Getting Started With LabVIEW
Getting Started With LabVIEW
TM
Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Worldwide Offices Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545 For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments Web site at ni.com/info and enter the info code feedback. 20032009 National Instruments Corporation. All rights reserved. Austin, Texas 78759-3504 USA Tel: 512 683 0100
Important Information
Warranty
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty. National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it. EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owners failure to follow the National Instruments installation, operation, or maintenance instructions; owners modification of the product; owners abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control.
Copyright
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation. National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction. For copyright notices, conditions, and disclaimers, including information regarding certain third-party components used in LabVIEW, refer to the Copyright topic of the LabVIEW Help.
Trademarks
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. FireWire is the registered trademark of Apple Inc. Other product and company names mentioned herein are trademarks or trade names of their respective companies. Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, partnership, or joint-venture relationship with National Instruments.
Patents
For patents covering National Instruments products/technology, refer to the appropriate location: HelpPatents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.
Contents
About This Manual
Conventions ...................................................................................................................ix Related Documentation..................................................................................................x
Chapter 2 Customizing a VI
Building a VI from a Blank VI ......................................................................................2-1 Opening a Blank VI.........................................................................................2-2 Adding an Express VI That Simulates a Signal ..............................................2-2 Searching the Help and Modifying a Signal....................................................2-3 Customizing a User Interface from the Block Diagram..................................2-4 Configuring a VI to Run Continuously until the User Stops It .......................2-6 Using the Error List Window ..........................................................................2-7 Controlling the Speed of Execution ................................................................2-8
Contents
Using a Table to Display Data ........................................................................ 2-9 Searching for Examples .................................................................................. 2-10 Summary........................................................................................................................ 2-12 Using the LabVIEW Help Resources ............................................................. 2-12 Customizing the Block Diagram Code ........................................................... 2-13 Creating Controls and Indicators ...................................................... 2-13 Controlling When a VI Stops Running............................................. 2-13 Errors and Broken Wires .................................................................. 2-13 Displaying Data in a Table ............................................................... 2-14 Using the NI Example Finder ......................................................................... 2-14 Shortcuts.......................................................................................................... 2-14
vi
ni.com
Contents
vii
Conventions
The following conventions appear in this manual: The symbol leads you through nested menu items and dialog box options to a final action. The sequence FilePage SetupOptions directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a tip, which alerts you to advisory information. This icon denotes a note, which alerts you to important information. bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names, controls and indicators on the front panel, dialog boxes, sections of dialog boxes, menu names, and palette names. Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, operations, variables, filenames, and extensions.
italic
monospace
ix
monospace bold
Bold text in this font denotes the messages and responses that the computer automatically prints to the screen. This font also emphasizes lines of code that are different from the other examples. Text in this font denotes a specific platform and indicates that the text following it applies only to that platform.
(Mac OS) Press <Command>-click to perform the same action as a
Platform
right-click
right-click.
Related Documentation
The following documents contain information that you may find helpful as you read this manual: LabVIEW Release NotesUse these release notes to install and uninstall LabVIEW. The release notes also describe the system requirements for the LabVIEW software, including the LabVIEW Application Builder. LabVIEW HelpUse the LabVIEW Help to access information about LabVIEW programming concepts, step-by-step instructions for using LabVIEW, and reference information about LabVIEW VIs, functions, palettes, menus, tools, properties, methods, events, dialog boxes, and so on. The LabVIEW Help also lists the LabVIEW documentation resources available from National Instruments. Access the LabVIEW Help by selecting HelpSearch the LabVIEW Help. LabVIEW Quick Reference CardUse this card as a reference for information about help resources, keyboard shortcuts, data type terminals, and tools for editing, execution, and debugging.
ni.com
LabVIEW programs are called virtual instruments, or VIs, because their appearance and operation imitate physical instruments, such as oscilloscopes and multimeters. LabVIEW contains a comprehensive set of tools for acquiring, analyzing, displaying, and storing data, as well as tools to help you troubleshoot code you write. In LabVIEW, you build a user interface, or front panel, with controls and indicators. Controls are knobs, push buttons, dials, and other input mechanisms. Indicators are graphs, LEDs, and other output displays. After you build the user interface, you add code using VIs and structures to control the front panel objects. The block diagram contains this code. You can use LabVIEW to communicate with hardware such as data acquisition, vision, and motion control devices, as well as GPIB, PXI, VXI, RS232, and RS485 instruments.
1-1
Chapter 1
1-2
ni.com
Chapter 1
Launching LabVIEW
The Getting Started window, shown in Figure 1-2, appears when you launch LabVIEW. Use this window to create new VIs, select among the most recently opened LabVIEW files, find examples, and launch the LabVIEW Help. You also can access information and resources to help you learn about LabVIEW, such as specific manuals, help topics, and resources on the National Instruments Web site, ni.com.
The Getting Started window disappears when you open an existing file or create a new file. The Getting Started window reappears when you close all open front panels and block diagrams. You also can display the window from the front panel or block diagram by selecting ViewGetting Started Window.
1-3
Chapter 1
1-4
ni.com
Chapter 1
4.
Click the OK button to create a VI from the template. You also can double-click the name of the template VI in the Create New list to create a VI from a template. LabVIEW displays two windows: the front panel window and the block diagram window.
5.
Examine the front panel window. The user interface, or front panel, appears with a gray background and includes controls and indicators. The title bar of the front panel indicates that this window is the front panel for the Generate and Display VI.
1-5
Chapter 1
If the front panel is not visible, you can display the front panel by selecting WindowShow Front Panel. You also can switch between the front panel window and block diagram window at any time by pressing the <Ctrl-E> keys. The <Ctrl> key in keyboard shortcuts corresponds to the (Mac OS) <Option> or <Command> key or (Linux) <Alt> key.
Note
6.
Select WindowShow Block Diagram and examine the block diagram of the VI. The block diagram appears with a white background and includes VIs and structures that control the front panel objects. The title bar of the block diagram indicates that this window is the block diagram for the Generate and Display VI.
7.
On the front panel toolbar, click the Run button, shown at left. You also can press the <Ctrl-R> keys to run a VI. A sine wave appears on the graph on the front panel. Stop the VI by clicking the STOP button, shown at left, on the front panel.
8.
1.
If the Controls palette, shown in Figure 1-4, is not visible on the front panel, select ViewControls Palette.
Tip
You can right-click any blank space on the front panel or the block diagram to display a temporary version of the Controls or Functions palette. The Controls or Functions palette appears with a thumbtack icon in the upper left corner. Click the thumbtack to pin the palette so it is no longer temporary.
1-6
ni.com
Chapter 1
2.
If you are a new LabVIEW user, the Controls palette opens with the Express palette, shown in Figure 1-4, visible by default. If you do not see the Express palette, click Express on the Controls palette to display the Express palette.
3.
Move the cursor over the icons on the Express palette to locate the Numeric Controls palette. When you move the cursor over icons on the Controls palette, the name of the subpalette, control, or indicator appears in a tip strip below the icon.
Some palette objects display a short name on the palette that is different from the name that appears in the tip strip. The short name abbreviates the name of the palette object so that it fits in the space available on the palette. If you have difficulty finding a palette object by its short name, use the Search button on the Controls or Functions palette to find the palette object by name.
Note
4. 5.
Click the Numeric Controls icon to display the Numeric Controls palette. Click the Knob control on the Numeric Controls palette to attach the control to the cursor, and then add the knob to the front panel to the left of the waveform graph. You will use this knob in a later exercise to control the amplitude of a signal.
6.
Select FileSave As and save the VI as Acquiring a Signal.vi in an easily accessible location.
1-7
Chapter 1
1-8
ni.com
Chapter 1
4. 5.
Click the OK button to save the current configuration and close the Configure Simulate Signal dialog box. Move the cursor over the down arrows at the bottom of the Simulate Signal Express VI. The down arrows indicate you can reveal hidden inputs and outputs by extending the border of the Express VI. When a double-headed arrow appears, shown at left, click and drag the border of the Express VI to add two rows. When you release the border, the Amplitude input appears. Because the Amplitude input appears on the block diagram, you can configure the amplitude of the sawtooth wave on the block diagram. In Figure 1-5, notice that Amplitude is an option in the Configure Simulate Signal dialog box. When inputs, such as Amplitude, appear on the block diagram and in the configuration dialog box, you can configure the inputs in either location.
6.
1-9
Chapter 1
You can resize only loops and structures on the block diagram. Go to the front panel to resize objects you have added to the front panel. 2. Use the Positioning tool to select the Knob terminal and make sure it is to the left of the Simulate Signal Express VI and inside the gray loop, shown at left. The terminals inside the loop are representations of front panel controls and indicators. Terminals are entry and exit ports that exchange information between the front panel and block diagram. 3. Deselect the Knob terminal by clicking a blank space on the block diagram. If you want to use a different tool with an object, you must deselect the object to switch the tool. Move the cursor over the arrow on the Knob terminal, shown at left. The cursor becomes a wire spool, or the Wiring tool, shown at left. Use the Wiring tool to wire objects together on the block diagram. 5. When the Wiring tool appears, click the arrow on the Knob terminal and then click the arrow on the Amplitude input of the Simulate Signal Express VI, shown at left, to wire the two objects together. A wire appears and connects the two objects. Data flows along this wire from the Knob terminal to the Express VI. 6. Select FileSave to save the VI.
