGRAL OIL RESERVOIR (1-3.3.2.11)
25 OIL TYPE (2-2.10.2)
26 ACCESSORIES
27 COUPLING AND GUARDS (3.2)
28 NOTE: SEE ROTATING ELEMENTS - SHAFT ENDS
29 SEE ATTACHED API 671 DATA SHEET KEYLESS HYDRAULIC KEYED FLANGED OTHER
30 COUPLINGS FURNISHED BY
31 MANUFACTURER TYPE MODEL
32 COUPLING GUARD FURNISHED BY
33 TYPE: FULLY ENCLOSED SEMI-OPEN OTHER
34
35 COUPLING DETAILS PLUG AND RING GAUGES (1-3.2.5)
36 MAX OD mm LUBRICATION REQUIREMENTS:
37 HUB WEIGHT kg NON-LUBE CONT. OIL LUBE
38 SPACER LENGTH mm OTHER:
39 SPACER WEIGHT kg QUANTITY PER HUB kg.s -1
40 MOUNTING PLATES (1-3.3)
41 BASEPLATES FURNISHED BY (1-3.3.2.1) SOLEPLATES FURNISHED BY (1-3.3.3.1)
42 COMPRESSOR ONLY DRIVER GEAR THICKNESS mm
43 OTHER SUB SOLE PLATES REQUIRED (1-3.3.3.1.5)
44 NONSKID DECKING (1-3.3.2.4 SLOPED DECK (1-3.3.2.4.1)
45 LEVELING PADS OR TARGETS (1-3.3.2.6) STAINLESS STEEL SHIM THICKNESS mm
46 COLUMN MOUNTING (1-3.3.2.5) COMPRESSOR
47 SUB-SOLE PLATES REQUIRED (1-3.3.2.10)
48 STAINLESS STEEL SHIM THICKNESS mm COUNTER BORE ANCHOR BOLT HOLES (1-3.3.3.1.2)
49 MACHINED MOUNTING PADS REQUIRED (1-3.3.2.9)
50

51 REMARKS:
1
52
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 6 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)

1 UTILITIES
2 UTILITY CONDITIONS: MANUALS
3 STEAM: DRIVERS DRAFT MANUAL FOR REVIEW (1-5.3.5.1.2)
4 INLET MIN kPa.g °C TECHNICAL DATA MANUAL (1-5.3.5)
5 NORM kPa.g °C MISCELLANEOUS
6 MAX kPa.g °C RECOMMENDED STRAIGHT RUN OF PIPE DIAMETERS
7 EXH. MIN kPa.g °C BEFORE SUCTION
8 NORM kPa.g °C COMPRESSOR TO BE SUITABLE FOR FIELD RUN IN
9 MAX kPa.g °C ON AIR (1-2.1.16)
10 ELECTRICITY: PROVISION FOR LIQUID INJECTION (1-2.1.10)
11 DRIVERS CONTROL SHUTDOWN INJECTION MANIFOLD (2-3.5.1.2)
12 VOLTAGE VENDOR'S REVIEW & COMMENTS ON PURCHASER'S
13 HERTZ CONTROL SYSTEMS (1-3.4.1.1)
14 PHASE SHOP FITUP OF VENDOR PROCESS PIPING (1-4.4.3.11)
15 REDUCED VOLTAGE START (1-3.1.6) WELDING HARDNESS TESTING (1-4.2.1.5)
16 NO. OF STARTS (1-2.6.7.6.4) DESIGN AUDIT (1-5.1.4)
17 INSTRUMENT AIR: BALANCE PISTON ΔP (1-5.3.2.15)
18 MAX PRESS kPa.g MIN PRESS kPa.g PROVIDE TAIL END SCHEDULES (1-2.1.13)
19
20 SHOP INSPECTION AND TESTS: (1-4.1.4) VENDOR'S REPRESENTATIVE SHALL (2.1.13)
21 (SEE INSPECTOR'S CHECKLIST) REQ'D WIT/OBV OBSERVE FLANGE PARTING
22 HYDROSTATIC (1-4.3.2) CHECK ALIGNMENT AT TEMPERATURE
23 IMPELLER OVERSPEED (1-4.3.3) BE PRESENT AT INITIAL ALIGNMENT
24 MECHANICAL RUN (1-4.3.6) WEIGHTS (kg):
25 CONTRACT COUPLING IDLING ADAPTOR(S) COMPRESSOR GEAR DRIVER BASE
26 CONTRACT PROBES SHOP PROBES ROTORS: COMPRESSOR DRIVER GEAR
27 PURCHASE VIB. EQUIPMENT (2-4.3.1.1.10) COMPRESSOR UPPER CASE
28 VARY LUBE & SEAL OIL PRESSURES MAX. FOR MAINTENANCE (IDENTIFY)
29 AND TEMPERATURES (1-4.3.6.1.5) TOTAL SHIPPING WEIGHT
30 POLAR FORM VIB DATA (1-4.3.6.1.2)
31 TAPE RECORD VIB DATA (1-4.3.6.1.3) SPACE REQUIREMENTS (mm)
32 SHAFT END SEAL INSP (1-4.3.6.2.2) COMPLETE UNIT: L W H
33 GAS LEAK TEST DISCH PRESS (2-4.3.2.3)
34 POST TEST INTERNAL INSP (1-4.3.8.5) REMARKS:
35 BEFORE GAS LEAKAGE TEST
36 AFTER GAS LEAKAGE TEST
37 PERFORMANCE TEST(GAS)(AIR)(2-4.3.3.1.1)
38 COMPLETE UNIT TEST (2-4.3.3..2)
39 TANDEM TEST (2-4.3.3.3)
40 GEAR TEST (2-4.3.3.4)
41 HELIUM LEAK TEST (1-4.3.8.2)
42 SOUND LEVEL TEST (1-4.3.8.3)
43 AUX. EQUIPMENT TEST (1-4.3.8.4)
44 FULL LOAD / SPEED / PRESS TEST (1-4.3.8.6)
45 HYDRAULIC COUPLING INSP (1-4.3.8.7)
46 SPARE PARTS TEST (1-4.3.8.8)
47 INSPECTOR'S CHECKLIST COMPLIANCE (1-4.1.6)
48 GAS SEAL TEST VENDOR SHOP (1-4.3.5)
49
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 7 of 8 Rev. B1
DATA SHEET
MP FLASH GAS COMPRESSOR
(API Std 617, 7th Edition)
GENERAL
1
2 REMARKS:
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
40
41
42
43
44
45
46
47
48
49
50
Project Document Number
CONFIDENTIAL 02-190-0012-MK-062
Page 8 of 8 Rev. B1

You might also like