Struc Notes
Struc Notes
IN GENERAL THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING REINFORCED CONCRETE
STRUCTURES SHALL BE ADHERED TO UNLESS OTHERWISE SHOWN OR NOTED.
1. ALL STRUCTURAL PLANS, SPECIFICATIONS, AND SHOP DRAWINGS,
SHALL MEET ALL REQUIREMENTS SET BY THE FF.: 4. CONTRACTOR SHALL NOTE & PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPTMENT & MECHANICAL BASES THAT
A.NATIONAL BUILDING CODE OF THE PHILIPPINES (1997C). ARE REQUIRED BY THE ARCHITECTURAL ELECTRICAL, ELECTRICAL, SANITARY & MECHANICAL DRAWINGS.
B. NATIONAL STRUCTURAL CODE OF THE PHILIPPINES
(5th Edition , 2001C). 5. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7) CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY
C.MANUAL OF STEEL CONSTRUCTION AISC. THE USE OF WET BURLAP FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS.
D. BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE ACI 318-77. C. REINFORCEMENT:
E. AND THE LOCAL CODE OF THE CITY/MUNICIPALITY/DISTRICT OF
1. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 40 FOR DIAMETER16 & SMALLER BARS & GRADE 40 FOR
2. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR DIAMETER 20 & LARGER BARS.
NOTED, MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. 2. SPLICES IN BEAMS, SPLICE HALF OF THE BARS AT 1/4 OF SPAN FROM FACE OF THE SUPPORT, & SPLICE THE OTHER HALF
AT 1/4 OF SPAN THE OPPOSITE SUPPORT
3. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, MISCELLANEOUS 3. SPLICES IN COLUMNS, SPLICE HALF OF THE BARS AT 1/2 OF THE COLUMN HEIGHT FROM THE BASE & SPLICE THE OTHER
IRON, PRE-CAST CONCRETE, ETC., SHALL BE SUBMITTED FOR THE ENGINEER/ DESIGNER'S APPROVAL BEFORE HALF AT 1/2 OF THE COLUMN HEIGHT OF THE SUCCEEDING FLOOR.
FABRICATION. 4. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE 1 (Table of Lap &
Splices & Anchorage Length) UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRACINGS OF THE POSSIBLE.
STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION. 5. ALL ANCHOR BOLTS, DOWELS, & OTHER INSERTS, SHALL BE PROPERLY POSITIONED & SECURED IN PLACE PRIOR TO PLACING
OF CONCRETE.
5.1 Roof Loads: Concrete = 23.60 kN/cm 6. ALL INTERSECTING BARS SHALL BE SECURED USING A NO. 16 TIE WIRE.
5.1.1 Dead Loads Steel = 70.80 kN/cm
Concrete = 23.60 kN/cm 5.2.2 Live Loads D. MASONRY:
steel = 70.80 kN/cm Residential = 2.0 kN/cm 1. ALL CONCRETE HOLLOW BLOCK (CHB) SHALL USE NON-LOAD BEARING CHB.
Roofing = 0.80 kN/sm Concentrated Load = 6.0 kN/cm 2. ALL PLASTER AND MORTAR MIXTURE SHALL USE CLASS "B"/ 1:3.
3. PROVIDE STIFFENER COLUMN FOR EVERY 3.0 M. DISTANCE. PROVIDE LINTEL BEAM FOR EVERY 3.0 M. HEIGHT.
B. CONCRETE
1. ALL MATERIALS & WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING CODE AMERICAN CONCRETE
INSTITUTE (ACI-318).
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT (28)
DAYS WITH CORRESPONDING MAXIMUM SIZE
AGGREGATE AND SLUMP AS FOLLOWS:
LOCATION 28 DAYS STRENGHT MAXIMUM PROPORTION
ALL CONCRETE MEMBERS 2,500 psi Class "C" / 1:3:6
KENNETH P. JAVIER
PROPOSED TWO-STORY HOUSE
Dasmarinas, Cavite
BILL GATES STRUCTURAL NOTES
A1