4.
1-10
ni.com
Chapter 1
Running a VI
Running a VI executes the solution. Complete the following steps to run the Acquiring a Signal VI. 1. 2. 3. Display the front panel by pressing the <Ctrl-E> keys or by clicking the front panel. Click the Run button or press the <Ctrl-R> keys to run the VI. Move the cursor over the knob. The cursor becomes a hand, or the Operating tool, shown at left. Use the Operating tool to change the value of a control. 4. Using the Operating tool, turn the knob to adjust the amplitude of the sawtooth wave. The amplitude of the sawtooth wave changes as you turn the knob. As you change the amplitude, the Operating tool displays a tip strip that indicates the numeric value of the knob. The y-axis on the graph scales automatically to account for the change in amplitude. To indicate that the VI is running, the Run button changes to a darkened arrow, shown at left. You can change the value of most controls while a VI runs, but you cannot edit the VI in other ways while the VI runs. 5. Click the STOP button, shown at left, to stop the VI. The STOP button stops the VI after the VI completes the current iteration. The Abort Execution button, shown at left, stops the VI immediately, before the VI finishes the current iteration. Aborting a VI that uses external resources, such as external hardware, might leave the resources in an unknown state by not resetting or releasing them properly. Design the VIs you create with a stop button to avoid this problem.
Modifying a Signal
Complete the following steps to scale the signal by 10 and display the results in the graph on the front panel. 1. On the block diagram, use the Positioning tool to double-click the wire that connects the Simulate Signal Express VI to the Waveform Graph terminal, shown at left. Press the <Delete> key to delete this wire.
2.
1-11
Chapter 1
3.
If the Functions palette, shown in Figure 1-6, is not visible, select ViewFunctions Palette to display it. The Functions palette opens with the Express palette visible by default. If you have selected another palette, you can return to the Express palette by clicking Express on the Functions palette.
4.
On the Arithmetic & Comparison palette, select the Formula Express VI, shown at left, and place it on the block diagram inside the loop between the Simulate Signal Express VI and the Waveform Graph terminal. You can move the Waveform Graph terminal to the right to make more room between the Express VI and the terminal. The Configure Formula dialog box appears when you place the Express VI on the block diagram. When you place an Express VI on the block diagram, the configuration dialog box for that VI always appears automatically.
Note
If you place an object too close to another object on the block diagram, auto wiring might wire the two objects together. Delete the wires if the automatic wiring is wrong. To configure auto wiring select ToolsOptions then select Block Diagram from the Category list. Remove the checkmark from the Enable auto wiring checkbox to turn off auto wiring. 5. Click the Help button, shown at left, in the bottom right corner of the Configure Formula dialog box to display the LabVIEW Help topic for this Express VI. The Formula help topic describes the Express VI, the configuration dialog box options, and the inputs and outputs of the Express VI. Each Express VI has a corresponding help topic you can access by clicking the Help button in the configuration dialog box or by right-clicking the Express VI and selecting Help from the shortcut menu.
1-12
ni.com
Chapter 1
6. 7. 8.
In the Formula topic, find the dialog box option whose description indicates that it enters a variable into the formula. Minimize the LabVIEW Help to return to the Configure Formula dialog box. Change the text in the Label column of the dialog box option you read about, shown at left, from X1 to Sawtooth to indicate the input value to the Formula Express VI. When you click in the Formula text box at the top of the Configure Formula dialog box, the text changes to match the label you entered. Define the value of the scaling factor by entering *10 after Sawtooth in the Formula text box. You can use the Input buttons in the configuration dialog box or you can use the *, 1, and 0 keyboard buttons to enter the scaling factor. If you use the Input buttons in the configuration dialog box, LabVIEW places the formula input after the Sawtooth input in the Formula text box. If you use the keyboard, click in the Formula text box after Sawtooth and enter the formula you want to appear in the text box. The Configure Formula dialog box should appear similar to Figure 1-7.
9.
1-13
Chapter 1
Note If you enter an invalid formula in the Formula text box, the Errors LED in the upper right corner turns from green to gray and displays the text Invalid Formula.
10. Click the OK button to save the current configuration and close the Configure Formula dialog box. 11. Move the cursor over the arrow on the Sawtooth output of the Simulate Signal Express VI. 12. When the Wiring tool appears, click the arrow on the Sawtooth output and then click the arrow on the Sawtooth input of the Formula Express VI, shown at left, to wire the two objects together. 13. Use the Wiring tool to wire the Result output of the Formula Express VI to the Waveform Graph terminal. Examine the wires connecting the Express VIs and terminals. The arrows on the Express VIs and terminals indicate the direction that the data flows along these wires. The block diagram should appear similar to Figure 1-8.
You can right-click any wire and select Clean Up Wire from the shortcut menu to have LabVIEW automatically find a route for the wire around existing objects on the block diagram. LabVIEW also routes a wire to decrease the number of bends in the wire. You also can click the Clean Up Diagram button on the block diagram toolbar to have LabVIEW automatically reroute all existing wires and rearrange objects on the block diagram to generate a cleaner look.
Tip
14. Press the <Ctrl-S> keys or select FileSave to save the VI.
1-14
ni.com
Chapter 1
Complete the following steps to display two signals on the same graph. 1. 2. On the block diagram, move the cursor over the arrow on the Sawtooth output of the Simulate Signal Express VI. Use the Wiring tool to wire the Sawtooth output to the Waveform Graph terminal. The Merge Signals function, shown at left, appears where the two wires connect. A function is a built-in execution element, comparable to an operator, function, or statement in a text-based programming language. The Merge Signals function takes the two separate signals and combines them so that both can display on the same graph. The block diagram should appear similar to Figure 1-9.
3. 4.
Press the <Ctrl-S> keys or select FileSave to save the VI. Return to the front panel, run the VI, and turn the knob control. The graph plots the original sawtooth wave and the scaled sawtooth wave with 10 times the amplitude, as you specified in the Formula Express VI. The maximum value on the y-axis automatically scales as you turn the knob.
5.
1-15
Chapter 1
2.
In the Label section on the Appearance page, delete the label Knob, and enter Amplitude in the text box. The Knob Properties dialog box should appear similar to Figure 1-10.
3.
Click the Scale tab and in the Scale Style section, place a checkmark in the Show color ramp checkbox. The knob on the front panel updates to reflect these changes. Click the OK button to save the current configuration and close the Knob Properties dialog box. Save the VI. Reopen the Knob Properties dialog box and experiment with other properties of the knob. For example, on the Scale page, try changing the colors for the Marker text color by clicking the color box. Click the Cancel button to avoid applying any changes you made while experimenting. If you want to keep the changes you made, click the OK button.
4. 5. 6.
7.
1-16
ni.com
Chapter 1
3. 4.
Right-click the waveform graph and select Properties from the shortcut menu to display the Graph Properties dialog box. On the Plots page, select Sawtooth from the top pull-down menu. In the Colors section, click the Line color box to display the color picker. Select a new line color. Select Sawtooth (Formula Result) from the top pull-down menu. In the Name text box, delete the current label and change the name of this plot to Scaled Sawtooth.
5. 6.
1-17
Chapter 1
7.
Click the OK button to save the current configuration and close the Graph Properties dialog box. The plot color and plot legend on the front panel change. Reopen the Graph Properties dialog box and experiment with other properties of the graph. For example, on the Scales page, try disabling automatic scaling and changing the minimum and maximum value of the y-axis. Click the Cancel button to avoid applying any changes you made while experimenting. If you want to keep the changes you made, click the OK button.
8.
9.
Summary
The following topics are a summary of the main concepts you learned in this chapter.
Front Panel
The front panel is the user interface of a VI. You build the front panel by using controls and indicators, which are the interactive input and output terminals of the VI, respectively. Controls and indicators are located on the Controls palette. Controls are knobs, push buttons, dials, and other input mechanisms. Controls simulate instrument input mechanisms and supply data to the block diagram of the VI.
1-18
ni.com
Chapter 1
Indicators are graphs, LEDs, and other displays. Indicators simulate instrument output mechanisms and display data the block diagram acquires or generates.
Block Diagram
The block diagram contains the graphical source code, also known as G code or block diagram code, for how the VI runs. The block diagram code uses graphical representations of functions to control the front panel objects. Front panel objects appear as icon terminals on the block diagram. Wires connect control and indicator terminals to Express VIs, VIs, and functions. Data flows through the wires from controls to VIs and functions, from VIs and functions to other VIs and functions, and from VIs and functions to indicators. The movement of data through the nodes on the block diagram determines the execution order of the VIs and functions. This movement of data is known as dataflow programming.
Express VIs
Use Express VIs located on the Functions palette for common measurement tasks. When you place an Express VI on the block diagram, the dialog box you use to configure that Express VI appears by default. Set the options in this configuration dialog box to specify how the Express VI behaves. You also can double-click an Express VI or right-click an Express VI and select Properties from the shortcut menu to display the configuration dialog box. If you wire data to an Express VI and run it, the
1-19
Chapter 1
Express VI displays real data in the configuration dialog box. If you close and reopen the Express VI, the VI displays sample data in the configuration dialog box until you run the VI again. Express VIs appear on the block diagram as expandable nodes with icons surrounded by a blue field. You can resize an Express VI to display its inputs and outputs. The inputs and outputs you can display for the Express VI depend on how you configure the VI.
