XCJQCQ Hydraulic Filtersenlow Mediumpressure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 152

HYDRAULIC FILTRATION

PRODUCTS
LOW & MEDIUM PRESSURE FILTERS

PASSION TO PERFORM
A WORLDWIDE LEADER IN THE FIELD
OF HYDRAULIC FILTRATION EQUIPMENT.

Our company started life in 1964, when Bruno Pasotto decided


to attempt to cater for the requests of a market still to be fully
explored, with the study, design, development, production and
marketing of a vast range of filters for hydraulic equipment,
capable of satisfying the needs of manufacturers in all sectors.
The quality of our products, our extreme competitiveness
compared with major international producers and our constant
activities of research, design and development has made us a
worldwide leader in the field of hydraulic circuit filtering.
Present for over 50 years in the market, we have played a
truly decisive role in defining our sector, and by now we are
a group capable of controlling our entire chain of production,
monitoring all manufacturing processes to guarantee superior
quality standards and to provide concrete solutions for the rapidly
evolving needs of customers and the market.

1
MARKET LEADER
Our work is based on a skillful interaction between advanced
technology and fine workmanship, customizing products
according to specific market requests, focusing strongly
on innovation and quality, and following every step in
the manufacturing of both standard and special products,
fully respecting customer expectations.

Our customer-oriented philosophy, which enables us to


satisfy all customer requests rapidly and with personalized
products, makes us a dynamic and flexible enterprise.
The possibility of constantly controlling and monitoring
the entire production process is essential to allow us
to guarantee the quality of our products.

Introduction 2
WORLDWIDE PRESENCE
Our foreign Branches enable us to offer a diversified
range of products that allow us to successfully face
the aggressive challenge of international competition,
and also to maintain a stable presence at a local level.

The Group boasts 8 business branches

UNITED KINGDOM RUSSIA


GERMANY
CANADA
FRANCE
USA ITALY
P.R. CHINA

INDIA

3 Introduction
TECHNOLOGY

Our constant quest for excellence in quality


and technological innovation allows us to offer
only the best solutions and services for applications
in many fields, including general industry, test rigs,
l u b r i c a t i o n , h e a v y e n g i n e e r i n g, r e n e w a b l e
energies, naval engineering, offshore engineering,
aviation systems, emerging technologies and mobile
plant (i.e. tractors, excavators, concrete pumps, platforms).

Introduction 4
AND PRODUCTION

Our high level of technological expertise means we can


rely entirely on our own resources, without
resorting to external providers. This in turn enables
us to satisfy a growing number of customer requests,
also exploiting our constantly updated range of machines
and equipment, featuring fully-automated
workstations capable of 24-hour production.

5 Introduction
SUCTION RETURN RETURN / SPIN-ON LOW & MEDIUM HIGH
FILTERS FILTERS SUCTION FILTERS PRESSURE PRESSURE
FILTERS FILTERS FILTERS

Flow rates Flow rates Flow rates Flow rates Flow rates Flow rates
up to 875 l/min up to 3000 l/min up to 300 l/min up to 365 l/min up to 3000 l/min up to 750 l/min

Mounting: Pressure Pressure Pressure Pressure Pressure from 110 bar


- Tank immersed up to 20 bar up to 80 bar up to 35 bar up to 80 bar up to 560 bar
- In-Line
- In tank with Mounting: Mounting: Mounting: Mounting: Mounting:
shut off valve - In-Line - In-Line - In-Line - In-Line - In-Line
- In tank - Tank top - Tank top - Tank top - Parallel manifold version - Manifold
with flooded suction - In single - In single - In single
and duplex designs and duplex designs and duplex designs

Introduction 6
PRODUCT RANGE
MP Filtri can offer a vast and articulated range of products for the global market, suitable for all
industrial sectors using hydraulic equipment.

This includes filters (suction, return, return/suction, spin-on, pressure, stainless steel pressure)
and structural components (motor/pump bell-housings, transmission couplings, damping rings,
foot brackets, aluminium tanks, cleaning covers).

We can provide all the skills and solutions required by the modern hydraulics industry to monitor
contamination levels and other fluid conditions.

Mobile filtration units and a full range of accessories allow us to supply everything necessary for a
complete service in the hydraulic circuits.

STAINLESS STEEL CONTAMINATION MOBILE POWER TANK


HIGH PRESSURE MONITORING FILTRATION TRANSMISSION ACCESSORIES
FILTERS PRODUCTS UNITS PRODUCTS

Flow rates up to 125 l/min - Online, in-line particle counters Flow rates from 15 l/min - Aluminium bell-housings - Oil filler and
Pressure from 320 bar - Off-line bottle sampling up to 200 l/min for motors air breather plugs
up to 1000 bar products from 0.12 kW to 400 kW - Optical and electrical
- Fully calibrated using relevant - Couplings in Aluminium level gauges
Mounting: ISO standards Cast Iron - Steel - Pressure gauge valve
- In-Line - A wide range of variants to - Damping rings selectors
- Manifold support fluid types and - Foot bracket - Pipe fixing brackets
- In single and duplex designs communication protocols - Aluminium tanks - Pressure gauges
- Cleaning covers

7 Introduction
HYDRAULIC FILTRATION PRODUCTS

1 page INTRODUCTION
1 COMPANY
6 PRODUCT RANGE
11 CONTAMINATION MANAGEMENT
22 FILTER SIZING
24 CORRECTIVE FACTOR

up to Qmax
28 page SUCTION FILTERS l/min gpm

31 STR & MPA - MPM Submerged suction filter, with bypass or magnetic column 875 231
39 SF2 250 - 350 Semi-submerged positive head suction filter, low flow rate 160 42
47 SF2 500 Semi-submerged positive head suction filter, high flow rate 800 211
57 CLOGGING INDICATORS

up to Pmax up to Qmax
60 page RETURN FILTERS bar psi l/min gpm

63 MPFX Tank top semi-immersed filter, standard filter element disassembly 8 116 750 198
91 MPLX Tank top semi-immersed filter, standard filter element disassembly 10 145 1800 476
99 MPTX Tank top semi-immersed filter, easy filter element disassembly 8 116 300 79
117 MFBX Bowl assembly 8 116 500 132
125 MPF Tank top semi-immersed filter, standard filter element disassembly 8 116 750 198
153 MPT Tank top semi-immersed filter, easy filter element disassembly 8 116 300 79
171 MFB Bowl assembly 8 116 500 132
179 MPH Tank top semi-immersed filter, standard filter element disassembly 10 145 3000 793
203 MPI Tank top semi-immersed filter, standard filter element disassembly 10 145 3000 793
215 FRI Tank top semi-immersed filter, easy filter element disassembly, it can be used also as in-line filter 20 290 1500 396
231 RF2 Semi-immersed under-head filter, easy filter element disassembly 20 290 350 92
238 CLOGGING INDICATORS
248 ACCESSORIES

up to Pmax up to Qmax
250 page RETURN / SUCTION FILTERS bar psi l/min gpm

Unique TANK TOP filter for mobile machinery, with combined filtration on
253 MRSX 10 145 300 79
return and suction to the inlet at the hydrostatic transmissions in closed circuit
Unique IN-LINE filter for mobile machinery, with combined filtration on return
265 LMP 124 MULTIPORT 80 1160 200 53
and suction to the inlet at the hydrostatic transmissions in closed circuit
273 CLOGGING INDICATORS

up to Pmax up to Qmax
286 page SPIN-ON FILTERS bar psi l/min gpm

Low pressure filter, available with single cartridge (CS) for in-line or flange
289 MPS 12 174 365 96
mounting or with two cartridge on the same axis on the opposite sides
305 MSH In-line low and medium pressure filter available with single cartridge (CH) 35 508 195 52
311 CLOGGING INDICATORS

Introduction 8
INDEX
up to Pmax up to Qmax
322 page LOW & MEDIUM PRESSURE FILTERS bar psi l/min gpm

325 LMP 110 - 120 - 123 MULTIPORT In-line filter with Multiport design for multiple choice connection 80 1160 200 53
341 LMP 210 - 211 In-line low & medium pressure filter, low flow rate 60 870 330 87
351 LMP 400 - 401 & 430 - 431 In-line low & medium pressure filter, high flow rate 60 870 740 195
363 LMP 950 - 951 In-line filter, available with 2 and up to 6 different heads 30 435 2400 634
371 LMP 952 - 953 - 954 In-line low pressure filter specifically designed to be mounted in series 25 363 3000 793
383 LMD 211 In-line duplex medium pressure filter 60 870 330 87
391 LMD 400 - 401 & 431 In-line duplex low pressure filter 16 232 590 156
407 LMD 951 In-line duplex filter, available with 2 up to 6 different heads 16 232 1200 317

415 Filter elements designed according to DIN 24550


417 LDP - LDD In-line and duplex medium pressure filter 60 870 330 87
427 LMP 900 - 901 In-line low pressure filter 30 435 2000 528
435 LMP 902 - 903 In-line filter specifically designed to be mounted in series 20 290 3000 793
444 CLOGGING INDICATORS
450 ACCESSORIES

up to Pmax up to Qmax
452 page HIGH PRESSURE FILTERS bar psi l/min gpm

455 FMP 039 Filter high pressure, low flow rate applications 110 1595 80 21
463 FMP Filter high pressure, high flow rate applications 320 4641 475 125
475 FHP Typical high pressure filter for mobile applications, high flow rate 420 6092 750 198
493 FMM Typical high pressure filter for mobile applications, low flow rate 420 6092 250 66
503 FHA 051 Filter optimized for use in high pressure operating systems, low flow rate 560 8122 140 37
511 FHM High pressure filter with intermediate manifold construction 320 4641 450 119
529 FHB High pressure for block mounting 320 4641 485 128
543 FHF 325 In-line manifold top mounting 350 5076 500 132
553 FHD In-line duplex high pressure filter 350 5076 345 91
566 CLOGGING INDICATORS

up to Pmax up to Qmax
574 page STAINLESS STEEL HIGH PRESSURE FILTERS bar psi l/min gpm

577 FZP In-line pressure filter with threaded mount 420 6092 150 40
587 FZH In-line pressure filter with threaded mount for higher pressure 700 10153 50 13
597 FZX In-line pressure filter with threaded mount up to 1000 bar 1000 14504 10 3
605 FZM Manifold top mounting 320 4641 70 18
613 FZB Manifold side mounting 320 4641 75 20
621 FZD Duplex pressure filter for continuous operation requirements 350 5076 90 24
631 CLOGGING INDICATORS

636 page CLOGGING INDICATORS


639 QUICK REFERENCE GUIDE

9 Introduction
FILTER SIZING Calculation
THE CORRECT FILTER SIZING HAVE TO BE BASED ON THE TOTAL Calculation:
PRESSURE DROP DEPENDING BY THE APPLICATION. ∆pc = 0.24 bar (see graphic below)
THE MAXIMUM TOTAL PRESSURE DROP ALLOWED BY A NEW AND CLEAN Filter housings ∆p
LOW & MEDIUM PRESSURE FILTER HAVE TO BE IN THE RANGE 0.1 ÷ 0.9
LMP 210 Δp Housing pressure drop.
0.6 bar IN FUNCTION OF THE APPLICATION. 1” 1 1/4” 1 1/2” The curves are plotted
using mineral oil with
0.6 density of 0.86 kg/dm3
The pressure drop calculation is performed by adding together the value of

∆p bar
in compliance
the housing with the value of the filter element. The pressure drop ∆pc of with ISO 3968.
0.3 ∆p varies proportionally
the housing is proportional to the fluid density (kg/dm3); all the graphs in the * with density.
catalogue are referred to mineral oil with density of 0.86 kg/dm3.
0
The filter element pressure drop ∆pe is proportional to its viscosity (mm2/s), 0 80 160 240 320 400
the corrective factor Y have to be used in case of an oil viscosity different Flow rate l/min
than 30 mm2/s (cSt).
LMP 211 Δp
∆pe
0.9 = (0.7 : 1000) x 120 x (46 : 30) = 0.13 bar
Sizing data for single filter element, head at top 1” 1 1/4” 1 1/2”
∆pc = Filter housing pressure drop [bar] Filter
0.6 Absolute filtration Nominal filtration
element N - W Series N Series
∆pe = Filter element pressure drop [bar]
Y = Corrective factor Y (see correspondent table), depending on the filter type, Type
0.3 A03 A06 A10 A16 A25 P10 P25 M25
on the filter element size, on the filter element length and on the filter media
Q = flow rate (l/min) 1 0 16.25 15.16 8.75 8.14 5.87 2.86 2.65 0.14
V1 reference oil viscosity = 30 mm2/s (cSt) CU 110 2
0 12.62
80 10.44
160 6.11
240 6.02
320 4.15400 1.60 1.49 0.12
V2 = operating oil viscosity in mm2/s (cSt) 3 8.57 7.95 5.07 4.07 2.40 1.24 1.15 0.11
Valves 4 5.76 4.05 2.80 2.36 1.14 0.91 0.85 0.05
Filter element pressure drop calculation with an oil viscosity Bypass valve pressure drop
different than 30 mm2/s (cSt) 1 5.30 4.80 2.00 1.66 1.32 0.56 0.43 0.12
∆pe = Y : 1000 x Q x (V2:V1) LMP 210/211
CU 9210 2 3.44 2.95 1.24 1.09 0.70 0.42 0.35 0.09
∆p Tot. = ∆pc + ∆pe
3 2.40 1.70 0.94 0.84 0.54 0.33 0.23 0.05
6
Verification formula
∆p Tot. ≤ ∆p max allowed 2 3.13 2.55 1.46 1.22 0.78 0.75 0.64 0.19
3
CU 400 3 2.15 1.70 0.94 0.78 0.50 0.40 0.34 0.10
4 1.60 1.28 0.71 0.61 0.40 0.34 0.27 0.08
0 5 1.00 0.83 0.47 0.34 0.20 0.24 0.19 0.06
Maximum total pressure drop (∆p max) allowed by a new and 0 100 200 300 400 500
6 0.82 0.58 0.30 0.27 0.17 0.22 0.18 0.05
clean filter
Application Range (bar)
Suction filters 0.08 ÷ 0.10 CU 900 1 0.86 0.63 0.32 0.30 0.21 - - 0.05
Return filters 0.4 ÷ 0.6
Return - Suction filters* 0.8 ÷ 1.0
0.4 ÷ 0.6 return lines 2 1.03 0.80 0.59 0.40 0.26 - - 0.05
0.3 ÷ 0.5 lubrication lines CU 950
3 0.44 0.40 0.27 0.18 0.15 - - 0.02
Low & Medium Pressure filters 0.3 ÷ 0.4 off-line in power systems
0.1 ÷ 0.3 off-line in test benches
0.4 ÷ 0.6 over-boost
High Pressure filters 0.8 ÷ 1.5 ∆p Tot. = 0.24 + 0.13 = 0.37 bar
Stainless Steel filters 0.8 ÷ 1.5
The selection is correct because the total pressure drop value is
* The suction flow rate should not exceed 30% of the return flow rate inside the admissible range for low and medium pressure filters.
In case the allowed max total pressure drop is not verified, it is
necessary to repeat the calculation changing the filter length/size.
Generic filter calculation example
Application data:
Off-line filtration in power systems
Pressure Pmax = 50 bar
Flow rate Q = 120 l/min
Viscosity V2 = 46 mm2/s (cSt)
Oil density = 0.86 kg/dm3
Required filtration efficiency = 25 μm with absolute filtration
With bypass valve and 1” SAE 3000 psi/UNC inlet connection
Corrective factor FILTER SIZING
Corrective factor Y to be used for the filter element pressure drop calculation. The values depend to the filter size and length and to the filter media.
Reference oil viscosity 30 mm2/s

Low & Medium pressure filters


Filter Absolute filtration Nominal filtration
element N-W Series N Series

Type A03 A06 A10 A16 A25 P10 P25 M25

1 16.25 15.16 8.75 8.14 5.87 2.86 2.65 0.14


CU 110 2 12.62 10.44 6.11 6.02 4.15 1.60 1.49 0.12
3 8.57 7.95 5.07 4.07 2.40 1.24 1.15 0.11
4 5.76 4.05 2.80 2.36 1.14 0.91 0.85 0.05

1 5.30 4.80 2.00 1.66 1.32 0.56 0.43 0.12


CU 210 2 3.44 2.95 1.24 1.09 0.70 0.42 0.35 0.09
3 2.40 1.70 0.94 0.84 0.54 0.33 0.23 0.05

016 7.95 7.20 3.00 2.49 1.98 0.84 0.65 0.18


DN 025 5.00 4.53 1.89 1.57 1.25 0.53 0.41 0.11
040 3.13 2.66 1.12 0.98 0.63 0.38 0.32 0.08

2 3.13 2.55 1.46 1.22 0.78 0.75 0.64 0.19


CU 400 3 2.15 1.70 0.94 0.78 0.50 0.40 0.34 0.10
4 1.60 1.28 0.71 0.61 0.40 0.34 0.27 0.08
5 1.00 0.83 0.47 0.34 0.20 0.24 0.19 0.06
6 0.82 0.58 0.30 0.27 0.17 0.22 0.18 0.05

CU 900 1 0.86 0.63 0.32 0.30 0.21 - - 0.05

2 1.03 0.80 0.59 0.40 0.26 - - 0.05


CU 950
3 0.44 0.40 0.27 0.18 0.15 - - 0.02

MR 630 7 0.88 0.78 0.36 0.34 0.16 0.12 0.96 0.47


TYPICAL FILTER SIZING Selection Software
Step 1 Select “FILTERS”

Step 2 Choose filter group (Return Filter, Pressure Filter, etc.)

Step 3 Choose filter type (MPF, MPT, etc.) in function of


the max working pressure and the max flow rate

Step 4 Push “PROCEED”

Step 5
Insert all application data to calculate the filter size following the sequence:
- working pressure
- working flow rate
- working pressure drop
- working temperature
- fluid material and fluid type
- filtration media
- connection type

Step 6
Push “CALCULATE” to have result;
in case of any mistake, the system
will advice which parameter is out
of range to allow to modify/adjust
the selection

Step 7
Download PDF
Datasheet “Report.aspx” pushing the button “Drawing”

Introduction 26
TYPICAL FILTER SIZING

27 Introduction
LMP - low and medium pressure filters are used as process
filters to protect pumps, pressure reducers and hydraulic
circuits from damage due to oil contamination as per ISO 4406.

