T5 RED-LVD EN60065 Report

Download as pdf or txt
Download as pdf or txt
You are on page 1of 59

Dongguan Nore Testing Center Co., Ltd.

Report No.: NTC1711197SV00

Revision History of This Test Report

Report Number Description Issued Date

NTC1711197SV00 Initial Issue 2017-12-14


-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --
-- -- --

Page 2 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Copy of marking plate: (Representative)

Remarks:
1.The above markings are the minimum requirements required by the safety standard. For the final production
samples, the additional markings which do not give rise to misunderstanding may be added.
2.The CE marking and WEEE symbol should be at least 5.0mm and 7.0mm respectively in height.
3.All models are identical to each other except for model number .
4.The address of manufacturer will indicate on its packaging or in a document accompanying the product.
5.The importer information (name and address)should be marked in product when this product import to
European Marketing.

Summary of testing:
From the result of our tests on the submitted samples, we conclude they comply with the requirements of the
standards.

Page 3 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Test item particulars:


Classification of installation and use ............................ : Class II apparatus
Supply Connection ....................................................... : Detachable power cord with plug
Possible test case verdicts:
- test case does not apply to the test object ................ : N (N/A)
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
General remarks:
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.

General product information:


1. The product covered by this report is a Computer multimedia speaker for Audio, Video and similar electronic
apparatus, Class II equipment.

2. In this report, the product is to be used under:


─ Maximum operating temperature: +35°C.
─ Altitude less than 2000m.
─ Indoor used only.
─ Apparatus mass EUT: 10.9Kg

3. All models are identical in circuitry and electrical, mechanical and physical construction, the only differences
are the model names, color of appearance for trading purpose.
Unless otherwise noted, all tests were performed on model T5 to represent the other similar models.

4. All tests were measured under the most severe condition and the load conditions used during testing are:
-- The unit have four signal input modes, "USB" mode, “AUX” mode, “BT” and “FM” mode. Unless other
specified, the testing is conducted under “BT” mode due to larger power consumption.

5. USB only as a signal input port.

Page 4 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

3 GENERAL REQUIREMENTS P
Safety class of the apparatus ...................................: Class II apparatus. P

4 GENERAL TEST CONDITIONS P


4.1.4 Ventilation instructions require the use of the test box The temperature measured
in an open-fronted wooden P
box

5 MARKING AND INSTRUCTIONS P


5.1 General requirements P
Comprehensible and easily discernible Located on enclosure P
Permanent durability against water and petroleum Compliance was checked by
rubbing the marking by hand
spirit
for 15 s with cloth soaked
with water and cloth soaked P
with petroleum spirit, it was
durable and legible after the
test.
5.2 Identification and supply rating P
a) Identification, maker .............................................: See the Copy of marking
P
plate
b) Model number or type reference ..........................: See the Copy of marking
P
plate
c) Class II symbol or Class II with functional earth
P
symbol if applicable ..................................................:
d) Nature of supply ....................................................: (for AC supply) P
e) Rated supply voltage ...........................................: 100-240V~(for AC supply);
P
15Vdc (for internal battery)
f) Mains frequency if safety dependant ...................: 50/60Hz(for AC supply) P
g) Rated current or power consumption for apparatus The apparatus was intended
supplied by supply apparatus for general use, on for connection to an a.c. N
apparatus or in instruction manual ..............: mains supply.
Measured current or power consumption ................: N
Deviation % (max 10%) ...........................................: N
h) Rated current or power consumption for apparat- us
0.5A P
intended for connection to an a.c. mains supply .:
Measured current or power consumption ................: (See appended table 7.1.) P
Measured current or power consumption for
N
Television set ............................................................:
Deviation % (max 10%) ...........................................: Not exceed 10% P
Symbols explained in the user manual Complied P
5.3 Terminals N
a) Earth terminal Class II apparatus. N

Page 5 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

b) Hazardous live terminals No such terminals. N


c) Markings on supply output terminals N

5.4 Caution marking P


a) Use of triangle with exclamation mark P
used in circuit diagram
b) Marking on loudspeaker grille, IEC 60417-5036 No such grille used N
c) User-replaceable coin / button cell battery marking AAA size consumer type
battery used for remote N
control device only.
5.5 Instructions P
5.5.1 Safety relevant information English version user manual
was provided (Version in
other language will be P
provided when submitted for
national approval)
5.5.2 a) Mains powered equipment not exposed to dripping or
The statement is provided in
splashing. Warning concerning objects filled with liquid, P
user’s manual.
etc.
b) Hazardous live terminals, instructions for wiring No live terminals. N
c) Instructions for replacing lithium battery No such batteries provided. N
d) Class I earth connection warning Class II apparatus. N
e) Instructions for multimedia system connection The statement is provided in
P
user’s manual.
f) Special stability warning for attachment of the No special fixed installation
N
apparatus to the floor/wall necessary.
g) Warning: battery exposure to heat Provided in the user manual. P
h) Warning: protective film on CRT face No such device. N
i) Warning: Non-floor standing TV >7kg N
j) Warning: User replaceable coin / button cell battery N

5.5.3 a-b) Disconnect device: plug/coupler or all-pole mains Mains plug or appliance
switch location, accessibility and markings coupler is used as the P
disconnect device
c) Instructions for permanently connected equipment No such equipment N
Marking, signal lamps or similar for completely
No such device. N
disconnection from the mains

6 HAZARDOUS RADIATION P
6.1 Ionizing radiation < 36 pA/kg (0,5 mR/h) No ionizing radiation. N
Ionizing radiation under fault condition N
6.2 Laser radiation, emission limits to IEC 60825-1:2007...: N

Page 6 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Emission limits under fault conditions ......................:


N

6.3 Light emiting diodes (LEDs) according to IEC 62471 Indicating LED on
secondary is inherently
P
exempt group according to
IEC 62471.

7 HEATING UNDER NORMAL OPERATING CONDITIONS P


7.1 General
7.1.1 Temperature rises not exceeding specified values; fuse
(See appended table 7.1) P
links and other protective devices defeated
7.1.2 Temperature rise of accessible parts (See appended table 7.1) P
7.1.3 Temperature rise of parts providing electrical insulation (See appended table 7.1) P
7.1.4 Temperature rise of parts acting as a support or as a
(See appended table 7.1) P
mechanical barrier
7.1.5 Temperature rise of windings (See appended table 7.1) P
7.1.6 Parts not subject to a limit under 7.1.1 to 7.1.4 N
7.2 Softening temperature of insulating material supporting Phenolic materials used for
parts conductively connected to the mains carrying a LF2 and transformer T1
o
current > 0,2 A at least 150 C consider as having softening
N
temperature of 150°C,
no other parts tested
necessary.

8 CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION P


AGAINST ELECTRIC SHOCK
8.1 Conductive parts covered by lacquer, paper, untreated
No such parts N
textile oxide films and beads etc. considered to be bare
8.2 No shock hazard when changing voltage setting device, No such parts to be
N
fuse-links or handling drawers etc. operated by user.
8.3 Insulation of hazardous live parts not provided by No hygroscopic material
P
hygroscopic material provided.
8.4 No risk of electric shock from accessible parts or from
parts rendered accessible following the removal of a No removable cover. N
cover which can be removed by hand
8.5 Class I apparatus N
Basic insulation between hazardous live parts and
N
earthed accessible parts
Resistors bridging basic insulation complying with
N
14.2a)
Capacitors bridging basic insulation complying with
N
14.3.2 a)
Protective earthing terminal N

Page 7 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

8.6 Class II apparatus P


a) Basic and supplementary insulation between
N
hazardous live parts and accessible parts
b) Reinforced insulation between hazardous live parts Secondary circuit to primary
and accessible parts circuit is separated by
P
reinforced insulation or
double insulation.
8.7 Components bridging insulation P
Basic insulation bridged by components complying with No such components.
N
14.4.5.3
Components bridging basic, supplementary, double or Transformers T1 bridging
reinforced insulation complying with 14.2 a) or 14.4 reinforced insulation
P
complying with 14.4,
see clause 14.4.
Basic and supplementary insulation each being bridged No such components.
N
by a capacitor or RC-unit complying with 14.3.2 a)
Double or reinforced insulation being bridged with 2
N
capacitors or RC-units in series complying with 14.3.2a)
Double or reinforced insulation being bridged with a
See clause 14.3.2 P
single capacitor or RC-unit complying with 14.3.2 b)
8.8 Insulation thickness and thin sheet materials P
Basic or supplementary insulation > 0,4 mm (mm) : N
Reinforced insulation > 0,4 mm (mm) ................... : - Approved opto-coupler
with thickness at least
0.4mm;
P
- Bobbin of transformers
T1 with min. thickness
0.75mm;
Thin sheet material used inside the equipment Provided in the isolating
P
transformers.
Basic or supplementary insulation, at least two layers,
N
each meeting 10.4
Basic or supplementary insulation, three layers any two
N
of which meet 10.4
Reinforced insulation, two layers each of which meet
N
10.4
Reinforced insulation, three layers any two which meet 3 layers insulation tape
10.4 wrapped on external of
transformer T1 as reinforced
P
insulation. 3000Vac applied
on any two layer of
insulation tape

Page 8 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

8.9 Adequate insulation between internal hazardous live Reinforced or double


conductors and accessible parts, or between internal insulation provided between
hazardous live parts and conductors connected to internal hazardous live
accessible parts conductors and secondary P
circuits which are
conductively connected to
accessible parts.
8.10 Double insulation between accessible parts and Reinforced or double
insulation provided. P
conductors connected to the mains
Double insulation between conductors connected to Reinforced or double
insulation provided. P
accessible parts and parts connected to the mains
8.11 Detaching of wires P
No undue reduction of creepage or clearance distances Internal secondary wires
if wires become detached were connected by
pluggable wire, connector or P
fixed by cable tie
and tapes

Vibration test carried out ........................................ : Considered. P


8.12 Adequate fastening of windows, lenses, lamp covers No such parts
N
etc. (pull test 20 N for 10 s)
8.13 Adequate fastening of covers (push/pull test 50 N for Applied on enclosure only
P
10 s)
8.14 No risk of damage to the insulation of internal wiring Internal wires cannot touch
due to hot parts or sharp edges hot parts or sharp edges
P
which can damage its
insulation.
8.15 Only special supply equipment can be used Not special supply
equipment. N

8.16 Insulated winding wire without additional interleaved


N
insulation
8.17 Endurance test as required by 8.16 N
8.18 Disconnection from the mains P
Disconnect device Mains plug or appliance
coupler is used as the P
disconnect device
All-pole switch or circuit breaker with >3mm contact All-pole switch P
separation
Mains switch ON indication Figure "I" used for ON
indication P

8.19 Switch not fitted in the mains cord No switch fitted on the
P
mains cord
8.20 Bridging components comply with clause 14 N
8.21 Non-separable thin sheet material N