1-20
ni.com
Chapter 1
Shortcuts
This chapter introduced the following keyboard shortcuts.
Note The <Ctrl> key in shortcuts corresponds to the (Mac OS) <Option> or <Command> key or (Linux) <Alt> key.
Function
Undoes the last action. Switches between the block diagram and the front panel window. Saves a VI.
1-21
Customizing a VI
You can choose one of many LabVIEW template VIs to use as a starting point when building VIs. However, sometimes you need to build a VI for which a template is not available. This chapter teaches you how to build and customize a VI without using a template.
2-1
Chapter 2
Customizing a VI
Opening a Blank VI
If no template is available for the VI you want to build, you can start with a blank VI and add Express VIs to accomplish a specific task. Complete the following steps to open a blank VI. 1. In the Getting Started window, click the Blank VI link in the New section or press the <Ctrl-N> keys to open a blank VI. A blank front panel window and block diagram window appear.
Note
You also can open a blank VI by selecting FileNew VI or by selecting FileNew and selecting Blank VI from the Create New list. 2. 3. Display the block diagram. If the Functions palette is not visible, right-click any blank space on the block diagram to display a temporary version of the Functions palette. Click the thumbtack, shown at left, in the upper left corner of the Functions palette to pin the palette so it is no longer temporary.
Figure 2-2. Context Help Window Tip You also can press the <Ctrl-H> keys to display the Context Help window. (Mac OS) Press the <Command-Shift-H> keys.
2-2
ni.com
Chapter 2
Customizing a VI
2.
On the Functions palette, select the ExpressInput palette and move the cursor over one of the Express VIs on the Input palette. When you move the cursor over a VI, the Context Help window displays information about that VI.
3.
Use the information that appears in the Context Help window to find the Express VI that can simulate a sine wave signal. Keep the Context Help window open. The context help provides useful information as you complete the rest of this exercise.
4.
Select the Express VI that can simulate a sine wave signal and place it on the block diagram. The Configure Simulate Signal dialog box appears. Move the cursor over the various options in the Configure Simulate Signal dialog box, such as Frequency (Hz) and Amplitude. Read the information that appears in the Context Help window. Configure the Simulate Signal Express VI to generate a sine wave with a frequency of 10.7 and amplitude of 2. The signal in the Result Preview window changes to reflect the configured sine wave.
5.
6.
7. 8.
Click the OK button to save the current configuration and close the Configure Simulate Signal dialog box. Move the cursor over the Simulate Signal Express VI and read the information that appears in the Context Help window. The Context Help window displays information about how you configured the Simulate Signal Express VI in addition to the standard context help description.
9.
2-3
Chapter 2
Customizing a VI
2.
Click the Search tab, enter sample compression in the Type in the word(s) to search for text box, and press the <Enter> key. You can place quotation marks around the phrase to search for the exact phrase. For example, you can enter "sample compression" to narrow the search results. This word choice reflects what you want this Express VI to docompress, or reduce, the number of samples in a signal. You also can click the Index tab to search keywords and concepts.
3. 4. 5. 6.
Double-click the Sample Compression topic in the search results to display the topic that describes the Sample Compression Express VI. After you read the description of the Express VI, click the Add to the block diagram button to place the Express VI on the cursor. Move the cursor to the block diagram. Add the Sample Compression Express VI to the block diagram to the right of the Simulate Signal Express VI.
Tip
When you know which item you want to add to the block diagram or front panel, you can use the Quick Drop dialog box to quickly find the item and add it to the block diagram or front panel. Select Quick Drop from the View menu to display this dialog box. You also can press the <Ctrl-Space> keys. (Mac OS) Press the <Command-Shift-Space> keys. 7. 8. 9. Configure the Sample Compression Express VI to reduce the signal by a factor of 25 using the mean of these values. Click the OK button to save the current configuration and close the Configure Sample Compression dialog box. Use the Wiring tool to wire the Sine output of the Simulate Signal Express VI to the Signals input of the Sample Compression Express VI.
2-4
ni.com
Chapter 2
Customizing a VI
2.
Right-click the Mean output of the Sample Compression Express VI and select Insert Input/Output from the shortcut menu to insert the Enable input. In previous exercises, you learned to add inputs and outputs by expanding the Express VI using the down arrows. Using the shortcut menu is a different way to display and select the inputs and outputs of an Express VI.
3.
Right-click the Enable input and select CreateControl from the shortcut menu to create a switch. A Boolean control, shown at left, appears on the block diagram. Control terminals have a thicker border than indicator terminals. Also, an arrow appears on the right of the terminal if the terminal is a control, and an arrow appears on the left of the terminal if the terminal is an indicator.
4.
Right-click the wire that connects the Sine output of the Simulate Signal Express VI to the Signals input of the Sample Compression Express VI and select CreateGraph Indicator from the shortcut menu. Use the Wiring tool to wire the Mean output of the Sample Compression Express VI to the Sine graph indicator. The Merge Signals function appears. Arrange the objects on the block diagram so they appear similar to Figure 2-3.
5.
6.
7.
Display the front panel. The controls and indicators you added appear on the front panel with labels that correspond to the inputs and outputs from which you created the controls and indicators.
2-5
Chapter 2
Customizing a VI
Note
You might need to scroll or resize the front panel to see all controls and indicators. 8. Save the VI.
5.
2-6
ni.com
Chapter 2
Customizing a VI
6.
Move the cursor to the upper left corner of the block diagram. Click and drag the cursor diagonally to enclose all the Express VIs and wires, as shown in Figure 2-4.
Figure 2-4. Placing the While Loop around the Express VIs
7.
Release the mouse to place the While Loop around the Express VIs and wires. The While Loop, shown at left, appears with a STOP button wired to the conditional terminal. This While Loop is configured to stop when the user clicks the STOP button.
8.
Display the front panel and run the VI. The VI now runs until you click the STOP button. A While Loop executes the VIs and functions inside the loop until the user clicks the STOP button.
9.
2-7
Chapter 2
Customizing a VI
3.
Display the block diagram. A wire appears as a dashed black line with a red X in the middle, shown at left. The dashed black line is a broken wire. The Run button, shown at left, appears broken to indicate the VI cannot run.
4.
Click the broken Run button to display the Error list window. The Error list window lists all errors in the VI and provides details about each error. You can use the Error list window to locate errors.
5.
In the errors and warnings list, select the Wire: has loose ends error and click the Help button to display more information about the error.
You also can move the Wiring tool over a broken wire to display a tip strip that describes why the wire is broken. This information also appears in the Context Help window when you move the Wiring tool over a broken wire.
Tip
6. 7.
In the errors and warnings list, double-click the Wire: has loose ends error to highlight the broken wire. Press the <Ctrl-B> keys to delete the broken wire. Pressing the <Ctrl-B> keys deletes all broken wires on the block diagram. You can press the <Delete> key to delete only the selected wire.
8.
Select ViewError List to display the Error list window. No errors appear in the errors and warnings field.
Tip
You also can press the <Ctrl-L> keys to display the Error list window. 9. Click the Close button to close the Error list window. The Run button no longer appears broken.
2-8
ni.com
Chapter 2
Customizing a VI
3. 4. 5.
Click the OK button to save the current configuration and close the Configure Time Delay dialog box. Display the front panel and run the VI. Click the Enable switch and examine the change on the graph. If the Enable switch is on, the graph displays the reduced signal. If the Enable switch is off, the graph does not display the reduced signal.
6.
2.
2-9
Chapter 2
Customizing a VI
6. 7. 8.
Display the front panel and arrange the controls and indicators as shown in Figure 2-1. Run the VI. Click the Enable switch. If the Enable switch is on, the table displays the mean values of every 25 samples of the sine wave. If the Enable switch is off, the table does not record the mean values.
9.
10. Experiment with properties of the table by using the Table Properties dialog box. For example, try changing the number of columns to one. 11. Save and close the VI.
2-10
ni.com
Chapter 2
Customizing a VI
Refer to the Using Help book on the Contents tab in the LabVIEW Help for more information about searching help. (Windows) Before you search, you can narrow the search results by placing a checkmark in the Search titles only checkbox near the bottom of the help window. You also can use operators such as AND, OR, and NEAR in the Type in the word(s) to search for text box to narrow the search results.
Tip
3.
(Windows) Click the Location column header to sort the search results by content type. Reference topics contain reference information about LabVIEW objects such as VIs, functions, palettes, menus, and tools. How-To topics contain step-by-step instructions for using LabVIEW. Concept topics contain information about LabVIEW programming concepts.
4. 5.
Double-click the Time Delay Express VI search result to display the reference topic that describes the Time Delay Express VI. After you read the description of the Express VI, click the Open example button in the Example section near the bottom of the topic to open an example that uses the Time Delay Express VI. Run the VI and move the vertical pointer slides. The amplitudes of Value A and B change as you move the vertical pointer slides. Stop the VI. Select WindowShow Block Diagram and read the block diagram comments. Close the example VI and open the LabVIEW Help window.
6. 7. 8. 9.