LMP series is available in 5 different sizes: 100, 200, 400, 900 and
950 and a wide range of versions.

LMP filters are available with several working pressures suitable


for all hydraulic circuits as:
- return filters in external tank mounting construction
for medium and high flow rates in single and duplex versions
- in-line filters for low and medium pressures for off-line
applications
- in-line process filters for medium pressures, for example, for
forced lubrication applications, in single or duplex versions
- in-line filters for medium pressures for filtering
hydraulic boost circuits
- in-line filters as high holding capacity filters on test beds

LMP filters are thus specifically designed to be suitable for a wide


range of application: from steel plants to mobile equipments,
from test benches to naval application, providing the right solution
for filtering requirements in all sectors.

LMP filters are available in single, manifold and duplex versions


(LMD series).

FILTER SIZING
For the proper corrective factor Y click here.

Low & Medium Pressure filters 322


Low & Medium Pressure filters

LMP 110 - 120 - 123 MULTIPORT page 325 Filter element according to DIN 24550 page 415
LMP 210 - 211 341 LDP - LDD 417
LMP 400 - 401 & 430 - 431 351 LMP 900 - 901 427
LMP 950 - 951 363 LMP 902 - 903 435
LMP 952 - 953 - 954 371
LMD 211 383
LMD 400 - 401 & 431 391 INDICATORS page 444
LMD 951 407 ACCESSORIES page 450

323 Low & Medium Pressure filters


Low & Medium Pressure filters 324
Low & Medium Pressure filters

LMP 110-120-123 series MULTIPORT


Maximum working pressure up to 8 MPa (80 bar) - Flow rate up to 200 l/min

325 Low & Medium Pressure filters


LMP 110-120-123
MULTIPORT
GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Aluminium
Maximum working pressure up to 8 MPa (80 bar)
- Housing: Cataphoresis - Painted Steel
Flow rate up to 200 l/min - Bypass valve: Brass - Aluminium

LMP110 is a range of versatile low pressure filter for transmission,


protection of sensitive components in low pressure hydraulic systems Pressure
and filtration of the coolant into the machine tools. - Test pressure: 12 MPa (120 bar)
They are directly connected to the lines of the system through the - Burst pressure:
hydraulic fittings. LMP 110: 29 MPa (290 bar)
LMP 120/130: 38 MPa (380 bar)
Available features: - Pulse pressure fatigue test: 1 000 000 cycles
- Female threaded connections up to 1”, for a maximum return with pressure from 0 to 8 MPa (80 bar)
flow rate of 200 l/min
- Fine filtration rating, to get a good cleanliness level into the system
- Bypass valve, to relieve excessive pressure drop across the filter media
Bypass valve
- Visual, electrical and electronic differential clogging indicators - Opening pressure 350 kPa (3.5 bar) ±10%
- Multiport and multifunction schemes, to meet any type of application. - Other opening pressures on request.
- LMP112: 3/4” additional input port
- LMP116: 3/4” additional output port
∆p element type
- LMP118: 3/4” bypass port, to send the bypass flow to the reservoir
instead of the system - Microfibre filter elements - series N - W: 20 bar
- LMP119: 3/4” relief port, to relief the input pressure in the filter, protecting - Wire mesh filter elements - series N: 20 bar
the components downstream the filter against back pressure caused - Fluid flow through the filter element from OUT to IN
by the pressure drop (cold starts)
- LMP120: connections placed in the same side
Seals
- LMP122: connections placed in the same side and 1” additional output port
- LMP123: 2 and 3 bar integrated relief valve - Standard NBR series A
- Optional FPM series V
Common applications:
Delivery lines, in any low pressure industrial equipment or mobile machines Temperature
From -25 °C to +110 °C

Note
LMP MULTIPORT filters
are provided for vertical
mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 1 2 3 4 Length 1 2 3 4
LMP 110-112-116-118-119 1.60 1.80 2.10 2.60 0.75 0.81 1.11 1.53
LMP 120-122 1.90 2.10 2.40 2.90 0.75 0.81 1.11 1.53
LMP 123 1.70 1.90 2.20 2.70 0.75 0.81 1.11 1.53

Low & Medium Pressure filters 326


GENERAL INFORMATION LMP 110-120-123 MULTIPORT

FILTER ASSEMBLY SIZING


Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 M60
A25 P10 P25
M90
M250
1 40 42 65 69 85 163 117 120
2 49 57 83 83 101 163 136 138
LMP 110
3 66 70 92 102 124 164 142 144
4 86 102 118 124 144 165 148 149
1 36 38 55 57 67 105 84 86
2 44 49 66 66 76 105 93 94
LMP 112
3 56 58 71 77 87 106 96 97
4 67 77 85 88 97 106 99 99
1 36 38 54 56 64 96 79 80
2 43 49 63 64 72 96 86 87
LMP 116
3 54 57 68 73 82 96 88 89
4 65 73 79 82 89 96 91 91
1 40 42 65 69 85 163 117 120
2 49 57 83 83 101 163 136 138
LMP 118
3 66 70 92 102 124 164 142 144
4 86 102 118 124 144 165 148 149
1 40 43 66 70 87 172 121 125
2 50 58 85 85 104 172 142 144
LMP 120
3 67 71 94 105 129 173 149 151
4 88 106 122 129 151 174 155 157
1 39 42 64 67 81 146 109 111
2 49 56 80 80 96 146 124 126
LMP 122
3 65 68 88 96 114 146 129 130
4 82 97 110 115 131 147 134 135
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Filter element design - N Series


M25
Filter series Length A03 A06 A10 A16 A25
M60 P10 P25
M90
1 35 37 50 52 59 83 70 71
2 41 46 58 58 65 83 76 76
LMP 123
3 51 53 62 65 72 83 77 78
4 59 65 70 72 78 83 79 79
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 2.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

327 Low & Medium Pressure filters


0.4 1/2”F1 - 3” 3/4” 1” 0.9
A>C

Δp
LMP 901 0.6 0.9
0.6 LMP 901 0.2 F1 - 3” A>B
0.9 0.9
18 9 3/4” 1”
0.2 F1 - 3” 0.6

LMP 110-120-123
1/2” 3/4” 1” 3/4” 1”

0
100
0.3
0.6
MULTIPORT
300 600 900 1200 1500
0.6
12
0
100 300
0.3 600 GENERAL INFORMATION
Flow rate l/min
900 1200 1500
0.3
6
0.6

0 0.3
0 Flow rate l/min
80 120 160 200
3 0 40
Pressure drop
0.3 0 40 80 120 160 200 0.36
0
0 40 80 120 160 200
0
0 00 0 0 40 80 120 160 200
Filter0 housings
40 ∆p pressure
80 drop
120 160 200 00 40
20
Valves 80
40 120
60 160
80 200
100 0 40 80 120 160 200
LMP 110Bypass valve pressure drop LMP 112
0.9 0.9
0.9 OUT OUT
OUT OUT 1/2” 3/4” 1” 0.9
3/4” 1”
0.9
1/2” 3/4” 1” 3/4” 1” 0.99 12 0.9 12 A>C
18
3/4” 1” 0.6 A>C 0.6 1/2” 3/4” 1” A>B
0.6

∆p bar

∆p bar
A>B 0.6
0.9
0.6 1/2” 3/4” 1” PAG0.60.3144
18
6 DEL PDF
8 0.6
0.3
8
A>C
12
0.3
0.3
0.6 12 A>B
0.3 0.33 4 0.3 4 6
0 0
0 80 120 160 200 0 30 60 90 120 150
0.3 0 30 60 90 120 150
0.6 0.9 0- F1 - 3” 40
LMP 900/901
18 0
6
40 0 80 120 160 200 00 0Flow rate
1/2” 3/4”l/min 1” 0 Flow
00 rate40l/min 80 120 160 0 200
0 40 80 120 160 200 00080
80 40
40 120
120
40 160
160
80 200
200
120 160 0 200 40 0
80 40
120 80
160 120
200 160 0 200
PAG 0144 DEL PDF 0.4 0.60 LMP 900
F1 - 3” 12
Valves
Δp bar

0 40 80 120 160 200 Valves 0 40 20 60 80 100


Bypass valve pressure drop
0.9
LMP 116 LMP 118 - 11918 LMP 110 LMP
0.9 pressure - Setting
901 6 bar 0.9 LMP 120 12
0.9 0.3
0.2 Bypass valve
0.9 drop
F1 - 3” 0.9
6
18 IN 9
A>C OUT3/4” 1” OUT 3/4”
LMP 900/901 - F1 -OUT
3”
IN 1/2”
3/4” 1” 12 3/4”1”
- 1” A>C
0.6 OUT 3/4”A>B
- 1”
0.9 9
PAG 144 DEL PDF
0.6
0.6
3/4” 1”
3/4” 1” 0
12
0.6
0
0.6 12 12
0.6
0.6
0
12 8 6
∆p bar

∆p bar

∆p bar
100 300 0 60040 90080 1200120 160
1500 200 0 20 40 60 80 100
LMP 900 8
0.4 0.6 F1 - 3” Flow rate l/min A>C A>B
0.3 86
0.3 6 8
0.3 4
0.3 0.3 0.36 3
LMP 900/901 - F1 - 3” LMP 901 0.9 4
0.2
0.6 0.3 F1 - 3” 9 A>B
00 04 3 0 3/4” 1” 04
00 0 0
0 0 30 60 90 120 150
00 40 80 120 160 200 0 30 060 90
32120 120
64 150
96 128 00160 40 080 40
120 8080
160 120
200 160 0 200
30 60 90 120 150 0 40 80 160 200 20 0 40 60 100
30 60 90 LMP
120 900 150 0.60 6
00.4 0 Flow
F1 - rate
3” l/min Flow rate l/min Flow
0 rate40l/min 80 120 160 200
0 0
100 300 0 600 40 900 80 1200 120 1500 160 200 200
Valves 0.9 00 4040 8080 120
120 160
160 200 0 40 80 120 160 200
Flow rate l/min
Bypass valve pressure drop LMP 901 0.3
0.9 39
0.2 F1 - 3” 1/2” 3/4” 1” 0.9
3/4” 1” LMP 110 - Setting
A>C 6 bar
LMP 122 0.9 LMPLMP110
123- Setting
- Filter6housing with 2 bar check valve 18 housing with 3 bar check valve
LMP 123 - Filter
0.6 bar A>B
0.9
12 18
12 IN 12
0 A>C 00.6 3/4” - 1” 06
0.6
IN 0 40 80 120 160 200 0 40 80 120 160 A>C 200
100 300 600 900 3/4” -1200
1” 1500 A>B 12
0.3 0.6 A>C
0.6
8 Flow rate l/min 128 8
0.3 0.33
∆p bar

∆p bar

0 0.3 ∆p bar 6 A>B


1/2”
0.3 3/4” 1” 0.9 A>B
4 64 200 4
0 40 0 80 120 160 A>C 00
0 40 80 120 160 A>B 200 200
0
00 40
40 0 8080 120
120 160
160 200
0.6 64 96 128 160
00 00 0 30 60 90 120 150 0 0 32
30 0060 4090
40 80
80
120 120
120
150 160
160 200
200 00 32
40 64
80 96
120 128
160 160
200 0 40 80 120 160 200
Valves
1/2” 3/4” Flow1” rate l/min 0.3
0.9 Flow rate l/min Bypass valve pressure drop Flow rate l/min
Valves 0.9 A>C
LMP 110 - Setting 6 bar OUT OUT A>B
Bypass
40 18 80
valve pressure drop
120 160 200 12 3/4” 1” 12 12
00.6
0.6 0 40 80 120 160 A>C 200
12 12
12 8 8 8
0.3
0.3 Valves
A>C
A>B
8 Bypass valve8 pressure drop
40 6 80valve pressure
Bypass 120 160drop 200 4 4 4
0
OUT OUT 0 0LMP 11040
- 112 - 116
80 - 118 - 120
119 - Setting
160 3.5 bar
200 LMP 118 - Setting 3.5 bar
3/4” 1” 0.9
12 4 60 A>B 12
18
4 0 30 90 120 150
0 1/2” 3/4” 1”
0.9 180 0 0
0 32
1/2” 64
3/4” 96 1” 128 160 0 40 80 120 160 200 0 40 80 120 160 A>C 200 0
PAG 144
0
DEL PDF Valves
0.68 0
Bypass valve pressure drop
128
∆p bar

∆p bar

0.6 0 40 80 120 160 200 12 0 40 80 120 160 200


OUT OUT LMP 110 - Setting 6 bar
3/4” 1” 0.3
4 184
612 A>B 12
0.9 12
LMP 900/901 - LMP
F1 - 3” IN
0.6 0.3 30 110 - Setting 6 bar 612 3/4” - 1”
18 60 90 120 150
0 08 008
12 A>C
0.6 8
00 40
40 80
80 120
120 160 A>C 200
160 200 00 40
20 80
40 120
60 160
80 200
100
LMP 900
0.4 12 F1 - 3” Flow rate l/min Flow rate l/min
0 08 64 A>B 4
0.3 4
0 40 80 120 160 200 0 20 40 60 80 100
LMP 901 0.9 LMP 110 - Setting 6 bar A>B
0.2 6 60 F1 -150
3” 18 4 9
12
30 90 120 3/4” 1”
IN 0 0 00 0
3/4” - 1” A>C
0 30 0LMP 40
60 120 - 90 80
122 - Setting 120
120 3.5 bar
150 160 200 00 32
40 64
80 96
120 128
160 160
200 0
0 0.9 0.6
12
90 68
0
100 300 0 600 32 900 64 1200
3/4” 96 15001”
128 160 0 40 80 120 160 200
Flow rate l/min A>B
0.3 LMP 110 - Setting 6 bar 312
6
18 4
0.6 6
IN
∆p bar

3/4” - 1” A>C
012
0 008
0.3 30 60 90 120 150 3 00 40
32 80
64 120
96 160
128 200
160 0 40
40 80
80 120
120 160
160 200
200
A>B
6 4
0 0
0.9
1/2” 3/4” 1”
0 40 80 120 160 200 00 40 80 120
A>C 160 200 0
30 60 90 120 150 0 32 64Flow rate
96 l/min 128 A>B 160 0 40 80 120 160 200
0.6

0.9 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.
The curves are plotted using mineral oil with density of 0.3
A>C
A>B
0.6 40 80 120 160 200 0
0 40 80 120 160 200

0.3 Low & Medium Pressure filters 328 Valves


Bypass valve pressure drop
GENERAL INFORMATION LMP 110-120-123 MULTIPORT

Hydraulic symbols - Multiport styles

LMP 110 In-Line filter LMP 120 Port IN-OUT on the same side

OUT

D.I.
D.I. D.I.

OUT IN
IN

LMP 112 Double IN port LMP 122 Lateral OUT port high flow

OUT

OUT

D.I. D.I.
D.I.

IN2

IN1 IN

LMP 116 Double OUT port LMP 123 Bypass valve


Type 1 for heat exchanger high flow
OUT
OUT2

OUT2

D.I.
D.I. D.I.

OUT1 IN
IN

LMP 118 Bypass lateral


Always cleaning fluid in OUT port
Type 2
OUT1 OUT2

D.I.
D.I.

OUT2
OUT1 IN

IN

LMP 119 Safety valve 6 bar


for heat exchanger

OUT1

D.I.

OUT2

IN

329 Low & Medium Pressure filters


LMP
MULTIPORT
LMP110 - LMP112 - LMP116
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP112 4 B A D 1 A10 N P01
LMP110 LMP112 LMP116
Length
1 2 3 4
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
Aux (only LMP 112 - 116)
A G 3/4” G 3/4”
B G 1” G 3/4”
C 3/4” NPT 3/4” NPT
D 1” NPT 3/4” NPT
E SAE 12 - 1 1/16” - 12 UN SAE 12 - 1 1/16” - 12 UN
F SAE 16 - 1 5/16” - 12 UN SAE 12 - 1 1/16” - 12 UN
Connection for differential indicator
1 Without
2 With standard connection
3 With connection on the opposite side
6 With two connections on both sides
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU110 4 A10 A N P01
CU110
Element length
1 2 3 4
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized
ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 330


LMP110 - LMP112 - LMP116 LMP
MULTIPORT

Dimensions
LMP110 - LMP112
LMP116
Filter H
length [mm]
1 182
2 215
3 265
4 365

IN OUT

Recommended
clearance space
for maintenance
2 - Standard connection for
differential indicator 35.1
T2 plug not included

Fixing holes
Option for Metric and UNC screws

3/8 UNC x depth 12


Nr. 4 holes
3 - Connection for M10 x depth 12
differential indicator Nr. 3 holes
60.6 on the opposite side
T2 plug not included

LMP 110 LMP 112 LMP 116

Aux Aux
IN OUT

331 Low & Medium Pressure filters


LMP
MULTIPORT
LMP118 - LMP119
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP118 4 B A D 1 A10 N P01
LMP118 LMP119
Length
1 2 3 4
Bypass valve
B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
Aux OUT
A G 3/4” G 3/4”
B G 1” G 3/4”
C 3/4” NPT 3/4” NPT
D 1” NPT 3/4” NPT
E SAE 12 - 1 1/16” - 12 UN SAE 12 - 1 1/16” - 12 UN
F SAE 16 - 1 5/16” - 12 UN SAE 12 - 1 1/16” - 12 UN
Connection for differential indicator
1 Without
2 With standard connection
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU110 4 A10 A N P01
CU110
Element length
1 2 3 4
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 332


LMP118 - LMP119 LMP
MULTIPORT

Dimensions
LMP118 - LMP119
Filter H
length [mm]
1 182
2 215
3 265
4 365

IN OUT

Recommended
clearance space
for maintenance
Connection for
differential indicator 35.1
T2 plug not included

Fixing holes
Option for Metric and UNC screws

3/8 UNC x depth 12


Nr. 4 holes

M10 x depth 12
60.6 Nr. 3 holes

Aux
OUT

333 Low & Medium Pressure filters


LMP
MULTIPORT
LMP120 - LMP122
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP120 4 B A D 1 A10 N P01
LMP120 LMP122
Length
1 2 3 4
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections LMP120 LMP122
A G 3/4” •
B G 1” • •
C 3/4” NPT •
D 1” NPT • •
E SAE 12 - 1 1/16” - 12 UN •
F SAE 16 - 1 5/16” - 12 UN • •

Connection for differential indicator


1 Without
2 With standard connection

Filtration rating (filter media)


A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU110 4 A10 A N P01
CU110
Element length
1 2 3 4
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 334


LMP120 - LMP122 LMP
MULTIPORT

Dimensions
LMP120
Filter H
length [mm]
1 182
2 215
3 265
4 365

Connections R
A-B M10
C-D-E-F 3/8” UNC

Recommended
clearance space
for maintenance
R - depth 12 mm
Connection for Nr. 3 holes
differential indicator
T2 plug not included

OUT IN

LMP122
Filter H
length [mm]
1 182
2 215
3 265
4 365

Connections R
B M10
D-F 3/8” UNC

Recommended
clearance space
for maintenance
Connection for R - depth 12 mm
differential indicator Nr. 3 holes
T2 plug not included

OUT

Plug not included


IN

335 Low & Medium Pressure filters


LMP
MULTIPORT
LMP123
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP123 4 R A F 1 A10 N P01
LMP123
Length
1 2 3 4
Valves Bypass OUT to cooler Check valve
C front 2 bar
D 3 bar
without
G side 2 bar
H 3 bar
M front 2 bar
N 3 bar
3.5 bar
Q side 2 bar
R 3 bar

Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
B G 1”
F SAE 16 - 1 5/16” - 12 UN

Connection for differential indicator


1 Without
2 With standard connection

Filtration rating (filter media)


A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm Element ∆p Execution
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm N 20 bar P01 MP Filtri standard
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU110 4 A10 A N P01
CU110
Element length
1 2 3 4
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized
ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 336


LMP123 LMP
MULTIPORT

Dimensions
LMP123
Filter H
length [mm]
1 182
2 215
3 265
4 365

Connections R
B M10
F 3/8” UNC

Recommended
clearance space
for maintenance
Connection for R - depth 12 mm
differential indicator Nr. 3 holes
T2 plug not included

Side
OUT

Front IN
OUT

337 Low & Medium Pressure filters


LMP 110-120
MULTIPORT
SPARE PARTS
Order number for spare parts
LMP 110 - 112 - 116 - 118 - 119 LMP 120 LMP 122 - 123

4 3c 3d
3d 3c 4

3d 3c 4

3a
3a 3a

3b
3b 3b

2
2 2

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc.


