Auxillary Layout For 2 Storey Residential Building

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL ELECTRICAL NOTES

1. ALL PLANS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PLANS


AND SPECIFICATIONS.
2. THE WORK SHALL COMPLY WITH THE PROVISION OF THE LATEST EDITION
TELEPHONE CONCRETE
OF THE PHILIPPINE ELECTRICAL CODE LAWS, ORDINANCES,
SERVICE PEDESTAL
RULES AND REGULATIONS OF THE LOCALITY HAVING THE JURISDICTION
ENTRANCE
OVER THE PROJECT AND THE REQUIREMENT OF THE UTILITY COMPANY.
3. THE JOB SHALL BE DONE IN THE MOST THOROUGH PROMPT AND
WORKMANLIKE MANNER UTILIZING STANDARD TOOLS, EQUIPMENT,
METHODS AND GOOD ENGINEERING PRACTICE, THE JOB SHALL BE
DONE COMPLETE IN ALL ASPECT AS REQUIRED PER PLANS,
SPECIFICATIONS AND READY FOR THE OPERATION.
4. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO PRESENT A TPC
GENERAL LAYOUT AND BROAD OUTLINE DESCRIPTION OF THE PROJECT
BUT NOT NECESSARILY INDICATE DESCRIBE THE ACTUAL LOCATIONS,
LEVEL AND DISTANCES OF EQUIPMENT, THE CONTRACTOR IS HEREBY
DINING REQUIRED TO MAKE SUCH ADJUSTMENT AS LOCATIONS, LEVELS, AND LIVING AREA
AREA DISTANCES ARE GOVERNED BY ACTUAL CONDITION.
5. ALL MATERIALS TO BE USED SHALL BE OF BEST QUALITY AND BRAND
NEW AS SPECIFIED.
6. ANY DESCRIPANCY BETWEEN THE PLANS AND SPECIFICATIONS SHALL BE
BROUGHT IMMEDIATELY TO THE ATTENTION OF THE ENGINEER FOR GROUND FLOOR F.F.L.
PANTRY CLARIFICATION AND DECISION.
7. ALL CONDUIT SHALL BE CONCEALED INSIDE THE CEILING, FLOOR AND 1 - 20mm DIA. PVC
WALLS. WITH G.I. PULLWIRE
BEDROOM COMMON BEDROOM LIVING
8. USE ADEQUATE GROUNDING SYSTEM AND PROVIDE IF NECESSARY
1 T&B 2 AREA ADDITIONAL GROUND RODS TO MEET THE REQUIRED GROUND RESISTANCE.
9. ALL CONDUIT SHALL BE PROTECTED AGAINST DAMAGES BY THE ENTRANCE
TV
OF WATER AND FOREIGN MATERIALS DURING COSTRUCTION AND
ALL OF CONDUITS SHALL PLUGGED TO EXCLUDE MOISTURE AND DUST
IMMEDIATELY AFTER THE CONDUITS ARE PLACED.
10. ALL CONDUIT BENDS SHALL BE OF MINIMUM BENDING RADIUS AND
KITCHEN CONFORMS IN ACCORDANCE WITH THE CODE.
AREA 11. WALL SWITCHES SHALL BE RATED 15 AMP, 300 VOLTS TUMBLER TYPE AND 2 TYP. TELEPHONE RISER DIAGRAM
CONVENIENCE OUTLETS SHALL BE OF GROUNDING TYPE 3 - WIRE 230 VOLTS. E 1 SCALE NTS
12. UTILIZE PULL BOXES BUT DIMENSIONS SHALL BE COMPUTED BASED ON THE
CODE REQUIREMENTS.
13. UNLESS NOTED OTHERWISE IN THE DRAWING WIRING DEVICES SHALL BE
INSTALLED AS FOLLOWS:
LIGHT CONTROL SWITCH : 1.40 M. ABOVE FINISH FLOOR LINE
CONVENIENCE OUTLET : 0.30 M. ABOVE FINISH FLOOR LINE
W.I.C TELEPHONE OUTLET : 0.30 M. ABOVE FINISH FLOOR LINE
AIR CONDITION UNIT : VERIFY FROM ARCHITECT
14. CONDUCT INSULATION RESISTANCE TEST 500 M MINIMUM
15. USE GE KV2C CLASS 200 KWH METER
TV CATV CONCRETE
MASTER
SERVICE PEDESTAL
BEDROOM ENTRANCE

T&B
LEGEND
GARAGE
PB
1
CIRCUIT NUMBER S 123
THREE GANG SWITCH CATV-PB
PNL - 1

S 3W
PANEL BOARD THREE WAY SWITCH LIVING MASTER
AREA BEDROOM
LIGHTING CONVENIENCE OUTLET

PINLIGHT REF REFRIGIRATOR C C


DROPLIGHT ACU AIR-CONDITIONING UNIT OUTLET

FLOURESCENT
RA RANGE OUTLET GROUND FLOOR F.F.L.
S1
ONE GANG SWITCH TV TELEPHONE OUTLET
1 - 20mm DIA. PVC
S 12
TWO GANG SWITCH TELEVISION/CABLE OUTLET WITH G.I. PULLWIRE

AU ILIARY LAYOUT

1 GROUND FLOOR PLAN 3 CATV LINE RISER DIAGRAM


E 1 SCALE 1 MTS E 1 SCALE NTS

PROJECT TITLE PROJECT OWNER SHEET CONTENTS REVISIONS DRAWN BY DRAWING NO.
AUXILIARY LAYOUT - GROUND FLOOR PLAN -RCA-
MYRA MANALO, PECE, PhD
PROPOSED ONE STOREY RESIDENTIAL ARTHUR & MA. ELENA BANARIA
TYP. TELEPHONE RISER DIAGRAM
CATV LINE RISER DIAGRAM
GENERAL NOTES
CHECKED BY E 1
PROFESSIONAL ELECTRONICS ENGINEER
LEGENDS -MAM- SHEET NO.
PRC 000103 VALID UNTIL JANUARY 08, 2023
Manalo Consultancy Services LOCATION ADDRESS DATE
0922-811-0019
[email protected]
PTR
TIN NO.
3591684 DATE:
198-407-778 PLACE:
JANUARY 02, 2020
BATANGAS CITY BRGY. ANTIPOLO, LIPA, BATANGAS --- FEBRUARY 2021
1/1