0% found this document useful (0 votes)
111 views3 pages

Compact NS - 33480

The document provides specifications for a 1250A, 4-pole circuit breaker with a Micrologic 2.0 trip unit. It lists the breaker's key characteristics including its voltage and current ratings, breaking capacity, dimensions, certifications, and environmental specifications. The breaker is designed for distribution applications in AC networks ranging from 50/60Hz.

Uploaded by

ricky kurniawan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views3 pages

Compact NS - 33480

The document provides specifications for a 1250A, 4-pole circuit breaker with a Micrologic 2.0 trip unit. It lists the breaker's key characteristics including its voltage and current ratings, breaking capacity, dimensions, certifications, and environmental specifications. The breaker is designed for distribution applications in AC networks ranging from 50/60Hz.

Uploaded by

ricky kurniawan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Product data sheet 33480

Characteristics circuit breaker Compact NS1250N - Micrologic 2.0


- 1250 A - 4 poles 4t

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range Compact
Range of product NS630b...1600
Product or component type Circuit breaker
Device short name Compact NS1250N
Device application Distribution
Poles description 4P
Protected poles description 4t
Neutral position Left
Network type AC
Breaking capacity code N
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name Micrologic 2.0
Trip unit technology Electronic
Trip unit rating 1250 A ( 50 °C )

Complementary
Network frequency 50/60 Hz
Control type Rotary handle
Toggle
Mounting mode Fixed
Mounting support Backplate
Upside connection Front
Downside connection Front
[In] rated current 1250 A ( 50 °C )
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2

Dec 26, 2018


1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 1250 A
Breaking capacity 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity Ics 30 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Ics 40 kA 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Auxiliary contact composition 1 NO/NC
Mechanical durability 10000 cycles
Electrical durability 2000 cycles IEC 60947-2 690 V In AC 50/60 Hz
3000 cycles IEC 60947-2 690 V In/2 AC 50/60 Hz
4000 cycles IEC 60947-2 440 V In AC 50/60 Hz
5000 cycles IEC 60947-2 440 V In/2 AC 50/60 Hz
Local signalling Positive contact indication
[Icw] rated short-time withstand current 19.2 kA
Neutral protection setting Ir
Trip unit protection functions LI
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.4...1 x In
Long time delay adjustment type Adjustable 9 settings
[Tr] long-time delay adjustment range 0.5...24 s 6 x Ir
0.7...16.6 s 7.2 x Ir
12.5...600 s 1.5 x Ir
Thermal memory 20 mn
Instantaneous pick-up adjustment type Adjustable
Ii
Instantaneous pick-up adjustment 1.5...10 x Ir
range
Integral instant protection 40 kA
Height 327 mm
Width 280 mm
Depth 147 mm

Environment
Standards IEC 60947-2
Product certifications ASEFA
ASTA
Power losses 44 W
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Pollution degree 3 conforming to IEC 60947
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -50...85 °C

Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1622 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold

2
Product environmental profile Available
End of Life Information
Product end of life instructions Need no specific recycling operations

Contractual warranty
Warranty period 18 months