2-Horizontal Vessel
2-Horizontal Vessel
Geometrical Description
Exchanger Geometry
Unit : ft
Length of Exchanger (L) : 30.00
Upper Exchanger Diameter (UD) : 4.00
Lower Exchanger Diameter (LD) : 4.00
Lower Exchanger Diameter (LD) : 10.00
Spacing between Exchanger (S) : 6.00
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 2 of 12
Footing Geometry
------------------------------------------------------
Design Parameters
Cover and Soil Properties
------------------------------------------------------
Load Description
Primary Load
Wind Load
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 3 of 12
Seismic Load
------------------------------------------------------
------------------------------------------------------
------------------------------------------------------
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 4 of 12
Pile Capacities
Axial Capacity PP = 100.000 kip
Lateral Capacity PL = 40.000 kip
Uplift Capacity PU = 40.000 kip
Material Properties
Concrete f'c = 432.000 kip/ft^2
Reinforcement fy = 8640.000 kip/ft^2
Channel End
Load Fx Fy Fz Mx My Mz
Case (kip) (kip) (kip) (kip-ft) (kip-ft) (kip-ft)
101 -0.000 63.600 0.000 0.000 0.000 0.000
201 -0.000 89.040 0.000 0.000 0.000 0.000
Shell End
Load Fx Fy Fz Mx My Mz
Case (kip) (kip) (kip) (kip-ft) (kip-ft) (kip-ft)
101 0.000 42.400 0.000 0.000 0.000 0.000
201 0.000 59.360 0.000 0.000 0.000 0.000
_ Arrangement Reaction
X Y Axial Lateral Uplift
Pile No.
(ft) (ft) (kip) (kip) (kip)
1 -7.500 -2.917 -77.884 0.000 0.000
2 0.000 -2.917 -66.982 0.000 0.000
3 7.500 -2.917 -56.081 0.000 0.000
4 -7.500 2.917 -77.884 0.000 0.000
5 0.000 2.917 -66.982 0.000 0.000
6 7.500 2.917 -56.081 0.000 0.000
Reinforcement Calculation
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 5 of 12
Punching shear force is calculated per CRSI method (Punching Shear = Applied Load + Self Weight - Pile reaction inside punching
perimeter)
= = 1.778
b0 = = 20.910 ft
1 -77.884 0.000
2 -66.982 -66.982
3 -56.081 -56.081
4 -77.884 0.000
5 -66.982 -66.982
6 -56.081 -56.081
1 0.000 0.000
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 6 of 12
2 0.000 0.000
3 -56.081 0.000
4 0.000 0.000
5 0.000 0.000
6 -56.081 0.000
Design Shear for One-Way Action (Shear Line Parallel to : 68.920 kip
Width) SOL
VC = = 140.444 kip
1 -77.884 0.000
2 -66.982 0.000
3 -56.081 0.000
4 -77.884 0.000
5 -66.982 0.000
6 -56.081 0.000
Design Shear for One-Way Action (Shear Line Parallel to : 18.285 kip
Length) SOL
VC = = 349.784 kip
= 1.000
b0 = = 6.308 ft
Shear Force
Pile No.
(kip)
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 7 of 12
d1 = = 0.000 ft
d2 = = 0.000 ft
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 8 of 12
Along Length
1 -155.767 0.000
2 -636.331 -435.384
3 -953.374 -785.132
4 -155.767 0.000
5 -636.331 -435.384
6 -953.374 -785.132
1 0.000 0.000
2 0.000 0.000
3 -112.162 0.000
4 0.000 0.000
5 0.000 0.000
6 -112.162 0.000
dBeta =
Maximum
Reinforcement = = 0.0135
Ratio (Rmax)
Minimum
As per ACI Cl.
Reinforcement = 0.0018
7.6.1.1,
Ratio (Rmin) =
Smin<= S <= 18 inch and selected bar size < selected maximum bar size. The reinforcement is accepted.
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 9 of 12
Along Width
1 -2.434 0.000
2 -2.093 0.000
3 -1.753 0.000
4 -434.850 -21.905
5 -373.984 -18.839
6 -313.118 -15.773
dBeta =
Maximum
Reinforcement = = 0.0135
Ratio (Rmax)
Minimum
As per ACI Cl.
Reinforcement = 0.0018
7.6.1.1,
Ratio (Rmin) =
Smin<= S <= 18 inch and selected bar size < selected maximum bar size. The reinforcement is accepted.
Along Length
1 -259.612 0.000
2 -725.640 0.000
3 -1028.149 0.000
4 -259.612 0.000
5 -725.640 0.000
6 -1028.149 0.000
dBeta =
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 10 of 12
Maximum
Reinforcement = = 0.0135
Ratio (Rmax)
Minimum
As per ACI Cl.
Reinforcement = 0.0018
7.6.1.1,
Ratio (Rmin) =
Along Width
1 -2.434 0.000
2 -2.093 0.000
3 -1.753 0.000
4 -434.850 -21.905
5 -373.984 -18.839
6 -313.118 -15.773
dBeta =
Maximum
Reinforcement = = 0.0135
Ratio (Rmax)
Minimum
As per ACI Cl.
Reinforcement = 0.0018
7.6.1.1,
Ratio (Rmin) =
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 11 of 12
Shear Capacities
ϕVcX = 187.023kip
ϕVsX = 163.682kip
ϕVcZ = 181.723kip
ϕVsZ = 89.462kip
Note- Actual stirrup provided is dependent upon design requirement and bar binding and positioning. So Stirrup provided in detail drawing may vary from designed stirrup requirements.
As total moment = 0.0, the pedestal will be designed for axial force only.
Ф = 0.650
2
Section Area (Ag) = 16.000 ft
Shear Capacities
ϕVcX = 185.847kip
ϕVsX = 163.682kip
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023
Heat Exchanger Foundation Design Page 12 of 12
ϕVcZ = 180.580kip
ϕVsZ = 89.462kip
Note- Actual stirrup provided is dependent upon design requirement and bar binding and positioning. So Stirrup provided in detail drawing may vary from designed stirrup requirements.
As total moment = 0.0, the pedestal will be designed for axial force only.
Ф = 0.650
2
Section Area (Ag) = 16.000 ft
file:///D:/1-Tech/142-Students%20group/Session%204/Reference/horizontal-vessel-pilec... 11/26/2023