9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITION P


9.1 Testing on the outside P
Page 9 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

9.1.1 General P
9.1.1.1 Requirements P
Accessible parts shall not be hazardous live Comply P
Inaccessible terminals are not accessible or comply with
P
relevant requirements
For voltages >1000 V ac or >1500 V dc complies with No voltages >1000Vac or
>1500Vdc N
clause 13.3.1 for basic insulation .......................:
9.1.1.2 Determination of hazardous live parts P
a) Open circuit voltages The open-circuit voltage of
the secondary circuit does
not exceed 60 Vdc or 35
Vpeak or the touch current
P
measurement was
conducted with the test
results in appended table
9.1.1.2 b).
b) Touch current measured from terminal devices using The measuring network was
the network in annex D ................................ : according to Annex D, see P
appended table 9.1.1.2 b).
c) Discharge not exceeding 45 µC The stores charges did not
exceed 45 µC. P

d) Energy of discharge not exceeding 350 mJ Less than 15 kV. N


9.1.1.3 Test with test finger and test probe The test finger and probe
cannot touch hazardous P
parts.
9.1.2 No hazardous live shafts of knobs, handles or levers No such parts. N
9.1.3 Ventilation holes and other holes tested by means of No hazardous live parts can
be accessed P
4 mm x 100 mm test pin
9.1.4 Terminal devices tested with 1 mm x 20 mm test pin No hazardous live parts can
be accessed P
(10 N); test probe D of IEC 61032
Terminal devices tested with 1 mm x 100 mm straight No hazardous live parts can
be accessed P
wire (1 N); test probe D of IEC 61032
9.1.5 Pre-set controls tested with 2.5 mm x 100 mm test pin No pre-set controls used
N
(10 N); test probe C of IEC 61032
9.1.6 Withdrawal of the mains plug P
No shock hazard due to stored charge after 2 s ... : 10V, 2s after withdrawal of
plug under normal
operation. (limit: 60Vdc)
36V, 2s after withdrawal of P
plug with R4 open circuited.
(limit: 60Vdc)
No hazards.
Bleeder resistor(s) comply with 14.2 or no shock hazard No shock hazard when open
circuited. See above. P
when open circuited
If C is not greater than 0,1 µF no test needed N

Page 10 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

9.1.7 Resistance to external force P


a) Test probe 11 of IEC 61032 for 10 s (50 N) No damage of enclosure
and no hazardous live parts P
are accessible.
b) Test hook of fig. 4 for 10 s (20 N) No hazardous live parts are
P
accessible.
c) 30 mm diameter test tool for 5 s (100 or 250 N) 100N P
9.2 No hazard after removing a cover by hand N

10 INSULATION REQUIREMENTS P
10.2 Insulation resistance (M ) at least 2 M min. after Tested between primary
and accessible parts, after
surge test for basic and 4 M min. for reinforced P
tested, EUT complied with
insulation ................................................................. : the requirements of 10.4
10.3 Humidity treatment 48 h or 120 h .......................... : 95% R.H., 30ºC, 48h P
10.4 Insulation resistance and dielectric strength P
Between parts of different polarity directly connected to (See appended table 10.4)
P
the mains
Between parts separated by BASIC or Class II apparatus.
N
SUPPLEMENTARY insulation
Between parts separated by REINFORCED insulation (See appended table 10.4) P

11 FAULT CONDITIONS P
11.1 No shock hazard under fault condition P
11.2 Heating P
11.2.1 Requirements P
No danger of fire to the surroundings No fire occurred. P
Safety not impaired by abnormal heat P
Flames extinguish within 10 seconds No flames occurred N
No hazard from softening solder No softening of solder point. P
Soldered terminations not used as protective
No such part used. P
mechanism
11.2.2 Measurement of temperature rises (see appended table 11.2) P
11.2.3 Temperature rise of accessible parts (see appended table 11.2) P
11.2.4 Temperature rise of parts, other than windings and
(see appended table 11.2) P
printed boards, providing electrical insulation
11.2.5 Temperature rise of parts acting as a support or
(see appended table 11.2) P
mechanical barrier
11.2.6 Temperature rise of windings (see appended table 11.2) P
11.2.7 Printed boards P

Page 11 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Temperature rise does not exceed the limits of table 3 (see appended table 11.2)
or exceed the limits of table 3 by max. 100 K for max. P
5 min
a) Temperature rise of V-0 or VTM-0 printed circuit
boards exceeding the limits of table 3 by not more than N
100 K for an area not greater than 2 cm²
b) Temperature rise of V-0 or VTM-0 printed circuit
boards exceeding the limits of table 3 up to 300 K for an N
area not greater than 2 cm²for a maximum of 5 min
Meets all the special conditions if conductors on printed
N
circuit boards are interrupted
Class I protective earthing maintained Class II apparatus. N
11.2.8 Temperature rise of parts not subject to the limits of
11.2.2 to 11.2.7 shall not exceed the limits in table 3, N
item e), "Fault conditions".

12 MECHNICAL STRENGTH P
12.1 Complete apparatus P
12.1.1 The apparatus have adequate mechanical strength P
12.1.2 Bump test where mass >7 kg Mass= 10.9kg; P
12.1.3 Vibration test Complied. P
12.1.4 Impact hammer test 0.5J, 3 times applied on top,
sides, bottom, rear and front
of enclosure (After tested,
no damage and EUT can P
withstand the dielectric
strength test as specified in
10.4 )
Steel ball test 2J, 1 time applied on top,
sides, bottom front of
enclosure (After tested, no
damage and EUT can P
withstand the dielectric
strength test as specified in
10.4 )
12.1.5 Drop test for portable apparatus where mass ≤ 7 kg N
12.1.6 Thermoplastic enclosures stress relief test P
12.2 Fixing of knobs, push buttons, keys and levers P
12.3 Remote controls with hazardous live parts No such remote controls
N
used.
12.4 Drawers (pull test 50 N, 10 s) No drawers used. N
12.5 Antenna coaxial sockets providing isolation No such sockets N
12.6 Telescoping or rod antennas P

Page 12 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

12.6.1 6,0mm diameter end Provided min. 6.18 mm


diameter button on the end P
of rod antennas
Prevented from falling into the apparatus After subjected to a 20N P
force for 1min, no removal.
12.6.2 Physical securement, removal prevented Complied. P
12.7 Apparatus containing coin / button cell batteries
N
(No such coin / button cell batteries )

12.7.2 Reduced possibility for children to remove battery N


12.7.3 Tests N
12.7.3.2 Stress relief test N
12.7.3.3 Battery replacement test N
12.7.3.4 Drop test N
12.7.3.5 Impact test N
12.7.4 Battery not accessible; or not removable N

13 CLEARANCES AND CREEPAGE DISTANCES P


13.1 Clearances in accordance with 13.3 Pollution degree 2 and
P
material group IIIb.
Creepage distances in accordance with 13.4 P
13.2 Determination of working voltage P
13.3 Clearances P
13.3.1 Comply with 13.3 or Annex J P
13.3.2 Circuits conductively connected to the mains comply (See appended table
13.3&13.4) P
with table 8 and, where applicable, table 9 ............ :
13.3.3 Circuits not conductively connected to the mains No hazard when short
comply with table 10 circuited according to clause P
11.
13.3.4 Measurement of transient voltages N
13.4 Creepage distances not less than appropriate table (See appended table
13.3&13.4) P
11 minimum values
13.5 Printed boards P
13.5.1 Conductors complying with pull-of and peel strength
requirements, one of which may be conductively P
connected to the mains, as in fig. 10
13.5.2 Type B coated printed circuit boards complying with
N
IEC 60664-3 (basic insulation only)
13.6 Conductive parts along uncemented joints clearances
N
and creepage distances comply with 13.3 and 13.4
Conductive parts along reliably cemented joints comply
N
with 8.8

Page 13 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Temperature cycle test and dielectric strength test N


500V test for transformers, magnetic coupler and similar N
devices, if insulation is relied upon for safety
13.7 Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and N
creepage distances as in table 12
13.8 Parts filled with insulating compound, meeting the Approved optocoupler used.
See appended table 14 for P
requirements of 8.8
the source details.

14 COMPONENTS P
14.1 Flammability according to IEC 60695-11-10 or annex G,
P
or 20.2.5
14.2 Resistors N
Resistors separately approved .............................. : No such resistors. N
E- Resistors between hazardous live parts and
N
accessible metal parts
b) Resistors, other than between hazardous live
N
parts and accessible parts
14.3 Capacitors and RC units P
Capacitors separately approved : P
14.3.1 Damp heat test duration 21 days N
14.3.2 Y capacitors tested to IEC 60384-14:2005 ............ : Approved Y-capacitor used
P
(see appended table 14)
14.3.3 X capacitors tested to IEC 60384-14:2005 ............ : Approved X-capacitor used
(see appended table 14) P

14.3.4 Capacitors operating at mains frequency but not No such components used.
N
connected to the mains: tests for X2 ...................... :
14.3.6 Capacitors with volume exceeding 1750 mm³, where The capacitors except metal
short-circuit current exceeds 0,2 A: compliance with cased type provided with N
IEC 60384-1, 4.38 category B or better .................. : volume less than 1750 mm³

Capacitors with volume exceeding 1750 mm³, mounted


closer to a potential ignition source than table 13
N
permits: compliance with IEC 60384-1, 4.38 category B
or better ................................................................... :
14.4 Inductors and windings P
14.4.1 Comply with IEC 61558-1, IEC 61558-2
N
(as relevant) and clause 20.2.5
Transformers and inductors separately approved .: Tested with appliance N
14.4.2 Transformers and inductors marked with The transformer marked
manufacturer’s name and type .............................. : with the trademarks and
type. P
See appended table 14.

Page 14 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

14.4.3 General See clause 14.4.4, 14.4.5


P
and 14.4.6.
Insulation material complies with clause 20.2.5 See clause 20.2.5. P
14.4.4 Constructional requirements P
14.4.4.1 Clearances and creepage distances comply with Transformer complied with
P
clause 13 clause 13.
14.4.4.2 Transformers meet the constructional requirements Complied. P
14.4.5 Separation between windings P
14.4.5.1 Class II transformers have adequate separation Double or reinforced
between hazardous live parts and accessible parts insulation separated
P
(double or reinforced insulation) ..............................: between primary windings
and secondary windings.
Coil formers and partition walls > 0,4 mm Measured: Min. 0.75mm P
14.4.5.2 Class I transformers, with basic insulation and Class II transformer
N
protective screening only if all 7 conditions are met
14.4.5.3 Separating transformers with at least basic No such transformers N
insulation
14.4.6 Insulation between hazardous live parts and accessible parts P
14.4.6.1 Class II transformers have adequate insulation between Double or reinforced
hazardous live parts and accessible parts (double or insulation separated
reinforced insulation) between hazardous
live windings and windings P
intended to be connected to
output terminals. See also
sub-clause 8.8.
Coil formers and partition walls > 0,4 mm Measured: Min. 0.75mm P
14.4.6.2 Class I transformers have adequate insulation between Class II transformer
hazardous live parts and accessible conductive parts or
N
those conductive parts or protective screens connected
to a protective earth terminal
Winding wires connected to protective earth have
N
adequate current-carrying capacity
14.5 High voltage components and assemblies (U > 4kV peak) N
14.5.1 Component meets category V-1 of IEC 60695-11-10 No high-voltage
N
components used.
14.5.2 High voltage transformers and multipliers N
14.5.3 High voltage assemblies and other parts N
14.6 Protective devices P
14.6.1 Protective devices used within their ratings P
External clearances and creepage distances meet (see appended table 13.3 &
requirement of clause 13 for the voltage across the 13.4) P
device when opened