10. Click the Browse related examples button to open the NI Example Finder and display a list of examples similar to the example that uses this VI. The NI Example Finder searches among hundreds of examples, including all installed examples and the examples located on the NI Developer Zone at ni.com/zone. You can modify an example to fit an application, or you can copy and paste from one or more examples into a VI that you create. You also can right-click a VI or function on the block diagram or on a pinned palette and select Examples from the shortcut menu to display a help topic with links to examples for that VI or function. To launch the NI Example Finder and browse or search examples, select HelpFind Examples or click the Find Examples link in the Examples section of the Getting Started window.
Note
There is not an example for all VIs. 11. After you experiment with the NI Example Finder and the example VIs, close the NI Example Finder.
2-11
Chapter 2
Customizing a VI
Summary
The following topics are a summary of the main concepts you learned in this chapter.
2-12
ni.com
Chapter 2
Customizing a VI
2-13
Chapter 2
Customizing a VI
Shortcuts
This chapter introduced the following keyboard shortcuts.
Note The <Ctrl> key in these shortcuts corresponds to the (Mac OS) <Option> or <Command> key or (Linux) <Alt> key.
Function Opens a new, blank VI. Shows or hides the Context Help window. (Mac OS) Press the <Command-Shift-H> keys. Displays the Quick Drop dialog box. (Mac OS) Press the <Command-Shift-Space> keys. Deletes all broken wires in a VI. Displays the Error list window.
2-14
ni.com
LabVIEW includes a set of Express VIs that help you analyze signals. This chapter teaches you how to use LabVIEW to perform a basic analysis of a signal and how to save the analyzed data to a file.
Note The exercises in this chapter use Express VIs that are available only in the LabVIEW Full and Professional Development Systems.
3-1
Chapter 3
Building an Analysis VI
In the following exercises, you will build a VI that generates a signal, filters the signal, indicates if the signal exceeds a certain limit, and records the data. After you complete the exercises, the front panel of the VI will look similar to the front panel in Figure 3-1.
You can complete the exercises in this chapter in approximately 40 minutes.
3-2
ni.com
Chapter 3
3. 4. 5. 6.
Click the OK button or double-click the name of the template to create a VI from the template. If the Context Help window is not visible, press the <Ctrl-H> keys to display the window. (Mac OS) Press the <Command-Shift-H> keys. Display the block diagram by pressing the <Ctrl-E> keys. Move the cursor over the Amplitude and Level Measurements Express VI, shown at left. The Context Help window displays information about the behavior of the Express VI. Keep the Context Help window open. It will provide useful information as you complete the rest of this exercise.
7.
On the front panel, remove the RMS indicator, shown at left, along with any broken wires on the block diagram that result from removing the indicator. To remove all broken wires from the block diagram, you can press the <Ctrl-B> keys. You will not use the RMS functionality of the Amplitude and Level Measurements Express VI for this exercise. However, you can use the Generate, Analyze, and Display template VI with the RMS functionality in a future project to reduce development time.
8.
On the front panel, right-click the waveform graph indicator and select Properties from the shortcut menu. The Graph Properties dialog box appears. On the Appearance page, place a checkmark in the Visible checkbox in the Label section and enter Unfiltered Signal in the text box.
9.
10. Click the OK button to save the configuration and close the Graph Properties dialog box. 11. Run the VI. The signal appears in the graph. 12. Click the STOP button to stop the VI.
3-3
Chapter 3
Adding a Signal
The Simulate Signal Express VI simulates a sine wave by default. You can customize the simulated signal by changing the options in the Configure Simulate Signal dialog box. Complete the following steps to create an additional simulated signal that adds uniform white noise to the sine wave. 1. On the block diagram, use the Positioning tool to select the Simulate Signal Express VI. Hold down the <Ctrl> key and drag to create an additional Simulate Signal Express VI on the block diagram. (Mac OS) Hold down the <Option> key and drag. (Linux) You also can hold down the middle mouse button and drag. 2. Release the mouse button to place the copied Simulate Signal Express VI below the original Simulate Signal Express VI. LabVIEW updates the name of the copied Simulate Signal Express VI to Simulate Signal2. Double-click the Simulate Signal2 Express VI to display the Configure Simulate Signal dialog box. Select Sine from the Signal type pull-down menu. Enter 60 in the Frequency (Hz) text box. Enter .1 in the Amplitude text box. Place a checkmark in the Add noise checkbox to add noise to the sine signal. Select Uniform White Noise from the Noise type pull-down menu. Enter 0.1 in the Noise amplitude text box.
3. 4. 5. 6. 7. 8. 9.
10. Enter -1 in the Seed number text box. 11. In the Timing section, select the Run as fast as possible option. 12. In the Signal Name section, remove the checkmark from the Use signal type name checkbox. 13. Enter 60 Hz and Noise in the Signal name text box. When you change the signal name in the Configure Simulate Signal dialog box, LabVIEW changes the name of the signal output on the block diagram. Changing the signal name makes it easier for you to identify the signal type when you view the Express VI on the block diagram.
3-4
ni.com
Chapter 3
The Result Preview section displays a random signal. The Configure Simulate Signal dialog box should appear similar to Figure 3-2.
14. Click the OK button to save the current configuration and close the Configure Simulate Signal dialog box.
3-5
Chapter 3
Complete the following steps to add the 60 Hz and Noise signal to the Sine signal. 1. On the block diagram, triple-click the wire that connects the Sine output of the Simulate Signal Express VI to the Signals input of the Amplitude and Level Measurements Express VI and to the Unfiltered Signal indicator and remove the wire. Click the Search button on the Functions palette to search for the Formula Express VI, shown at left, and place it on the block diagram between the Simulate Signal Express VIs and the Amplitude and Level Measurements Express VI. The Configure Formula dialog box appears.
2.
Note
LabVIEW displays a folder glyph to the left of subpalettes in the search results and displays a light blue glyph to the left of Express VIs in the search results. 3. In the Label column, change the label for X1 to Sine and the label for X2 to 60 Hz and Noise. The Formula Express VI automatically enters the first input, Sine, in the Formula text box. 4. 5. 6. 7. 8. Click the + button and then the X2 button to add Sine and 60 Hz and Noise together in the Formula text box. Click the OK button to save the current configuration and close the Configure Formula dialog box. Use the Wiring tool to wire the Sine output of the Simulate Signal Express VI to the Sine input of the Formula Express VI. Wire the 60 Hz and Noise output of the Simulate Signal2 Express VI to the 60 Hz and Noise input of the Formula Express VI. Wire the Result output of the Formula Express VI to the Unfiltered Signal indicator and to the Signals input of the Amplitude and Level Measurements Express VI. Display the front panel by pressing the <Ctrl-E> keys. The signal with added noise appears in the graph. 11. Click the STOP button to stop the VI. 12. Select FileSave As and save the VI as Analysis.vi in an easily accessible location.
9.
3-6
ni.com
Chapter 3
Filtering a Signal
You can use the Filter Express VI to process signals through filters and windows. Complete the following steps to configure the Filter Express VI to filter the signal using an infinite impulse response (IIR) filter. 1. On the block diagram, remove the wire that connects the Result output of the Formula Express VI to the Signals input of the Amplitude and Level Measurements Express VI. Remove all broken wires that result from removing the wire. Search for the Filter Express VI, shown at left, and place it on the block diagram between the Simulate Signal2 Express VI and the Amplitude and Level Measurements Express VI. The Configure Filter dialog box appears. In the Filter Specifications section, change the Cutoff Frequency (Hz) to 25. Click the OK button to save the configuration and close the Configure Filter dialog box. Display the front panel. Click the Unfiltered Signal waveform graph indicator on the front panel and press the <Ctrl> key while you drag to create an additional waveform graph indicator. Place the additional waveform graph indicator below the Unfiltered Signal waveform graph. Triple-click the Unfiltered Signal 2 label above the new waveform graph indicator and enter Filtered Signal to change the label of the indicator. You also can change the label on the Appearance page of the Graph Properties dialog box.
2. 3.
4. 5. 6. 7.
8. 9.
10. On the block diagram, wire the Result output of the Formula Express VI to the Signal input of the Filter Express VI. 11. Wire the Filtered Signal output of the Filter Express VI to the Signals input of the Amplitude and Level Measurements Express VI and to the input of the Filtered Signal waveform graph indicator.
3-7
Chapter 3
12. Select FileSave. The block diagram of the Analysis VI should appear similar to Figure 3-3.
2. 3. 4. 5. 6. 7. 8. 9.
10. Enter -2.5 in the Minimum text box and 2.5 in the Maximum text box.
3-8
ni.com
Chapter 3
11. Click the OK button to save the configuration and close the Graph Properties dialog box. 12. Repeat steps 111 to configure the Filtered Signal graph indicator. The x-axis and the y-axis on the Unfiltered Signal and Filtered Signal graph indicators change to reflect the new configuration.
2. 3.
4.
3-9
Chapter 3
4. 5.
Display the front panel and run the VI. The loop iterates once every tenth of a second. Stop the VI.
3. 4.
Select the round LED indicator and place it on the front panel to the left of the waveform graphs. Double-click the Boolean label above the LED and enter Warning to change the label of the LED. You will use this LED in a later exercise to indicate when a value has exceeded its limit.
5. 6.
Select FileSave As to display the Save As dialog box. Read the various dialog box options. Select the Copy and Substitute copy for original options to create a copy of the original VI and immediately edit the copy. Click the Continue button and save the VI as Warning Light.vi in an easily accessible location.
