AFI Data Sheet Acoustical Ceiling Panels ACP No Pix
AFI Data Sheet Acoustical Ceiling Panels ACP No Pix
AFI Data Sheet Acoustical Ceiling Panels ACP No Pix
Panels
(ACP)
els
20 7/8 0.68 0.81 0.68 0.78 0.85 0.80 0.80 Alkalinity (ASTM C871) AFICO Acoustical Ceiling Panels have excellent
r)
an
ge
gP
an
pH 9 sound absorption characteristics. This is especially
ilin
H
25 1 0.77 0.82 0.70 0.86 0.90 0.75 0.85
to
rn r
Ce
te r o
ve
rid
(al nge
important for areas such as open offices, schools,
l
ca
at
gle
Non-Fibrous (Shot) Content (ASTM C1335)
tG
38 1½ 0.64 0.88 1.02 0.91 0.84 0.62 0.90
sti
Tie Ha
An
or
ou
pp
stores and shopping centres, with a highly sound
s
ire le
er
ee
Not applicable to glass mineral fiber products
Ac
W tab
Su
et
sT
50 2 0.78 0.92 0.79 1.00 1.03 1.10 0.95
O
rim
jus
ain
IC
absorbent ceiling material.
os
AF
Pe
Ad
Cr
M
Light Reflection (ASTM D523)
Sound Transmission Lossin dB WHITE: LR1 = 30 -60 A Better Ceiling for the Short and Long Term
Octave Band Center Frequencies, Hz The abuse-resistant surface of AFICO Acoustical
Sound Transmission Coefficient (ASTM E90) Ceiling Panels will not chip or fake, even when
Thickness
125 250 500 1000 2000 4000 STC STC: 50 or greater dropped. This means reduced cost for contractors
mm in.
Noise Reduction Coefficient (ASTM E423) and owners, due to less damage during installation
15 5/8 30 42 51 59 62 51 50 and normal maintenance.
NRC: minimum 0.60
20 7/8 33 44 52 60 63 53 52
AFICO Acoustical Ceiling Panels can be wiped clean
25 1 35 45 53 59 63 55 54 with soap and water, so normal surface dust can be
38 1½ 38 47 55 58 63 57 56 removed as needed.
50 2 44 55 63 67 71 71 64 Reduced Energy Costs through Proper
Design
AFICO Acoustical Ceiling Panels have a built-in
thermal resistance (R-Value) of R=0.06m2.°K/W, for
the standard 72 kg/m3 density and 20mm thick
type. AFICO Acoustical Ceiling Panels can also be
back loaded with Blanket Insulation to provide an
additional R-value of up to 6.70m2.°K/W (See Maxi-
mum Back loading).
The AFICO Product Range includes • Acoustical Ceiling Panels • Blanket Insulation Storage
• Board Insulation • Cavity Wall Insulation • Duct Liner • Duct Liner Board • Faced Duct Wrap To avoid moisture in the building construction, AFICO
• HD Series Blanket Insulation • Heavy Density Pipe Insulation • Mechanical Board Insulation insulation products stored outside must be kept dry.
• Pipe Wrap Insulation • Pre-engineered Metal Building Insulation • Quiet Liner
• Quiet Liner Board • Roof Deck Board Insulation • Thermal Insulating Wool We recommend AFICO products to be always stored
in covered and dry areas. AFICO is not liable for
the damage resulting from inadequate utilization,
loading and off-loading and mishandling of its
Call us today for more information &
professional guidance: products.