Programmable Multifunction The PMT-9 Multunction Programmable Transducer measures the soveral variables of an elecitic power system and processes them 0 Produce 4 analog output signals. 2 digital output signals are available for signaling the limits. The limits of the outputs can be set by individual ‘measurand or logically combine up to three measurand. The principle of measuring is Dedicated DSP Controlier for best calculation ot RMS values and Power The PMT-9 is equipped with USB serial port interface through which using the corresponding software one can connect, program. or access and ‘execute useful ancilary functions. The ancilary functions include a power system check, provision. for displaying the measured variably on a PC monitor, tho simulation of the outputs for tost purposes, ‘The PMT-9 ts also equipped with a RS 485 bus interface (MODBUS®). The RS 485 interface enables the user to determine the number of Variables to be supervised (up to the maximum available). The levels ofall internal power/ energy rmoters that have been configured can also be Viewed. Provision is made for programming the PMT-9 via the bus. A standard E1445 interface can beused, butthereis nodummy Features Simultaneous measurement of several variables of a heavy-current power system ! Full supervision of an asymmetrically loaded four Wire power system, rated current 1 10 6A, rated voltage 57 to 400V (phase-to-neutral) oF 100 to £693 V (phase-to-phase)For all heavy-current power system variables + Fully Programmable CT and PT Rato, + 4 analogue outputs * Digital Outputs + Conversion of a current to a volta Output or vice versa is also possible ‘without any hardware change. * Input voltage up to 893 V (phase-to-phase) ‘Universal analogue outputs (programmable) + High accuracy: UN 0.2% and P 0.25% (under reference conditions) + Windows software with password protaction for ming, data analysis, power system status simulation, eequistion of meter data and making settings ‘ACIDC power supply / Universal ‘Compact in size. Low Weight Provision for either snapping the transducer ‘onto top-hat ralls or securing It with screws to.a wal or pane! ‘+ Rated Burden Resistor up to 1K0 for 20mA. nsducer (PMT- New ee ns} eee hia kk & Applicable Standards EN 60888(2012) Is 12784 IEC 1010 or EN 61010 IEC 61326-1 Funetional Block Diagram: Electrical measuring transducers for ‘converting AC electrical variables into analog ‘and digital signals Electrical measuring transducers for converting ac Electrical Quantities into ce Electrical quantities - specification. ‘Safety regulations for electrical measuring, control and laboratory equipment + Electromagnetic compatiilty for Electrical Equipment for measurement, control and fs Symbols\Abbreviations Used Symbols Meaning x xo xt x ¥ yo Mt ye v Ur ui U23 ust UIN URN. USN uM Measured variable Lower imi of the measured variable Break porn ofthe measured variable Upper imi of the measurod variable Output variapie Lower imi ofthe output variable Bek pra the oul varias per imit f the output variable Input voltage Phaseorphase vtuge Lt Phase-rphase volage L2—L3 Phase-to-phase voltage L3—L1 Phase-to-neutral voltage Lt N Phase-to-neutral voltage L2 - N Phase-to-noutal vatago L3 —N ‘Average vale of Yhe vohages(UJIN+U2NSUAN) /3 input eurrent ‘currant Lt ‘8G current (2 AGeurent (3 ated value of the input current Average value Of ha curonts (11+ 2 + 13)/3 Average vale of the currents ad sign of the active power (P) Phase-shif between current and votage + Ermauency ofthe mpatvaracie Betwe power ofthe system P = PI + P2+P9 Active power phase 1 (phase neti FA - AActve power phase 2 (phase-to-neutal L2 — Active power phase 3 (phase-to-neutral L3 ~ N) Reactive power of the system @ = G1 + G2 + Ci Reactive power phase 1 (phase-to-neutral L1 — N) Reactive power phase 2 (phase-to-neutral L2 — N)} Renctve power phase 9 (phase-to-neutal L3— N Appatent power of