Manual Contador RC102C
Manual Contador RC102C
Manual Contador RC102C
Programmable from 0.00001 to 9.99999x10n The RC102C toggles between RATE display and
RC102C n = -3, -2, -1, 0, 1, 2.
Short to select NPN sensor 1-2
TOTAL display at the momentary press of R/T ( )
Short to select PNP sensor 2-3
INPUTS key .In rate mode RATE LED glows & in totaliser
Count input 2 mode TOTAL LED glows.
3-30V DC from Proximity switches, Encoders,
Potential free contacts, Limit switches etc. +12V supply 4
SENSOR SUPPLY COM (GND) 6
In built 12V DC (±10%), 30 mA Reset input 5-6
INPUT SPEED Short to Filter input noise 6-7
1) 30 Hz RATE
Short to enter configuration 9 - 10
2) 2.5 kHz. press ( )
Please maintain these instructions and review Live - Neutral L (+) - N (-) key momentary
CONFIGURATION LOCK
them before using the unit:
via rear terminals.
RESET INPUT CONNECTIONS:
Warning:
1. This unit is panel mounted type with its 1) On front panel. PNP proximity sensor
2) Remote reset ( via rear terminals). PNP
output terminals getting connected to the TOTAL
O/P V+ GND
host equipment. Such equipment shall also MEMORY RETENTION
comply with basic EMI/EMC and safety 10 years. 1 2 3 4 5 6 RESETTING THE RC102C
requirements like BSEN 61326-1 and SUPPLY VOLTAGE (FACTORY SET) CNT +12V RST COM A. By front key: Press R/T key continuously
BSEN 61010 respectively. 90 to 270V AC/DC @ 50/60 Hz. Short 2 & 3
for 3 sec. The totaliser resets to zero and starts
2. To avoid electric shock, power supply of the 24V AC/DC (Optional) NOTE: For PNP sensor input, short terminals 2 & 3. counting again, and the display shows the rate
unit should be kept off while wiring. Wiring OPERATING TEMP. or total as per selection.
should be done strictly as per the terminal NPN proximity sensor
Operating: 0 to 50oC B. Remote reset:
layout, given in the manual. NPN
The RC102C can be reset from a remote push
Storage: 0 to 50oC
3. Use lugged terminals to meet M3.5 screws. O/P V+ GND
HUMIDITY button as shown in the figure below:
4. The unit does not have a built-in fuse. 1 2 3 4 5 6
External fuse with a rating of 275V AC/1A is 95% RH. Reset by potential free switch
CNT +12V RST COM
recommended. HOUSING Short 1 & 2
! Caution:
Flame retardant plastic. NOTE: For NPN sensor input, short terminals 1 & 2.
1. This unit is not intended for outdoor use. WEIGHT 1 2 3 4 5 6
250 gms. Potential free contact
2. The power connection cable must have a CNT +12V RST COM
cross-section of atleast 1mm 2 and insulation PANEL DIMENSIONS(dimensions in mm)
capacity of atleast 1.5kV. Panel Cutout
INITIALISATION:
1 2 3 4 5 6
3. The output connections must not be loaded Switch off the power. Short terminal no. 9 &10.
beyond the specified values/range. 45 46
CNT +12V RST COM Press key at the time of turning the power on.
48 Short 2 & 3
4. Avoid inflow of dust and contact of conductive The key must continue to remain pressed for
material with the internal circuitry of the unit. NOTE: Short terminals 2 & 3.
96
123 92
another 3 sec. When this sequence is correctly
5. The unit must not operate in presence of Sensor color codes:-
10 performed, the unit initialises and all parameters
heating sources, caustic vapors, oil, steam, Red = +12V, Green = CNT, Black = GND;
vibration or impact etc. MO
DEL IM A B C D E F G are set to factory settings.
D Brown = +12V, Black = CNT, Blue = GND.
6. Use clean soaked cloth cleaning. RC102C 50 97.5 10 88 45 46 92 Scale factor changes to 1 (mantissa = 1.0000 &
NOTE: exponent = 100=1), Resolution = 1, Maximum
SPECIFICATIONS: TERMINAL CONNECTION
In some applications, the proximity sensors may input frequency = 2500 Hz.Totaliser resets to 0.
DISPLAY SENSOR Short to filter
SELECTION
Type: 7 segment LED; Height: 0.5”. +12V RST
input noise
CONFIG
pick up high frequency noise form nearby After initialisation unit will go into configuration
NPN PNP COM FILTER
Counter: 6 digits, Rate: 4 digits. switching circuits like AC / DC drive, Due to this setting mode. To quit configuration setting
1 2 3 4 5 6 7 8 9 10 the counter may show erroneous reading. Short mode:
RANGE
terminals 6-7 for RC102C as shown in figure
Counter: 9999.99, 99999.9 & 999999. 22 CNT
24 1) Turn power off
above, to filter out high frequency spurious
Rate: Auto ranging (4.00 to 9999 RPM). 21 23 2) Remove link between terminal nos 9 & 10
pulses by limiting the input frequency to about
ACCURACY 200Hz (1200 RPM).
3) Turn power on.
11 12 13 14 15 16 17 18 N L
Rate: 0.05 % (± 2 count).
- + Operating/1108/RC102C/OP191-V04 (Page 1 of 2)
CONFIGURATION SCHEME 4. Press R/T key to select max.
input frequency
To enter configuration short terminals 9 & 10 R AT E TO TA L