Item: 2 3 (3a ÷ 3d) 4
Filter Filter Seal Kit code number Indicator connection plug
series element NBR FPM NBR FPM
LMP 110-112-116 -118-119 See
LMP 120 order 02050478 02050479 T2H T2V
table
LMP 122-123

Low & Medium Pressure filters 338


LMP 110-120 MULTIPORT

339 Low & Medium Pressure filters


Low & Medium Pressure filters 340
Low & Medium Pressure filters

LMP 210-211
Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

341 Low & Medium Pressure filters


LMP 210-211 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Aluminium
Maximum working pressure up to 6 MPa (60 bar)
- Bowl: Cataphoretic Painted Steel
Flow rate up to 330 l/min - Bypass valve: AISI 304 - Nylon

LMP210 is a range of versatile low pressure filter for transmission,


protection of sensitive components in low pressure hydraulic systems
Pressure
and filtration of the coolant into the machine tools. - Test pressure: 9 MPa (90 bar)
They are also suitable for the off-line filtration of small reservoirs. - Burst pressure: 21 MPa (210 bar)
They are directly connected to the lines of the system through the - Pulse pressure fatigue test: 1 000 000 cycles
hydraulic fittings. with pressure from 0 to 6 MPa (60 bar)

Available features: Bypass valve


- Flanged connections up to 1 1/2”, for a maximum flow rate of 330 l/min - Opening pressure 350 kPa (3.5 bar) ±10%
(LMP210) - Other opening pressures on request.
- Female threaded connections up to 1 1/2”, for a maximum return
flow rate of 330 l/min (LMP211)
- Fine filtration rating, to get a good cleanliness level into the system ∆p element type
- Water removal elements, to remove the free water from the hydraulic fluid. - Microfibre filter elements - series N: 20 bar
For further information, see the Contamination Management document - Fluid flow through the filter element from OUT to IN
and the dedicate leaflet.
- Bypass valve, to relieve excessive pressure drop across the filter media
- Visual, electrical and electronic differential clogging indicators Seals
- Standard NBR series A
Common applications: - Optional FPM series V
Delivery lines, in any low pressure industrial equipment or mobile machines

Temperature
From -25 °C to +110 °C

Connections
Inlet/Outlet In-Line

Note
LMP 210 - 211 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 1 2 3 Length 1 2 3
LMP 210-211 3.10 4.80 6.40 1.60 2.10 2.80

Low & Medium Pressure filters 342


GENERAL INFORMATION LMP 210-211
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
Filter series Length A03 A06 A10 A16 A25 M25 M60 M90 M250 P10 P25
1 106 130 190 200 221 286 287 287 288 261 265
LMP 210 2 153 175 220 237 249 288 289 290 290 265 269
3 204 214 248 260 265 289 290 291 291 277 281

1 118 149 227 240 269 358 359 360 361 324 330
LMP 211 2 178 207 268 292 307 361 362 363 364 329 335
3 247 260 306 323 329 362 363 364 365 345 351
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S Execution B
LMP 210-211 • •
LMP 210 Δp
0.9
1” OUT 1 1/4” 1 1/2” OUT

LMP 210 Δp
0.6 0.9
1” 1 1/4” 1 1/2”
D.I. D.I.

0.3 0.6

IN IN
0.3
0
0 80 160 240 320 400

0
0 80 160 240 320 400
Pressure drop
LMP 211 Δp
0.9
Filter housings ∆p pressure drop
LMP 210 Δp Housing 1” 1 1/4” 1 1/2” LMP 211 Δp Housing
0.9 0.9
0.6
1” 1 1/4” 1 1/2”
1” 1 1/4” 1 1/2”
0.6
0.3 0.6
∆p bar

∆p bar

0.3 0.3
0
0 80 160 240 320 400

0 0
0 80 160 240 320 400 0 80 160 240 320 400
Valves
Flow rate l/min Flow rate l/min
Bypass valve pressure drop
Valves
Bypass valve pressure drop
LMP
LMP 211 Δp
210/211 Bypass valve pressure drop
90.9

1” 1 1/4” 1 1/2” LMP 210/211


60.6 9
∆p bar

30.3 6

00 3
00 80
100 160
200 240
300 320
400 400
500
Flow rate l/min
0
Valves
0 100 200 300 400 500
The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.
Bypass valve pressure drop

LMP 210/211
9

6
343 Low & Medium Pressure filters

3
LMP 210
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP210 3 B A F1 A10 N P01
LMP210
Length
1 2 3
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
F1 1” SAE 3000 psi/M
F2 1 1/4” SAE 3000 psi/M
F3 1 1/2” SAE 3000 psi/M
F4 1” SAE 3000 psi/UNC
F5 1 1/4” SAE 3000 psi/UNC
F6 1 1/2” SAE 3000 psi/UNC
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series and size Configuration example: CU210 3 A10 A N P01
CU210
Element length
1 2 3
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm


Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 344


LMP 210
Dimensions
LMP210
Filter H
length [mm]
1 362
2 492
IN OUT
3 633

Connections R
F1 - F2 - F3 M8
F4 - F5 - F6 5/16” UNC

A/F 30
Drain plug only length 3
Recommended
clearance space
for maintenance
Connection for
differential indicator
T2 plug

R - depth 12 mm
Nr. 4 holes

345 Low & Medium Pressure filters


LMP 211
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP211 3 B A D 6 A10 N P01
LMP211
Length
1 2 3
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
A G 1”
B G 1 1/4”
C G 1 1/2”
D 1” NPT
E 1 1/4” NPT
F 1 1/2” NPT
G SAE 16 - 1 5/16” - 12 UN
H SAE 20 - 1 5/8” - 12 UN
I SAE 24 - 1 7/8” - 12 UN
Connection for differential indicator
6 With plugged connection
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series and size Configuration example: CU210 3 A10 A N P01
CU210
Element length
1 2 3
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • • Element ∆p Execution
W NBR compatible with fluids HFA-HFB-HFC • • N 20 bar P01 MP Filtri standard
Pxx Customized
ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 346


LMP 211
Dimensions
LMP211
Filter H
length [mm]
1 358
2 488
IN OUT 3 629

Connections R
A-B-C M8
D-E-F-G-H-I 5/16” UNC

A/F 30
Drain plug only length 3
Recommended
clearance space
for maintenance
Connection for
differential indicator
T2 plug

R - depth 12 mm
Nr. 4 holes

347 Low & Medium Pressure filters


LMP 210-211 SPARE PARTS
Order number for spare parts
LMP 210 LMP 211

4 4

3c 3c

3d 3d

3a 3a

3b 3b

2 2

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc.


Item: 2 3 (3a ÷ 3d) 4
Filter Filter Seal Kit code number Indicator connection plug
series element NBR FPM NBR FPM
See
LMP 210-211 order 02050435 02050436 T2H T2V
table

Low & Medium Pressure filters 348


LMP 210-211

349 Low & Medium Pressure filters


Low & Medium Pressure filters 350
Low & Medium Pressure filters

LMP 400-401 & 430-431 series


Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 740 l/min

351 Low & Medium Pressure filters


LMP 400-401 & 430-431 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Maximum working pressure up to 6 MPa (60 bar)
- Housing: Anodized Aluminium
Flow rate up to 740 l/min - Bypass valve: Steel

LMP400 is a range of low pressure filter with large filtration surface Pressure LMP 400 length 2 -3 - 4
mainly suitable for lubrication, off-line filtration of the reservoirs and - Working pressure: 6 MPa (60 bar)
filtration equipment. - Test pressure: 9 MPa (90 bar)
They are directly connected to the lines of the system through the - Burst pressure: 21 MPa (210 bar)
hydraulic fittings. - Pulse pressure fatigue test: 1 000 000 cycles
with pressure from 0 to 6 MPa (60 bar)
Available features:
- Female threaded connections up to 2” and flanged connections up to 2 1/2”, Pressure LMP 400 length 5 - 6
for a maximum flow rate of 740 l/min - Working pressure: 5 MPa (50 bar)
- In line or 90° connections, to meet any type of application - Test pressure: 7.5 MPa (75 bar)
- Base-mounting design also available, for ease of the replacement of - Burst pressure: 15 MPa (150 bar)
the filter element - Pulse pressure fatigue test: 1 000 000 cycles
- Fine filtration rating, to get a good cleanliness level into the system with pressure from 0 to 5 MPa (50 bar)
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document Bypass valve
and the dedicate leaflet. - Opening pressure 350 kPa (3.5 bar) ±10%
- Bypass valve, to relieve excessive pressure drop across the filter media - Other opening pressures on request.
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work ∆p element type
- Visual, electrical and electronic differential clogging indicators - Microfibre filter elements - series N - W: 20 bar
- Fluid flow through the filter element from OUT to IN
Common applications:
- Off-line filtration of reservoirs Seals
- Filtration systems - Standard NBR series A
- Optional FPM series V

Temperature
From -25 °C to +110 °C

Connections
LMP 400 - 430: In-line Inlet/Outlet
LMP 401 - 431: 90° Inlet/Outlet

Note
LMP 400 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 2 3 4 5 6 Length 2 3 4 5 6
LMP 400-401 & 430-431 7.20 8.10 8.80 11.90 14.40 3.50 5.00 6.50 9.50 13.50

Low & Medium Pressure filters 352


GENERAL INFORMATION LMP 400-401 & 430-431
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 M60
A25 P10 P25
M90
M250
2 205 244 370 411 515 720 524 556
3 280 333 474 515 602 760 637 660
LMP 400 4 347 400 535 564 637 769 660 688
5 459 501 610 660 717 781 700 721
6 504 575 676 689 728 783 708 727

2 200 236 347 382 468 628 475 501


3 268 315 434 468 537 659 565 582
LMP 401 4 328 373 484 507 565 665 582 603
5 423 456 544 582 626 674 613 629
6 459 516 594 604 634 676 619 633

5 459 501 610 660 717 781 700 721


LMP 430
6 504 575 676 689 728 783 708 727

5 423 456 544 582 626 674 613 629


LMP 431
6 459 516 594 604 634 676 619 633
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

LMP 430-431: execution P02 Hydraulic symbols


Filter series Execution S Execution B
LMP 400-401 & 430-431 • •

OUT OUT

“Internal tube
for reduced flow rate” D.I. D.I.
is recommended
for flow rate values LMP 400 - 401 - 430 - 431
0.9
below 100/150 I/min. IN IN

G1
The use of option P02 0.6 G2 - F1
makes it easier to fill F2
the housing with the
operating fluid. 0.3

0
0 180 360 540 720 900

Valves
Bypass valve pressure drop Pressure drop
Filter housings Bypass valve
LMP 400 - 401 - 430 - 431 LMP 400 - 401 - 430 - 431
0.9 ∆p pressure drop 9 pressure drop
G1
0.6 G2 - F1 6
∆p bar

∆p bar

F2

0.3 3

0 0
0 180 360 540 720 900 0 140 280 420 560 700
Flow rate l/min Flow rate l/min

Valves
The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.
Bypass valve pressure drop

LMP 400 - 401 - 430 - 431


9 353 Low & Medium Pressure filters
LMP 400-401
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP401 3 B A G1 A10 N P01
LMP400 LMP401
Length
2 3 4 5 6
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
G1 G 1 1/2” F1 2” SAE 3000 psi/M
G2 G 2” F2 2 1/2” SAE 3000 psi/M
G3 1 1/2” NPT F3 2” SAE 3000 psi/UNC
G4 2” NPT F4 2 1/2” SAE 3000 psi/UNC
G5 SAE 24 - 1 7/8” - 12 UN
G6 SAE 32 - 2 1/2” - 12 UN
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Filter length
Element ∆p Execution 2 3 4 5 6
N 20 bar P01 MP Filtri standard • • • • •
P02 Maintenance from the bottom of the housing • •
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU400 3 A10 A N P01
CU400
Element length
2 3 4 5 6
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 354


LMP 400-401
Dimensions
LMP400
Length 2 - 3 - 4
Filter H
length [mm]
OUT IN 2 378
3 478
4 578

Connections R
G1-G2 M12
G3-G4-G5-G6 1/2” UNC
F1-F2 M12
F3-F4 1/2” UNC

Drain plug Recommended


clearance space
for maintenance
Breather plug
T2 plug R - depth 20 mm
Nr. 4 holes

T2 plug =
connection for differential indicator

Breather plug
T2 plug
Bypass valve

LMP400
Length 5 - 6
H2 [mm]
Filter H Execution
OUT IN length [mm] P01 P02
5 828 120 660
6 1158 120 690

Connections R
G1-G2 M12
G3-G4-G5-G6 1/2” UNC
F1-F2 M12
F3-F4 1/2” UNC

Drain plug H2 - Recommended


clearance space
Breather plug for maintenance
T2 plug R - depth 20 mm
Nr. 4 holes

T2 plug =
connection for differential indicator

Breather plug
T2 plug
Bypass valve

355 Low & Medium Pressure filters


LMP 400-401
Dimensions
LMP401
R - depth 20 mm
Nr. 4 holes Length 2 - 3 - 4
OUT
Filter H
length [mm]
2 378
IN 3 478
4 578

Connections R
G1-G2 M12
G3-G4-G5-G6 1/2” UNC
F1-F2 M12
F3-F4 1/2” UNC

Drain plug Recommended


clearance space
for maintenance
T2 plug Breather plug

T2 plug =
connection for differential indicator

Breather plug
T2 plug
Bypass valve

LMP401
R - depth 20 mm
Nr. 4 holes Length 5 - 6
OUT H2 [mm]
Filter H Execution
length [mm] P01 P02
IN 5 828 120 660
6 1158 120 690

Connections R
G1-G2 M12
G3-G4-G5-G6 1/2” UNC
F1-F2 M12
F3-F4 1/2” UNC

Drain plug H2 - Recommended


clearance space
T2 plug Breather plug for maintenance

T2 plug =
connection for differential indicator

Breather plug
T2 plug
Bypass valve

Low & Medium Pressure filters 356


LMP 400-401

357 Low & Medium Pressure filters


LMP 430-431
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP431 5 B A G1 A10 N P01
LMP430 LMP431
Length
5 6
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
G1 G 1 1/2” F1 2” SAE 3000 psi/M
G2 G 2” F2 2 1/2” SAE 3000 psi/M
G3 1 1/2” NPT F3 2” SAE 3000 psi/UNC
G4 2” NPT F4 2 1/2” SAE 3000 psi/UNC
G5 SAE 24 - 1 7/8” - 12 UN
G6 SAE 32 - 2 1/2” - 12 UN
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm Element ∆p Execution
N 20 bar P01 MP Filtri standard
WA025 Water absorber inorganic microfiber 25 µm P02 With internal tube for reduced flow rate
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU400 5 A10 A N P01
CU400
Element length
5 6
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 358


LMP 430-431
Dimensions
Drain plug LMP430
T2 plug
R - depth 20 mm Filter H H2
Nr. 4 holes length [mm] [mm]
5 828 660
T2 plug =
6 1158 690
connection for differential indicator
Connections R
G1-G2 M12
Drain plug G3-G4-G5-G6 1/2” UNC
T2 plug H2 - Recommended
clearance space F1-F2 M12
for maintenance F3-F4 1/2” UNC
Breather plug

OUT IN

T2 plug Drain plug


LMP431
Filter H H2
length [mm] [mm]
5 828 660
T2 plug = 6 1158 690
connection for differential indicator

Connections R
G1-G2 M12
Drain plug
T2 plug H2 - Recommended G3-G4-G5-G6 1/2” UNC
clearance space F1-F2 M12
for maintenance
Breather plug F3-F4 1/2” UNC