Page 15 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

14.6.2 Thermal releases N


14.6.2.1 Comply with 14.6.2.2, 14.6.2.3 or 14.6.2.4 No such component. N
14.6.2.2 a) Thermal cut-outs separately approved No such component. N
b) Thermal cut-outs tested as part of the submission N
14.6.2.3 a) Thermal links separately approved No thermal links used N
b) Thermal links tested as part of the submission N
14.6.2.4 Thermal devices re-settable by soldering No such devices N
14.6.3 Fuses and fuse holders P
14.6.3.1 Fuse-links in the mains circuit according to IEC 60127 Approved mains fuse used P
14.6.3.2 Correct marking of fuse-links adjacent to holder ... : Marked on PCB adjacent to
component: F1 T3.15AL P
250Vac.
14.6.3.3 Not possible to connect fuses in parallel Single fuse is used P
14.6.3.4 Not possible to touch hazardous live parts when No fuse holder. Fuse can’t
be replaced without N
replacing fuse-links without the use of a tool ......... :
damaging equipment.
14.6.4 PTC thermistors comply with IEC 60730-1:2010 No such components
provided. N

PTC devices (>15 W) category V-1 or better N


14.6.5 Circuit protectors have adequate breaking capacity and No such components
N
their position is correctly marked provided.
14.7 Switches P
14.7.1 a) Separate testing to IEC 61058-1 including: (see appended table 14)
- 10 000 operations
- Normal pollution suitability
- For CRT TV’s, make and break speed P
independent of speed of actuation
- V-0 or compliance with G.1.1
14.7.1 b) Tested in the apparatus N
Switch controlling > 0.2A with open contact voltage > 35
V (peak) / 24 V dc complying with 14.6.3, 14.6.4 and N
V-0 or G.1.1
Switch controlling > 0.2A with open contact voltage < 35
V (peak) / 24 V dc complying with 14.6.3 and V-0 or N
G.1.1
Switch controlling ≤ 0.2A with open contact voltage > 35
V (peak)/24 V dc complying with 14.6.4 and V-0 or N
G.1.1
14.7.2 Switch tested to 14.7.1 b) checked according to IEC
N
61058-1 clause 13.1 and 10 000 operation test
14.7.3 Switch tested to 14.6.1 b) compliant with IEC 61058- 1
subclause 16.2.2 d) and m) not attaining excessive N
temperatures in use

Page 16 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

14.7.4 Switch tested to 14.6.1 b) has adequate dielectric


N
strength
14.7.5 Mains switch controlling mains socket outlets additional
N
tests to IEC 61058-1
14.8 Safety interlocks according to 2.8 of IEC 60950-1 No safety interlocks used N
14.9 Voltage setting device and the like are not likely to be
N
changed accidentally
14.10 Motors (No motors used) N
14.10.1 a) Endurance test on motors No such component. N
b) Motor start test N
Dielectric strength test N
14.10.2 Not adversely affected by oil or grease etc. N
14.10.3 Protection against moving parts N
14.10.4 Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and N
B.10 of IEC 60950-1, Annex B
14.11 Batteries P
14.11.1 Comply with IEC 62133 if applicable N
Batteries mounted with no risk of accumulation of
N
flammable gases
14.11.2 No possibility of recharging user replaceable non
N
rechargeable batteries
14.11.3 Recharging currents and times within manufacturers
limits Max. recharge current:
0.98A at normal condition
P
1.28A at abnormal condition
(the limit value 2.1A)

Lithium batteries discharge and reverse currents within


N
the manufacturers limits
14.11.4 Battery mould stress relief N
14.11.5 Battery drop test N
14.12 Optocouplers P
Comply with constructional requirements of clause 8 P
External clearances and creepage comply with 13.1 P
Compound completely filling the casing or internal
P
clearances and creepage comply with 13.1 ..............:
a) Complies with 13.6 (jointed insulation) and N.3.2 N
b) Complies with IEC 60747-5-5:2007 Approved optocoupler is
used, see appended table P
14 for the details.

Page 17 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

c) Complies with 13.8 N

14.13 Surge suppression varistors N


Comply with IEC 61051-2 No such components
provided. N

Not connected between mains and accessible parts


except for earthed parts of permanently connected N
apparatus
GDT bridging basic insulation complies with electric
N
strength and distance requirements

15 TERMINALS P
15.1 Plugs and sockets P
15.1.1 Mains plug, appliance inlet, interconnection couplers Mains plug meet the
and mains socket-outlet meet the appropriate standard appropriate standard. P
See appended table 14.
Overloading of plugs or appliance inlets prevented if the No mains socket outlets.
N
apparatus has mains socket outlets
Overloading of internal wiring prevented if the apparatus
N
has mains socket outlets
15.1.2 Design of connectors other than for mains power P
Design of sockets with symbol of 5.3 b) design N
15.1.3 Design of terminals and connectors used in output Mismatching of connectors
N
circuits of supply apparatus is not possible.
15.2 Provision for protective earthing N
Accessible conductive parts of Class I equipment Class II apparatus.
N
reliably connected to earth terminal, within equipment
Protective earth conductors correctly fixed and
N
coloured
Separate protective earth terminal near mains
N
terminal and comply with 15.3
Protective earth terminal resistant to corrosion N
Earth resistance test: < 0,1Ω at 25 A ................... : N
15.3 Terminals for external flexible cords and for permanent connection to the
P
mains supply
15.3.1 Adequate terminals for connection of permanent Not permanent wiring
N
wiring
15.3.2 Reliable connection of non-detachable cords Detachable cords used
N

Not soldered to conductors of a printed circuit board N

Page 18 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Adequate clearances and creepage distances between


N
connections should a wire break away
Wire secured by additional means to the conductor N
15.3.3 Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar N

15.3.4 Conductors adequately fixed (two independent fixings) P


15.3.5 Terminals allow connection of conductors having
appropriate cross-sectional area P

15.3.6 Terminals to 15.3.3 have sizes required by table 16 N


15.3.7 Terminals clamp conductors between metal and have
N
adequate pressure
Terminals designed to avoid conductor slipping out
N
when tightened
Terminals adequately fixed when tightened or loosened
(no loosening, wiring not stressed, distances not N
reduced)
15.3.8 Terminals carrying a current more than 0,2 A: contact A certified primary
pressure not transmitted by insulating material except connector was used with its P
ceramic rating.
15.3.9 Termination of non-detachable cords: wires terminated A certified primary
near to each other connector was used with its P
rating.
Terminals located and shielded: test with 8 mm strand N
15.4 Devices forming a part of the mains plug N
15.4.1 No undue strain on mains socket-outlets N
15.4.2 Device complies with standard for dimensions of mains
N
plugs
15.4.3 Device has adequate mechanical strength (tests a,b,c) N

16 EXTERNAL FLEXIBLE CORDS P


16.1 Mains cords sheathed type, complying with IEC 60227 Approved PVC cord used.
for PVC or IEC 60245 for synthetic rubber (See appended table 14) P
cords ........................................................... :
Non-detachable cords for Class I have green/yellow Class II equipment.
N
core for protective earth
16.2 Mains cords conductors have adequate cross- sectional Rated current<3A, cross-
area for rated current consumption of the equipment sectional area: 2 x 0.5 mm 2

P
min, with length ≤ 2m
(see appended table 14)
16.3 Flexible cords not complying with 16.1, used for
interconnections between separate units of equipment
N
used in combination and carrying hazardous live
voltages comply with a) and b)

Page 19 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

16.4 Flexible cords used for connection between equipment


have adequate cross-sectional areas to avoid N
temperature rise under normal and fault conditions
16.5 Adequate strain relief on external flexible cords Approved AC inlet used. N
Not possible to push cord back into equipment N
Strain relief device unlikely to damage flexible cord N
For mains cords of Class I equipment, hazardous live Class II equipment.
N
conductors become taut before earth conductor
16.6 Apertures for external flexible cord: no risk of damage
P
to the cord during assembly or movement in use
16.7 Transportable apparatus have appliance inlet according
P
to IEC 60320-1 or means of stowage to protect the cord

17 ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS P


17.1 Table 20 torque test metal thread, 5 times................: Torque used: 0.6 Nm
(Screws with diameter
P
3.04mm use for fixing metal
enclosure);
Table 20 torque test non-metallic thread, 10 times...: Torque used: 0.8 Nm
(Screws with diameter
P
3.45mm use for fixing the
plastic enclosure).
17.2 Correct introduction into female threads in non- metallic
P
material
17.3 Cover fixing screws captive or no hazard when replaced
P
by a screw whose length is 10 times its diameter
17.4 No loosening of conductive parts carrying a current >
P
0,2 A
17.5 Contact pressure not transmitted through insulating Contact pressure not
material other than ceramic for connections carrying a transmitted through plastic. P
current > 0,2 A
17.6 Stranded conductors of flexible supply cords carrying a
current > 0,2 A with screw terminals not consolidated by N
solder
17.7 Cover fixing devices have adequate strength and their
N
positioning is unambiguous
17.8 Fixing means for detachable legs or stands provided N
17.9 Internal pluggable connections, affecting safety, unlikely
P
to become disconnected

18 MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST


N
THE EFFECTS OF IMPLOSION
18.1 Comply with IEC 61965 or 18.2 No picture tube used. N

Page 20 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

18.2 Non-intrinsically protected tubes N

19 STABILITY AND MECHANICAL HAZARDS P


19.1 Apparatus > 7kg have adequate stability or is required
to be fastened in place and provided with the warning of Complied P
5.5.2 f) ............................................. :
o
19.2 Test at 10 to the horizontal Complied P
19.3 Vertical force test 100 N applied downwards Complied P
19.4 Horizontal force test, 100 N or 13% of weight, applied
N
horizontally to point of least stability
19.5 Edges or corners not hazardous Edges and corners are
smooth P

19.6 Mechanical strength of glass N


19.6.1 Glass surfaces (exc.laminated) with an area exceeding
0,1 m²or major dimension > 450 mm, pass the test of N
12.1.4
19.6.2 Fragmentation test N
19.7 Wall or ceiling mounting means N
19.7.1 – Not dislodged and remain mechanically intact after
N
19.7.3 test according to 19.7.2 Test 1, Test 2 or Test 3.......:

20 RESISTANCE TO FIRE P
20.1 Start and spread of fire is prevented Complied. P
20.2 Electrical components and mechanical parts P
20.2.1 a) Exemption for components contained in an Wooden enclosure minimum
enclosure of material V-0 to IEC 60695-11-10 with 6.0 mm thick and metallic P
openings not exceeding 1 mm in width enclosure used

b) Exemption for small components Some small components


mounted on UL approved
P
PCB with flammability of
Min.V-1
20.2.2 Electrical components meet the requirements of Clause
P
14 or 20.2.5
20.2.3 Insulation of internal wiring working at voltages > 4 kV No voltage > 4kV
or leaving an internal fire enclosure, or located within N
the areas mentioned in Table 21, comply with G.2
20.2.4 Material of printed circuit boards on which the available Min.V-1 PCB used for the
power exceeds 15 W at a voltage between 50 V and power board
P
400 V (peak) a.c. or d.c. meets V-1 or better to IEC
60695-11-10, unless used in a fire enclosure
Material of printed circuit boards on which the available See above for the power
power exceeds 15 W at a voltage >400 V (peak) a.c. or board P
d.c. meets V-0 to IEC 60695-11-10.

