Viva
Viva
IMPORTANT QUESTIONS
1. A synchronous generator and synchronous motor each rated at 25 MVA and 11KV having 15 % sub
transient reactance are connected through transformer and line as shown. The transformer is rated for
25 MVA 11/66 KV and 66/11 KV with leakage reactance of 10%. The line has reactance of 10% on
the base of 25 MVA and 66 KV. The motor is drawing 15 MW at 0.8 pf leading and terminal voltage
is 10.6KV .when symmetrical three phase fault occurs at the terminal of motor. Find the sub transient
current in generator, motor and fault.
1. A delta connected balanced resistive load is connected across an unbalanced three phase supply.
where the current in line A is 10A at angle (30 degree) and current in line B is 15A at angle
(-60degree). Find the symmetrical components of line currents also find the symmetrical components
of delta currents
2. What are the various assumption in development of sequence network of transformer.
VIVA INSTITUTE OF TECHNOLOGY
Department of Electrical Engineering
IMPORTANT QUESTIONS
3. Derive the sequence network for one conductor and two conductor open condition from circuit
conditions and symmetrical components.
4. Discuss the phase shift of symmetrical components in star delta transformer.
5. Discuss the sequence networks of Synchronous Machine.
1. State different types of Faults takes place in electrical power system and explain each in 2 sentences
2. Derive the equation for fault current for Single Line to Ground Fault. State the various assumptions.
Draw the sequence network for same.
3. Derive the equation for fault current for Line to Line Fault. State the various assumptions. Draw the
sequence network for same.
4. Derive the equation for fault current for Double Line to Ground Fault. State the various assumptions.
Draw the sequence network for same
5. Which Type Of Fault/fault occurs frequently? And Why?
6. A 25 MVA 13.2 KV alternator with solidly grounded neutral has sub transient reactance of 0.25 pu.
The negative and zero sequence reluctances are 0.35 and 0.1 pu respectively. A single line to ground
fault occurs at the terminals of an unloaded alternator; determine fault current and line to line
voltages. Neglect resistance.
IMPORTANT QUESTIONS
4. Explain construction and working of following: 1. Thyrite type Surge Arrester 2. Metal Oxide
Gapless Arrester
5. Explain how lightning arresters are selected and discuss the best location to place lightning arresters.
6. Calculate the voltage and current rating of an arrestor if it is placed at the end of line and at the
junction of two lines. Draw the equivalent circuit for the same.
MODULE 6: Corona