IN

R - depth 20 mm
OUT Nr. 4 holes

359 Low & Medium Pressure filters


LMP 400-401 & 430-431 SPARE PARTS
Order number for spare parts
LMP 400 - 401
length 2 - 3 - 4

4 3c 3d

3e 3d

3f 3c

3a

3b

LMP 400 - 401 LMP 430 - 431


length 5 - 6 length 5 - 6
2

4 3c 3d
3f

3e 3d

3b
3f 3c

5
3g

3a
3a

3b 2

2 3a

3b
3a

6 4

5
3c

3d
3b

3g

3g 4 3c 3d

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 2 pcs. Q.ty: 2 pcs. Q.ty: 1 pc.
Item: 2 3 (3a ÷ 3g) 4 5 6
Filter Filter Seal Kit code number Indicator connection plug Housing spigot Tube
series element NBR FPM NBR FPM no bypass with bypass assembly
LMP 400-401 length 2-3-4 See 02050391 02050392
LMP 400-401 length 5-6 order 02050393 02050394 T2H T2V 01044108
LMP 430-431 length 5-6 table 02050393 02050394 01044108 02001414 Length 5: 02025041 Length 6: 02025042

Low & Medium Pressure filters 360


LMP 400-401 & 430-431

361 Low & Medium Pressure filters


Low & Medium Pressure filters 362
Low & Medium Pressure filters

LMP 950-951 series


Maximum working pressure up to 3 MPa (30 bar) - Flow rate up to 2400 l/min

363 Low & Medium Pressure filters


LMP 950-951 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Maximum working pressure up to 3 MPa (30 bar)
- Housing: Anodized Aluminium
Flow rate up to 2400 l/min - Bypass valve: Anodized Aluminium

LMP950 is a range of low pressure filter with large filtration surface Pressure
mainly suitable for lubrication, off-line filtration of the reservoirs and
- Test pressure: 4,5 MPa (45 bar)
filtration equipment.
- Burst pressure: 12 MPa (120 bar)
They are directly connected to the lines of the system through the
- Pulse pressure fatigue test: 1 000 000 cycles
hydraulic fittings.
with pressure from 0 to 3 MPa (30 bar)
Available features:
- Flanged connections up to 4”, for a maximum flow rate of 2400 l/min Bypass valve
- In line or 90° connections, to meet any type of application - Opening pressure 350 kPa (3.5 bar) ±10%
- Base-mounting design, for ease of the replacement of the filter element - Other opening pressures on request.
- Fine filtration rating, to get a good cleanliness level into the system
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document ∆p element type
and the dedicate leaflet. - Microfibre filter elements - series N: 20 bar
- Bypass valve, to relieve excessive pressure drop across the filter media - Fluid flow through the filter element from OUT to IN
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work
Seals
- Visual, electrical and electronic differential clogging indicators
- Standard NBR series A
- Optional FPM series V
Common applications:
- Off-line filtration of reservoirs
- Filtration systems Temperature
- Lubrication systems From -25 °C to +110 °C

Connections
LMP 950: In-line Inlet/Outlet
LMP 951: 90° Inlet/Outlet

Note
LMP 950 - 951 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 2 3 Length 2 3
LMP 950-951 25.1 33.5 15 28

Low & Medium Pressure filters 364


GENERAL INFORMATION LMP 950-951
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 A25 M60
M90
M250
2 613 756 953 1219 1515 2170
LMP 950
3 1148 1219 1502 1713 1808 2293
2 635 789 1007 1308 1649 2420
LMP 951 3 1226 1308 1634 1881 1993 2566
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

LMP Execution P02 LMP


Filter series Execution S
Hydraulic symbols
Execution B

950 - 951 LMP 952 - 954


LMP 950-951 • •
LMP
Valves
Bypass valve pressure d

950 - 951 952 - 9


OUT OUT

“Internal tube LMP 952


for reduced flow rate” 6
LMP 950 - 951 - F1 - 3” is recommended
D.I. D.I.
LMP 952
0.6 0.36
for flow rate values
4
below 100/150 I/min.
LMP 950 IN IN
0.4 F1 - 3” 0.24
The use of option P02 LMP 950 - 951 - F1 - 3” LMP 9522
LMP 951 0.6 0.36
F1 - 3”
makes it easier to fill
0.12

LMP LMP
0.2 the housing with the LMP 950
0.24 0
operating fluid. 0.4 F1 - 3”
0 4
LMP 951
0 0 F1 - 3”

950 - 951 952 - 954


100 350 700 1050 1400 1750 0 600 1200 1800 2400 3000
0.2 0.12
Pressure drop of filter co
Valves
oil viscosity 30 mm 2 /
0 0 Bypass valve pressure d
LMP 950 - 951 - F3 - 4” 0 600 12
0.6 100 350 700 1050 1400 1750
LMP 953 LMP 952
LMP 950 0.36 Pressure drop 0.6 LMP 952
6
F3 - 4”
0.4 LMP 952 Filter housings ∆p pressure drop
LMP 950 - 951 - F1 - 3” LMP 951 LMP 950 - 951
0.36- F3 - 4”
0.6 0.6 0.4
F3 - 4” 0.24 4
LMP 953
0.2 LMP 950 LMP 950 0.36
F1 - 3” 0.24 F3 - 4” 0.2
0.4 0.4 0.12 2
∆p bar

∆p bar

LMP 951 LMP 951


0 F1 - 3” F3 - 4” 0.24
100 500 1000 1500 2000 2500 0.12
0.2 0.2 0 0
0 0 6
0 600 1200 1800 2400 3000 0 4
0.12
0 0 0
100 350 700 1050 1400 1750 100 500 0 1000 600 1500 1200
2000 18002500 2400 3000
Valves 0
Flow rate l/min Flow rate l/min Pressure drop of filter co
Bypass valve pressure drop 0 600 12
oil viscosity 30 mm 2 /

LMP 950 - 951 - F3 - 4” LMP 954 LMP 953


0.6 LMP 950 - 951 0.36 Bypass valve pressure drop
0.6
6 Valves LMP 952
LMP 953 0.6
LMP 950 Bypass valve pressure drop 0.36
F3 - 4” 0.24 0.4
0.4
4 LMP 951 LMP 954
0.36 0.4
F3 - 4” LMP 950 - 951
0.24
∆p bar

6
0.2 0.12 0.2
2 0.24
0.12 0.2
4
0 0 0
0 100 500 1000 1500 2000 2500 0 600 1200 1800 2400 3000 0 6
0.12 0
0 400 800 1200 1600 2000 0
2 0 600 1200 1800 2400 3000 0 6
Flow rate l/min
0
The curves are plotted using mineral oil with density of 0.86 kg/dm0 3 in compliance with ISO 3968. ∆p varies proportionally with density. 0 600 12
Valves
0 400 800 1200 1600 2000
Bypass valve pressure drop
365 Low & Medium Pressure filters LMP 954
LMP 954 0.6 LMP 953
0.36 0.6
LMP 950 - 951
LMP 950-951
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP951 2 B A F2 A10 N P01
LMP950 LMP951
Length
2 3
Bypass valve
S Without bypass B 3.5 bar

Seals and treatments


A NBR
V FPM
Connections
F1 3” SAE 3000 psi/M
F2 3” SAE 3000 psi/UNC
F3 4” SAE 3000 psi/M
F4 4” SAE 3000 psi/UNC

Filtration rating (filter media)


A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Element ∆p Execution
N 20 bar P01 MP Filtri standard
P02 With internal tube for reduced flow rate
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU950 2 A10 A N P01
CU950
Element length
2 3
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Seals
A NBR
V FPM
Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page page


T2 Plug 449 CFA Retaining clamp 450

Low & Medium Pressure filters 366


LMP 950-951
Dimensions

Drain plug LMP950


T2 plug
R - depth 25 mm Filter H H2
Nr. 4 holes length [mm] [mm]
2 680 350
T2 plug =
connection for differential indicator 3 1230 900

Connections R
F1 - F3 M16
Drain plug F2 - F4 5/8” UNC
T2 plug H2 - Recommended
clearance space
for maintenance
Breather plug

OUT IN

T2 plug Drain plug


LMP951
Filter H H2
length [mm] [mm]
T2 plug = 2 680 350
connection for differential indicator 3 1230 900

Connections R
Drain plug H2 - Recommended
F1 - F3 M16
T2 plug
clearance space F2 - F4 5/8” UNC
for maintenance
Breather plug

IN

R - depth 25 mm
OUT Nr. 4 holes

367 Low & Medium Pressure filters


LMP 950-951 SPARE PARTS
Order number for spare parts
LMP 950 - 951

3f

3b

3a

3a
6

4
3b

3c

3d

3g

4 3c 3d

Q.ty: 2 pcs. Q.ty: 1 pc. Q.ty: 2 pcs. Q.ty: 1 pc. Q.ty: 1 pc.
Item: 2 3 (3a ÷ 3g) 4 5 6
Filter Filter Seal Kit code number Indicator connection plug Housing spigot Tube assembly
series element NBR FPM NBR FPM no bypass with bypass length 2 length 3
See
LMP 950-951 length 2-3 order 02050367 02050368 T2H T2V 01044106 02001379 02025032 02025033
table

Low & Medium Pressure filters 368


LMP 950-951

369 Low & Medium Pressure filters


Low & Medium Pressure filters 370
Low & Medium Pressure filters

LMP 952-953-954 series


Maximum working pressure up to 2.5 MPa (25 bar) - Flow rate up to 3000 l/min

371 Low & Medium Pressure filters


LMP 952-953-954 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Maximum working pressure up to 2.5 MPa (25 bar)
- Housing: Anodized Aluminium
Flow rate up to 3000 l/min - Manifolds: Welded - Phosphatized Steel
- Bypass valve: Anodized Aluminium
LMP952, LMP953 and LMP954 are ranges of low pressure filter with
large filtration surface mainly suitable for lubrication, off-line filtration of Pressure
the reservoirs and filtration equipment. Test pressure: 3.5 MPa (35 bar)
Multiple LMP950 filters are connected to a manifold to reduce the
pressure drop caused by the filter media and to increase the life time of
Bypass valve
the filter element.
- Opening pressure 350 kPa (3.5 bar) ±10%
They are directly connected to the lines of the system through the
- Other opening pressures on request.
hydraulic fittings.

Available features: ∆p element type


- 4” flanged connections, for a maximum flow rate of 3000 l/min - Microfibre filter elements - series N: 20 bar
- Base-mounting design, for ease of the replacement of the filter element - Fluid flow through the filter element from OUT to IN
- Fine filtration rating, to get a good cleanliness level into the system
- Water removal elements, to remove the free water from the hydraulic fluid. Number of filter elements
For further information, see the Contamination Management document - LMP 952: 2 filter elements CU950-3
and the dedicate leaflet. - LMP 953: 3 filter elements CU950-3
- Bypass valve, to relieve excessive pressure drop across the filter media - LMP 954: 4 filter elements CU950-3
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work
Seals
- Visual, electrical and electronic differential clogging indicators
- Standard NBR series A
- Optional FPM series V
Common applications:
- Off-line filtration of reservoirs
- Filtration systems Temperature
From -25 °C to +110 °C

Connections
LMP 952-953-954:
In-line Inlet/Outlet

Note
LMP 952 - 953 - 954 filters
are provided for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 3 Length 3
LMP 952 96 66
LMP 953 138 99
LMP 954 192 132

Low & Medium Pressure filters 372


GENERAL INFORMATION LMP 952-953-954
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 A25 M60
M90
M250
LMP 952 3 2172 2294 2766 3106 3256 3998
LMP 953 3 2842 2964 3403 3696 3820 4395
LMP 954 3 3259 3372 3770 4026 4133 4618
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S - Execution B Execution S - Execution B Execution S - Execution B
LMP 952 •
LMP 953 •
LMP 954 •

S OUT
S OUT
S OUT

D.I. D.I. D.I.

IN IN IN

B OUT
B OUT
B OUT

D.I. D.I. D.I.

IN IN IN

373 Low & Medium Pressure filters


1 952
LMP- 954 F1 - 3”

LMP
LMP 951
Valves0.12
0.2 F1 - 3”

1 952 - 954
Bypass0.12
valve pressure drop
0.2

51 LMP 952-953-954
952 - 954 0
0 100
100
0.36
350
350952
LMP
700
700
1050
1050
1400
1400
1750
1750
Valves0

GENERAL INFORMATION 06 0
LMP 952 - 954
600
Bypass valve pressure drop
0
Valves 600
1200
1200
1800
1800
2400
2400
3000
3000
Pressu
Bypass valve pressure drop oil visc
Pressu
Pressure drop LMP 950 - 951 - F3 - 4”
4
6
LMP 952 - 954
oil vis
P 950 0.6 LMP 952 - 954
1 - 3” 0.24 LMP
LMP 950 952- F3 - 4”
- 951
Filter housings ∆p pressure drop 0.36
0.6 2 LMP6953
LMP 951 0.364
F1 - 3” LMP 952 LMP 950
F3 - 4”
LMP 953
0.4 0.36 LMP 950 0.36
MP 950 0.12 F3 - 4”
1 - 3” 0.4 0.24 LMP 951 4
F3 - 4” 0
0.24
LMP 950LMP 951 LMP 951 2
F3 - 4” 0.24 0 400 800 1200 1600 2000
F1 - 3” F1 - 3” 0.2 0 0.24

∆p bar

∆p bar
LMP 951 0.2 0.12 0 2
50 1400 1750 600 1200 1800 2400 3000 0.120
F1 - 3”
0 0.12 Pressure0.12
drop0 of filter complete
400 with 800
cartridge, 1200 1600 2000

954 0 1000 500 1000 1500 2000 2500 oil viscosity 30 mm 0 2 /s (cSt)
100 0 500 600 1000 1200 1500 18002000 2400 2500 3000 0 0 400 800 1200 1600 2000
050 1400 1750 0 600 1200 1800 2400 3000
Valves 0 0
0pressure drop
600 1200 1800 2400 3000 Pressure drop of filter
0LMP 952complete
600 with cartridge, 1800
1200 A03 A06 2400A10 A16 3000
1050 1400 1750 LMP
Bypass 953
valve 0.6
oil viscosity 30 mm /s (cSt)
50 0.36 Flow rate l/min
2
Flow rate l/min
” Pressure drop of filter complete with cartridge, A25
Valves
LMP 952 - 954 oil viscosity 30 mm 2 /s (cSt)
LMP 951 Valves valve pressure drop
Bypass 6
F3 - 4” 0.24 LMP 953 0.4 LMP 952 A03 A06 A10 A16
0.36 drop
Bypass valve pressure 0.6 M25
50 LMP 954
” LMP 952 A25
0.36 A03 A06 A10 A16
LMP 950 LMP 951 - 4951 LMP 953
LMP 950 0.36 0.6954
LMP
6 0.12 950 - 951 0.36
0.2 A25
F3 - 4” F3 - 4” LMP
0.24 0.4
6 M25
LMP 951 0.24
00 2000 2500
F3 - 4” 0.24 0.4
2

∆p bar
4 0 0
0.24 M25
0.12 0 0.2
4 600 1200 1800 2400 3000 0 600 1200 1800 2400 3000
0.12 0.2
500 2000 2500 2 0.12
0 0.12
0 0 400 800 1200 1600 2000 0
2 0 600 1200 1800 2400 3000
1500 2000 2500 0 600 1200 1800 2400 3000 0
1200 1800 2400 3000 0 0
0 0 0 600 1200 1800 2400 3000
0 600 1200 1800 2400 3000 0 600 1200 1800 2400 3000
0 0 Pressure400drop
LMP 800complete1200
954 of filter 1600
with cartridge, 2000 0 600 Flow
1200 rate l/min
1800 2400 3000
0.36 LMP 953 A03 A06 A10
0 oil viscosity 800
400 30 mm /s (cSt)
2 1200 1600 2000 0.6
A16

Pressure drop of filter complete A25


0.24 LMP 954LMP 952 A03 A06 A10 A16 0.4 LMP 953 A03 A06 A10
with cartridge, 0.36 0.6 0.6
M25
A16
oil viscosity 30 mm2/s (cSt) LMP 954 A25 LMP 953 A03 A06 A10
0.36 0.6
0.12 A25
0.24 0.2 A16
0.4 0.4
M25
∆p bar

∆p bar

M25 A25
0.24 0.4
0 0
0.12 0 0.2 600 1200 1800 2400 3000 0.2 M25
0 600 1200 1800 2400 3000
00 1600 2000 0.12 0.2
0 0 0
1200 1800 2400 3000
0 0 600 6001200 12001800 2400
1800 2400 3000 3000 0 600 1200 1800 2400 3000
00 1600 2000 0 0
Flow rate l/min Flow rate l/min
0 600 1200 1800 2400 3000 0 600 1200 1800 2400 3000
1200 1600 2000
LMP 954
0.6
A03
A06
A10
LMP 953 A03 A06 A10
0.6 0.4 LMP 954 A16
A16 0.6
A03 A25
∆p bar

LMP 954 A06


A25 M25
0.6 A10
0.4 0.2 A03

LMP
0.4 A16 A06
M25 A10
A25
0.4 A16
0.2 M25
0 A25
0.2

1 952 - 954
0 600 1200 1800 2400 3000
M25
0.2 Flow rate l/min
0
1200 1800 2400 3000 Valves 0
0 600 1200 1800 2400 3000
Bypass valve 0 600
pressure drop 1200 1800 2400 3000
Bypass valve pressure drop 0
0 600 1200 1800 2400 3000
LMP 952 - 954
6
LMP 952
0.36
4
LMP 954
∆p bar

P 950 0.6
A03
- 3” 0.24 A06
A10 2
LMP 951
F1 - 3” 0.4 A16
0.12 A25
M25 0
0.2 0 400 800 1200 1600 2000
0 Flow rate l/min
50 1400 1750 0 600 1200 1800 2400 3000
0
The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968.Pressure
∆p varies
drop ofproportionally
filter complete withwith density.
cartridge,
0 600 1200 1800 2400 3000 oil viscosity 30 mm 2 /s (cSt)

LMP 953 LMP 952 A03 A06 A10 A16


0.36 0.6
0
A25

LMP 951
Low & Medium Pressure filters
F3 - 4” 374 0.24 0.4
M25
GENERAL INFORMATION LMP 952-953-954
Manifolds Focus on

Breather plug
G 1/2” - A/F 10

Oil drain plug


FA G 1/2” - A/F 10
Position of manifolds Indicator port
IN - OUT connections Plug T2 - A/F 30

Indicator port - Plug T2 - A/F 30


Oil drain plug - G 1/2” - A/F 10

Execution P02 CMV4 & CUV4 Flange options


Code Thread Materials
1 - 4” SAE flange
2 - O-R 4437 (FPM) for flange
3 - Plug G 1-1/4”
CMV4 G 1 1/4” 4 - O-R 3168 for plug (FPM)
5 - No. 4 Hex bolt screws UNI-EN 24017
M16 x 65-10.9
6 - No. 4 Spring washers UNI 1751-B 16
7 - No. 4 Nuts UNI 5587 - M16

1 - 4” SAE flange
2 - O-R 4437 (FPM) for flange
3 - Plug SAE 20 1 5/8” - 12 UN
CUV4 SAE 20 4 - 1147 O-R for plug (FPM)
5 - No. 4 Hex bolt screws 5/8” UNC x 2 1/2”
6 - No. 4 Spring washers UNI 1751-B 16
7 - No. 4 Nuts 5/8” UNC

2 1

“Internal tube
for reduced flow rate”
4
is recommended for
flow rate values below: 3
Oil drain plug
LMP 952 - 300 l/min Flange with oil drain plug
LMP 953 - 450 l/min for rapid discharge
LMP 954 - 600 l/min
7 6 5
The use of option P02
makes it easier to fill the
housing with the operating fluid.