Page 21 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

20.2.5 Components and parts not covered by 20.1.1, 20.1.2


and 20.1.3 (other than fire enclosures) mounted nearer
to a potential ignition source than the distances in Table P
21 comply with the relevant flammability category in
Table 21
Components and parts as above but shielded from a See above.
potential ignition source, with the barrier area in P
accordance with Table 21 and fig. 13
Apparatus with voltages >4kV under normal operating No voltage > 4kV
conditions and distances to the enclosure exceed those
N
specified Table 21, flammability classification HB40 or
better is required for the enclosure
20.3 Fire enclosure N
20.3.1 Potential ignition sources with open circuit voltage > 4 Open voltage not exceed 4
kV (peak) a.c. or d.c. contained in a fire enclosure to KV (peak) a.c. or d.c. N
V-1
20.3.2 Internal fire enclosures with openings not exceeding 1
mm in width and with openings for wires completely N
filled
20.3.3 Requirements of 20.2.1 and 20.2.2 met by an internal
N
fire enclosure

ANNEX A ADDITIONAL REQUIREMENTS FOR APPARATUS WITH PROTECTION


N
AGAINST SPLASHING WATER
A.5 Marking and instructions N
A.5.1 A.5.2 i) Marked with at least IPX4 (IEC 60529) The equipment is used
N
5.5.2 a) does not apply indoor
A.10 Insulation requirements only. N
A.10.3 Splash and humidity treatment N
A.10.3.1 The enclosure provide adequate protection against
N
splashing water
A.10.3.2 Complies with 10.3,duration of the test is 168h N

ANNEX B APPARATUS TO BE CONNECTED TO TELECOMUNICATION THE


N
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1 N
Complies with IEC 62151 clause 2 N
Complies with IEC 62151 clause 3 modified N
Complies with IEC 62151 clause 4 modified N
Complies with IEC 62151 cause 5 modified N
Complies with IEC 62151 clause 6 N
Complies with IEC 62151 clause 7 N

Page 22 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Complies with IEC 62151 annex A, B and C N

ANNEX L ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH APPARATUS FOR


N
PHOTOGRAPHIC PURPOSES
L.5 Marking and instructions N
L.5.5.1 Instructions for battery chargers and Supply apparatus The EUT is not electronic
indicating type or model number of flash apparatus with flash apparatus. N
which it is to be used
Instructions for flash apparatus indicating type or model
number of battery chargers or Supply apparatus with N
which it is to be used
L.7 Heating under normal operating conditions N
L.7.1.6 Lithium batteries meet permissible temp rise in Table 3 N
L.9 Electric shock hazard under normal operating conditions N
L. 9.1.1.1 Terminals for connection to synchroniser not hazardous
N
live
L.14 Components N
L.14.6.7 Mains switch characteristics appropriate to its
N
function under normal conditions

Page 23 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60065


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(Audio, video and similar electronic apparatus – Safety requirements)
Differences according to ............... : EN 60065:2014
Attachment Form No...................... : EU_GD_IEC60065L
Master Attachment ......................... : Date 2015-03
Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

CENELEC COMMON MODIFICATIONS (EN) P


General 1.1.3 Note 2 5.4 Note 5.5.2 Note 1 and P
Note 2
13.3.1 Note 4 14.1 Note 1 and 15.1.1 Note 1 and
Note 2 Note 2
15.2 Note 2 16.1 Note 2 16.2 Note
20 Note J.3 Note 1 and
Table J.1 Note 2
1.2 Normative references N
Add the following: Added. N
EN 71-1, Safety of toys – Part 1: Mechanical and
physical properties
EN 50332-1, Sound system equipment: Headphones
and earphones associated with personal music
players – Maximum sound pressure level
measurement methodology – Part 1: General method
for “one package equipment”
EN 50332-2, Sound system equipment: Headphones
and earphones associated with personal music
players – Maximum sound pressure level
measurement methodology – Part 2: Matching of sets
with headphones if either or both are offered
separately, or are offered as one package equipment
but with standardised connectors between the two
allowing to combine components of different
manufacturers or different design
3 General requirements P
3.Z1 Protective devices Complied P
To protect against excessive current, short-circuits
and earth faults in MAINS, protective devices shall be
included either as integral parts of the equipment or
as parts of the building installation, subject to the
following, a), b) and c):
a) except as detailed in b) and c), protective devices
necessary to comply with the requirements of Clause
11 shall be included as parts of the equipment;
b) for components in series or parallel with the mains
input to the equipment such as the supply cord,
appliance coupler, r.f.i. filter and switch, short-circuit
and earth fault protection may be provided by
protective devices in the building installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on dedicated
over current and short-circuit protection in the building
Page 24 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

installation, provided that the means of protection,


e.g. fuses or circuit breakers, is fully specified in the
installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so state,
except that for apparatus not supplied via an industrial
mains plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be
regarded as providing protection in accordance with
the rating of the wall socket outlet.
4 General test conditions N
4.1.1 Replace the text of the note by: N
NOTE For ROUTINE TEST, reference is made to EN 50514:2008.
6 Hazardous radiations N
6.1 Replace the entire subclause by the following: N
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided under
normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those internal
adjustments or pre-sets which are not locked in a
reliable manner, are adjusted so as to give maximum
radiation whilst maintaining an intelligible picture for 1
h, at the end of which the measurement is made.
NOTE 1 Soldered joints and paint lockings are examples of
adequate locking.
The dose-rate is determined by means of a radiation
monitor with an effective area of 10 cm , at any point
2

10 cm from the outer surface of the apparatus


Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is made.
The dose-rate shall not exceed 1 μSv/h (0,1 mR/h)
taking account of the background level.
NOTE 2 These values appear in Council Directive 96/29/Euratom
of 13 May 1996.
A picture is considered to be intelligible if the following
conditions are met:
- a scanning amplitude of at least 70 % of the usable
screen width;
- a minimum luminance of 50 cd/m²with locked blank
raster provided by a test generator;
- a horizontal resolution corresponding to at least 1,5
MHz in the centre, with a similar vertical degradation;
- not more than one flashover per 5 min.
16 External flexible cords P
16.1 Add the following note after the first paragraph: Added. P
NOTE Z1 The harmonized code designations corresponding to the
IEC cord types are given in Annex ZD.

Page 25 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Z1 Protection against excessive sound pressure from personal music players N


Z1.1 General Not such apparatus. N
This subclause specifies requirements for protection
against excessive sound pressure from personal
music players that are closely coupled to the ear.
Requirements for earphones and headphones
intended for use with personal music players are also
covered.
A personal music player is a portable equipment for
personal use, that:
− is designed to allow the user to listen to recorded or
broadcast sound or video; and
− uses a listening device, such as headphones or
earphones that can be worn in or on or around the
ears; and
− is body worn (of a size suitable to be carried in a
clothing pocket) and is intended for the user to walk
around while in use.
EXAMPLES CD players, MP3 audio players, mobile phones with
MP3 type features, PDA’s or similar equipment.
A personal music player shall comply with the
requirements of this subclause.
NOTE 1 Protection against acoustic energy sources from telecom
terminal equipment is referenced to ITU-T Recommendation P.360.
The requirements in this subclause are valid for music
or video mode only.
The requirements do not apply to:
− professional equipment;
NOTE 2 Professional equipment is equipment sold through special
sales channels. All products sold through normal electronics stores
are considered not to be professional equipment.
− hearing aid equipment and other devices for
assistive listening;
− the following types of analogue personal music
players:
• long distance radio receiver (for example, a
multiband radio receiver or a
world band radio receiver, an AM radio receiver) and
• cassette player/recorder;
NOTE 3 This exemption has been allowed because this technology
is falling out of use and it is expected that within a few years it will
no longer exist. This exemption will not be extended to other
technologies.
− player while connected to an external amplifier that
does not allow the user to walk around while in use.
For equipment clearly designed or intended for use by
young children, the limits of EN 71-1 apply.

Page 26 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Z1.2 Equipment requirements Not such apparatus. N


No safety provision is required for equipment that
complies with the following:
− equipment provided as a package (personal music
player with its listening device), where the acoustic
output Laeq,T is ≤ 85 dB(A) measured while playing the
fixed “programme simulation noise” as described in
EN 50332-1; and
− personal music player provided with an analogue
electrical output socket for a listening device, where
the electrical output is ≤ 27 mV measured as
described in EN 50332-2, while playing the fixed
“programme simulation noise” as described in EN
50332-1.
NOTE 1 Wherever the term acoustic output is used in this
subclause, the 30 s A-weighted equivalent sound pressure level
Laeq,T is meant. See also Z1.5 and Annex ZE.
All other equipment shall:
a) protect the user from unintentional acoustic outputs
exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and automatically
return to an output level not exceeding those
mentioned above when the power is switched off; and
c) provide a means to actively inform the user of the
increased sound pressure when the equipment is
operated with an acoustic output exceeding those
mentioned above. Any means used shall be
acknowledged by the user before activating a mode of
operation which allows for an acoustic output
exceeding those mentioned above. The
acknowledgement does not need to be repeated more
than once every 20 h of cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening time,
independent how often and how long the personal music player has
been switched off.
d) have a warning as specified in Z1.3; and
e) not exceed the following:
1) equipment provided as a package (player with its
listening device), the acoustic output shall be ≤ 100
dB(A) measured while playing the fixed “programme
simulation noise” described in EN 50332-1; and
2) a personal music player provided with an analogue
electrical output socket for a listening device, the
electrical output shall be ≤ 150 mV measured as
described in EN 50332-2, while playing the fixed
“programme simulation noise” described in EN 50332-
1.
For music where the average sound pressure (long
term Laeq,T) measured over the duration of the song is
lower than the average produced by the programme
simulation noise, the warning does not need to be
given as long as the average sound pressure of the
song does not exceed the basic limit of 85 dB(A). In
Page 27 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

this case, T becomes the duration of the song.


NOTE 4 Classical music typically has an average sound pressure
(long term Laeq,T) which is much lower than the average
programme simulation noise. Therefore, if the player is capable to
analyse the song and compare it with the programme simulation
noise, the warning does not need to be given as long as the
average sound pressure of the song is below the basic limit of 85
dB(A).
NOTE 5 For example, if the player is set with the programme
simulation noise to 85 dB(A), but the average music level of the
song is only 65 dB(A), there is no need to give a warning or ask an
acknowledgement as long as the average sound level of the song
is not above the basic limit of 85 dB(A).
Z1.3 The warning shall be placed on the equipment, or on Not such apparatus. N
the packaging, or in the instruction manual and shall
consist of the following:
− the symbol of Figure Z1 with a minimum height of 5
mm; and
− the following wording, or similar:
To prevent possible hearing damage, do not
listen at high volume levels for long periods.

