Issued For BP - Structural - 19

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Copyright Reserved.

N This plan and design are, and at all times remain the exclusive
property of Glotman Simpson Consulting Engineers and cannot
be used or reproduced without written consent. Written
1 2 3 4 5 6 7 8 9 10 11 12 13 14 dimensions shall have precedence over scaled dimensions.
Contractors shall verify and be responsible for all dimensions
6550 5400 4237 8024 3939 5400 5400 5400 6400 5400 8100 8100 7600 and conditions on the job and this office shall be informed of
any variations from the dimensions and conditions shown on
the drawings.

Sketches may be issued which augment or alter the information


PROJECT NORTH presented on this drawing. It is the responsibility of parties
using this drawing to ensure that they are in possession of all
such sketches.

Drawing Issue Date

Revision Schedule
A Rev # Date Description
A APR 09, ISSUED FOR BULDING PERMIT
2020

4500
A1

1550
B

175 SLAB
MINIMUM THICKNESS AT DRAIN

SR
MAX 100 BUILD-UP FOR SLOPE

1A
TO DRAIN - CAST MONOLITHIC

-1
0

6700
SR
SR O

3B
(L

3B NLY

-1
5

0
-1 )
0

L5 RE 0
1
D
ON OT A-
) Q'
(N R 3

0
S

-1
1A
SR
C

L5 RE 10
D
ON OT 3A-
) Q'
(N R
S
200 SLAB
TYP U/N TYP TYP

5900
SR

1 2
3A
-1

S602 S602
0

DN 200 SLAB
UP 3 4 MINIMUM THICKNESS AT DRAIN
S602 S602 MAX 100 BUILD-UP FOR SLOPE
TO DRAIN - CAST MONOLITHIC
TYP TYP

1
D

0
-1
S607

3A
SR
TYP
UP
DN
P.
TY

5900
S602
SR
3A
-1
0

0
-1
3A
0

SR
-1
3A
E

SR

SR
1A
-1
APR 09, 2020

0
ON -10
)
3B

LY
SR

6700
0
5

-1
(L

3A
SR

SR
1A
-1
0

TYP
. F

1575
6
. S602
TYP
7 F1
S602

4475
G

-
CONCRETE OUTLINE - LEVELS 05 TO 08
1 : 100
NOTES:
200 SLAB TYPICAL U/N

1. CLEAR COVER TOP - 20


2. CLEAR COVER BOTTOM -25
3. TEMPERATURE REBAR -SEE GENERAL NOTES, S100 SERIES DWGS.
PROVIDE TEMPERATURE REBAR BOTTOM UPPER LAYER WITH Client
STAGGERED TENSION LAPS IN ALL SLAB AREAS U/N. PROVIDE
TEMPERATURE REBAR TWO DIRECTIONS BOTTOM IN ALL SLAB
AREAS WHERE BOTTOM STEEL IS NOT OTHERWISE INDICATED,
INCLUDING CANTILEVERED SLABS.
4. REBAR MAY BE SHOWN ON SECTIONS AND NOT SHOWN ON PLANS
SEE SECTIONS.
5. FOR TYPICAL DETAILS SEE S600 SERIES DRAWINGS
6. CONFIRM ALL SLAB ELEVATIONS, STEPS, SLOPES, AND OPENINGS
WITH ARCHITECTURAL AND OTHER CONSULTANT DRAWINGS. Project
7.
8.
ROUGHEN SLABS AT SHEARWALL INTERFACES.
BALCONIES AND ROOF AREAS TO BE SLOPED TO DRAIN.
1350 JOHNSTON
9.
SEE ARCHITECTURAL FOR CONCRETE OUTLINES AND SLOPES.
PROVIDE TAPERED TOPPING ON SLAB AT BALCONIES TO DRAIN
ROAD, WHITE
(SEE ARCH. - MAX. 38mm THICK)
10. PROVIDE CAMBER TO SLABS AS SHOWN AND AS INDICATED
ROCK, BC
IN THE GENERAL NOTES. Drawing Title
11. PROVIDE NON-STRUCTURAL TOPPING AS REQUIRED TO ACHIEVE
BOTH ARCHITECTURAL FLATNESS REQUIREMENTS AND
FLOOR FINISH TOLERANCES.
LEVELS 05 TO 08
12. RESHORE TO CAST UPSTANDS OR WALLS ABOVE. OUTLINE
13. PROVIDE SHORING AND RE-SHORING PROCEDURES TO ENSURE
LEGEND: CONSTRUCTION LOADS DO NOT EXCEED THE SPECIFIED
DESIGN LIVE LOAD. SEE GENERAL NOTES.
Date: Project No.
SEE DRAWING S111 FOR LEGEND 14. FOR ALL DRAINAGE AND WATERPROOFING SEE ARCH.
Project Number
GSC-NTS1E-8
Scale Drawing No.