7.
3-10
ni.com
Chapter 3
2. 3.
4.
6. 7.
3-11
Chapter 3
2.
Wire the Result output of the Greater Express VI to the Warning terminal. The block diagram should appear similar to Figure 3-5.
Note
Red coercion dots appear automatically at the Peak to Peak and Warning input terminals to alert you that you wired two different data types together and LabVIEW converted the value passed into the node to a different representation. The block diagram places the coercion dots on the border of the terminal where the conversion takes place. For this exercise, the conversion does not affect how your VI runs. Refer to the LabVIEW Help for more information about coercion dots. 3. Display the front panel. A numeric indicator labeled Peak to Peak appears on the front panel. This indicator displays the peak-to-peak value of the signal.
3-12
ni.com
Chapter 3
4.
Run the VI. When the peak-to-peak value exceeds 2.0, the Warning indicator lights.
5. 6.
Click the STOP button to stop the VI. Save the VI.
3. 4.
3-13
Chapter 3
2. 3. 4. 5.
2. 3. 4.
3-14
ni.com
Chapter 3
2. 3. 4.
5.
3-15
Chapter 3
3-16
ni.com
Chapter 3
Summary
The following topics are a summary of the main concepts you learned in this chapter.
Filtering Data
The Filter Express VI processes signals through filters and windows. You can use the Filter Express VI to remove noise from a signal.
Saving Data
The Write To Measurement File Express VI saves data that a VI generates and analyzes to a .lvm, .tdm, or .tdms measurement file. The text-based measurement file (.lvm) is a tab-delimited text file you can open with a spreadsheet application or a text-editing application. LabVIEW saves data with up to six digits of precision in a .lvm file. In addition to the data an Express VI generates, the .lvm file includes headers that contain information about the data, such as the date and time LabVIEW generated the data. The binary measurement file (.tdm) is a binary file that contains waveform data. Binary .tdm files provide higher accuracy for floating-point numbers, take up less space on disk, and perform faster than text-based measurement files (.lvm). The TDM Streaming file (.tdms) is a binary file that provides faster writing performance than the .tdm file format and allows a simpler interface for defining properties. LabVIEW installs the LabVIEW Data directory in the default file directory of the operating system to help you organize and locate the data files LabVIEW generates. Refer to the LabVIEW Help for more information about writing data to and reading data from .lvm and .tdm files.
3-17
LabVIEW has the capability to connect and interact with a large number of hardware devices. This chapter introduces you to two Express VIs that make acquiring data and communicating with traditional, third-party instruments easier. In the first exercise, you use the DAQ Assistant Express VI to acquire data with a DAQ device. This exercise requires data acquisition hardware and that you have NI-DAQmx installed. Refer to the NI-DAQ Readme for more information about platforms supported by NI-DAQmx software. Refer to the Taking Measurements book on the Contents tab in the LabVIEW Help for information about acquiring data and communicating with instruments on all platforms. In the second exercise, you use the Instrument I/O Assistant Express VI to communicate with a traditional, third-party instrument. This exercise requires an instrument and that you have the Instrument I/O Assistant installed. Refer to the Controlling Instruments book on the Contents tab in the LabVIEW Help for more information about communicating with instruments.
Note
LabVIEW supports the DAQ and Instrument I/O Assistants used in this chapter on Windows only.
4-1
Chapter 4
Acquiring a Signal
In the following exercises, you will use the DAQ Assistant Express VI to create a task in NI-DAQmx. NI-DAQmx is a programming interface you can use to communicate with data acquisition devices. Refer to the Getting Started with LabVIEWGetting Started with DAQTaking an NI-DAQmx Measurement in LabVIEW book on the Contents tab in the LabVIEW Help for information about additional methods you can use to create NI-DAQmx tasks. The following exercises require that you have NI-DAQmx and an NI-DAQmx-supported device installed. Refer to the NI-DAQ Readme for the list of NI-DAQmx-supported devices. If you have a device that is supported only with Traditional NI-DAQ, refer to the Taking Measurements book on the Contents tab in the LabVIEW Help for information about using Traditional NI-DAQ (Legacy) for data acquisition.
Note
With NI-DAQmx 7.4 or later you can create NI-DAQmx simulated devices in MAX. An NI-DAQmx simulated device is a software replica of a DAQ device. Refer to the Measurement & Automation Explorer Help for NI-DAQmx for detailed instructions on creating an NI-DAQmx simulated device that you can use to complete the following exercises. In the following exercises, you will create an NI-DAQmx task that continuously takes a voltage reading and plots the data on a waveform graph.
4-2
ni.com
Chapter 4
3.
Select the DAQ Assistant Express VI, shown at left, on the Input palette and place it on the block diagram. The DAQ Assistant launches and the Create New Express Task dialog box appears. Click Acquire SignalsAnalog Input to display the Analog Input options. Select Voltage to create a new voltage analog input task. The dialog box displays a list of channels on each installed DAQ device. The number of channels listed depends on the number of channels you have on the DAQ device.
4. 5.
6.
In the Supported Physical Channels list, select the physical channel to which the device connects the signal, such as ai0, and then click the Finish button. The DAQ Assistant opens a new dialog box, shown in Figure 4-1, that displays options for configuring the channel you selected to complete a task.
4-3
Chapter 4
7. 8.
In the Signal Input Range section of the Settings page, enter 10 for the Max value and enter -10 for the Min value. In the Timing Settings section of the Configuration page, select N Samples from the Acquisition Mode pull-down menu.
4-4
ni.com
Chapter 4
9.
10. Click the OK button to save the current configuration and close the DAQ Assistant. LabVIEW builds the VI. 11. Save the VI as Read Voltage.vi in an easily accessible location.
3. 4.
On the block diagram, right-click the DAQ Assistant Express VI and select Properties from the shortcut menu to open the DAQ Assistant. Right-click Voltage in the list of channels and select Rename from the shortcut menu to display the Rename a channel or channels dialog box.
Tip
You also can select the name of the channel and press the <F2> key to display the Rename a channel or channels dialog box. 5. 6. 7. In the New Name text box, enter First Voltage Reading, and click the OK button. In the DAQ Assistant dialog box, click the OK button to save the current configuration and close the DAQ Assistant. Display the front panel and run the VI.
First Voltage Reading appears in the waveform graph plot
4-5
Chapter 4
7.
If an error occurs or you click the stop button while the VI is running, the DAQ Assistant Express VI stops reading data and the stopped output returns a TRUE value and stops the While Loop.
4-6
ni.com
Chapter 4
4. 5. 6.
instruments.
4-7
Chapter 4
Note
The Instrument Driver Finder is available only on Windows and Linux. You must have Internet access to use the Instrument Driver Finder. You also can visit the NI Instrument Driver Network at ni.com/idnet to find a driver for an instrument. Complete the following steps to search for and install an instrument driver using the Instrument Driver Finder. 1. Select ToolsInstrumentationFind Instrument Drivers or HelpFind Instrument Drivers to launch the Instrument Driver Finder. Select National Instruments from the Manufacturer pull-down menu. Click the Search button. The folders on the Search Results page represent instrument drivers, and the contents of the folders represent the files that the Instrument Driver Finder can download and install. The Instrument Driver Finder opens the first driver folder in the list and selects a driver file. You can click different files and use the detailed information to the right to choose the correct driver for the instrument. Select the first instrument driver file from the Driver list and click the Install button. If you do not have an NI.com profile, select No, I need to create a profile and click the Create Profile button to open a browser window in which you can create an NI.com profile. If you do have an NI.com profile, skip to step 7. Create a profile and return to the Instrument Driver Finder. Select Yes, fill in your email address and ni.com password, and click the Login button. Click the Close button after the Instrument Driver Finder downloads and installs the instrument driver into the labview\instr.lib directory and displays the path to the newly installed driver. Click the Close button to close the Instrument Driver Finder.
2. 3.
4. 5.
6. 7. 8.
9.
You also can create your own instrument drivers. Refer to the Controlling InstrumentsUsing Instrument Drivers book on the Contents tab in the LabVIEW Help for more information about creating instrument drivers.
4-8
ni.com
Chapter 4
You must have the Instrument I/O Assistant installed to use the Instrument I/O Assistant Express VI. You install the Instrument I/O Assistant from the National Instruments Device Drivers CD. Complete the following steps to use the Instrument I/O Assistant Express VI to select an instrument. 1. 2. 3. Turn on the instrument you want to use. The instrument must be powered on to use the Instrument I/O Assistant Express VI. Open a new VI. Select the Instrument I/O Assistant Express VI on the Input palette and place it on the block diagram. The Instrument I/O Assistant dialog box appears. If the help is not visible to the right of the dialog box, click the Show Help button, shown at left, in the upper right corner of the Instrument I/O Assistant dialog box. The help appears to the right of the dialog box. The top help window contains how-to information about using the Instrument I/O Assistant. The bottom help window provides context-sensitive help about components in the dialog box. 5. Click the Select Instrument link in the top help window and follow the instructions in the help window to select the instrument with which you want to communicate. If necessary, configure the properties of the instrument. If you want to minimize the help window, click the Hide Help button, shown at left, in the upper right corner of the Instrument I/O Assistant dialog box.
4.
6. 7.