tne system ; SAUL +12 +13) + VE V2 VS) Apparent power phase 1 (phase-to-neutral L1 —N) Apparent power phase 2 (phase-to-neutral L2 — N) Appatent power phase 3 (chase-o-neutral L3 — N) Fated value of te epparent power af the system Aetwe power factor 08 B= P/S Ace power lactor phase 1 cos @1 = P1/St ‘Acive power factor phase 2 cos 22 = P2/S2 fete power factor phase 3 60S 0 = Pa'S3 Reactive power factor sin = O'S eeactive power factor phase 3 sin @ 3= Q3S3 Power factor ofthe system LF = egnQ «(1 ~ I-PFI) Power factor phase { LE1 = sgnQt «(1 — PFI) Power factor phase 2 LF2 = sgnG2 - (1 — PFI) Power factor phase 3 LF3 = sgnG3 - (1 — PFI) Factor forthe intrinsic error Output load Rated burden Power supply Rated value of the power supply ct ratio Vi ratio iersurturnriy eatin tart nsducer (PMT-9) New PMT-9 with USB Connectivity rogrammable Multifunction re Transducer (PMT-9) Technical dat Inputs Input variables :U.U1N.U2N.UGN,U12,U29,US1,UM, 111,210, MIMS P.P1.P2,P3,0 1,02 03.5 51,5255, BF PFT PF2,PF3,QF OF OF2OFSLFLFI LF2LF9 Measuring ranges Ueasurand Tatil Value Final Value u Os x0 s 092 O8Ur s x25 12 Ur 1 0S x0 5 OK? OSs x2 51.5% POS | -x2sx0s 08x 035 x2/6ra15 PROF | =i 3X0 s (X2-08) Osx2s1 [[F “tie 50s 22) (02) 5 X25 65H Wave Sinusiea! Retesfeqeney | 80.8 10%) He ‘Continuous thermal ratings of input Ccunent rout BA a Natage ereut 480 V single-phase AC systems 600 V e-praso Systeme no | ‘Short-sime thermal rating of inputs Input Number] Duration ‘rienal beween| 3 y varicvo —| otinputs | ofoveroas | Two overcacs —tinear ‘Current circuit 10 GOA W- "0s Tos Ie zero SOA 8 ES Snir. Wattage creat 5 _ TOAC Hien z — aca 10 105 10 3O.AC ayslem : ° a ae 10 108 10 o 2 4 6 | Outputs : 4 analog outputs followng the corresponding process variable Digital outputs, pulse outputs, limit outputs Programmed through the software. Thoso signals can be eet in various : Patterns lite Linear, lve zero, bent. The outputs A, B, C and D may be ‘either short or open-circuted. They are electrically insulated from each ‘other and from all other circuits (Hoating). All the fullscala output values fs ean be reduced subsequertty using the programming software, ‘subjective a supplementary error results. Convarsion of a current to a voltage output cr vice versa is also possible without any hardware = change. Output signal | _tnllal valve XO Fralvahe 2 CC ament Yoro Y2=20mA ‘Type of contact : Open collector uelttit? | oxvozaa-ve | rmkcveioma Putco duration: 280me Interval :280ms vevetae | orvoroz've | yveveciov Power supply: 8...40¥ Bent Characteristics (applicable to both Voltage and Current Output) Output current: ON 10... 27 mA ior 0otS Se ex oa MeV SS te OFF s2mA Electrical connections Programmable Multifunction ‘Conneciton [Trminal Wo] Connection | Tarninal Ne. Va 2 _[wnaccorn | 10 w 5 | anncos ori a 7 ve wanaLocomes [at N 1i__[ anmosore | 2 ® 1 [@natocors: | 7 ie 3 [analooors [a ¥ 4 [| anatogores [25 | v 6 | anaocorm | 2 | 8 7_ | wrairat oF 1+ 18 ie 9 | @iemaL omy 6 AUX 13 | @iarTALOF2e 7 AUX, 14 | (wieraLor | 16 Wiring Diagram (eam sunbsees Environmental ‘Working Temperature Sos Storage “1010 470 dogo Folatve Huricty (0 98% non eondonsing ibation/ Shock 129. 1055-10H2 woot 4068 gr Safety Protection Ginss se IP Rating 120 (Over Vatlge Cat cat Insulation Test Vs Earth S00 Surge Tost ‘KY, 12800, SWS HV Toet ote Op iclaton aKV ‘bp tip ialaton 500 v 2x Conwunicaton Inerace (USB S285) to alcicu 2KV ‘MODBUS ( Data Communication) BUS intorace Si66. ormnal tug in Type Phoonk connecter Max Distenco 200m, ‘No. OF Bus Stations Up 248 inclusing Master. Bury led Not required USB ( Transducer Conf USB Details juration) ‘Data comrunicatons to PC via USB Min Type B at RS 200 bavi rate fr coniguraon of PMT 9 {USB Connector : USB Female B-Type Conneccr. Software CD containing Driver and ‘incows based Sofware for Configuration of PAT=2 ie supped ‘long wth the Box Pack FAL =x ce

You might also like