Our Technical File I 410 1
Our Technical File I 410 1
Our Technical File I 410 1
WWW.PRECIAMOLEN.COM
Internal measurement board Communication
Analog measurement board Serial link
Input division ........................................................................................... 0.5 μV RS 232 serial link
Number of divisions ......................................................................... 200 000 RS 422/485 serial link
(Non Trade Use)
Load cell junction: Field bus
• Nominal power supply................................................................ 5 V DC
Ethernet Modbus-TCP
• Junction .......................................................................................... 4/6 wire shield
• Minimum impedance................................................................... 58 Ω
WWW.PRECIAMOLEN.COM
• Maximum impedance.................................................................. 1 245 Ω PROFIBUS-DP
• Maximum cable length............................................................... 150 m
(0.68 mm²)
• Connection ....................................................................... Spring terminals
• Dead load minimum signal..................................................... 0 mV
• Useful maximum signal ............................................................ 12 mV Inputs/Outputs
N° of measurements available per second ............... 7 to 120 2 digital inputs/4 digital outputs I 410 D-S
• Inputs: I 410 D
Adjustable filtering modes and parameters
Input tension ................................................................................... 8-30 V DC
This option enables connecting 4 to 6* load cells via an external • Outputs:
junction box. Max. power / contact ................................................................. 100 mA
Max. tension. ....................................................................................... 48 V DC
Digital measurement board (PMNet)
Ron ................................................................................................................ 15 Ω
TU NTU
1 analog input/2 analog outputs 4-20 mA or 0-10 V
Accuracy class (TU only) III -
Maximum number of divisions: (isolation 500 V / system)
• mono-range 10 000 30 000 • Input and outputs:
• double-range 2 x 10 000 - Input impedance.......................................................................... 440 Ω I 410 D-T
Power tension 24 V DC Load resistance** .................................................................... 500 Ω
Load impedance Accuracy ............................................................................................ 0.1 %
Number of physical measurement chan- 1 to 3 depending on Resolution ......................................................................................... 16 bits
nels configuration
7 (channels resulting
Presentation Available models
DSD
Number of channels from the combination
of 3 physical channels) The I 410 Graphic Terminal is part of the PRECIA MOLEN I 410 The I 410 graphic terminal range is made up of the various
Weigh data storage device for 38 000 or 128 000 records.
Maximum n° of load cells per channel 12 range. It is the central man/machine interface item. models below.
Max permissible error distribution factor 0 Speed sensor board (continuous weighing) I 410 D: panel-mounted terminal in cabinet or console.
It encloses a wide software library to meet most needs related to
Summation board 1 speed sensor input to be used with any type of 24 V D dosing, tolerance check, check weighing, continuous totalling, I 410 D-S: terminal in waterproof stainless steel casing
supplied detector (selection by jumper): etc... adapted to a use nearest the work station as possible in harsh
Allows the summation of 2, 3 or 4 analog or digital measurement • NPN/PNP commutation threshold ................................. 10 - 14 V environments.
channels. Moreover, with its PLC-oriented software workshop, a specific
• 2-wire type - Load resistance............................................. 2.2 kΩ I 410 D-T: terminal for tabletop use.
application can be developed to perfectly adapt to:
The summed channels can correspond to internal measurement 1 input (selection by jumper)
existing equipment (PLC, field bus, protocol, ...), All these terminals are available in digital or alphanumeric
boards or internal transmitters. • Logical input:
specific functionalities (production chain peripheral keyboard versions.
Input impedance.............................................................................. 17.2 kΩ
Possibility to have 2 measurement boards and one summation commands, data acquisition and processing, ...),
board in every terminal (analog/digital combination possible). Input tension ....................................................................................... 24 V DC
• 2-wire detector input - Impedance ............................. 1.5 kΩ IT interconnections (outsourced information feedback and Trade Use certification
processing).
Power supply • 4-20 mA input - Impedance ............................................... 150 Ω Certification according to the 2009/23/CE Directive relative
I 410 D-S: 24 V - 1.1 A internal power 1 isolated logical output: Depending on the application, the terminal can be connected to to Non Automatic Weighing Instruments: 6 000 divisions
various external weight transmitters or be equipped with internal (single or double-range) and 3 000 divisions (multi-division).
I 410 D-T: 24 V - 1.1 A or 2.3 A tabletop external power • Max. power............................................................................................ 125 mA
measurement boards that turn the terminal into a multi-channel
• Max. tension ......................................................................................... 48 V DC Certification according to the MID 2004/22/CE Directive rela-
I 410 D: DIN rail 24 V - 2 A external power weight indicator.
• Ron ................................................................................................................ 25 Ω tive to Automatic Weighing Instruments:
100-240 V - 50/60 Hz primary for all models. • Checkweighers: XIII(1) et Y(a) classes
European compliance • Continuous totalisers (dynamic weighing): 0.5 and 1 classes
* Or 8 high impedance load cells. ** sur sorties • Discontinuous totalisers (with non constant weigh): 0.25,
04-41-00-1 FT - 03/2015
2004/108/EC Directive relative to Electromagnetic Compati- 0.5, 1 and 2 classes.
bility.
Your specialist Illustrations not contractual. Precia-Molen reserves the right to alter the characteristics of the equipment described in this brochure • Automatic gravimetric filling: functional accuracy class X(x)
at any time..
2006/95/EC Directive relative to Low Tension equipments. x = 0.2 - 0.5 - 1 or 2 depending on on-site test results.
PRECIA-MOLEN Headquarters & Factory
BP 106 - 07000 Privas - France
Tel. 33 (0) 475 664 600
Fax 33 (0) 475 664 330
E-MAIL [email protected]
WWW.PRECIAMOLEN.COM
1 Electrical features
5 Max. thickness: 6 mm
2
Regulated power supply
• Power tension................................................................. 12 - 30 V DC Casing model
• Consumption .................................................................. 5 W*
6 • Connection ....................................................................... Spring terminals Dimensions
Environment
Temperature range
• In operation ....................................................................... - 10 °C / + 40 °C
• Storage ................................................................................ - 20 °C / + 60 °C • Waterproofness: IP 66
• Weight: approx. 4.3 kg
External keyboard / bar code reader
1
Possibility to connect a PC-type keyboard or a bar code reader
2 (on 8pt DIN female plug).
1
2
6 Tabletop model