Figure Z1 – Warning label (IEC 60417-6044)


Alternatively, the entire warning may be given through
the equipment display during use, when the user is
asked to acknowledge activation of the higher level.
Z1.4 Requirements for listening devices (headphones, earphones, etc.) N
Z1.4.1 Corded passive listening devices with analogue Not such apparatus. N
input
With 94 dB(A) sound pressure output Laeq,T, the input
voltage of the fixed “programme simulation noise”
described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where the
headphones can operate including any available
setting (for example built-in volume level control, an
additional sound feature like equalization, etc.).
NOTE The values of 94 dB(A) – 75 mV correspond with 85 dB(A) –
27 mV and 100 dB(A) – 150 mV.
Z1.4.3 Cordless listening devices Not such apparatus. N
In wireless mode:
− with any playing and transmitting device playing the
fixed programme simulation noise described in EN
50332-1; and
− respecting the wireless transmission standards,
where an air interface standard exists that specifies
the equivalent acoustic level; and
− with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.) set to
Page 28 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

the combination of positions that maximize the


measured acoustic output for the above-mentioned
programme simulation noise, the acoustic output
Laeq,T of the listening device shall be ≤ 100 dB(A).
Z1.5 Measurement methods Not such apparatus. N
Measurements shall be made in accordance with EN
50332-1 or EN 50332-2 as applicable. Unless stated
otherwise, the time interval T shall be 30 s.
NOTE Test method for cordless equipment provided without
listening device should be defined.

ANNEXES N
Annex B Replace the text of Note 1 by the following: Replaced.
In the CENELEC countries listed in IEC 62151, special national N
conditions apply.
Annex N After the note in N.1, add the following: Added.
For ROUTINE TEST, reference is made to EN N
50514:2008.

ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH 


THEIR CORRESPONDING EUROPEAN PUBLICATIONS

ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) P


2.6.1 Denmark Not such apparatus. N
The following is added:
Certain types of Class I apparatus, see 15.1.1, may
be provided with a plug not establishing earthing
continuity when inserted in Danish socket-outlets
Justification:
Heavy Current Regulations, Section 6c
3.Z1 Denmark Not such apparatus. N
Add to the end of the subclause
Due to many existing installations where the socket-
outlets can be protected with fuses with higher rating
than the rating of the socket-outlets the protection for
pluggable equipment type A shall be an integral part
of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
5.4 Denmark, Finland, Norway and Sweden Not such apparatus. N
To the end of the subclause the following is added:
CLASS I apparatus which is intended for connection to
the building installation wiring via a plug or an
appliance coupler, or both and in addition is intended
for connection to other apparatus or a network shall, if
safety relies on connection to protective earth or if
surge suppressors are connected between the
network TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be connected
to an earthed MAINS socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Denmark: “Apparatets stikprop skal tilsluttes en
Page 29 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

stikkontakt med jord, som giver forbindelse til stikproppens


jord.”
In Finland: ”Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan”
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
5.5.2 Norway and Sweden Not such apparatus. N
Add to the end of 5.5.2 (after the compliance
statement) the following:
The screen of the coaxial cable of the television
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
coaxial cable based television distribution system.
It is however accepted to provide the insulation
external to the apparatus by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by a retailer, for example.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what country
the apparatus is intended to be used in:
“Apparatus connected to the protective earthing of the
building installation through the MAINS connection or
through other apparatus with a connection to
protective earthing – and to a television distribution
system using coaxial cable, may in some
circumstances create a fire hazard. Connection to a
television distribution system has therefore to be
provided through a device providing electrical
isolation below a certain frequency range (galvanic
isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of CATV-
installations, and in Sweden, a galvanic isolator shall provide
electrical insulation below 5 MHz. The insulation shall withstand a
dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via nettplugg
og/eller via annet jordtilkoplet utstyr – og er tilkoplet et
kabel-TV nett, kan forårsake brannfare.
For å unngå dette skal det ved tilkopling av utstyret til
kabel-TV nettet installeres en galvanisk isolator
mellom utstyret og kabel-TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och samtidigt
är kopplad till kabel-TV nät kan i vissa fall medfőra
risk főr brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator finnas
mellan utrustningen och kabel-TV nätet.”

13.3.1 Norway N
Page 30 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

Add to the second paragraph the following:


Due to the IT power distribution system used, the a.c.
MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230 V in case of a
single earth fault.
Justification:
Based on a use in Norway of an IT power distribution
system where the neutral is not provided
15.1.1 Denmark Not such apparatus. N
To the first paragraph the following is added:
In Denmark, supply cords of single phase appliances
having a rated current not exceeding 13 A shall be
provided with a plug according to DS 60884-2-D1.
Appliances of Class I provided with socket-outlets
with earth contact or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be
provided with a plug which assure earth continuity
with the socket-outlet in accordance with DS 60884-2-
D1.
If a single-phase equipment having a RATED
CURRENT exceeding 13 A or if a poly-phase
equipment is provided with a supply cord with a plug,
this plug shall be in accordance with the standard
sheets DK 6-1a in DS 60884-2-D1 or EN 60309-1.
To the second paragraph the following is added:
Socket outlets intended for providing power to Class II
apparatus with a rated current of 2,5 A shall be in
accordance with DS 60884-2-D1 standard sheet DKA
1-4a.
Other current rating socket outlets shall be in
compliance with DS 60884-2-D1 Standard Sheet DKA
1-3a or DKA 1-1c.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be in
compliance with DS 60884-2-D1, Standard sheet DK
1-3a, DK 1-1c, DK 1-1d, DK 1-5a or DK 1-7a
Justification:
Heavy Current Regulations, Section 6c
15.1.1 Ireland Not such apparatus. N
Apparatus which is fitted with a flexible cable or cord
shall be provided with a plug in accordance with
Statutory Instrument 525: 1997, “13 A Plugs and
Conversion Adapters for Domestic Use Regulations:
1997.
Justification:
SI 525: 1997

Page 31 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

15.1.1 Norway No socket-outlet used. N


Mains socket-outlets mounted on Class II apparatus
shall comply with the specifications given in CEE
Publ. 7 as far as applicable, with the following
amendments:
§ 8 Dimensions
a) 2,5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
STANDARD SHEET I
2,5 A/250 V SOCKET-OUTLET FOR ELECTRONIC
APPLIANCES OF CLASS II

Dimensions in mm
Other dimensions according to CEE
Publication 7 Standard Sheet I
“Portable Single-Way Socket-Outlets”.
§ 24 Mechanical strength
E- 2,5 A, 250 V socket-outlets for Class II electronic
apparatus are tested as specified in EN
60065:2014, 12.1.3. Also the protecting rim shall
be tested.
Justification:
Act of 24 May 1929 relating to supervision of electrical
installation (TEA 1929/FEL 1998).
15.1.1 United Kingdom N
Apparatus which is fitted with a flexible cable or cord
and is designed to be connected to a mains socket
conforming to BS 1363 by means of that flexible cable
or cord and plug shall be fitted with a “standard plug”
in accordance with Statutory Instrument 1768: 1994:
The Plugs and Sockets etc. (Safety) Regulations
1994, unless exempted by those Regulations.
NOTE “Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification:
SI 1768: 1994
Annex B Finland, Norway and Sweden Not such apparatus. N
All sub clauses given below are sub clauses of IEC
62151 (ref. Corrigenda 1 and 2 to IEC 62151).
Subclause 4.1.1 (corrigendum 2):
Add after the first paragraph:
NOTE In Finland, Norway and Sweden, CLASS I
equipment which is intended for connection to the
Page 32 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

building installation via a non-industrial plug or a


non-industrial appliance coupler, or both and in
addition is intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and ACCESSIBLE parts, has a marking
stating that the equipment must be connected to an
earthed mains socket-outlet.
The marking text in the applicable countries shall be
as follows:
In Finland: “ Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan ”
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: ”Apparaten skall anslutas till jordat uttag”
Subclause 4.1.4 (corrigendum 1)
Add at the end of the subclause:
NOTE In Norway, for requirements see 4.1.1, note and 5.3.1, note 1.
Subclause 4.2.1.2 (corrigendum 1)
Add at the end of the subclause:
NOTE 3 In Norway, for requirements see 5.3.1, note 1.
Subclause 4.2.1.3 (corrigendum 2)
Add at the end of the subclause:
.
NOTE In Norway, for requirements see 4.1.1, note and 5.3.1, note 1
Subclause 4.2.1.4 (corrigendum 1)
Number the existing note as NOTE 1 and add at the
end of the subclause the
following NOTE 2:
NOTE 2 In Norway, for requirements see 4.1.1, note and 5.3.1, note 1.
Subclause 5.3.1 (corrigendum 1)
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there are additional requirements for the
insulation.
Renumber the existing note as NOTE 2.
For additional requirements for the insulation in
Finland, Norway and Sweden in NOTE 1 the following
text is added between the first and the second
paragraph (this text is identical to the corresponding
EN 60950-1:2001):
NOTE 1 In Finland, Norway and Sweden, if this
insulation is solid, including insulation forming part
of a component, it shall at least consist of either •
two layers of thin sheet material, each of which
shall pass the electric strength test below, or
• one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that CLEARANCES
and CREEPAGE DISTANCES do not exist, if the
component passes the electric strength test in the
accordance with the compliance clause below and
in addition:
Page 33 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

• passes the test and inspection criteria of 13.6 with


an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
• is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5 kV
(for performance of the test see N.2.1).
It is permitted to bridge this insulation with a capacitor complying with EN 132400:1994,
subclass Y2.
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation under
the following conditions:
• the insulation requirements are satisfied by having a capacitor classified Y3 as defined
by EN 132400, which in addition to the Y3 testing, is tested with an impulse test of 2,5 kV
defined in IEC 62151:2000, 6.2.1;
• the additional testing shall be performed on all the test specimens as described in EN
132400;
• the impulse test of 2,5 kV is to be performed before the endurance test in EN 132400 in
the sequence of tests as described in EN 132400.
Subclause 5.3.2 (corrigendum 1)
Add after the fourth dash:
NOTE In Finland, Norway and Sweden, exclusions are applicable for equipment which is
intended for connection to the building installation wiring using screw terminals or other
reliable means, and for equipment which is intended for connection to the building
installation wiring via an industrial plug and socket –outlet or an appliance coupler, or
both, complying with EN 60309 or with a comparable national standard.
J.2 Norway N
After Table J.1 the following is added:
Due to the IT power distribution system used, the a.c.
MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230 V in case of a
single earth fault.
Justification:
Based on a use in Norway of an IT power distribution
system where the neutral is not provided

