The blue'Log driver supports communication with Huawei solar inverters and Smart Logger 1000 devices. It can manage up to 100 inverters depending on the blue'Log model and supports monitoring and controlling the inverters' active and reactive power output. Measurement values recorded include energy generation, voltages, currents, temperatures and more. The driver works with Huawei inverter firmware versions V100R001 through V200R002 and is compatible with inverter models like SUN2000-8KTL, SUN2000-10KTL and SUN2000-33KTL.

Uploaded by

kusuma.hrm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views3 pages

DB BlueLog Driver Huawei en

The blue'Log driver supports communication with Huawei solar inverters and Smart Logger 1000 devices. It can manage up to 100 inverters depending on the blue'Log model and supports monitoring and controlling the inverters' active and reactive power output. Measurement values recorded include energy generation, voltages, currents, temperatures and more. The driver works with Huawei inverter firmware versions V100R001 through V200R002 and is compatible with inverter models like SUN2000-8KTL, SUN2000-10KTL and SUN2000-33KTL.

Uploaded by

kusuma.hrm
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Huawei

blue’Log Driver

DESCRIPTION OF FUNCTIONS
Driver: blue’Log driver for supporting Huawei inverters and Smart Logger 1000.

COMMUNICATION
Max. number of inverters: blue’Log X-1000 blue’Log X-3000 blue’Log X-6000
1) 2)
50 100 100 2)

Max. number of Smart Logger: 1 (per blue’Log)


Communication interface: RS485, TCP (Smart Logger 1000)
Bus speed: 9600 bps
Protocol (transmission): 8N1

1)
Maximum of 31 inverters can be managed per bus interface. Connection of MX module RS485/422 is possible as an option. (Please
consider the software features of your blue'Log base module. Please take a look in the data sheet of blue'Log.)
2)
MX module RS485/422 is necessary because up to 31 inverters can be managed per bus interface. (Please consider the software features
of your blue'Log base module. Please take a look in the data sheet of blue'Log.)

POWER CONTROL
Active power control: Yes (also via Smart Logger 1000)
Reactive power control: Yes (also via Smart Logger 1000) 3)

Active/reactive power control is not supported by all inverter types. An exact list is available from the inverter manufacturer.

3)
Please consider the software features of your blue'Log base module. Please take a look in the data sheet of blue'Log.

3)
Q-methods do not get supported by Huawei inverters with the firmware V100R001.

Information subject to change, errors and omissions excepted / As at 12-2018 1/3


SUPPORTED INVERTER EQUIPMENT
Communication Gateway Smart Logger 1000 4)

4)
Only the Smart Logger must be configured (not the inverters). Please use the following settings:
- Protocol: Modbus TCP
- Interface: Ethernet
- IP Address: IP address of the Smart Logger
- Scan start: Inverter will be added automatically

MEASUREMENT VALUES RECORDED


E_DAY Daily energy
E_TOTAL Total energy
ERROR Error status
F_AC Grid frequency
I_AC (phase 1, 2, 3) AC current (phase 1, 2, 3)
I_DC (string A, B, C…) DC current (string A, B, C)
I_DC[1..x]_[1..x] Current DC [1…x] String [1…x]
P_AC AC active power
P_DC DC power
Q_AC Reactive power
STATE Operating status
T_WR Inverter temperature
U_AC (phase 1, 2, 3) AC voltage (phase 1, 2, 3)
U_AC_L1L2 Phase to phase voltage L1-L2
U_AC_L2L3 Phase to phase voltage L2-L3
U_AC_L3L1 Phase to phase voltage L3-L1
U_DC (string A, B, C…) DC voltage (string A, B, C)

The actually recorded values may vary due to the inverter model or the inverter firmware.

Information subject to change, errors and omissions excepted / As at 12-2018 2/3


SUPPORTED INVERTERS
V100R001 (Wechselrichter Firmware): SUN2000-8KTL SUN2000-10KTL SUN2000-12KTL
SUN2000-15KTL SUN2000-17KTL SUN2000-20KTL
SUN2000-23KTL SUN2000-25KTL SUN2000-28KTL

V200R001 (Wechselrichter-Firmware): SUN2000-30KTL-A SUN2000-33KTL SUN2000-33KTL-A


SUN2000-33KTL-E001 SUN2000-40KTL

V200R002 (Wechselrichter Firmware): SUN2000-24.7KTL-JP SUN2000-33KTL-JP SUN2000-33KTL-US


SUN2000-33KTL-A SUN2000-36KTL-US SUN2000-36KTL
SUN2000-40KTL-US SUN2000-40KTL-JP SUN2000-42KTL
SUN2000-43KTL-IN-C1 SUN2000-50KTL SUN2000-50KTL-C1

Please contact Sales for details of compatibility with inverters not listed.