375 Low & Medium Pressure filters


LMP 952-953-954
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP952 3 B A FA A10 N P01
LMP952 LMP953 LMP954
Length
3
Bypass valve
S Without bypass B 3.5 bar

Seals and treatments


A NBR
V FPM

Connections
FA 4” SAE 3000 psi

Filtration rating (filter media)


A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm

WA025 Water absorber inorganic microfiber 25 µm


Element ∆p Execution
N 20 bar P01 MP Filtri standard
P02 With internal tube for reduced flow rate
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU950 3 A10 A N P01
CU950
Element length
3
Filter series and size
LMP952 Nr. 2 filter elements
LMP953 Nr. 3 filter elements
LMP954 Nr. 4 filter elements
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Seals
A NBR
V FPM
Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 376


LMP 952-953-954
Dimensions
LMP952

Breather plug

Drain plug

IN
T2 plug

OUT

T2 plug =
connection for differential indicator

377 Low & Medium Pressure filters


LMP 952-953-954
Dimensions
LMP953

Breather plug

Drain plug

IN

T2 plug

OUT

T2 plug =
connection for differential indicator

Low & Medium Pressure filters 378


LMP 952-953-954
Dimensions
LMP954

Breather plug

Drain plug

IN

T2 plug

OUT

T2 plug =
connection for differential indicator

379 Low & Medium Pressure filters


LMP 952-953-954 SPARE PARTS
Order number for spare parts
LMP 952 - 953 - 954

2
5b
5
5a

3
6d 6
6b
6c
6c
6b
6a

Item 7:
for complete filter code and
spare parts, see
LMP 950 - 951 series chapter

Quantity:
- filter spare parts:
LMP 952 - 2 pcs.
LMP 953 - 3 pcs.
LMP 954 - 4 pcs.

- filter seal kit:


LMP 952 - 2 pcs.
LMP 953 - 3 pcs.
LMP 954 - 4 pcs.
Item: 2 3 4 5 (5a-5b) 6 (6a ÷ 6d) 7
Filter Manifold 4” SAE 3000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter
series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty
LMP 952 1 pc. 01039270 01039271 2 pcs. 1 pc. 02050404 02050405 1 pc. 02049051 2 pcs.
LMP 953 1 pc. 01039337 01039338 2 pcs. 01042012 1 pc. 02050404 02050405 1 pc. 02049052 3 pcs. LMP9513xxF1xxxNP0x
LMP 954 2 pcs. 01039270 01039271 2 pcs. 1 pc. 02050406 02050407 1 pc. 02049053 4 pcs.

Low & Medium Pressure filters 380


LMP 952-953-954

381 Low & Medium Pressure filters


Low & Medium Pressure filters 382
Low & Medium Pressure filters

LMD 211 series


Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

383 Low & Medium Pressure filters


LMD 211 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Aluminium
Duplex
- Bowl: Cataphoretic Painted Steel
Maximum working pressure up to 6 MPa (60 bar) - Bypass valve: AISI 304 - Nylon
Flow rate up to 330 l/min
LMD211 is a range of versatile low pressure duplex filter with integrated
changeover function to allow the filter element replacement without the
Pressure
system shut-down. - Test pressure: 9 MPa (90 bar)
They are directly connected to the lines of the system through the - Burst pressure: 21 MPa (210 bar)
hydraulic fittings. - Pulse pressure fatigue test: 1 000 000 cycles
with pressure from 0 to 6 MPa (60 bar)
Available features:
- Female threaded connections up to 1 1/2” and flanged connections Bypass valve
up to 1 1/2”, for a maximum flow rate of 330 l/min - Opening pressure 350 kPa (3.5 bar) ±10%
- Fine filtration rating, to get a good cleanliness level into the system - Other opening pressures on request.
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document
and the dedicate leaflet. ∆p element type
- Balancing valve integrated in the changeover lever, to equalize the - Microfibre filter elements - series N: 20 bar
housing pressure before the switch - Fluid flow through the filter element from OUT to IN
- Bypass valve, to relieve excessive pressure drop across the filter media
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work Seals
- Optional sampling ports, to get samples of fluid or to connect additional - Standard NBR series A
instrument to the system - Optional FPM series V
- Visual, electrical and electronic differential clogging indicators

Common applications: Temperature


- Systems where shut-down causes high costs From -25° C to +110° C
- Systems where shut-down causes safety issues
Connections
Inlet/Outlet In-Line

Note
LMD 211 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 1 2 3 Length 1 2 3
LMD 211 9.5 11.2 12.8 4.1 4.6 5.3

Low & Medium Pressure filters 384


GENERAL INFORMATION LMD 211
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
Filter series Length A03 A06 A10 A16 A25 M25 M60 M90 M250 P10 P25
1 90 95 140 147 156 191 192 192 193 177 181
LMD 211 2 113 121 158 162 173 192 192 193 193 181 183
3 131 146 166 169 177 193 194 194 194 184 187
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Style S Style B
LMD 211 • •

OUT OUT

D.I. D.I.

LMD 210 Δp Housing


0.9
1” IN 1 1/4” 1 1/2” IN

0.6
Δp bar

0.3

0
0 80 160 240 320 400
Flow rate l/min

LMD 211 Δp Housing LMD 211 Δp


0.9 0.9 Pressure drop
1” 1 1/4” 1 1/2”
Filter housings ∆p pressure drop
LMD 211 Δp Housing
0.9
0.6 0.6
∆p bar Δp bar

0.6
0.3 0.3

0.3
0 0
0 80 160 240 320 400 0 50 100 150 200 250
Flow rate l/min
0
0 50 100 150 200 250
Valves
Flow rate l/min
Bypass valve pressure drop

Bypass valve pressure drop


LMD 211
9

6
∆p bar

0
0 100 200 300 400 500
Flow rate l/min

The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.

385 Low & Medium Pressure filters


LMD 211
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMD211 3 B A C 6 A10 N P01
LMD211
Length
1 2 3
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
C G 1 1/2”
F 1 1/2” NPT
I SAE 24 - 1 7/8” - 12 UN
L 1 1/2” SAE 3000 psi/M + G 1 1/4”
M 1 1/2” SAE 3000 psi/UNC + 1 1/4” NPT
N 1 1/2” SAE 3000 psi/UNC + SAE 20 - 1 5/8” UN
Connection for differential indicator
6 With plugged connection

Filtration rating (filter media)


A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series and size Configuration example: CU210 3 A10 A N P01
CU210
Element length
1 2 3
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • • Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 386


LMD 211
Dimensions
LMD211
Filter H
length [mm]
1 383
2 513
3 651

Connections R
C M10
F-I 3/8” UNC
L M10
M-N 3/8” UNC

R - depth 15 mm
Nr. 3 holes

IN OUT

Breather plug

Drain plug
Recommended
clearance space
for maintenance

R - depth 15 mm
Nr. 4 holes

Connection for
differential indicator
T2 plug

387 Low & Medium Pressure filters


LMD 211 SPARE PARTS
Order number for spare parts
LMD 211

3d

3e

3c

3a

3b

3f

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 2 pcs.


Item: 2 3 (3a ÷ 3f) 4
Filter Filter Seal Kit code number Indicator connection plug
series element NBR FPM NBR FPM
See
LDD order 02050671 02050672 T2H T2V
table

Low & Medium Pressure filters 388


LMD 211

389 Low & Medium Pressure filters


Low & Medium Pressure filters 390
Low & Medium Pressure filters

LMD 400-401 & 431 series


Maximum working pressure up to 1.6 MPa (16 bar) - Flow rate up to 590 l/min

391 Low & Medium Pressure filters


LMD 400-401 & 431 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Duplex
- Housing: Anodized Aluminium
Maximum working pressure up to 1.6 MPa (16 bar) - Manifolds: Steel - Painted black
Flow rate up to 590 l/min - Bypass valve: Steel
LMD400 is a range of versatile low pressure duplex filter with integrated - 3-way ball valve: Steel housings - Stainless Steel ball
changeover function to allow the filter element replacement without the - Valve: Phosphatized Steel - Stainless Steel
system shut-down.
They are directly connected to the lines of the system through the
Pressure
hydraulic fittings.
Test pressure: 2.5 MPa (25 bar)
Available features:
- 2 1/2” flanged connections, for a maximum flow rate of 590 l/min Bypass valve
- LMD400: In-line connections - Opening pressure 350 kPa (3.5 bar) ±10%
- LMD401: In-line connections with compact design - Other opening pressures on request.
- LMD431: In-line connections with compact design and base mounting
- Base-mounting design also available, for ease of the replacement of
the filter element ∆p element type
- Fine filtration rating, to get a good cleanliness level into the system - Microfibre filter elements - series N - W: 20 bar
- Water removal elements, to remove the free water from the hydraulic fluid. - Fluid flow through the filter element from OUT to IN
For further information, see the Contamination Management document
and the dedicate leaflet. Seals
- Balancing valve, to equalize the housing pressure before the switch
FPM series V
- Bypass valve, to relieve excessive pressure drop across the filter media
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work Temperature
- Visual, electrical and electronic differential clogging indicators From -25° C to +110° C

Common applications:
- Systems where shut-down causes high costs Connections
- Systems where shut-down causes safety issues - LMD 400-401: In-line Inlet/Outlet
- LMD 401: Same side
- LMD 400-401-431: In-Line

Note
LMP 400 - 401 - 431 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 4 5 6 Length 4 5 6
LMD 400 - 401 60 65 72 20 28 33
LMD 431 - 68 78 - 28 33

Low & Medium Pressure filters 392


GENERAL INFORMATION LMD 400-401 & 431
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 M60
A25 P10 P25
M90
M250
4 308 349 453 474 530 628 547 567
LMD 400 - 401 5 395 427 509 547 589 637 577 592
6 429 483 558 568 597 639 583 597

5 395 427 509 547 589 637 577 592


LMD 431
6 429 483 558 568 597 639 583 597
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S Execution B
LMD 400 - 401 • •
LMD 431 • •
OUT OUT

D.I.
D.I. D.I. D.I.

IN IN

LMD 400 - 401 - 431


0.6
Pressure drop
LMD 400 - 401 - 431 Filter housings ∆p pressure drop
0.6
0.4

0.4
0.2
∆p bar

0.2
0
100 200 300 400 500 600

0
100 200 300 400 500 600
Flow rate l/min

Bypass valve pressure drop


LMD 400 - 401 - 431
9

LMD 400 - 401 - 431


69
∆p bar

36

30
0 140 280 420 560 700
Flow rate l/min
0
0 are plotted
The curves 140 280mineral420
using density of 700
oil with 560 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.

393 Low & Medium Pressure filters


LMD 400-401 & 431 GENERAL INFORMATION
Focus on

A Breather plug G 3/8” - A/F 8


B Indicator port Plug T2 - A/F 30
C Compensation valve LMP 400 - 401 & 431 A
D Oil drain plug G 3/8” - A/F 8 Fit one differential indicator for individual filter assembly.

B
A B
D

A
C
C
B
B
D

LMD 431: Execution P02

“Internal tube
for reduced flow rate”
is recommended
for flow rate values
below 150 I/min.

The use of option P02


makes it easier to fill
the housing with the
operating fluid.

Low & Medium Pressure filters 394


LMD 400-401 & 431

395 Low & Medium Pressure filters


LMD 400-401
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMD401 4 B V F1 A10 N P01
LMD400 LMD401
Length
4 5 6
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
V FPM • • •
Connections LMD400 LMD401
F1 2 1/2” SAE 3000 psi/M • •
F2 2 1/2” SAE 3000 psi/UNC • •
F3 2 1/2” SAE 3000 psi/M, In-line connections •
F4 2 1/2” SAE 3000 psi/UNC, In-line connections •
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Filter length
Element ∆p Execution 4 5 6
N 20 bar P01 MP Filtri standard • • •
P02 Maintenance from the bottom of the housing • •
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU400 4 A10 V N P01
CU400
Element length
4 5 6
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Filtration rating
Seals Axx Mxx Pxx
V FPM • • •
Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 396


LMD 400-401
Dimensions
LMD400
Length 4
Connections R
F1 M12
F2 1/2” UNC
F3 M12
F4 1/2” UNC

IN OUT

Recommended
clearance space
Drain plug for maintenance

R - depth 20 mm
Nr. 4 holes

Bypass valve

Breather plug T2 plug

T2 plug =
Connection for differential indicator

397 Low & Medium Pressure filters


LMD 400-401
Dimensions
LMD400
Length 5 - 6
H2 [mm]
Filter H Execution
length [mm] P01 P02
5 883 120 660
6 1213 120 690

Connections R
F1 M12
F2 1/2” UNC
F3 M12
F4 1/2” UNC

IN OUT

Drain plug

R - depth 20 mm
Nr. 4 holes
H2 - Recommended
clearance space
for maintenance

Bypass valve

Breather plug T2 plug

T2 plug =
Connection for differential indicator

Low & Medium Pressure filters 398


LMD 400-401
Dimensions
LMD401
Length 4

Connections R
F1 M12
F2 1/2” UNC
F3 M12
F4 1/2” UNC

Connections Connections

OUT OUT

Breather plug
Bypass plug

IN T2 plug
R - depth 20 mm
Nr. 4 holes

Drain plug
T2 plug =
connection for differential indicator

Recommended
clearance space
for maintenance

399 Low & Medium Pressure filters


LMD 400-401
Dimensions
LMD401
Length 5 - 6
H2 [mm]
Filter H Execution
length [mm] P01 P02
5 1044 120 660
6 1374 120 690

Connections R
F1 M12
F2 1/2” UNC
F3 M12
Connections Connections F4 1/2” UNC

OUT OUT

Breather plug
Bypass plug

IN T2 plug
R - depth 20 mm
Nr. 4 holes

Drain plug
T2 plug =
connection for differential indicator

H2 - Recommended
clearance space
for maintenance

Low & Medium Pressure filters 400


LMD 400-401

401 Low & Medium Pressure filters


LMD 431
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMD431 5 B V F1 A10 N P01
LMD431
Length
5 6
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
V FPM • • •
Connections
F1 2 1/2” SAE 3000 psi/M
F2 2 1/2” SAE 3000 psi/UNC
F3 2 1/2” SAE 3000 psi/M, In-line connections
F4 2 1/2” SAE 3000 psi/UNC, In-line connections
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
Element ∆p Execution
WA025 Water absorber inorganic microfiber 25 µm N 20 bar P01 MP Filtri standard
P02 With internal tube for reduced flow rate
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU400 5 A10 V N P01
CU400
Element length
5 6
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Filtration rating
Seals Axx Mxx Pxx
V FPM • • •

Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 402


LMD 431
Dimensions
LMD431
Filter H H2
length [mm] [mm]
5 1161 660
6 1491 690

Breather plug

Connection for
differential indicator
T2 plug

IN

Drain plug

OUT OUT

Connections Connections

Fixing holes

Ø 15
Nr. 4 holes

403 Low & Medium Pressure filters


LMD 400-401 & 431 SPARE PARTS
Order number for spare parts
LMD 400

5a
5b
4b
5c 3
5d
4a
2 7

LMD 401 LMD 431

5a
5b
4b

4a

3 4a

2
5d
5c
7 3
6
4b

2 5b
5d
5c 5a

Q.ty: 1 pc. Q.ty: 2 pcs. Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 2 pcs.
Item: 2 3 4 (4a ÷ 4b) 5 (5a ÷ 5d) 6 7
Filter 3-way ball valve PN 16 Threaded Kit ball valve Filter
series 2 1/2” SAE 3000 psi/M 2 1/2” SAE 3000 psi/UNC One-way valve Seal Kit fasteners kit with hose fitting See order table

LMD 400-401-431 02001440 02001441 02001429 02050399 02049062 02025043 LMP400xF2.....

