S+G+4-Footing and Column Schedule

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

FOOTING SCHEDULE (M25:Fe500)


FOOTING DIMENSION FOOTING REINFORCEMENT
FOOTING COLUMN COLUMN FOOTING
BOTTOM TOP
LABEL LABEL SIZE TYPE STEP L B D1 PEDESTAL
ALONG L ALONG W ALONG B ALONG L CONC GRADE ALL RCC WORKS M20
F1 C1 12" x 24" Pad - 8' 8' 24" 8 -T12 T16@6" C/C T16@6" C/C -- --
F2 C1 12" x 24" Pad - 8' 8' 24" 8 -T12 T16@6" C/C T16@6" C/C -- --
REINFORCEMENT Fe 550 GRADE
F3 C1 12" x 24" Pad - 9' 8' 24" 8 -T12 T16@6" C/C T16@6" C/C -- --
REFERENCES (COL. FOOTING LAYOUT) (COLUMN DETAILS)
F4 C1 12" x 24" Pad - 8' 9' 24" 8 -T12 T16@6" C/C T16@6" C/C -- --
F5 C1 12" x 24" Pad - 8' 9' 24" 8 -T12 T16@6" C/C T16@6" C/C -- -- CONSTRUCTION
F6 C1 12" x 24" Pad - 8' 9' 24" 8 -T12 T16@6" C/C T16@6" C/C -- -- MIN CLEAR COVER FOR FOOTING REINFORCEMENT IS 2"
F7 C2 9" x18" Pad - 5'6" 6'6" 24" 6 -T12 T12@6" C/C T12@6" C/C -- --
DOWELLS SHALL BE ANCHORED INTO ROCK BY 12"
F8 C2 9" x18" Pad - 5'6" 6'6" 24" 6 -T12 T12@6" C/C T12@6" C/C -- --
F9 C2 9" x18" Pad - 5'6" 5'6" 24" 6 -T12 T12@6" C/C T12@6" C/C -- --
PROVIDE 20mmØ HOLE FOR 16mmØ ROD & GROUT THE
SAME USING CONBEXTRA GP1 OF M/S FOSROC.
RF C3 9" x18" RAFT - Refer key plan 24" - T12@6" C/C T12@6" C/C T12@6" C/C T12@6" C/C
HOLE SHALL BE FILLED WITH CONBEXTRA GP1 AND ROD
IS INSERTED. EXTRA GROUT MATERIAL IS REUSED
COLUMN SCHEDULE
USE CEMENT MORTAR COVER BLOCKS OF COMP.
STRENGTH EQUAL TO STRUCTURAL CONCRETE (MIN 1:3)
S.NO. COLUMN SIZE REINFORCEMENT
B' X D' (MAIN)
TIES SECTIONS MIX No's HORIZONTAL/ VERTICAL JOINTS IN CONCRETE FOR
FOOTINGS ARE NOT ALLOWED.
SHEAR KEYS SHALL BE PROVIDED AT INTERFACE OF
1 C1 12" X 24" 6-20Ø+6-16Ø 8Ø @ 6" c/c M25 06 FOOTING AND PEDESTAL / COLUMN CONCRETE
6-20Ø
6-16Ø HONEY COMBS IF ANY AND STEEL IS EXPOSED, SHALL BE

UPTO STILT(PARKING) FLOOR


CLOSED WITH POLYMER MODIFIED MORTAR SUBJECT TO
APPROVAL OF EIC
9" X 18" 12-16Ø 8Ø @ 6" c/c M25 02
2 C2
12-16Ø WATER PROOF PLASTERING SHALL BE ½" TH IN CM 1:5.
USE CONPLAST 421 OF M/S FOSROC, WATER PROOFING
ADMIXTURE FOR WATER PROOF PLASTERING.
4 C3 9" X 18" 8-16Ø+ 2-12Ø 8Ø @ 8" c/c
8 -T16
M25 03 REINFORCEMENT
2 -T12
LAP IS NOT PERMITTED IN FOOTING STEEL.
PROVIDE L BENT TO RE-BARS IN FOOTING FOR BEAM
5 C4 9" X 18" 4-16Ø+ 4-12Ø 8Ø @ 8" c/c TYPE 'b1' ONLY
M25 01
GENERAL
4-16Ø DEVELOPMENT LENGTH
4-12Ø OF BARS LAPPING LENGTH IF TOP OF PLINTH AND TOP OF FOOTING ARE SAME,LEAVE
FE550 GRADE
(IN TENSION) DOWELS FOR PLINTH PRIOR TO CASTING OF FOOTING.
DIA OF M-25 DIA OF Lapping 6Ø, INDICATES DIAMETER OF BAR- MILD STEEL
BARS Fe 550 BARS Length T8 INDICATES DIAMETER OF BAR- TORSTEEL OF Fe 550 GRADE
8Ø 19" 8mm 16"
10Ø 10mm
24" 20" 0:000 A3
12Ø 29" 12mm 24"
16Ø 39" 16mm 32"
20Ø 49" 20mm 39"
25Ø 61" 25mm 48"