4-9
Chapter 4
Complete the following steps to communicate with the instrument. 1. 2. In the Instrument I/O Assistant dialog box, click the Add Step button and click the Query and Parse step. Enter *IDN? in the Enter a command text box.
*IDN? is a query that most instruments recognize. The response is an
identification number string that describes the instrument. If the instrument does not accept this command, refer to the reference manual for the instrument for a list of commands the instrument does accept. 3. Click the Run this step button shown at left. The Instrument I/O Assistant sends the command to the instrument, and the instrument returns its identification information. 4. Select ASCII only from the pull-down menu below the Byte index column of the response window to parse the instrument name as an ASCII string. You also can use the Instrument I/O Assistant to parse ASCII numbers and binary data. Click the Parsing help button, shown at left, in the Instrument I/O Assistant dialog box to display information about parsing data. In the ASCII representation column of the response window, click the value you want to parse. Enter a name for the token, or parsed data selection, in the Token name text box. The name that you entered in the Token name text box is the output of the Instrument I/O Assistant Express VI, shown at left.
5. 6. 7.
4-10
ni.com
Chapter 4
5. 6.
Enter a name for the parameter in the Parameter name text box. You use this name to reference the parameter in the application. Click the OK button to save the current configuration and close the Instrument I/O Assistant dialog box.
Summary
The following topics are a summary of the main concepts you learned in this chapter.
Tasks
In NI-DAQmx, a task is a collection of one or more virtual channels with timing, triggering, and other properties. Conceptually, a task represents a measurement or generation you want to perform. For example, you can configure a collection of channels for analog input operations. After you create a task, you can access the single task instead of configuring the channels individually to perform analog input operations. After you create a task, you can add or remove channels from that task. Refer to the Taking Measurements book on the Contents tab in the LabVIEW Help for more information about channels and tasks.
4-11
Chapter 4
Instrument Drivers
Use the NI Instrument Driver Finder to search for and install LabVIEW Plug and Play instrument drivers without leaving the LabVIEW development environment. An instrument driver is a set of software routines that control a programmable instrument. Each routine corresponds to a programmatic operation such as configuring, reading from, writing to, and triggering the instrument. Use an instrument driver for instrument control when possible. National Instruments provides thousands of instrument drivers for a wide variety of instruments. Refer to the Controlling InstrumentsUsing Instrument Drivers book on the Contents tab in the LabVIEW Help for more information about the Instrument Driver Finder. You also can visit the NI Instrument Driver Network at ni.com/idnet to find a driver for an instrument, or you can create your own instrument drivers. Refer to the Controlling InstrumentsUsing Instrument Drivers book on the Contents tab in the LabVIEW Help for more information about creating instrument drivers.
4-12
ni.com
The previous chapters in this manual introduce you to most of the LabVIEW features you need to build common measurement applications. As you familiarize yourself with the LabVIEW environment, you might find that you need to enhance VIs or that you need more fine-tuned control of the processes the VIs perform. This chapter introduces you to some of the concepts you should be familiar with as you start using other LabVIEW features. Refer to the Fundamentals book on the Contents tab in the LabVIEW Help for more information about these concepts. The Concepts books contain information about LabVIEW programming concepts, and the How-To books contain step-by-step instructions for using LabVIEW.
5-1
Chapter 5
VIs
You can use an existing VI or a VI you create as a subVI. When you place a VI on the block diagram, the VI is a subVI. When you double-click a subVI, its front panel appears, rather than a dialog box in which you can configure options. The icon for a VI appears in the upper right corner of the front panel and block diagram. This icon is the same as the icon that appears when you place the VI on the block diagram. You can use the default icon or create a custom icon using the Icon Editor. Refer to the FundamentalsCreating VIs and SubVIs book on the Contents tab in the LabVIEW Help for more information about creating VIs, configuring them as subVIs, and creating icons. You also can save the configuration of an Express VI as a subVI. Refer to the FundamentalsBuilding the Block Diagram book on the Contents tab in the LabVIEW Help for more information about creating subVIs from Express VIs.
5-2
ni.com
Chapter 5
Functions
Functions are the fundamental operating elements of LabVIEW. Unlike VIs, functions do not have front panels or block diagrams. Functions provide the basic building blocks for programming a VI, interfacing with hardware and software, and performing other essential tasks in LabVIEW. Refer to the FundamentalsBuilding the Block Diagram book on the Contents tab in the LabVIEW Help for more information about functions.
Data Types
On the block diagram of a VI, the terminals for the front panel objects are different colors. The color and symbol of a terminal indicate the data type of the corresponding control or indicator. Colors also indicate the data types of wires, inputs, and outputs. The color of inputs and outputs of Express VIs indicate what type of data the input or output accepts or returns. Data types indicate which objects, inputs, and outputs you can wire together. For example, a switch has a green border, so you can wire a switch to any Express VI input with a green label. A knob has an orange border, so you can wire a knob to any Express VI input with an orange label. However, you cannot wire a knob to an input with a green label. The wires you create are the same color as the terminal. Express VIs generate and acquire data using the dynamic data type. The dynamic data type appears as a dark blue terminal, shown at left. Most Express VIs accept or return dynamic data. You can wire dynamic data to any indicator or input that accepts numeric, waveform, or Boolean data. Wire dynamic data to an indicator that can best present the data. Such indicators include graphs, charts, and numeric indicators. Most other VIs and functions in LabVIEW do not accept dynamic data. To use a built-in VI or function to analyze or process dynamic data, you must convert the dynamic data to numeric, Boolean, waveform, or array data. Use the Convert from Dynamic Data Express VI to convert dynamic data to numeric, Boolean, waveform, and array data for use with other VIs and functions. When you wire dynamic data to an array indicator, LabVIEW inserts the Convert from Dynamic Data Express VI on the block diagram. Use the Convert to Dynamic Data Express VI to convert numeric, Boolean, waveform, and array data to dynamic data for use with Express VIs. Refer to the FundamentalsBuilding the Block Diagram book on the Contents tab in the LabVIEW Help for more information about data types.
5-3
Chapter 5
5-4
ni.com
Chapter 5
Customize menusYou can configure which menu items appear when a user runs a VI. You also can create custom menus. Refer to the FundamentalsCreating VIs and SubVIs book on the Contents tab in the LabVIEW Help for more information about these features. Use LabVIEW projectsYou can use projects to group together LabVIEW files and files not specific to LabVIEW, create build specifications, and deploy or download files to multiple targets from one location. You must use a project to build applications and shared libraries. You also must use a project to work with an RT, FPGA, PDA, Touch Panel, DSP, or embedded target. Refer to the specific module documentation for more information about using projects with these targets. Refer to the FundamentalsWorking with Projects and Targets book on the Contents tab in the LabVIEW Help for more information about using LabVIEW projects. Access other Windows applicationsYou can use LabVIEW as a .NET or ActiveX client to access the objects, properties, methods, and events associated with .NET server or ActiveX applications. Refer to the FundamentalsWindows Connectivity book on the Contents tab in the LabVIEW Help for more information about these features. Write mathematical formulas, equations, and scriptsYou can use various nodes to perform mathematical operations on the block diagram. You also can use the LabVIEW MathScript text-based language to write mathematical functions and scripts. Refer to the FundamentalsFormulas and Equations book on the Contents tab in the LabVIEW Help for more information about these features.
5-5
Visit the following sections of the award-winning National Instruments Web site at ni.com for technical support and professional services: SupportTechnical support at ni.com/support includes the following resources: Self-Help Technical ResourcesFor answers and solutions, visit ni.com/support for software drivers and updates, a searchable KnowledgeBase, product manuals, step-by-step troubleshooting wizards, thousands of example programs, tutorials, application notes, instrument drivers, and so on. Registered users also receive access to the NI Discussion Forums at ni.com/forums. NI Applications Engineers make sure every question submitted online receives an answer. Standard Service Program MembershipThis program entitles members to direct access to NI Applications Engineers via phone and email for one-to-one technical support as well as exclusive access to on demand training modules via the Services Resource Center. NI offers complementary membership for a full year after purchase, after which you may renew to continue your benefits. For information about other technical support options in your area, visit ni.com/services, or contact your local office at ni.com/contact. Training and CertificationVisit ni.com/training for self-paced training, eLearning virtual classrooms, interactive CDs, and Certification program information. You also can register for instructor-led, hands-on courses at locations around the world. System IntegrationIf you have time constraints, limited in-house technical resources, or other project challenges, National Instruments Alliance Partner members can help. To learn more, call your local NI office or visit ni.com/alliance.
A-1
Appendix A
If you searched ni.com and could not find the answers you need, contact your local office or NI corporate headquarters. Phone numbers for our worldwide offices are listed at the front of this manual. You also can visit the Worldwide Offices section of ni.com/niglobal to access the branch office Web sites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.
A-2
ni.com
Glossary
A
automatic scaling Ability of scales to adjust to the range of plotted values. On graph scales, autoscaling determines maximum and minimum scale values.
B
block diagram Pictorial description or representation of a program or algorithm. The block diagram consists of executable icons called nodes and wires that carry data between the nodes. The block diagram is the source code for the VI. The block diagram resides in the block diagram window of the VI. Front panel objects to manipulate and display Boolean (TRUE or FALSE) data. Button that replaces the Run button when a VI cannot run because of errors. VI that cannot run because of errors; signified by a broken arrow in the broken Run button.