C ANNEX ZC, NATIONAL DEVIATIONS (EN) --


5.1 Italy Not such apparatus. N
The following requirements shall be fulfilled:
- The power consumption in Watts (W) shall be
indicated on TV receivers and in their instruction for
use (Measurement according to IEC 60107-1)
NOTE EN 60555-2 has since been replaced by IEC 60107-1:1997.
- TV receivers shall be provided with an instruction for
use, schematic diagrams and adjustments procedure
in Italian language.
- Marking for controls and terminals shall be in Italian
language. Abbreviation and international symbols are
allowed provided that they are explained in the
instruction for use.
- The ECC manufacturers are bound to issue a
conformity declaration according to the above
requirements in the instruction manual. The correct
statement for conformity to be written in the
instruction manual, shall be:
Questo apparecchio è fabbricato nella CEE nel
rispetto delle disposizioni del D.M. marzo 1992 ed è in
particolare conforme alle prescrizioni dell’art. 1 dello
stesso D.M.
- The first importers of TV receivers manufactured
outside EEC are bound to submit the TV receivers for
previous conformity certification to the Italian Post
Ministry (PP.TT).
Page 34 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

IEC 60065
Clause Requirement + Test Result - Remark Verdict

The TV receivers shall have on the backcover the


certification number in the following form:
D.M. 26/03/1992 xxxxx/xxxxx/S or T or pT
S for stereo
T for teletext
pT for retrofitable teletext
Justification:
Ministerial Decree of 26 March 1992: National rules
for television receivers trade.
NOTE The ministerial decree above contains additional, but not
safety relevant requirements.
6.1 Germany No such device. N
The following requirement applies:
For the operation of any cathode ray tube intended for
the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization is
required, or application of type approval
(Bauartzulassung) and marking.
Justification:
German ministerial decree against ionizing radiation
(Röntgenverordnung), in force since 2002-07-01,
implementing the Council Directive 96/29/Euratom in
Germany.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-
38116 Braunschweig, Tel.: Int+49-531-592-6320, Internet:
http://www.ptb.de
14.1 Sweden No such component. N
The following requirements shall be fulfilled:
Switches containing mercury such as thermostats,
relays and level controllers are not allowed.

Page 35 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

7.1 TABLE: temperature rise measurements P

Power consumption in the OFF/Stand-by OFF: 0W --


Position of the functional switch (W) ...................... : -- --

Cond. Un (V) Hz In (A) Pn (W) Uout (V) Pout (W) Operating Condition / Status

1. 90 50 0.556 28.4 SUB= SUB=


1.36 0.46
2. 100 50 0.510 28.3
L/R=1.31 L/R=0.21
3. 240 50 0.244 27.8
4. 264 50 0.231 28.1
5. 90 60 0.549 28.3 USB mode, pink noise signal input,
6. 100 60 0.510 28.3 adjust volume to1/8 of Max. Non-
clipped output power on speakers.
7. 240 60 0.242 28.0
8. 264 60 0.227 28.1
SUB= SUB=
9 15 -- 0.53 7.9 1.04 0.27
L/R=1.01 L/R=0.13
10 90 50 0.574 28.8 SUB= SUB=
1.32 0.44
11 100 50 0.534 28.7
L/R=1.29 L/R=0.21
12 240 50 0.278 28.3
13 264 50 0.263 28.6
AUX mode, pink noise signal input,
14 90 60 0.578 28.6
adjust volume to1/8 of Max. Non-
15 100 60 0.524 28.4 clipped output power on speakers.
16 240 60 0.273 28.1
17 264 60 0.257 28.2
SUB= SUB=
18 15 -- 0.55 8.2 1.11 0.31
L/R=1.04 L/R=0.14
19 90 50 0.588 29.1 SUB= SUB=
1.36 0.46
20 100 50 0.538 28.9
L/R=1.34 L/R=0.22
21 240 50 0.275 28.5
22 264 50 0.256 28.6
23 90 60 0.596 29.2 BT mode, pink noise signal input,
adjust volume to 1/8 non-clipped power
24 100 60 0.543 29.0
output on speakers, normal playing.
25 240 60 0.278 28.5
26 264 60 0.254 28.3
SUB= .08 SUB=
27 15 -- 0.56 8.4 L/R=1.05 0.29
L/R=0.14

Page 36 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

28 90 50 0.551 27.5 SUB= SUB= FM mode, pink noise signal input,


1.32 0.44
29 100 50 0.518 27.0 adjust volume to 1/8 non-clipped power
L/R=1.27 L/R=0.20
30 240 50 0.266 26.5 output on speakers, normal playing.

31 264 50 0.250 26.7


32 90 60 0.554 27.4
33 100 60 0.519 27.0
34 240 60 0.270 26.6
35 264 60 0.252 26.7
SUB= SUB=
36 15 -- 0.52 7.8 1.06 0.28
L/R=1.03 L/R=0.13
Loudspeaker impedance (Ω) ...................................
SUB: 4Ω : —
L/R: 8Ω
Several loudspeaker systems ..................................
Sub: 4Ωx1pcs : --
L/R: 8Ωx2pcs
Marking of loudspeaker terminals ............................
Internally integrated: --
Limit max dT
Temperature Rise dT of Part dT (K)
(K)
Supply voltage No.22 No.23 No.27 --
Power switch 4.7 4.9 3.5 50
Power cord (inside) 3.9 4.1 3.3 60
AC connector CON1 16.1 21.5 4.2 50

Coil of Line filter LF1 13.6 20.6 3.9 85

X-capacitor CX1 15.0 26.8 3.9 65

Coil of Line filter LF2 19.2 37.5 3.8 85

PCB near BD1 17.2 32.4 3.6 95


Electrolytic capacitor EC1 12.4 19.3 3.6 105

PCB near Q1 25.3 31.9 3.4 95

Opto-coupler U1 28.0 29.8 3.8 65

Winding of T1 40.9 38.1 3.8 75

Core of T1 33.8 31.6 3.6 75

Y-capacitor CY2 29.9 28.1 3.7 90

PCB near D1 57.4 54.2 4.0 95


Electrolytic capacitor EC4 37.6 35.3 4.1 105

PCB near IC5(on power amplifier board) 30.1 30.0 28.8 95


Coil of Line filter L306(on power amplifier
33.9 33.6 32.7 85
board)

Page 37 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

PCB near IC801(on power amplifier board) 24.4 24.4 23.0 95

PCB near BT module(on power amplifier board) 35.6 35.7 31.5 95

PCB near USB(on power amplifier board) 36.1 36.5 33.5 95

PCB near IC4(on power amplifier board) 56.8 56.4 49.7 95

Battery body 2.5 2.0 4.2 Ref.

Battery wire 2.4 2.0 4.3 45

Plastic enclosure near battery, inside 2.2 1.6 4.0 Ref.

Plastic enclosure near battery, outside 1.5 1.0 3.4 60

Top plastic enclosure, inside 10.5 11.4 11.7 Ref.

Top plastic enclosure, outside 8.6 10.0 10.7 60


Metal enclosure near T1, outside 7.8 8.1 2.3 40
Button 16.3 16.5 12.5 50
LED display 15.2 15.9 14.3 60

Ambient(C) 23.9 23.6 23.3 --


Winding temperature rise measurements
Ambient temperature t1 (C) …………….....: -- -- -- --
Ambient temperature t1 (C) …………….....: -- -- -- --
Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit max Insulation class
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) (K)
R1
-- -- -- -- -- --
-- -- -- -- -- --
Supplementary information:
1. Measurements were carried out with the apparatus positioned inside the box specified by the clause 4.1.4
of the standard.
2. According to the user manual, the appliance is intended to be used in moderate climate, so the basic
o
ambient temperature is 35 C.
3. All the heating test was performed under BT mode.
4. The USB as a signal input port only.
5. SUB: Subwoofer Speaker; L: Left Speaker; R : Right Speaker.

7.2 TABLE: softening temperature of thermoplastics N


Temperature T of part T – normal con- T – fault condi- Min T softening
ditions (C) tions (C) (C)
-- -- -- --
-- -- -- --
Supplementary information:
Phenolic materials used for LF2 and transformer T1 consider as having softening temperature of 150°C,
no other parts tested necessary.

Page 38 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

9.1.1.2 a) TABLE: Electric shock hazard under normal condition (open-circuit voltage) P
Open-circuit voltage Condition U (Vpk) U (Vpk) Limit
measured between:
L/N of plug to wooden
Normal condition 94 35
enclosure(with metal foil)
L/N of plug to plastic
Normal condition 104 35
enclosure (with metal foil)
L/N of plug to signals
Normal condition 192 35
terminal
Notes:
1. If the voltage limits are exceeded, table 9.1.1.2 b) apply.
2.Using item a) in clause 9.1.1.2 to determine the hazardous live parts.
3. Input 264Vac/60Hz.

9.1.1.2 b) TABLE: Electric shock hazard under normal condition (touch current) P

Touch current measured Condition U1 (V) U1 (Vpk) U2 (V) U2 (Vpk) Limited


between: Limit
L/N of plug to plastic
Normal condition 0.142 35 0.046 0.35
enclosure (with metal foil)
L/N of plug to Wooden
Normal condition 0.114 35 0.030 0.35
enclosure (with metal foil)
L/N of plug to signal
Normal condition 0.204 35 0.087 0.35
terminals
Supplementary information:
The touch current is measured according to 9.1.1.2 b) with the test circuit of Annex D connected between the
specified points. Input 264Vac/60Hz.

10.4 TABLE: Insulation Resistance Measurements P


Insulation resistance R between: R (M ) Required R (M )
Between L and N (fuse opened) >100 Min. 2
Between L&N and accessible terminals >100 Min. 4
Between L&N and wooden enclosure (with metal foil) >100 Min. 4
Between L&N and plastic enclosure (with metal foil) >100 Min. 4
Transformer T1 primary winding and secondary winding >100 Min. 4
Transformer T1 secondary winding and core >100 Min. 4
2 layer insulation tape of transformer >100 Min. 4
Supplementary information:
Triple insulated wire used for secondary winding of the transformer T1, Core of T1 considered as primary part.

10.4 TABLE: Dielectric Strength P

Page 39 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Test voltage applied between: Test potential applied Breakdown / flashover


(V) (Yes/No)
Between L and N (fuse opened) 1500Vac No
Between L&N and accessible terminals 3000Vac No
Between L&N and wooden enclosure (with metal foil) 3000Vac No
Between L&N and plastic enclosure (with metal foil) 3000Vac No
Transformer T1 primary winding and secondary winding 3000Vac No
Transformer T1 secondary winding and core 3000Vac No
2 layer insulation tape of transformer 3000Vac No
Supplementary information:
Triple insulated wire used for secondary winding of the transformer T1, core of T1 considered as primary part.

11.1 TABLE: Electric shock hazard under abnormal condition P


Touch current measured Condition U1 (V) U1 (Vpk) U2 (V) U2 (Vpk) Limit
between: Limit
L/N of plug to plastic
0.103 70 0.023 1.4
enclosure (with metal foil)
All fault condition
L/N of plug to Wooden
that cause fuse F1 0.074 70 0.017 1.4
enclosure (with metal foil)
opened
L/N of plug to signal
0.126 70 0.031 1.4
terminals
Supplementary information:
The touch current is measured according to 9.1.1.2 b) with the test circuit of Annex D connected between the
specified points. Input 264Vac/60Hz.

