pm30 Operators Manual
pm30 Operators Manual
pm30 Operators Manual
9-52 Ashihara-cho,
Nishinomiya 662-8580, JAPAN
Telephone : 0798-65-2111
Fax : 0798-65-4200
*OME30200M00*
*OME30200M00*
*OME30200M00*
2.4 Adjustment at Installation
The PM-30 monitors the performance of a radar set by comparing its present performance
with the initial performance achieved at installation. In order to establish good reference of
comparisons, and eventual high-accuracy indications, the PM-30 must be properly adjusted
at installation.
Adjustment Procedure
1. Confirm the front cover of the Performance Monitor is firmly secured with 8 fixing
screws. (If not, microwave leakage will occur, resulting in misadjustment of attenuator
ATT02 and eventual poor indicating accuracy.) Note that it is prohibited to open the front
cover.
2. Remove the cap bolts of attenuators ATT01 (RX) and ATT02 (TX) provided on the top
side of the Performance Monitor.
6. Operating the VRM control, measure the range to the innermost arc displayed on the
radar screen.
7. Adjust attenuator ATT01 of the receiving circuit so that the innermost arc is displayed
within the range 12 ±0.5 nm. Clockwise rotation of ATT01 increases the range;
counterclockwise rotation decreases it.
Note: Arcs may disappear or freeze when the attenuator setting is out of the adjustment
range, and adjustment of the attenuator alone cannot clear the problem. In this case,
turn the attenuator fully counterclockwise, turn it about 1 1/2 turns and then turn
the power off and on again. Adjust the attenuator slowly in about 5 degree turns; a
slight turn yields large change.
8. Adjust transmitting circuit’s attenuator ATT02 so that the outermost arc (4th from inside)
is slightly visible. Clockwise rotation of ATT02 increases the intensity of the arcs;
counterclockwise rotation decreases it.
12
APPENDIX
Installation of PM-30 on the Antenna Unit
Fix the mounting assy. to the antenna unit chassis when you cannot mount PM-30 near the
antenna unit.
PM-30 (RSB-0041/0042/0043/0046/0076/0077/0078/0074-I*/0075-I*)
Type: FP03-07210, Code No. 000-030-250
A-1
Assembling and Mounting Procedure
The procedure for assembling and mounting the Performance Monitor on the antenna unit is as
follows.
Hanger Bracket
M5X12
M8X20
Mounting Plate
For RSB-0014/0064/0074/0075
Hanger Bracket
M5X12
M8X20
Mounting Plate
For RSB-0041/0042/0043/0046/0074-I/0075-I/0076/0077/0078
A-2