Low & Medium Pressure filters 404


LMD 400-401 & 431

405 Low & Medium Pressure filters


Low & Medium Pressure filters 406
Low & Medium Pressure filters

LMD 951 series


Maximum working pressure up to 1.6 MPa (16 bar) - Flow rate up to 1200 l/min

407 Low & Medium Pressure filters


LMD 951 GENERAL INFORMATION
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Duplex
- Housing: Anodized Aluminium
Maximum working pressure up to 1.6 MPa (16 bar) - Manifolds: Welded - Painted black
Flow rate up to 1200 l/min - Bypass valve: Steel
LMD950 is a range of versatile low pressure duplex filter with integrated - 3-way ball valve: Steel body - Stainless Steel ball
changeover function to allow the filter element replacement without the - Check valve: Cast Iron body - AISI 304 leaf
system shut-down.
They are directly connected to the lines of the system through the Pressure
hydraulic fittings. - SAE + DIN Flange
- Test pressure: 2.5 MPa (25 bar)
Available features:
- Flanged connections up to 4”, for a maximum flow rate of 1200 l/min Bypass valve
- Base-mounting design, for ease of the replacement of the filter element - Opening pressure 350 kPa (3.5 bar) ±10%
- Fine filtration rating, to get a good cleanliness level into the system - Other opening pressures on request.
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document Number of filter elements
and the dedicate leaflet. LMD 951: 2 filter elements CU950-3
- Balancing valve, to equalize the housing pressure before the switch
- Bypass valve, to relieve excessive pressure drop across the filter media ∆p element type
- Drain ports, to remove the fluid from the housing prior the maintenance work
- Microfibre filter elements - series N: 20 bar
- Visual, electrical and electronic differential clogging indicators
- Fluid flow through the filter element from OUT to IN
Common applications:
Seals
- Systems where shut-down causes high costs
FPM series V
- Systems where shut-down causes safety issues

Temperature
From -25° C to +110° C

Connections
- LMD 951: In-line Inlet/Outlet
- Same side

Note
LMD 951 filters
are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
DN 80 DN 100 DN 80 DN 100
LMD 951 102 130 62 66

Low & Medium Pressure filters 408


GENERAL INFORMATION LMD 951
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 A25 M60
M90
M250
LMD 951 3 853 884 995 1066 1096 1233

Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S Execution B
LMD 951 • •
LMD 951
1.2
OUT OUT
DN 80
0.8

D.I. D.I. D.I. D.I.


0.4
DN 100

0
IN IN 0 240 280 720 960 1200

Pressure drop
Filter housings Bypass valve
LMD 951 LMD 951
1.2 ∆p pressure drop 6 pressure drop

DN 80
0.8 4
∆p bar

∆p bar

0.4 2
DN 100

0 0
0 240 280 720 960 1200 0 400 800 1200 1600 2000
Flow rate l/min Flow rate l/min
The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.

LMD 951
Focus
6 on Execution P02

2 B
“Internal tube
0 for reduced flow rate”
0 400 800 1200 1600 2000 is recommended
for flow rate values
below 100/150 I/min.
C A
The use of option P02
LMD 951 makes it easier to fill
Fit one differential indicator the housing with the
for individual filter assembly. operating fluid.
A
A Indicator port Plug T2 - A/F 30
B Compensation valve
C Oil drain plug G 1/2” - A/F 10

409 Low & Medium Pressure filters


LMD 951
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMD951 3 B V F1 A10 N P01
LMD951
Length
3
Bypass valve
S Without bypass B 3.5 bar

Seals and treatments


V FPM
Connections
F1 3” SAE 3000 psi/M
F2 3” SAE 3000 psi/UNC
F3 4” SAE 3000 psi/M
F4 4” SAE 3000 psi/UNC
F5 3” SAE 3000 psi/M, In-line connections
F6 3” SAE 3000 psi/UNC, In-line connections
F7 4” SAE 3000 psi/M, In-line connections
F8 4” SAE 3000 psi/UNC, In-line connections
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm Element ∆p Execution
N 20 bar P01 MP Filtri standard
WA025 Water absorber inorganic microfiber 25 µm P02 With internal tube for reduced flow rate
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU950 3 A10 V N P01
CU950
Element length
3
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm

WA025 Water absorber inorganic microfiber 25 µm

Seals
V FPM

Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 410


LMD 951
Dimensions

Recommended clearance space


for maintenance

Breather plug

Connection for
differential indicator
T2 plug
IN

Drain plug

OUT OUT

Connections Connections

Fixing holes

Ø 15
Nr. 4 holes

LMD951
H L L1 M
Connections [mm] [mm] [mm] [mm]
F1 1530 838 588 370
F2 1530 838 588 370
F3 1577 932 682 650
F4 1577 932 682 650
F5 1530 838 588 370
F6 1530 838 588 370
F7 1577 932 682 650
F8 1577 932 682 650

411 Low & Medium Pressure filters


LMD 951 SPARE PARTS
Order number for spare parts
LMD 951

2
4a
5f
5e

4b

5b

5a

4a
3
4a
5d
5f
5c

Item 7:
for complete filter code and
spare parts, see
LMP 950 - 951 series chapter

Quantity:
- filter spare parts: 2 pcs.
- filter seal kit: 2 pcs.
Q.ty: 1 pc. Q.ty: 2 pcs. Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 2 pcs.
Item: 2 3 4 5 (5a ÷ 5f) 6 7
Filter series 3-way ball valve PN 16 One-way Seal Kit Threaded G 1/2” Ball Valve Kit Filter
LMD 951 valve fasteners kit with straight fittings
F1 - F2 - F5 - F6 / D1 - D3 3” SAE 3000 psi/M 3” SAE 3000 psi/UNC
(3” SAE / DIN PN16 DN 80) 02001135 02001438 02001418 02050388 02049056 LMP9513xVF1xxxNP01
02025043
F3 - F4 - F7 - F8 / D2 - D4 4” SAE 3000 psi/M 4” SAE 3000 psi/UNC
02001419 02050389 02049057 LMP9513xVF3xxxNP01
(4” SAE / DIN PN16 DN 100) 02001162 02001439

Low & Medium Pressure filters 412


LMD 951

413 Low & Medium Pressure filters


Low & Medium Pressure filters 414
Low & Medium Pressure filters

DIN 24550 Filter element according to DIN 24550

LDP & LDD series


Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

LMP 900-901 series


Maximum working pressure up to 3 MPa (30 bar) - Flow rate up to 2000 l/min

LMP 902-903 series


Maximum working pressure up to 2 MPa (20 bar) - Flow rate up to 3000 l/min

415 Low & Medium Pressure filters


Low & Medium Pressure filters 416
Low & Medium Pressure filters

LDP & LDD series


Filter element according to DIN 24550
Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

417 Low & Medium Pressure filters


LDP & LDD GENERAL INFORMATION
Filter element according to DIN 24550
Descriptions Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Aluminium
Maximum working pressure up to 6 MPa (60 bar)
- Bowl: Cataphoretic Painted Steel
Flow rate up to 330 l/min - Bypass valve: AISI 304 - Nylon
LDP is a range of versatile low pressure filter for transmission, protection
of sensitive components in low pressure hydraulic systems and filtration
of the coolant into the machine tools. Pressure
They are also suitable for the off-line filtration of small reservoirs. - Test pressure: 9 MPa (90 bar)
They are directly connected to the lines of the system through the - Burst pressure: 21 MPa (210 bar)
hydraulic fittings. - Pulse pressure fatigue test: 1 000 000 cycles
with pressure from 0 to 6 MPa (60 bar)
Available features:
- Female threaded connections up to 1 1/2”, for a maximum return flow
rate of 330 l/min
- Filter element designed in accordance with DIN 24550 regulation Bypass valve
- Fine filtration rating, to get a good cleanliness level into the system - Opening pressure 350 kPa (3.5 bar) ±10%
- Water removal elements, to remove the free water from the hydraulic fluid. - Other opening pressures on request.
For further information, see the Contamination Management document
and the dedicate leaflet.
- Bypass valve, to relieve excessive pressure drop across the filter media ∆p element type
- Visual, electrical and electronic differential clogging indicators
- Microfibre filter elements - series N: 20 bar
Common applications: - Fluid flow through the filter element from OUT to IN
Delivery lines, in low pressure industrial equipment or mobile machines

LDD is a range of versatile low pressure duplex filter with integrated Seals
changeover function to allow the filter element replacement without the - Standard NBR series A
system shut-down. - Optional FPM series V
They are directly connected to the lines of the system through the
hydraulic fittings.
Temperature
Available features:
- Female threaded connections up to 1 1/2” and flanged connections From -25° C to +110° C
up to 1 1/2”, for a maximum
flow rate of 330 l/min
- Filter element designed in accordance with DIN 24550 regulation Connections
- Fine filtration rating, to get a good cleanliness level into the system Inlet/Outlet In-Line
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document
and the dedicate leaflet.
- Balancing valve integrated in the changeover lever, to equalize the housing Note
pressure before the switch LDP - LDD filters are provided
- Bypass valve, to relieve excessive pressure drop across the filter media for vertical mounting
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work
- Optional sampling ports, to get samples of fluid or to connect additional
instrument to the system
- Visual, electrical and electronic differential clogging indicators

Common applications:
- Systems where shut-down causes high costs
- Systems where shut-down causes safety issues

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
LDP 016 2.0 1.2
LDP 025 3.0 1.6
LDP 040 5.0 2.2
LDD 016 9.3 3.6
LDD 025 9.5 4.1
LDD 040 11.3 4.8

Low & Medium Pressure filters 418


GENERAL INFORMATION LDP & LDD
Filter element according to DIN 24550
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
Filter series A03 A06 A10 A16 A25 M25 M60 M90 M250 P10 P25
LDP 016 83 91 178 198 222 350 353 358 359 295 309
LDP 025 124 134 227 245 265 357 358 358 359 319 330
LDP 040 173 191 274 284 311 359 360 361 362 332 337

LDD 016 68 73 120 130 140 189 190 192 192 169 174
LDD 025 93 98 142 149 157 191 192 192 192 178 181
LDD 040 118 126 161 165 175 192 192 193 193 182 184
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S Execution B Execution S Execution B
LDP 016 • •
LDP 025 • •
LDP 040 • •
LDD 016 • •
LDD 025 LMP 210 - Δp Housing • •
0.9
LDD 040 • •
1” 1 1/4” 1 1/2”
OUT OUT
LMP 210
LMP-210
Δp -Housing
Δp Housing OUT OUT
0.9 0.6
0.9
1” 1”
1 1/4”1 1/4”1 1/2”1 1/2”
Δp bar Δp bar

0.6 0.6 D.I. D.I.


0.3 D.I. D.I.
Δp bar

0.3 0.3 IN IN
0
0 80 160 240 320 400 IN IN
Flow rate l/min
0 0
0 0 80 80 160 160 240 240 320 320 400 400
FlowFlow
rate rate
l/minl/min
LDP - Δp LDD - Δp
0.9 0.9 Pressure drop
Filter housings ∆p pressure drop
LDP -LDP
Δp - Δp Housing 1” 1 1/4” 1 1/2” LDD -LDD
Δp -Housing
Δp
0.9 0.6
0.9 0.9 0.6
0.9

1” 1” 1 1/4”1 1/4”1 1/2”1 1/2”


0.6 0.6
0.3 0.6 0.6
0.3
∆p bar

∆p bar

0.3 0.3 0.3 0.3


0 0
0 80 160 240 320 400 0 50 100 150 200 250

0 0 0 0
0 0 80 80 160 160 240 240 320 320 400 400 0 0 50 50 100 100 150 150 200 200 250 250
Valves
Flow rate l/min Flow rate l/min
Bypass valve pressure drop
ValvesValves
BypassBypass
valve pressure
valve LDD
pressure
drop drop
Bypass valve pressure drop
- LDP
9

LDD -LDD
LDP- LDP
9 9
6
∆p bar

6 36

3 3
0
0 100 200 300 400 500
0 0 Flow rate l/min
0 0 100 100 200 200 300 300 400 400 500 500
The curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.

419 Low & Medium Pressure filters


LDP Filter element according to DIN 24550
Designation & Ordering code

COMPLETE FILTER
Series Configuration example: LDP 025 B A D 6 A10 N P01
LDP
Size
016 Element according to DIN 24550 - T3 DN160
025 Element according to DIN 24550 - T3 DN250
040 Element according to DIN 24550 - T3 DN400
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
A G 1” F 1 1/2” NPT
B G 1 1/4” G SAE 16 - 1 5/16” - 12 UN
C G 1 1/2” H SAE 20 - 1 5/8” - 12 UN
D 1” NPT I SAE 24 - 1 7/8” - 12 UN
E 1 1/4” NPT
Connection for differential indicator
6 With plugged connection
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series Configuration example: DN 025 A10 A N P01
DN
Element size
016 Element according to DIN 24550 - T3 DN160
025 Element according to DIN 24550 - T3 DN250
040 Element according to DIN 24550 - T3 DN400
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm

WA025 Water absorber inorganic microfiber 25 µm


Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • • Element ∆p Execution
W NBR compatible with fluids HFA-HFB-HFC • • N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 420


Filter element according to DIN 24550 LDP
Dimensions
LDP
Filter H
size [mm]
016 268
025 358
IN OUT 040 508

Connections R
A-B-C M8
D-E-F-G-H-I 5/16” UNC

Recommended
clearance space
for maintenance

Connection for
differential indicator
T2 plug

R - depth 12 mm
Nr. 4 holes

421 Low & Medium Pressure filters


LDD Filter element according to DIN 24550
Designation & Ordering code

COMPLETE FILTER
Series Configuration example: LDD 025 B A C 6 A10 N P01
LDD
Size
016 Element according to DIN 24550 - T3 DN160
025 Element according to DIN 24550 - T3 DN250
040 Element according to DIN 24550 - T3 DN400
Bypass valve
S Without bypass B 3.5 bar
Filtration rating
Seals and treatments Axx Mxx Pxx
A NBR • • •
V FPM • • •
W NBR compatible with fluids HFA-HFB-HFC • •
Connections
C G 1 1/2”
F 1 1/2” NPT
I SAE 24 - 1 7/8” - 12 UN
L 1 1/2” SAE 3000 psi/M + G 1 1/4”
M 1 1/2” SAE 3000 psi/UNC + 1 1/4” NPT
N 1 1/2” SAE 3000 psi/UNC + SAE 20 - 1 5/8” UN
Connection for differential indicator
6 With plugged connection
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series Configuration example: DN 025 A10 A N P01
DN
Element size
016 Element according to DIN 24550 - T3 DN160
025 Element according to DIN 24550 - T3 DN250
040 Element according to DIN 24550 - T3 DN400
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm P10 Resin impregnated paper 10 µm
A25 Inorganic microfiber 25 µm P25 Resin impregnated paper 25 µm
WA025 Water absorber inorganic microfiber 25 µm
Filtration rating
Seals Axx Mxx Pxx
A NBR • • •
V FPM • • • Element ∆p Execution
W NBR compatible with fluids HFA-HFB-HFC • • N 20 bar P01 MP Filtri standard
Pxx Customized
ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 422


Filter element according to DIN 24550 LDD
Dimensions
LDD
Filter H
size [mm]
016 293
025 383
040 533

Connections R
C M10
F-I 3/8” UNC
L M10
M-N 3/8” UNC

R - depth 15 mm
Nr. 3 holes

IN OUT

Breather plug

Drain plug
Recommended
clearance space
for maintenance

R - depth 15 mm
Nr. 3 holes

Connection for
differential indicator
T2 plug

423 Low & Medium Pressure filters


LDP SPARE PARTS
Filter element according to DIN 24550

Order number for spare parts


LDP

3c

3d

3a

3b

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 1 pc.


Item: 2 3 (3a ÷ 3d) 4
Filter Filter Seal Kit code number Indicator connection plug
series element NBR FPM NBR FPM
See
LDP order 02050435 02050436 T2H T2V
table

Low & Medium Pressure filters 424


SPARE PARTS LDD
Filter element according to DIN 24550

Order number for spare parts


LDD

3d

3e

3c

3a

3b

3f

Q.ty: 1 pc. Q.ty: 1 pc. Q.ty: 2 pc.


Item: 2 3 (3a ÷ 3i) 4
Filter Filter Seal Kit code number Indicator connection plug
series element NBR FPM NBR FPM
See
LDD order 02050671 02050672 T2H T2V
table

425 Low & Medium Pressure filters


Low & Medium Pressure filters 426
Low & Medium Pressure filters

LMP 900-901 series Filter element according to DIN 24550


Maximum working pressure up to 3 MPa (30 bar) - Flow rate up to 2000 l/min

427 Low & Medium Pressure filters


LMP 900-901 GENERAL INFORMATION
Filter element according to DIN 24550
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Maximum working pressure up to 3 MPa (30 bar)
- Housing: Anodized Aluminium
Flow rate up to 2000 l/min - Manifolds: Anodized Aluminium
LMP900 is a range of low pressure filter with large filtration surface - Bypass valve: Steel
mainly suitable for lubrication, off-line filtration of the reservoirs and
filtration equipment. Pressure
They are directly connected to the lines of the system through the - Test pressure: 4.5 MPa (45 bar)
hydraulic fittings. - Burst pressure: 12 MPa (120 bar)
- Pulse pressure fatigue test: 1 000 000 cycles
Available features: with pressure from 0 to 3 MPa (30 bar)
- Flanged connections up to 4”, for a maximum flow rate of 2000 l/min
- In line or 90° connections, to meet any type of application Bypass valve
- Filter element designed in accordance with DIN 24550 regulation - Opening pressure 350 kPa (3.5 bar) ±10%
- Fine filtration rating, to get a good cleanliness level into the system - Other opening pressures on request.
- Water removal elements, to remove the free water from the hydraulic fluid.
For further information, see the Contamination Management document
Number of filter elements
and the dedicate leaflet.
LMP 900-1: 1 filter element CU900
- Bypass valve, to relieve excessive pressure drop across the filter media
LMP 900-2: 2 filter elements CU900
- Vent ports, to avoid air trapped into the filter going into the system
- Drain ports, to remove the fluid from the housing prior the maintenance work
- Visual, electrical and electronic differential clogging indicators Filter elements
Filter element according to DIN 24550
Common applications: Size: 1000
- Off-line filtration of reservoirs
- Filtration systems ∆p element type
- Lubrication systems - Microfibre filter elements - series N: 20 bar
- Fluid flow through the filter element from OUT to IN

Connections
LMP 900: In-line Inlet/Outlet
LMP 901: 90° Inlet/Outlet

Seals
- Standard NBR series A
- Optional FPM series V

Temperature
From -25 °C to +110 °C

Note
LMP 900 - 901 filters are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 1 2 Length 1 2
LMP 900-901 19.2 30.4 16 24

Low & Medium Pressure filters 428


GENERAL INFORMATION LMP 900-901
Filter element according to DIN 24550
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 A25 M60
M90
M250
1 706 877 1264 1291 1444 1803
LMP 900 2 1100 1264 1556 1573 1668 1867

1 715 899 1337 1369 1552 2000


LMP 901 2 1147 1337 1689 1710 1828 2081
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

LMP 900-901 Length 2 Hydraulic symbols


LMP 900/901 Filter series
LMP 900-901
Execution S

LMP 902/903 Execution B

LMP 900/901 OUT OUT

LMP 900 - 901 length 2 filters


D.I. D.I.