11.2 TABLE: Fault Conditions P


Voltage (V) 0,9 or 1,1times rated voltage ................ : See below --
Frequency (Hz) ......................................................... : 50 (for AC supply) --
Ambient temperature (C) ....................................... : 20-24C or see below --
No. Component Fault dT (K) /Component Test conditions, test duration, test
result
Supplied by AC input :
Input power increase to 34.7W. No
Speaker Max. non- See table for fault condition damaged, no hazards.
01.
output clipped temperature rise of part I/P: 264Vac, 0.328A, 34.7 W
Testing time: 3hours30mins
Apparatus temperature rise until
Ventilation See table for fault condition stability, no damaged, no hazards.
02. blocked
openings temperature rise of part I/P: 264Vac, 0.256 A, 28.6W
Testing time: 3hours30mins
Input power decrease to 23.4 W. No
Tweeter See table for fault condition damaged, no hazards.
03. S-C
speaker temperature rise of part I/P: 264Vac, 0.187A, 23.4 W
Testing time:3hours
Page 40 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Input power decrease to 22.8 W. No


Subwoofer See table for fault condition damaged, no hazards.
04. S-C
speaker temperature rise of part I/P: 264Vac, 0.176 A, 22.8 W
Testing time:3hours
USB shut down immediately, unit can
be recoverable when the fault
05. USB output S-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.143 A, 16.1 W
Test time:10min
Fuse F1 opened immediately, no
BD1 pin1- hazards.
06. S-C --
pin2 I/P: 264Vac, 0A, 0W.
Test time:10min
Fuse F1 opened immediately, no
hazards.
07 EC1 S-C --
I/P: 264Vac, 0A, 0W.
Test time: 1s
Unit shut down immediately, unit can
be recoverable when the fault
08. Q1S-G S-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.017A, 0.30W
Fuse F1 opened immediately, no
hazards.
09. Q1 D-S S-C --
I/P: 264Vac, 0A, 0W.
Test time: 1s
Fuse F1 opened immediately, no
hazards.
10. Q1 D-G S-C --
I/P: 264Vac, 0A, 0W.
Test time: 1s
Unit shut down immediately, unit can
be recoverable when the fault
U1 Pin1- removed. No damage, no hazards.
11. S-C --
Pin2
I/P: 264Vac, 0.017A, 0.30W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
U1 Pin3- removed. No damage, no hazards.
12. S-C --
Pin4
I/P: 264Vac, 0.017A, 0.30W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
13. U1 Pin1 O-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.017A, 0.30W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
14 U1 Pin3 O-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.017A, 0.30W
Test time:10min
15. T1 Pin4- S-C -- Unit shut down immediately, unit can
Page 41 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Pin6 be recoverable when the fault


removed. No damage, no hazards.
I/P: 264Vac, 0.019A, 0.34W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
T1 Pin1- removed. No damage, no hazards.
16. S-C --
Pin2
I/P: 264Vac, 0.019A, 0.34W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
T1 Pin7/8- removed. No damage, no hazards.
17. S-C --
Pin11/12
I/P: 264Vac, 0.019A, 0.34W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
18. D1 S-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.017A, 0.30W
Test time:10min
Unit shut down immediately, unit can
be recoverable when the fault
19 EC4 S-C -- removed. No damage, no hazards.
I/P: 264Vac, 0.017A, 0.30W
Test time:10min

Supplied by internal battery:

Input power increase to 19.2W. No


Speaker Max. non- See fault condition temperature rise damaged, no hazards.
20
output clipped dT of part Internal battery: 15Vdc,1.28A,19.2W
Testing time:3hours30mins
Input power decrease to 13.8 W. No
Tweeter See fault condition temperature rise damaged, no hazards.
21 S-C
speaker dT of part Internal battery:15Vdc, 0.91 A,13.7 W
Testing time:3hours
Input power decrease to 13.7 W. No
Subwoofer See fault condition temperature rise damaged, no hazards.
22 S-C
speaker dT of part Internal battery:15Vdc, 0.92 A,13.8 W
Testing time:3hour
Supplementary information:
1. After each of above test, unit can pass the dielectric strength test specified in table 10.4
2. Used abbreviations: S-C=short circuit, O-C=open circuit, O-L=overload, B-L=block ventilation openings,
I/P=input current/input power.
3. For fault where opened, the current through the fuse exceed 2.1 times fuse rating, All source of fuse used
with same result.

TABLE: Temperature Rise Measurements Under Abnormal Condition Tests


Test condition No.01 No.02 No.03 No.04 No.06 --
Temperature Rise dT of Limit dT
dT (K)
Part (K)
Power switch 7.8 5.8 7.1 6.8 6.1 Ref
Page 42 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Power cord (inside) 6.8 4.8 6.4 6.1 4.9 100


AC connector CON1 20.2 18.3 17.2 16.6 17.0 Ref
Coil of Line filter LF1 17.5 15.7 15.0 14.5 14.5 150
X-capacitor CX1 18.9 17.3 16.4 15.8 16.0 Ref
Coil of Line filter LF2 23.3 22.1 20.3 19.5 20.1 150
PCB near BD1 21.0 19.8 18.6 17.9 18.2 110
Electrolytic capacitor EC1 16.1 14.7 14.3 13.7 13.4 Ref
PCB near Q1 29.6 28.5 25.9 25.1 26.1 110
Opto-coupler U1 32.8 31.0 28.4 27.6 29.0 Ref
Winding of T1 47.9 45.5 40.4 39.2 41.5 140
Core of T1 39.3 37.5 33.9 33.0 34.5 140
Y-capacitor CY2 34.7 33.2 30.6 29.7 30.7 Ref
PCB near D1 67.9 63.5 55.6 54.0 58.1 110
Electrolytic capacitor EC4 44.5 42.0 37.5 36.4 38.7 Ref
PCB near IC5(on power
32.7 32.2 32.6 32.3 31.7 110
amplifier board)
Coil of Line filter L306(on
36.2 35.5 36.2 36.0 35.2 150
power amplifier board)
PCB near IC801(on
25.6 26.2 25.4 24.7 25.4 110
power amplifier board)
PCB near BT module(on
42.9 42.4 35.9 34.7 36.8 110
power amplifier board)
PCB near USB(on power
51.1 46.3 36.2 35.2 39.9 110
amplifier board)
PCB near IC4(on power
90.1 77.5 47.7 45.7 61.8 110
amplifier board)
Battery body 4.3 2.8 5.5 4.6 4.5 Ref
Battery wire 4.5 2.9 5.3 4.6 4.2 100
Plastic enclosure near
3.8 2.5 5.2 4.4 4.1 Ref
battery, inside
Plastic enclosure near
2.6 1.6 4.3 3.6 3.3 65
battery, outside
Top plastic enclosure,
15.5 15.0 13.5 13.1 10.7 Ref
inside
Top plastic enclosure,
14.5 13.3 12.2 11.9 8.8 65
outside
Metal enclosure near T1,
12.3 9.4 10.0 9.8 9.7 65
outside
Button 18.6 17.4 17.9 17.4 17.3 65
LED display 20.0 16.9 18.5 18.1 18.5 65
Ambient(C) 20.3 22.5 21.7 21.7 23.4 --

Page 43 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Winding temperature rise measurements N


o
Ambient temperature t1 ( C) ................................... : -- —
o
Ambient temperature t2 ( C) ................................... : -- —
Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT Insulation
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) (K) class
R1
-- -- -- -- -- --
-- -- -- -- -- --

TABLE: Temperature Rise Measurements Under Abnormal Condition Tests


Test condition No.21 No.22 No.23 -- -- --
Temperature Rise dT of Limit dT
dT (K)
Part (K)
Power switch 5.5 2.6 2.9 -- -- Ref
Power cord (inside) 5.2 2.5 2.8 -- -- 100
AC connector CON1 6.6 3.2 3.5 -- -- Ref
Coil of Line filter LF1 6.0 3.0 3.4 -- -- 150
X-capacitor CX1 6.0 3.0 3.3 -- -- Ref
Coil of Line filter LF2 6.0 2.9 3.3 -- -- 150
PCB near BD1 5.6 2.8 3.1 -- -- 110
Electrolytic capacitor EC1 5.7 2.8 3.2 -- -- Ref
PCB near Q1 5.6 2.5 2.9 -- -- 110
Opto-coupler U1 6.2 2.9 3.2 -- -- Ref
Winding of T1 5.9 2.7 3.1 -- -- 140
Core of T1 6.1 2.9 3.2 -- -- 140
Y-capacitor CY2 5.8 2.8 3.1 -- -- Ref
PCB near D1 6.1 3.1 3.4 -- -- 110
Electrolytic capacitor EC4 6.3 3.1 3.5 -- -- Ref
PCB near IC5(on power
33.9 30.1 30.2 -- -- 110
amplifier board)
Coil of Line filter L306(on
37.9 33.9 34.0 -- -- 150
power amplifier board)
PCB near IC801(on
28.0 23.9 24.0 -- -- 110
power amplifier board)
PCB near BT module(on
36.1 30.3 30.0 -- -- 110
power amplifier board)
PCB near USB(on power
38.0 30.6 30.4 -- -- 110
amplifier board)
PCB near IC4(on power
52.7 42.3 42.0 -- -- 110
amplifier board)

Page 44 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Battery body 5.6 1.3 1.6 -- -- Ref


Battery wire 5.9 1.4 1.7 -- -- 100
Plastic enclosure near
5.2 1.1 1.4 -- -- Ref
battery, inside
Plastic enclosure near
4.7 0.5 0.7 -- -- 65
battery, outside
Top plastic enclosure,
13.3 12.1 12.1 -- -- Ref
inside
Top plastic enclosure,
12.1 10.8 10.8 -- -- 65
outside
Metal enclosure near T1,
6.7 3.5 3.7 -- -- 65
outside
Button 20.7 17.7 17.8 -- -- 65
LED display 16.0 15.5 15.6 -- -- 65
Ambient(C) 20.3 20.6 20.9 -- -- --

Winding temperature rise measurements N


o
Ambient temperature t1 ( C) ................................... : -- —
o
Ambient temperature t2 ( C) ................................... : -- —
Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT Insulation
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) (K) class
R1
-- -- -- -- -- --
-- -- -- -- -- --

13.2 WORKING VOLTAGE MEASUREMENT P


Location RMS Voltage (V) Peak Voltage Comments
(V)
CY1 Primary pin- Secondary 220 384 --
U1 Pin1- Pin3 232 368 --
U1 Pin1- Pin4 232 368 --
U1 Pin2- Pin3 232 368 --
U1 Pin2- Pin4 232 368 --
T1 Pin 1- Pin7/8 221 353 --
T1 Pin 2- Pin7/8 222 424 --
T1 Pin 4- Pin7/8 236 416 Max. Vrms of T1
T1 Pin 6- Pin7/8 219 352 --
T1 Pin 1- Pin11/12 223 376 --
T1 Pin 2- Pin11/12 222 392 --
T1 Pin 4- Pin11/12 229 408 --
T1 Pin 6- Pin11/12 219 432 Max.Vpeak of T1
Page 45 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Supplementary information:
The unit connected to RATED SUPPLY VOLTAGE 240Vac/ dc, 60Hz, and working under normal condition.