G-1
Glossary
C
channel 1. PhysicalA terminal or pin at which you can measure or generate an analog or digital signal. A single physical channel can include more than one terminal, as in the case of a differential analog input channel or a digital port of eight lines. A counter also can be a physical channel, although the counter name is not the name of the terminal where the counter measures or generates the digital signal. 2. VirtualA collection of property settings that can include a name, a physical channel, input terminal connections, the type of measurement or generation, and scaling information. You can define NI-DAQmx virtual channels outside a task (global) or inside a task (local). Configuring virtual channels is optional in Traditional NI-DAQ (Legacy) and earlier versions, but is integral to every measurement you take in NI-DAQmx. In Traditional NI-DAQ (Legacy), you configure virtual channels in MAX. In NI-DAQmx, you can configure virtual channels either in MAX or in your program, and you can configure channels as part of a task or separately. 3. SwitchA switch channel represents any connection point on a switch. It can be made up of one or more signal wires (commonly one, two, or four), depending on the switch topology. A virtual channel cannot be created with a switch channel. Switch channels may be used only in the NI-DAQmx Switch functions and VIs. checkbox Small square box in a dialog box which you can select or clear. Checkboxes generally are associated with multiple options that you can set. You can select more than one checkbox. Terminal of a While Loop that contains a Boolean value that determines if the VI performs another iteration. Window that displays basic information about LabVIEW objects when you move the cursor over each object. Objects with context help information include VIs, functions, constants, structures, palettes, properties, methods, events, and dialog box components. Front panel object for entering data to a VI interactively or to a subVI programmatically, such as a knob, push button, or dial. Palette that contains front panel controls, indicators, and decorative objects. VI whose front panel, block diagram, or Icon Editor is the active window.
G-2
ni.com
Glossary
D
DAQ DAQ Assistant DAQ device See data acquisition (DAQ). A graphical interface for configuring measurement tasks, channels, and scales. A device that acquires or generates data and can contain multiple channels and conversion devices. DAQ devices include plug-in devices, PCMCIA cards, and DAQPad devices, which connect to a computer USB or IEEE 1394 (FireWire) port. SCXI modules are considered DAQ devices. 1. Acquiring and measuring analog or digital electrical signals from sensors, acquisition transducers, and test probes or fixtures. 2. Generating analog or digital electrical signals. data flow Programming system that consists of executable nodes that execute only when they receive all required input data. The nodes produce output data automatically when they execute. LabVIEW is a dataflow system. The movement of data through the nodes determines the execution order of the VIs and functions on the block diagram. Format for information. In LabVIEW, acceptable data types for most VIs and functions are numeric, array, string, Boolean, path, refnum, enumeration, waveform, and cluster. Preset value. Many VI inputs use a default value if you do not specify a value. An instrument or controller you can access as a single entity that controls or monitors real-world I/O points. A device often is connected to a host computer through some type of communication network. See also DAQ device and measurement device. To use the cursor on the screen to select, move, copy, or delete objects. Software that controls a specific hardware device, such as a DAQ device. Data type used by Express VIs that includes the data associated with a signal and attributes that provide information about the signal, such as the name of the signal or the date and time LabVIEW acquired the data. Attributes specify how the signal appears on a graph or chart.
data type
default device
G-3
Glossary
E
Error list window error message Express VI Window that displays errors and warnings occurring in a VI and in some cases recommends how to correct the errors. Indication of a software or hardware malfunction or of an unacceptable data entry attempt. A subVI designed to aid in common measurement tasks. You configure an Express VI using a configuration dialog box.
F
For Loop front panel function Functions palette Iterative loop structure that executes its subdiagram a set number of times. Equivalent to text-based code: For i = 0 to n 1, do.... Interactive user interface of a VI. Front panel appearance imitates physical instruments, such as oscilloscopes and multimeters. Built-in execution element, comparable to an operator, function, or statement in a text-based programming language. Palette that contains VIs, functions, block diagram structures, and constants.
G
General Purpose Interface Bus GPIB. Synonymous with HP-IB. The standard bus used for controlling electronic instruments with a computer. Also called IEEE 488 bus because it is defined by ANSI/IEEE Standards 488-1978, 488.1-1987, and 488.2-1992. 2D display of one or more plots. A graph receives and plots data as a block.
graph
G-4
ni.com
Glossary
I
I/O Input/Output. The transfer of data to or from a computer system involving communications channels, operator input devices, and/or data acquisition and control interfaces. Graphical representation of a node on a block diagram. Front panel object that displays output, such as a graph or LED. A set of high-level functions that control and communicate with instrument hardware in a system. Add-on launched from the Instrument I/O Assistant Express VI that communicates with message-based instruments and graphically parses the response.
L
label LabVIEW Text object used to name or describe objects or regions on the front panel or block diagram. Laboratory Virtual Instrument Engineering Workbench. LabVIEW is a graphical programming language that uses icons instead of lines of text to create programs. Light-emitting diode. Object a graph or chart owns to display the names and plot styles of plots on that graph or chart.
LED legend
M
MAX Measurement & Automation Explorer See Measurement & Automation Explorer. The standard National Instruments hardware configuration and diagnostic environment for Windows.
G-5
Glossary
DAQ devices such as the E Series multifunction I/O (MIO) devices, SCXI signal conditioning modules, and switch modules. Horizontal bar that lists the names of the main menus of an application. The menu bar appears below the title bar of a window. Each application has a menu bar that is distinct for that application, although some menus and commands are common to many applications.
N
NI-DAQ Driver software included with all NI DAQ devices and signal conditioning components. NI-DAQ is an extensive library of VIs and ANSI C functions you can call from an application development environment (ADE), such as LabVIEW, to program an NI measurement device, such as the M Series multifunction I/O (MIO) DAQ devices, signal conditioning modules, and switch modules. The latest NI-DAQ driver with new VIs, functions, and development tools for controlling measurement devices. The advantages of NI-DAQmx over earlier versions of NI-DAQ include the DAQ Assistant for configuring channels and measurement tasks for your device for use in LabVIEW, LabWindows/CVI, and Measurement Studio; NI-DAQmx simulation for most supported devices for testing and modifying applications without plugging in hardware; and a simpler, more intuitive API for creating DAQ applications using fewer functions and VIs than earlier versions of NI-DAQ. Program execution element. Nodes are analogous to statements, operators, functions, and subroutines in text-based programming languages. On a block diagram, nodes include functions, structures, and subVIs. Front panel objects to manipulate and display numeric data.
NI-DAQmx
node
O
object Operating tool Generic term for any item on the front panel or block diagram, including controls, indicators, structures, nodes, wires, and imported pictures. Tool to enter data into controls or to operate them.
G-6
ni.com
Glossary
P
palette plot Positioning tool project Displays objects or tools you can use to build the front panel or block diagram. Graphical representation of an array of data shown either on a graph or a chart. Tool to move and resize objects. A collection of LabVIEW files and files not specific to LabVIEW that you can use to create build specifications and deploy or download files to targets. Window in which you can create and edit LabVIEW projects. Dialog boxes accessed from the shortcut menu of a control or indicator that you can use to configure how the control or indicator appears in the front panel window. Menus accessed from a menu bar. Pull-down menu items are usually general in nature. PCI eXtensions for Instrumentation. A modular, computer-based instrumentation platform.
R
RMS Root Mean Square.
S
sample scale Single analog or digital input or output data point. Part of graph, chart, and some numeric controls and indicators that contains a series of marks or points at known intervals to denote units of measure. Menu accessed by right-clicking an object. Menu items pertain to that object specifically. Representation of a value as text.
G-7
Glossary
structure
Program control element, such as a Flat Sequence structure, Stacked Sequence structure, Case structure, For Loop, While Loop, or Timed Loop. Palette that you access from another palette that is above the subpalette in hierarchy. VI used on the block diagram of another VI. Comparable to a subroutine.
subpalette subVI
T
task A collection of one or more channels, timing, triggering, and other properties in NI-DAQmx. A task represents a measurement or generation you want to perform. VI that contains common controls and indicators from which you can build multiple VIs that perform similar functions. Access template VIs from the New dialog box. Object or region on a node through which data pass. Small yellow text banners that identify the terminal name and make it easier to identify terminals for wiring. Special cursor to perform specific operations. Bar that contains command buttons to run and debug VIs. An older driver with outdated APIs for developing data acquisition, instrumentation, and control applications for older National Instruments DAQ devices. You should use Traditional NI-DAQ (Legacy) only in certain circumstances. Refer to the NI-DAQ Readme for more information about when to use Traditional NI-DAQ (Legacy), including a complete list of supported devices, operating systems, and application software and language versions.
template VI
G-8
ni.com
Glossary
V
VI virtual instrument (VI) VXI See virtual instrument (VI). Program in LabVIEW that models the appearance and function of a physical instrument. VME eXtensions for Instrumentation (bus).
W
waveform waveform chart While Loop wire Wiring tool Multiple voltage readings taken at a specific sampling rate. Indicator that plots data points at a certain rate. Loop structure that repeats a section of code until a condition occurs. Data path between nodes. Tool to define data paths between terminals.
