blue’Log Driver
DESCRIPTION OF FUNCTIONS
Driver: blue’Log driver for supporting Huawei inverters and Smart Logger 1000.
COMMUNICATION
Max. number of inverters: blue’Log X-1000 blue’Log X-3000 blue’Log X-6000
1) 2)
50 100 100 2)
1)
Maximum of 31 inverters can be managed per bus interface. Connection of MX module RS485/422 is possible as an option. (Please
consider the software features of your blue'Log base module. Please take a look in the data sheet of blue'Log.)
2)
MX module RS485/422 is necessary because up to 31 inverters can be managed per bus interface. (Please consider the software features
of your blue'Log base module. Please take a look in the data sheet of blue'Log.)
POWER CONTROL
Active power control: Yes (also via Smart Logger 1000)
Reactive power control: Yes (also via Smart Logger 1000) 3)
Active/reactive power control is not supported by all inverter types. An exact list is available from the inverter manufacturer.
3)
Please consider the software features of your blue'Log base module. Please take a look in the data sheet of blue'Log.
3)
Q-methods do not get supported by Huawei inverters with the firmware V100R001.
4)
Only the Smart Logger must be configured (not the inverters). Please use the following settings:
- Protocol: Modbus TCP
- Interface: Ethernet
- IP Address: IP address of the Smart Logger
- Scan start: Inverter will be added automatically
The actually recorded values may vary due to the inverter model or the inverter firmware.
Please contact Sales for details of compatibility with inverters not listed.