LMP 900 - 901 - F1 - 3”


are equipped with two 1000
0.6 size cartridges in compliance
with DIN 24550 standard,
IN IN
connected
LMP 900by means of a LMP 900 - 901 - F1 - 3”
0.4 0.6
removable coupling spigot.
F1 - 3”

LMP 901
0.2 F1 - 3” LMP 900
0.4 LMP 902 - 903
F1 - 3”

LMP 900/901 LMP 902/903


0.36
0 LMP 901
0.2 F1 - 3” LMP 902
100 300 600 900 1200 1500
0.24

0 LMP 903
LMP 900 - 901 - F3 - 4” 100 300 600 900 1200 0.121500
0.6
Pressure drop
LMP 900
F3 - 4” 0 Filter housings ∆p pressure drop
0.4 LMP 900 - 901 - F1 - 3” LMP 900 - 901 - F3 - 4” 100 600 1200 1800 2400 30
0.6 0.6
LMP 901
F3 - 4” LMP 900
0.2 F3 - 4”
0.4 LMP 900 0.4
F1 - 3” Valves
∆p bar

∆p bar

LMP 901
Bypass
F3 - 4”valve pressure drop
0 LMP 901
0.2 0.2
100 400 800 1200 1600F1 - 3” 2000 LMP 902 - 903
0.36 LMP 902 - 903
9
0 0
100 300 600 900 1200 1500 100 400 800 1200 1600 2000 LMP 902
0.24
6
Valves Flow rate l/min Flow rate l/min
Bypass valve pressure drop LMP 903
LMP 900 - 901 - F3 - 4” 0.12
3
0.6 LMP 900 - 901 Valves
Bypass valve pressure drop
9
LMP 900 Bypass valve pressure drop
F3 - 4” 0
0
0.4 100 600 1200 1800 2400 30
LMP 900 - 901 0 240 480 720 960 12
6 LMP 901 9
∆p bar

F3 - 4”
0.2
3 Valves
6
Bypass valve pressure drop
0
0 100 400 800 1200 1600 2000
3 LMP 902 - 903
0 240 480 720 960 1200 9
Flow rate l/min
0
The
Valves curves are plotted using mineral oil with density of 0.86 kg/dm3 in compliance
0 240with ISO480
3968. ∆p720
varies proportionally
960 with density.
61200
Bypass valve pressure drop
429 Low & Medium Pressure filters
3
LMP 900 - 901
LMP 900-901 Filter element according to DIN 24550
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP901 2 B A F2 A10 N P01
LMP900 LMP901
Length
1 2
Bypass valve
S Without bypass B 3.5 bar

Seals and treatments


A NBR
V FPM
Connections
F1 3” SAE 3000 psi/M
F2 3” SAE 3000 psi/UNC
F3 4” SAE 3000 psi/M
F4 4” SAE 3000 psi/UNC
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm

WA025 Water absorber inorganic microfiber 25 µm


Filter length
Element ∆p Execution 1 2
N 20 bar P01 MP Filtri standard • •
P02 Maintenance from the bottom of the housing •
Pxx Customized

FILTER ELEMENT
Element series and size Configuration example: CU900 A10 A N P01
CU900
Length
1 Nr. 1 filter element
2 Nr. 2 filter elements
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm
WA025 Water absorber inorganic microfiber 25 µm

Seals
A NBR
V FPM
Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447
Filter length Filter length
Additional features 1 2 page 1 2 page
T2 Plug • • 449 CFA Retaining clamp • 450

Low & Medium Pressure filters 430


Filter element according to DIN 24550 LMP 900-901
Dimensions
LMP900
Length 1
Connections R
OUT IN
F1 - F3 M16
F2 - F4 5/8” UNC

Drain plug Recommended


clearance space
for maintenance

T2 plug R - depth 25 mm
Nr. 4 holes

T2 plug =
connection for differential indicator

T2 plug Bypass valve

LMP900
Length 2
H2
Execution [mm]
OUT IN P01 130
P02 800

Connections R
F1 - F3 M16
F2 - F4 5/8” UNC

Drain plug
H2 - Recommended
clearance space
for maintenance
T2 plug R - depth 25 mm
Nr. 4 holes

T2 plug =
connection for differential indicator

T2 plug Bypass valve

431 Low & Medium Pressure filters


LMP 900-901 Filter element according to DIN 24550
Dimensions

R - depth 25 mm
LMP901
Nr. 4 holes Length 1
OUT
Connections R
F1 - F3 M16
IN F2 - F4 5/8” UNC

614 614
Drain plug Recommended
clearance space
for maintenance
T2 plug

T2 plug =
connection for differential indicator

T2 plug

R - depth 25 mm
LMP901
Nr. 4 holes Length 2
OUT H2
Execution [mm]
P01 130
IN P02 800

Connections R
F1 - F3 M16
F2 - F4 5/8” UNC
1035 1035

Drain plug

H2 - Recommended
T2 plug clearance space
for maintenance

T2 plug =
connection for differential indicator

T2 plug

Low & Medium Pressure filters 432


SPARE PARTS LMP 900-901
Order number for spare parts
LMP 900 - 901 LMP 900 - 901
length 1 length 2

4 3c 3d
4 3c 3d

3d
3d

3c
3c
3e
3e
4
4

3a

3a 3b

2
3b

3a
2

3a

3g

3a

3b

3g

Item: 2 3 (3a ÷ 3g) 4 5 6


Filter Filter element Seal Kit code number Indicator connection plug Housing spigot Coupling spigot
series Q.ty Q.ty NBR FPM Q.ty NBR FPM Q.ty Q.ty
LMP 900-901 length 1 1 pc. See 1 pc. 02050363 02050364 2 pcs. 1 pc. -
order T2H T2V 01044104 01044099
LMP 900-901 length 2 2 pcs. table 1 pc. 02050365 02050366 2 pcs. 1 pc. 1 pc.

433 Low & Medium Pressure filters


Low & Medium Pressure filters 434
Low & Medium Pressure filters

LMP 902-903 series Filter element according to DIN 24550


Maximum working pressure up to 2 MPa (20 bar) - Flow rate up to 3000 l/min

435 Low & Medium Pressure filters


LMP 902-903 GENERAL INFORMATION
Filter element according to DIN 24550
Description Technical data

Low & Medium Pressure filters Filter housing materials


- Head: Anodized Aluminium
Maximum working pressure up to 2 MPa (20 bar)
- Housing: Anodized Aluminium
Flow rate up to 3000 l/min - Manifolds: Welded - Phosphatized Steel
- Bypass valve: Steel
LMP902 and LMP903 are ranges of low pressure filter with large filtration - Size 1000 filter elements complying with DIN 24550 standard
surface mainly suitable for lubrication, off-line filtration of the reservoirs
and filtration equipment. Pressure
Multiple LMP950 filters are connected to a manifold to reduce the - Test pressure: 3.5 MPa (35 bar)
pressure drop caused by the filter media and to increase the life time
of the filter element. Bypass valve
They are directly connected to the lines of the system through the - Opening pressure 350 kPa (3.5 bar) ±10%
hydraulic fittings. - Other opening pressures on request.

Available features: Number of filter elements


- 4” flanged connections, for a maximum flow rate of 3000 l/min LMP 902: 4 filter elements CU900
- Filter element designed in accordance with DIN 24550 regulation LMP 903: 6 filter elements CU900
- Fine filtration rating, to get a good cleanliness level into the system
- Water removal elements, to remove the free water from the hydraulic fluid.
Filter elements
For further information, see the Contamination Management document Filter element according to DIN 24550
and the dedicate leaflet. Size: 1000
- Bypass valve, to relieve excessive pressure drop across the filter media
- Vent ports, to avoid air trapped into the filter going into the system
∆p element type
- Drain ports, to remove the fluid from the housing prior the maintenance work - Microfibre filter elements - series N: 20 bar
- Visual, electrical and electronic differential clogging indicators - Fluid flow through the filter element from OUT to IN

Connections
Common applications:
LMP 902-903: In-line Inlet/Outlet
- Off-line filtration of reservoirs
- Filtration systems Seals
- Standard NBR series A
- Optional FPM series V

Temperature
From -25 °C to +110 °C

Note
LMP 902 - 903 filters are provided
for vertical mounting

Weights [kg] and volumes [dm3]


Filter series Weights [kg] Volumes [dm3]
Length 2 Length 2
LMP 902 89.6 58
LMP 903 129.2 87

Low & Medium Pressure filters 436


GENERAL INFORMATION LMP 902-903
Filter element according to DIN 24550
FILTER ASSEMBLY SIZING
Flow rates [l/min]
Filter element design - N Series
M25
Filter series Length A03 A06 A10 A16 A25 M60
M90
M250
LMP 902 2 2217 2576 3241 3282 3506 3987
LMP 903 2 2838 3170 3720 3755 3926 4278
Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
The reference fluid has a kinematic viscosity of 30 mm2/s (cSt) and a density of 0.86 kg/dm3.
For different pressure drop or fluid viscosity we recommend to use our selection software available on www.mpfiltri.com.
You can also calculate the right size using the formulas present on the FILTER SIZING paragraph at the beginning of the full catalogue or at the beginning of the filter family brochure.
Please, contact our Sales Department for further additional information.

Hydraulic symbols
Filter series Execution S Execution B Execution S Execution B
LMP 902 • •

LMP 902/903
LMP 903 • •

LMP 902/903
OUT OUT OUT OUT

D.I. D.I. D.I. D.I.

IN IN IN IN

LMP 902 - 903


0.36 Pressure drop
Filter housings ∆p pressure drop
LMP 902 - 903 LMP 902
0.36
0.24

LMP 902 LMP 903


0.24
0.12
∆p bar

LMP 903
0.12
0
100 600 1200 1800 2400 3000

0
100 600 1200 1800 2400 3000
Valves Flow rate l/min
Bypass valve pressure drop
Valves Bypass valve pressure drop
LMP 902 - 903
Bypass valve
9 pressure drop

LMP 902 - 903


96
∆p bar

63

30
0 240 480 720 960 1200
Flow rate l/min
0
0
The curves are240 480 mineral
plotted using density of1200
720oil with960 0.86 kg/dm3 in compliance with ISO 3968. ∆p varies proportionally with density.

437 Low & Medium Pressure filters


LMP 902-903 GENERAL INFORMATION
Filter element according to DIN 24550
Manifolds

FA FB

FC FD

Position of manifolds
IN - OUT connections

Focus on

Bypass valve
Indicator port A/F 17
Plug T2 - A/F 30

Oil drain plug


G 1/2” - A/F 10

Low & Medium Pressure filters 438


LMP 902-903

439 Low & Medium Pressure filters


LMP 902-903 Filter element according to DIN 24550
Designation & Ordering code

COMPLETE FILTER
Series and size Configuration example: LMP902 2 B A FA A10 N P01
LMP902 LMP903
Length
2
Bypass valve
S Without bypass B 3.5 bar

Seals and treatments


A NBR
V FPM
Connections IN OUT
FA 4” SAE 3000 psi left left
FB 4” SAE 3000 psi left right
FC 4” SAE 3000 psi right left
FD 4” SAE 3000 psi right right
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm Element ∆p Execution
A25 Inorganic microfiber 25 µm N 20 bar P01 MP Filtri standard
Pxx Customized
WA025 Water absorber inorganic microfiber 25 µm

FILTER ELEMENT
Element series and size Configuration example: CU900 A10 A N P01
CU900
Filter series and size
LMP902 Nr. 4 filter elements
LMP903 Nr. 6 filter elements
Filtration rating (filter media)
A03 Inorganic microfiber 3 µm M25 Wire mesh 25 µm
A06 Inorganic microfiber 6 µm M60 Wire mesh 60 µm
A10 Inorganic microfiber 10 µm M90 Wire mesh 90 µm
A16 Inorganic microfiber 16 µm
A25 Inorganic microfiber 25 µm
WA025 Water absorber inorganic microfiber 25 µm

Seals
A NBR
V FPM
Element ∆p Execution
N 20 bar P01 MP Filtri standard
Pxx Customized

ACCESSORIES
Differential indicators page page
DEA Electrical differential indicator 445 DTA Electronic differential indicator 448
DEM Electrical differential indicator 445-446 DVA Visual differential indicator 448
DLA Electrical / visual differential indicator 446-447 DVM Visual differential indicator 448
DLE Electrical / visual differential indicator 447

Additional features page


T2 Plug 449

Low & Medium Pressure filters 440


Filter element according to DIN 24550 LMP 902-903
Dimensions
LMP902

OUT

T2 plug

Bypass valve
IN

Drain plug

T2 plug =
connection for differential indicator

441 Low & Medium Pressure filters


LMP 902-903 Filter element according to DIN 24550
Dimensions
LMP903

OUT

T2 plug

Bypass valve
IN

Drain plug

T2 plug =
connection for differential indicator

Low & Medium Pressure filters 442


SPARE PARTS LMP 902-903
Order number for spare parts
LMP 902 - 903

3
6a
6b
6c
6c
6b
6d 6

5a
5
5b

Item 7:
for complete filter code and
spare parts, see
LMP 900 - 901 series chapter
Quantity:
- filter spare parts:
LMP 902 - 2 pcs.
LMP 903 - 3 pcs.

- filter seal kit:


LMP 902 - 2 pcs.
LMP 903 - 3 pcs.

Item: 2 3 4 5 (5a-5b) 6 (6a ÷ 6d) 7


Filter Manifold 4” SAE 3000 psi plugged flange Manifolds seal kit Threaded fasteners kit Filter
series Q.ty IN OUT Q.ty Q.ty NBR FPM Q.ty Q.ty
LMP 902 1 pc. 01039270 01039271 2 pcs. 1 pc. 02050404 02050405 1 pc. 02049051 2 pcs.
01042012 LMP9012xxF1xxxNP02
LMP 903 1 pc. 01039337 01039338 2 pcs. 1 pc. 02050404 02050405 1 pc. 02049052 3 pcs.

443 Low & Medium Pressure filters


Low & Medium pressure filters

OUT OUT OUT

2 2
1 1
3 3

Clogging indicators
IN IN IN Differential indicators

Introduction
Filter elements are efficient only if their Dirt Holding Capacity is fully exploited.
OUT OUT OUT
This is achieved by using filter housings equipped with clogging indicators.

These devices trip when the clogging of the filter element causes an increase
in pressure drop across the filter element.

The indicator is set to alarm before the element becomes fully clogged. 1
2
1
2
3 3

MP Filtri can supply differential pressure indicators with a visual, electrical


IN IN IN
or both signals.

Suitable indicator types

DIFFERENTIAL INDICATORS
Differential indicators are used on the
Pressure line to check the efficiency of the OUT OUT OUT OUT
filter element.
They measure the pressure upstream
2
and downstream of the filter element 2 2 1
1 1 3
(differential pressure). 3 3
Standard items are produced with special
connection G 1/2” size.
Also available in Stainless Steel models.
IN IN IN IN

Quick reference guide


Visual Electrical Electrical / Visual Electronic
Filter series indicator indicator indicator indicator
LMP 110 - 112 - 116 - 118 - 119 MULTIPORT
LMP 120 - 122 - 123 MULTIPORT
LMP 210 - 211 - LDP DLA20xA51P01
With LMP 400 - 401 & 430 - 431 DLA20xA52P01
DVA20xP01 DEA20xA50P01
bypass LMP 900 - 901 DLA20xA71P01 DTA20xF70P01
DVM20xP01 DEM20xAxxP01
valve LMP 902 - 903 DLE20xA50P01
LMP 950 - 951 DLE20xF50P01
LMP 952 - 953 - 954
LMD 211 - 400 - 401 - 431 - 951 - LDD

LMP 110 - 112 - 116 - 118 - 119 MULTIPORT


LMP 120 - 122 - 123 MULTIPORT
LMP 210 - 211 - LDP DLA50xA51P01
Without LMP 400 - 401 & 430 - 431 DLA50xA52P01
DVA50xP01 DEA50xA50P01
bypass LMP 900 - 901 DLA50xA71P01 DTA50xF70P01
DVM50xP01 DEM50xAxxP01
valve LMP 902 - 903 DLE50xA50P01
LMP 950 - 951 DLE50xF50P01
LMP 952 - 953 - 954
LMD 211 - 400 - 401 - 431 - 951 - LDD
Low & Medium Pressure filters 444
DIFFERENTIAL INDICATORS
Dimensions

DEA*50 Hydraulic symbol Materials


- Body: Brass
Electrical Differential Indicator
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
2.0 bar ±10% DE A 20 x A 50 P01 3
- Seal: HNBR - FPM
5.0 bar ±10% DE A 50 x A 50 P01
Technical data
- Max working pressure: 420 bar
- Proof pressure: 630 bar 4
- Burst pressure: 1260 bar
Electrical symbol
- Working temperature: From -25 °C to +110 °C
3 - Compatibility with fluids: Mineral oils,
3 Synthetic fluids
53

53
2

50
1 1 HFA, HFB,1 HFC according to ISO 2943
3 - Degree protection: IP66 according to EN 60529
2 2
IP69K according to ISO 20653
A/F 30
Max tightening Electrical data
torque: 65 N∙m - Electrical connection: EN 175301-803
- Resistive load: 0.2 A / 115 Vdc

75
60
2
1
1
3 2

DEM*10 Hydraulic symbol Materials 4


3

Electrical Differential Indicator - Body: 5 Brass


- Base: Black Nylon
Settings Ordering code
2
- Contacts: Silver
1 1 24
2.0 bar ±10% DE M 20 x x 10 P01 3
- Seal: HNBR - FPM4
5.0 bar ±10% DE M 50 x x 10 P01
Technical data
3 3 - Max working pressure: 420 bar 3
1 Electrical symbol
1 - Proof pressure: 630 bar 1
2 2
- Burst pressure: 1260 bar 2
2 - Working temperature:
2 From -25 °C to +110 °C 2
Thermal lockout - Compatibility with fluids: Mineral oils,5 Synthetic fluids
75