G-9
Index
A
acquiring information for instruments, 4-9 signals, 4-2 Acquiring a Signal VI block diagram (figure), 1-14 adding See also creating channels to tasks, 4-6 controls from the block diagram, 2-5 controls to the front panel, 1-6 graph indicators, 2-5 inputs to Express VIs, 1-9, 2-5, 3-15 multiple signals, 3-5 numeric indicators, 2-4 signals, 3-4 visual cues on front panel, 3-10 warning lights, 3-10 Amplitude and Level Measurements Express VI, 3-3 analyzing voltage, 3-9 analyzing signals, 3-9 applications building, 5-5 communicating with across networks, 5-4 Arithmetic & Comparison palette, 1-12 Build Table Express VI, 2-9 building applications, 5-5 shared libraries, 5-5 VIs, 1-2 buttons adding, 3-14 Run, 1-6
C
calling code from text-based languages, 5-4, 5-5 changing signal types, 1-8 channels, 4-3 adding to tasks, 4-6 renaming, 4-5 communicating with instruments, 4-7 with LabVIEW applications across networks, 5-4 Comparison Express VI, 3-11 configuration dialog boxes, 1-19 configuring controls, 1-20 indicators, 1-20 Context Help window, 2-2, 2-12, 3-3 button, 2-2, 3-3 displaying configuration of Express VIs, 3-3 displaying errors, 2-13 figure, 2-2 showing, 2-2 controlling execution speed, 2-8 VIs programmatically, 5-4 controls, 1-18, 3-17, 5-1 adding from the block diagram, 2-5 adding to the front panel, 1-6
I-1 Getting Started with LabVIEW
B
blank VIs, 2-2 block diagram, 1-6, 1-19 customizing, 2-13 indicators, 3-17 placing objects from help, 2-12 showing, 1-8 broken Run button, 2-8 wires, 2-8, 2-13
Index
configuring, 1-20 creating, 2-5, 2-13 customizing, 1-15 data types, 5-3 numeric, 5-1 palette, 1-6 Controls palette, 1-6 figure, 1-7 showing all categories, 5-1 conventions used in this manual, ix Convert from/to Dynamic Data Express VIs, 5-3 creating See also adding controls, 2-5, 2-13 graph indicators, 2-5 indicators, 2-13 NI-DAQmx tasks, 4-2 customizing block diagrams, 2-13 controls, 1-15 front panels, 2-4 indicators, 1-17 menus, 5-5 simulated signals, 3-4
data types dynamic, 5-3 overview, 5-3 deleting wires, 1-11 deselecting objects, 1-10 diagnostic tools (NI resources), A-1 displaying data from DAQ devices, 4-5 data in tables, 2-9, 2-14 errors in Context Help window, 2-13 signals in a graph, 1-14 documentation conventions used in this manual, ix introduction to this manual, ix NI resources, A-1 drivers instrument, 4-7 NI resources, A-1 drivers (NI resources), A-1 dynamic data, 5-3 converting from and to, 5-3
E
Error list window, 2-8, 2-13 errors, 2-13 displaying in Context Help window, 2-13 list, 2-8, 2-13 window, 2-8, 2-13 example VIs NI Example Finder, 2-11 examples (NI resources), A-1 Execution Control palette, 2-6 execution speed, controlling, 2-8 Express VIs, 1-19 Amplitude and Level Measurements, 3-3, 3-9 Build Table, 2-9 Comparison, 3-11 configuration dialog boxes, 1-19 Convert from/to Dynamic Data, 5-3 DAQ Assistant, 4-2, 4-11
I-2 ni.com
D
DAQ Assistant Express VI, 4-2, 4-11 DAQ devices, 4-3 data displaying from DAQ devices, 4-5 in tables, 2-9, 2-14 graphing from DAQ devices, 4-5 saving to a file, 3-13, 3-14 when prompted by a user, 3-15 storing, 3-14 data flow, 1-10, 1-14, 1-19
Index
Filter, 3-7 Formula, 1-12 inputs, 1-20 Instrument I/O Assistant, 4-8, 4-12 Scaling and Mapping, 1-12 Simulate Signals, 1-8 Time Delay, 2-8 Write To Measurement File, 3-13, 3-17
H
help Context Help window, 2-2, 2-12, 3-3 LabVIEW Help, 1-12, 1-20, 2-12 searching, 2-3, 2-10, 2-12 LabVIEW resources, 1-20, 2-12 searching, 2-4, 2-10, 2-12 technical support, A-1
F
files grouping, 5-5 saving to other formats, 5-4 Filter Express VI, 3-7 Formula Express VI, 1-12, 3-5 front panel, 1-5, 1-18 Acquiring a Signal VI (figure), 1-2 adding controls, 1-6 visual cues, 3-10 controls, 1-18, 3-17 customizing, 2-4 indicators, 1-19 modifying, 2-7 showing, 1-11 Warning Light VI (figure), 3-2 functions, 5-2 Merge Signals, 1-15, 2-5 Functions palette figure, 1-12 showing all categories, 5-2
I
indicators, 1-19, 3-17, 5-1 adding numeric, 2-4 configuring, 1-20 creating, 2-13 customizing, 1-17 data type, 5-3 numeric, 5-1 removing, 2-7 Input palette, 2-3 inputs, Express VI, 1-20 Instrument Driver Network, 4-7 instrument drivers, 4-7, 4-12 finding, 4-12 installing, 4-12 NI resources, A-1 Instrument I/O Assistant Express VI, 4-8, 4-12 instruments acquiring information, 4-9 communicating, 4-7 parsing information, 4-9 selecting, 4-9 introduction to this manual, ix
G
Getting Started window, 1-4, 3-2 figure, 1-3 graph indicators, creating, 2-5 graphing data from DAQ devices, 4-5 two signals, 1-14 grouping files, 5-5
K
knob control, customizing (figure), 1-16 KnowledgeBase, A-1
I-3
Index
L
LabVIEW help resources, 2-12 other features, 5-1 projects, 5-5 LabVIEW Help, 1-12, 1-20, 2-12 searching, 2-3, 2-10, 2-12 LEDs, palette, 3-10 figure, 3-10 LVM. See .lvm files .lvm files, 3-14, 3-17
P
palettes Arithmetic & Comparison, 1-12 Controls, 1-6 Execution Control, 2-6, 2-13 Functions, 1-12 Input, 2-3 LEDs, 3-10 searching, 2-6 showing all categories, 5-1, 5-2 parsing information for instruments, 4-9 placing objects on the block diagram from the help, 2-12 Positioning tool, 1-10 programmatically controlling VIs, 5-4 programming examples (NI resources), A-1 projects, 5-5 property dialog boxes, 1-20, 1-21 publishing VIs on the Web, 5-4
M
manual. See documentation marquee, 2-9 menus, customizing, 5-5 Merge Signals function, 1-15, 2-5 figure, 1-15 modifying front panels, 2-7 signals, 1-11, 2-3
N
National Instruments support and services, A-1 New dialog box, 1-4, 1-18, 3-2 figure, 1-5 NI Example Finder, 2-11 NI Instrument Driver Finder, 4-12 NI Instrument Driver Network, 4-7 NI-DAQmx tasks, 4-2, 4-11 creating, 4-2 numeric controls, 1-7, 5-1 palette, 1-7
R
related documentation, x removing indicators, 2-7 Run button, 1-6, 1-11 broken, 2-8, 2-13 running VIs, 1-11 continuously, 2-6
S
saving data different file formats, 5-4 Save Data VI block diagram (figure), 3-16 to files, 3-13, 3-14, 3-17 when prompted by user, 3-15, 3-16 Scaling and Mapping Express VI, 1-12 defining slope, 1-12
O
objects deselecting, 1-10 wiring on the block diagram, 1-10
I-4
ni.com
Index
searching examples, 2-11 help, 2-4, 2-10, 2-12 palettes, 2-6 selecting instruments, 4-9 objects, 1-10 shared libraries, building, 5-5 signals acquiring, 4-2 analyzing, 3-9 changing type, 1-8 graphing, 1-14 modifying, 1-11, 2-3 Simulate Signal Express VI, 1-8 simulated signals, customizing, 3-4 software (NI resources), A-1 subVIs, 5-2 system requirements, x
U
user interface. See front panel
V
virtual instruments. See VIs VIs, 1-1, 5-2 blank, 2-2 building, 1-2 customizing menus, 5-5 icons, 5-2 new, 2-2 programmatically controlling, 5-4 publishing on the Web, 5-4 running, 1-11 continuously, 2-6 subVIs, 5-2 template, 1-3, 1-4, 1-18 voltage, analyzing, 3-9
T
tables, 2-9 displaying data, 2-14 tasks adding new channels, 4-6 NI-DAQmx, 4-11 TDM. See .tdm files .tdm files, 3-17 .tdms files, 3-17 technical support, A-1 template VIs, 1-3, 1-4, 1-18 text-based languages, calling code, 5-4, 5-5 Time Delay Express VI, 2-8 tools Operating, 1-11 Positioning, 1-10 Wiring, 1-10 training and certification (NI resources), A-1 troubleshooting (NI resources), A-1
W
Warning Light VI block diagram (figure), 3-12 warning lights, adding, 3-10 Web resources, A-1 While Loop, 2-7 wires broken, 2-8, 2-13 deleting, 1-11 wiring objects on the block diagram, 1-10 tool, 1-10 Write to Measurement File Express VI, 3-13, 3-14, 3-17 saving data, 3-14
I-5