13.3&13.4 TABLE: Clearance ad Creepage Distance Measurements P


Rated supply 100-240Vac Pollution degree .. : II Material Group ....: IIIa or IIIb
voltage:
2 N force on internal parts applied: Component Yes
30 N force on outside of conductive enclosure
Metal enclosure Yes
applied:
clearance and creepage distance Working voltage (V) Clearance (mm) Creepage (mm)
at/of:
U peak U r.m.s. Required Measured required Measured
Different polarity of L &N before
<420 <250 2.0 3.0 2.5 3.0
fuse F1 (BI)
Different polarity of fuse (BI) <420 <250 2.0 2.6 2.5 2.6
CY1 capacitor primary to secondary
<420 <250 4.0 6.5 5.0 6.5
(RI)
Optocoupler U1 primary to
<420 <250 4.0 5.5 5.0 5.5
secondary (RI)
Transformer T1 primary to
432 <250 4.2 5.8 5.0 5.8
secondary on PCB Layout (RI)
Transformer T1 primary winding to
432 <250 4.2 6.0 5.0 6.5
secondary pins (RI)
Transformer T1 core to
432 <250 4.2 6.0 5.0 6.2
secondary pins (RI)

Primary part to metal plastic (RI) 432 <250 4.2 >4.2 5.0 >5.0

Supplementary information:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna
signal input), are subjected to the requirements for circuits conductively connected to the mains in Tables 8
and 9.
2. For insufficient clearances and creepage distances from secondary to secondary circuits and from
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
3. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or
10 as required, then the value for clearance is used as the minimum creepage distance .
“Min” = minimum required. “Actual = Actual dimensions measured.
4. BI=Basic insulation; SI=Supplementary insulation; RI=Reinforce insulation
5. Triple insulated wire used for secondary winding of the transformer T1, core of T1 considered as primary
part.

Page 46 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

14 TABLE: Critical components information P


Object / part Manufacturer/ Type / model Technical data Standard Mark(s) of
No. trademark conformity*)
Shenzhen Xiekang DIN VDE 0620
Power plug XK-01 2.5A, 250Vac VDE: 40009009
Electric Co., Ltd. EN 50075
DIN VDE 0620
(Alternate) Interchangeable Interchangeable 2.5A, 250Vac VDE
EN 50075
DIN EN 50525-2-
Shenzhen Xiekang 2 x 0.5 mm²or 11
Power cord H03VVH2-F VDE: 40029225
Electric Co., Ltd. 2 x 0.75mm²
EN 50525-2-11
DIN EN 50525-2-
2 x 0.5 mm²or 11
(Alternate) Interchangeable Interchangeable VDE
2 x 0.75mm²
EN 50525-2-11

Power Shenzhen Xiekang DIN EN 60320-1


XK-05 250 V~, 2.5 A VDE: 40018650
connector Electric Co., Ltd. EN 60320-1
DIN EN 60320-1
(Alternate) Interchangeable Interchangeable 250 V~, 2.5 A VDE
EN 60320-1
Zhe Jiang Bei Er DIN EN 60320-1
Appliance
Jia Electronic Co., ST-A03-002 250 V~, 2.5 A VDE: 40014833
inlet EN 60320-1
Ltd.
DIN EN 60320-1
(Alternate) Interchangeable Interchangeable 250 V~, 2.5 A VDE
EN 60320-1

Zhongxun
6A, 250Vac or
Power switch Electronics KCD1-104 EN 61058-1 TUV: R 50049218
10A, 250Vac
Industry Company

Yueqing
Huansheng EN 61058-1
(Alternate) KCD-117 6A, 250Vac VDE: 40024304
Electronics Co., IEC 61058-1
Ltd.
Zhejiang
Zhongxun TUV:
(Alternate) KCD1-B3 6A, 250Vac EN 61058-1
Electronics Co., AN 50190770
Ltd.
FORMOSA
Plastic CHEMICALS & HB, 60°C, Min.
AG15A1 UL 94 UL: E162823
material FIBRE CORP thickness 1.5 mm
PLASTICS DIV
Wooden Min. thickness 6.0 Tested with
Interchangeable Interchangeable IEC/EN 60065
enclosure mm appliance
Heat
DONGGUAN SALIPT S-901-
Shrinkable 600V, 125°C UL 224 UL: E209436
SALIPT CO LTD 600
tube
SHENZHEN CITY VW-1, 105°C,
Internal AC DE XING LONG 300V,
1672 UL 758 UL: E328945
wire ELECTRIC CO
LTD 22AWG

Page 47 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

VW-1, Min.105°C,
(Alternate) Interchangeable 1672 Min.300V, UL 758 UL
Min. 22AWG
CHEERFUL V-0, 130°C, UL 94
PCB INDUSTRIAL (HK) CC-3 Min. thickness UL: E141796
LTD 1.6mm UL 796

Min. V-0, 130°C, UL 94


(Alternate) Interchangeable Interchangeable Min. thickness UL
1.6mm UL 796

UL 248-1
XC Electronics EN 60127-1
UL: E249609
Fuse (F1) (Shen Zhen) Corp. 3T-Serie(s) T3.15AL, 250Vac EN 60127-3
Ltd. VDE: 40019614
IEC 60127-1
IEC 60127-3
ZHEJIANG JINDA
AC connector
ELECTRONICS 3.96T-02 7A, 250VAC, 85°C UL 1977 UL: E237523
(CON1)
CO LTD

275 Vac, UL 60384-14


X-capacitor Winday Electronic UL: E302125
MPX Max. 0.22uF, EN 60384-14
(CX1) Industrial Co., Ltd VDE: 40030283
100°C IEC 60384-14

400Vac, Y1 type, UL 60384-14


Y1 Capacitor Zonkas Electronic UL: E258931
ZD Max. 2200pF, EN 60384-14
(CY1) Co., Ltd. VDE: 40017350
125°C. IEC 60384-14
Shantou High-New
Technology Dev. 400Vac, Y1 type, UL 60384-14
UL: E208107
(Alternate) Zone Songtian CD Max. 2200pF, EN 60384-14
Enterprise Co., 125°C. VDE: 40025754
IEC 60384-14
Ltd.

400Vac, Y1 type, UL 60384-14


Shenzhen Haotian UL: E326483
(Alternate) HT Max. 2200pF, EN 60384-14
Electronic Co., Ltd. VDE: 40029300
125°C. IEC 60384-14
Dti=0.5mm, UL 1577
Everlight UL: E214129
Optocoupler Int. dcr=6.0mm,
Electronics Co., EL817 EN 60747-5-5
(U1) Ext. dcr=7.7mm, VDE: 132249
Ltd. IEC 60747-5-5
110C
Bleeder
resistors(R3, Interchangeable Interchangeable Max. 1MΩ, 1/4W -- --
R4)
E-capacitors Max. 68uF, Min.
Interchangeable Interchangeable -- --
(EC1) 450V, Min. 105°C
Rectifier Min. 3.0A, Min.
Interchangeable Interchangeable -- --
(BD1) 700V
--
Min. 5.5A, Min.
MOS(Q1) Interchangeable Interchangeable --
650V

Line filter SHENZHEN CKTC100604- 130ºC IEC/EN 60065 Tested with


Page 48 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

(LF1) CENKER 35uH/P-A2863 appliance


ENTERPRISE
LTD.
TAI-I ELECTRIC
Copper magnet
--Magnet wire WIRE & CABLE UEW UL 1446 UL: E85640
wire, Min. 130ºC
CO LTD

--Multi-layer IEC 60950-1,


Suzhou Yusheng VDE: 40033527
Insulated TIW-B, TWE-3 130C EN 60950-1
Electronic Co., Ltd. UL: E332529
Winding UL 60950-1
B&M Magnetism
Line filter Tested with
Technology UU10.5-18mH 130ºC IEC/EN 60065
(LF2) appliance
Limited
CHANG CHUN Phenolic, V-0, UL 94,
--Bobbin PLASTICS CO., T375J 150ºC, Min. UL: E59481
LTD 0.75mm thickness UL 746C

BOLUO COUNTY
--Magnet XIN LONG
2UEW 130ºC UL 1446 UL: E229423
wire ELECTRICIAN
DATA CO LTD
(Alternate) Interchangeable Interchangeable Min. 130C UL 1446 UL
HANG CHEUNG
--Varnish PETROCHEMICA 8562/D 155ºC UL 1446 UL: E200154
L LTD
SHENZHEN HUA
XINGJINGCHENG
Transformer Tested with
ELECTRONIC 19019 REV1.1 Class B IEC/EN 60065
(T1) appliance
TECHNOLOGY
CO..LTD
CHANG CHUN Phenolic, V-0, UL 94,
--Bobbin PLASTICS CO T375J 150ºC, Min. UL: E59481
LTD 0.75mm thickness UL 746C

PACIFIC
--Magnet ELECTRIC WIRE
& CABLE UEW/U@ 130C UL 1446 UL: E201757
wire (SHENZHEN) CO
LTD
SHANTOU
SHENGANG
(Alternate) ELECTRICAL 2UEW/130 130C UL 1446 UL: E239508
INDUSTRIAL CO
LTD
PACIFIC
ELECTRIC WIRE
(Alternate) & CABLE UEWN/U@ 155C UL 1446 UL: E201757
(SHENZHEN) CO
LTD
UL
(Alternate) Interchangeable Interchangeable Min. 130C UL 1446

--Insulation JINGJIANG PZ-280 130C UL 510 UL: E165111


Page 49 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
CHANG SHU
LIANG YI TAPE
(Alternate) LY-02A(h) 130C UL 510 UL: E246820
INDUSTRY CO
LTD
SUZHOU
MAILADUONA
(Alternate) ELECTRIC JY312# 130C UL 510 UL: E188295
MATERIAL CO
LTD

--Multi-layer IEC 60950-1,


Suzhou Yusheng VDE: 40033527
Insulated TIW-B, TWE-3 130C EN 60950-1
Electronic Co., Ltd. UL: E332529
Winding UL 60950-1
CHANGYUAN
--Tube ELECTRONICS CB-TT-T 300Vac, 200C UL 224 UL: E180908
GROUP CO LTD

--Margin Tape WF-2902 WF-2902 130C UL 510 UL: E165111

Lead Acid FLYING POWER


GS12V7AH 12V, 7AH UL 1989 UL: MH27904
Battery (JIANGXI) CO LTD

L/R speaker: 8Ω,


8W Tested with
Speakers Interchangeable Interchangeable IEC/EN 60065
Subwoofer appliance
Speaker: 4Ω, 50W
*)Provided evidence ensures the agreed level of compliance.
Supplementary information: “Interchangeable” means any type from any manufacturer that complies with the
specification can be used.

Page 50 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo documentation
Photo 1

Photo 2

Page 51 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 3

Photo 4

Page 52 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 5

Photo 6

Page 53 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 7

Photo 8

Page 54 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 9

Photo 10

Page 55 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 11

Photo 12

Page 56 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 13

Photo 14

Page 57 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 15

Photo 16

Page 58 of 59
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711197SV00

Photo 17

Photo 18

--- END OF THIS REPORT---