TCP Ip Modbus Banco de Dados

This document describes a MODBUS TCP/IP data block (DB108) containing parameters for communication via MODBUS TCP/IP protocol. The data block contains structures for read/write parameters, network parameters including IP address and port numbers, as well as initial parameters and remote module ID. It will be used to monitor and control a chiller system via MODBUS TCP/IP.

Uploaded by

carloswmerens
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views1 page

TCP Ip Modbus Banco de Dados

This document describes a MODBUS TCP/IP data block (DB108) containing parameters for communication via MODBUS TCP/IP protocol. The data block contains structures for read/write parameters, network parameters including IP address and port numbers, as well as initial parameters and remote module ID. It will be used to monitor and control a chiller system via MODBUS TCP/IP.

Uploaded by

carloswmerens
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Totally Integrated

Automation Portal

CISTERNA - CHILLER - POÇO_V16_V.1.0 / MONITORAMENTO D'AGUA [CPU 1217C DC/DC/DC] / Program blocks
MODBUS TCP-IP DADOS [DB108]
MODBUS TCP-IP DADOS Properties
General
Name MODBUS TCP-IP DADOS Number 108 Type DB Language DB
Numbering Automatic
Information
Title Author Comment Family
Version 0.1 User-defined ID

MODBUS TCP-IP DADOS


Name Data type Start value Retain Accessible Writ‐ Visible in Setpoint Supervi‐ Comment
from able HMI engi‐ sion
HMI/OPC from neering
UA/Web HMI/
API OPC
UA/
Web
API
Static
PARAMETROS Struct True False False False False
ESCRITA Array[0..7] of True False False False False
Bool
ESCRITA[0] Bool false True False False False False
ESCRITA[1] Bool false True False False False False
ESCRITA[2] Bool false True False False False False
ESCRITA[3] Bool false True False False False False
ESCRITA[4] Bool false True False False False False
ESCRITA[5] Bool false True False False False False
ESCRITA[6] Bool false True False False False False
ESCRITA[7] Bool false True False False False False
LEITURA Array[0..7] of True False False False False
Bool
LEITURA[0] Bool false True False False False False
LEITURA[1] Bool false True False False False False
LEITURA[2] Bool false True False False False False
LEITURA[3] Bool false True False False False False
LEITURA[4] Bool false True False False False False
LEITURA[5] Bool false True False False False False
LEITURA[6] Bool false True False False False False
LEITURA[7] Bool false True False False False False
PARAMETROS REDE Struct True False False False False
HABILITAR Bool false True False False False False
CONNECT TCON_IP_v4 True False False False False
InterfaceId HW_ANY 64 True False False False False HW-identifier of IE-interface submod‐
ule
ID CONN_OUC 90 True False False False False connection reference / identifier
ConnectionType Byte 16#0B True False False False False type of connection: 11=TCP/IP,
19=UDP (17=TCP/IP)
ActiveEstablished Bool TRUE True False False False False active/passive connection establish‐
ment
RemoteAddress IP_V4 True False False False False remote IP address (IPv4)
ADDR Array[1..4] of True False False False False IPv4 address
Byte
ADDR[1] Byte 192 True False False False False IPv4 address
ADDR[2] Byte 168 True False False False False IPv4 address
ADDR[3] Byte 0 True False False False False IPv4 address
ADDR[4] Byte 167 True False False False False IPv4 address
RemotePort UInt 502 True False False False False remote UDP/TCP port number
LocalPort UInt 502 True False False False False local UDP/TCP port number
PARAMETRO INICIAL UDInt 0 True False False False False
ID MODULO REMOTO UDInt 1 True False False False False