2
flexible cable: 290 to “A”

HFA, HFB, HFC according to ISO 2943


60

1
1
3 - Degree protection:1 IP66 according to EN 60529 1

Electrical data
- Electrical connection: AMP Superseal series 1.5
- Resistive load: 0.2 A / 115 Vdc
- Switching type: Normally open contacts (NC on request)
A/F 28 - Thermal lockout: Normally open up to 30 °C (option “F”)
Max tightening
75

torque: 65 N∙m
60

2
1
1
2 C
3
2 DEM*20 2
Hydraulic symbol
3
Materials 2
A
4
- Body: Brass
Electrical Differential Indicator 5 B
1 1 - Base: 1 Black Nylon
Settings Ordering code 2 - Contacts: Silver
2.0 bar ±10% DE M 20 x x 20 1P01 1 2
- Seal: HNBR - FPM
3
5.0 bar ±10% DE M 50 x x 20 P01
Technical data
- Max working pressure: 420 bar
Electrical symbol - Proof pressure: 630 bar
C
- Burst pressure: 1260 bar
2 2 - Working temperature:
2 From -25 °C to +110 °C
Thermal lockout - Compatibility with fluids: Mineral oils, Synthetic fluids A
2
HFA, HFB, HFC according to ISO 2943B
75

1 1 1 1
60

3 - Degree protection: IP66 according to EN 60529

Electrical data
- Electrical connection: AMP Time junior
A/F 28 - Resistive load: 0.2 A / 115 Vdc
Max tightening - Switching type: Normally open contacts (NC on request)
torque: 65 N∙m
- Thermal lockout: Normally open up to 30 °C (option “F”)

2
1
1
3 2
3 C 445 Low & Medium Pressure filters
4
2 2
5
DIFFERENTIAL INDICATORS
Dimensions

75
60

DEM*30 Hydraulic symbol Materials


- Body: Brass
Electrical Differential Indicator
- Base: Black Nylon
2
Settings Ordering code1 - Contacts: Silver
1 2
2.0 bar ±10% DE M 20 x x 30 P01 3
- Seal: HNBR - FPM
5.0 bar ±10% DE M 50 x x 30 P01
Technical data
- Max working pressure: 420 bar
- Proof pressure: 630 bar
- Burst pressure: 1260 bar
Electrical symbol
- Working temperature:
C From -25 °C to +110 °C
2 2 2
- Compatibility with fluids: Mineral oils, Synthetic fluids
1 Thermal lockout
A HFA, HFB, HFC according to ISO 2943
75

3 - Degree protection:
B
IP66 according to EN 60529
1 1

Electrical data
- Electrical connection: Deutsch DT-04-2-P
A/F 28
- Resistive load: 0.2 A / 115 Vdc
Max tightening - Switching type: Normally open contacts (NC on request)
torque: 65 N∙m - Thermal lockout: Normally open up to 30 °C (option “F”)

2
75

1
1
3 2

DEM*35 C
Hydraulic symbol
3
4
Materials
Electrical Differential Indicator 5
- Body: Brass
2 - Base: Black Nylon
A
Settings Ordering code 2
- Contacts: Silver
1 1 2
2.0 bar1±10% DE M 20 x x 35 P01 B
3
- Seal: HNBR - FPM
5.0 bar ±10% DE M 50 x x 35 P01
Technical data
- Max working pressure: 420 bar
Electrical symbol - Proof pressure: 630 bar
- Burst pressure: 1260 bar
C - Working temperature: From -25 °C to +110 °C
Thermal lockout - Compatibility with fluids: Mineral oils, Synthetic fluids
2 2
HFA, HFB, HFC according to ISO 2943
flexible cable: 240 to “A”

A 1
3 - Degree protection: IP66 according to EN 60529
B
1
Electrical data
53

53

50

- Electrical connection: Deutsch DT-04-3-P


- Resistive load: 0.2 A / 115 Vdc
- Switching type: SPDT contact
2 - Thermal lockout: Normally open up to 30 °C (option “F”)
A/F 28 1 1 2
Max tightening 3
torque: 65 N∙m 2
1
1
3 2

DLA*51
C
- DLA*52 Hydraulic symbol Materials
3
4
- Body: Brass
Electrical/Visual
A Differential Indicator 5
- Base: Transparent Nylon
B
Settings Ordering code 2 - Contacts: Silver
2.0 bar ±10% DL A 20 x A x x P01 1 - Seal: HNBR - FPM
5.0 bar ±10% DL A 50 x A x x P01 3

Technical data
Electrical symbol - Max working pressure: 420 bar
4
- Proof pressure: 4
630 bar
- Burst pressure: 1260 bar
GREEN
LAMP
RED
LAMP
- Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
3 3 3HFA, HFB, HFC according to ISO 2943
53

50

1 1
2
- Degree protection: 1IP66 according to EN 60529

2 2 1
1 2
IP69K according to ISO 20653
3 2
Electrical data 3 5
A/F 30
Max tightening - Electrical connection:
4 EN 175301-803
torque: 65 N∙m - Type 5 51 52
- Lamps 24 Vdc 110 Vdc
- Resistive load: 1 A / 24 Vdc 1 A / 110 Vdc

Low & Medium Pressure filters 446


53

50
1
2 DIFFERENTIAL INDICATORS
1 2
3
Dimensions

DLA*71 Hydraulic symbol Materials


- Body: Brass
Electrical/Visual Differential Indicator
- Base: Black Nylon
Settings Ordering code 2
- Contacts: Silver
2.0 bar ±10% DL A 20 x A 71 P01 1
- Seal: HNBR - FPM
5.0 bar ±10% DL A 50 x A 71 P01 3
Technical data
- Max working pressure: 420 bar
2
- Proof pressure: 630 bar
- Burst pressure: 1260 bar
Electrical
1 symbol 1 2
3 - Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
4 4
HFA, HFB, HFC according to ISO 2943
50

GREEN
LAMP
RED
LAMP
- Degree protection: IP65 according to EN 60529
2 1 IP69K according to ISO 20653
3 3 1
3 2
1 A/F 30 1 Electrical data 3
2 Max tightening 2 2 - Electrical connection:
4
IEC 61076-2-101 D (M12)
torque: 65 N∙m 1 - Lamps 5 24 Vdc
5 3 - Resistive load: 0.4 A / 24 Vdc
59 58

DLE*A50 Hydraulic symbol Materials


- Body: Brass
58

58
Electrical/Visual Differential Indicator
- Base: Black Nylon
2
Settings Ordering code 1
- Contacts: 1 Silver
2.0 bar ±10% DL E 20 x A 50 P01 3 - Seal: 2 HNBR - FPM
5.04 bar ±10% DL E 50 x A 50 P01 3
Technical data 4
- Max working pressure:
5 420 bar
3 59 - Proof pressure: 58 630 bar
1
2 - Burst pressure: 1260 bar
1 1 - Working
2 temperature: From -25 °C to +110 °C
2 3
- Compatibility with fluids: Mineral oils, Synthetic fluids
5 HFA, HFB, HFC according to ISO 2943
Electrical symbol - Degree protection: IP65 according to EN 60529
58

58

3
3 Electrical data
1 - Electrical connections: EN 175301-803 1
- Resistive load: 5 A / 250 Vac
2 2 2
- Available the connector with lamps
1
A/F 32
3
Max tightening
torque: 95 N∙m
59 58

DLE*F50 Hydraulic symbol Materials


- Body: Brass
Electrical/Visual Differential Indicator 3
- Base: Black Nylon
58

3
Settings Ordering code 2 - Contacts: Silver
2.01bar ±10% DL E 20 x F 50 P01 1 1- Seal: 1 HNBR - FPM
3 2
5.02bar ±10% DL E 50 x F 50 P01 2
Technical data 3
4
- Max working pressure: 420 bar
58 - Proof pressure:5 630 bar
- Burst pressure: 1260 bar
- Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP65 according to EN 60529
Electrical symbol
58

3 Electrical data
Thermal lockout - Electrical connections: EN 175301-803
- Resistive load: 5 A / 250 Vac
1
- Thermal lockout setting: +30 °C
A/F 32 2
Max tightening
torque: 95 N∙m

447 Low & Medium Pressure filters


3
2
1

DIFFERENTIAL INDICATORS
3

Dimensions

DTA*70 Hydraulic symbol Materials

47

39
- Body: Brass

34
Electronic Differential Indicator
2
- Internal parts: Brass - Nylon
Settings Ordering code 1 - Contacts: Silver Industry 4.0
1 READY
2.0 bar ±10% DT A 20 x x 70 P01
3 2 - Seal: HNBR - FPM
5.0 bar ±10% DT A 50 x x 70 P01 3
4 Technical data
5 - Max working pressure: 420 bar
- Proof pressure: 630 bar
- Burst pressure: 1260 bar
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP67 according to EN 60529
47

39
Electrical symbol

34
Electrical data
1 +24 Vdc - Electrical connection: IEC 61076-2-101 D (M12)
- Power supply: 24 Vdc
A/F 30 2 4 ÷ 20 mA
- Analogue output: From 4 to 20 mA
Max tightening 75% - N.O.
torque: 50 N∙m
3 Digital output - Thermal lockout: 30 °C (all output signals stalled up to 30 °C)
100% - N.O.
4 Digital output
5 0 Vdc

DVA Hydraulic symbol Materials


Visual Differential Indicator - Body: Brass
- Internal parts: Brass - Nylon
1 +24 Vdc
Settings Ordering code - Contacts: Silver
2.0
2 bar ±10% 4 ÷ 20 mA
DV A 20 x P01 - Seal: HNBR - FPM
5.0
3 bar ±10% DV A 50 x P01
75% - N.O.
Technical data
100% - N.O.
4 - Reset: Automatic reset
5 0 Vdc
- Max working pressure: 420 bar
Green / Red - Proof pressure: 630 bar
clogging indicator - Burst pressure: 1260 bar
- Working temperature: From -25 °C to +110 °C
2 - Compatibility with fluids: Mineral oils, Synthetic fluids
39

34

1 2
3
1
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP65 according to EN 60529
A/F 28
Max tightening
torque: 65 N∙m

2
1
3

DVM Hydraulic symbol Materials


- Body: Brass
Visual Differential Indicator
- Internal parts: Brass - Nylon
Settings Ordering code - Contacts: Silver
2.0 bar ±10% DV M 20 x P01 - Seal: HNBR - FPM
5.0 bar ±10% DV M 50 x P01
2 Technical data
1
1 - Reset: Manual reset
3 2
- Max working pressure: 420 bar
3
- Proof pressure: 630 bar
4
Red - Burst pressure: 1260 bar
clogging indicator 5
- Working temperature: From -25 °C to +110 °C
2 - Compatibility with fluids: Mineral oils, Synthetic fluids
34

1 1
2 HFA, HFB, HFC according to ISO 2943
3
- Degree protection: IP65 according to EN 60529

A/F 30
Max tightening
torque: 65 N∙m

2
1
3

Low & Medium Pressure filters 448


DIFFERENTIAL INDICATORS

10
Dimensions

A/F30 T2 Materials
- Body: Phosphatized steel
Indicator plug
- Seal: HNBR / FPM
Seal Ordering code
HNBR T2 H
FPM T2 V

A/F 30
Max tightening
torque: 50 N∙m

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATORS


Series Configuration example 1: DE M 20 H F 50 P01
DE Electrical differential indicator Configuration example 2: DL E 50 V A 71 P01
DL Electrical/Visual differential indicator
Configuration example 3: DT A 20 H F 70 P01
DT Electronic differential indicator
DV Visual differential indicator Configuration example 4: DV M 50 V P01
Type DE DL DT DV
A Standard type • • • A With automatic reset
M With wired electrical connection • M With manual reset
E For high power supply •
Pressure setting
20 2.0 bar
50 5.0 bar
Seals
H HNBR
V FPM
Thermostat DEA DEM DLA DLE DT DV
A Without • • • •
F With thermostat • • •
Electrical connections DEA DEM DLA DLE DT DV
10 Connection AMP Superseal series 1.5 •
20 Connection AMP Timer Junior •
30 Connection Deutsch DT-04-2-P •
35 Connection Deutsch DT-04-3-P •
50 Connection EN 175301-803 • •
51 Connection EN 175301-803, transparent base with lamps 24 Vdc •
52 Connection EN 175301-803, transparent base with lamps 110 Vdc • Option
70 Connection IEC 61076-2-101 D (M12) • P01 MP Filtri standard
71 Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc • Pxx Customized

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG


Series Configuration example T2 H
T2 Indicator plug
Seals
H HNBR
V FPM

449 Low & Medium Pressure filters


Low & Medium Pressure filters

Accessories
RETAINING CLAMP

example
LMP950

Mounting holes

Series Configuration example: CFA 20 M P01


CFA Retaining clamp

Size
20

Screw
M Metric

Execution
P01 MP Filtri standard

Low & Medium Pressure filters 450


451 Low & Medium Pressure filters
Clogging indicators are devices that check the life time of the filter elements.
They measure the pressure drop through the filter element directly connected
to the filter housing.
These devices trip when the clogging of the filter element causes a pressure drop
increasing across the filter element.
Filter elements are efficient only if their Dirt Holding Capacity is fully exploited.
This is achieved by using filter housings equipped with clogging indicators.
The indicator is set to alarm before the element becomes fully clogged.

MP Filtri can supply indicators of the following designs:


- Vacuum switches and gauges
- Pressure switches and gauges
- Differential pressure indicators

These type of devices can be provided with a visual, electrical or both signals.
The electronic differential pressure clogging indicator is also available.
It provides both analogical 4-20 mA output and digital warning (75% of clogging)
and alarm (clogging) outputs.

Clogging Indicators 636


Clogging Indicators

637 Clogging Indicators


Clogging indicators

Clogging indicators

OUT OUT OUT

2 2
1 1
3 3

Suitable indicator types OUT OUT OUT

2 2
1 1
3 3
IN IN IN
OUT OUT OUT
VACUUM INDICATORS
Vacuum indicators are used on the Suction line to check the efficiency 1
2
1
2
of the filter element. 3 3

They measure the pressure downstream of the filter element. IN IN IN


Standard items are produced with R 1/4” EN 10226 connection.
Available products with R 1/8” EN 10226 to be fitted on MPS series.
IN IN IN

OUT OUT OUT

OUT 2
OUT 2
OUT
1 1
BAROMETRIC INDICATORS 3 3

Pressure indicators are used on the Return line to check the


IN IN IN
efficiency of the filter element. OUT OUT OUT
They measure the pressure upstream of the filter element. 2 2
1 1
Standard items are produced with R 1/8” EN 10226 connection. 3 3

IN IN IN
2 2
1 1
3 3

IN IN IN

DIFFERENTIAL INDICATORS OUT OUT OUT OUT


Differential indicators are used on the Pressure line to check the
efficiency of the filter element. 2
They measure the pressure upstream and downstream of the 1
2
1
2 1
3
3 3
filter element (differential pressure). OUT OUT OUT O
Standard items are produced with special connection G 1/2” size.
Also available in Stainless Steel models.
IN IN 2
IN 2
IN 1
2
OUT 1 OUT 1 OUT 3 O
3 3

2
2 2 1
IN 1 IN 1 IN 3
3 3

IN IN IN

Clogging Indicators 638


QUICK REFERENCE GUIDE CLOGGING INDICATORS
Filter Filter Electrical Electrical / Visual Electronic Visual
family series indicator indicator indicator indicator

VLB21AA51P01
VLB21AA52P01 VVB16P01
VEB21AA50P01
SFEX060-080-110-160 VLB21AA53P01 VVS16P01
SUCTION
FILTERS

VLB21AA71P01

VLA21AA51P01
SF2 250 - 350
VLA21AA52P01 VVA16P01
SF2 500 - 501 - 503 - 504 - 505 VEA21AA50P01
VLA21AA53P01 VVR16P01
SF2 510 - 535 - 540
VLA21AA71P01

BLA15HA51P01 BVA14P01
With
BEA15HA50P01 BLA15HA52P01 BVR14P01
bypass
RFEX060-080-110-160 BEM15HA41P01 BLA15HA53P01 BVP15HP01
valve
BLA15HA71P01 BVQ15HP01

BLA20HA51P01 BVA25P01
Without
BEA20HA50P01 BLA20HA52P01 BVR25P01
bypass
RFEX060-080-110-160 BEM20HA41P01 BLA20HA53P01 BVP20HP01
valve
BLA20HA71P01 BVQ20HP01

BLA15HA51P01 BVA14P01
With MPFX-MPTX-MPF-MPT - bypass 1.75 bar
BEA15HA50P01 BLA15HA52P01 BVR14P01
RETURN
FILTERS

bypass MPH - bypass 1.75 bar


BEM15HA41P01 BLA15HA53P01 BVP15HP01
valve RF2250 - RF2350 - bypass 1.75 bar
BLA15HA71P01 BVQ15HP01

MPFX-MPTX-MPF-MPT - bypass 3 bar BLA20HA51P01 BVA25P01


With
MPH - bypass 2.5 bar BEA20HA50P01 BLA20HA52P01 BVR25P01
bypass
FRI 255 BEM20HA41P01 BLA20HA53P01 BVP20HP01
valve
RF2250 - RF2350 - bypass 3 bar BLA20HA71P01 BVQ20HP01

DEA20xA50P01 DLA20xA51P01
DEM20xA10P01 DLA20xA52P01
MPLX DVA20xP01
DEM20xA20P01 DLA20xA71P01 DTA20xF70P01
FRI 025 - 040 - 100 - 250 - 630 - 850 DVM20xP01
DEM20xA30P01 DLE20xA50P01
DEM20xA35P01 DLE20xF50P01

VLB21AA51P01
Suction VLB21AA52P01 VVB16P01
MRSX 116 - 165 - 166 VEB21AA50P01
RETURN / SUCTION

line VLB21AA53P01 VVS16P01


VLB21AA71P01
FILTERS

BEA25HA50P01
BLA25HA51P01 BVA25P01
BEM25HA41P01
Return MRSX 116 - 165 - 166 BLA25HA52P01 BVR25P01
BET25HF10P01
line LMP 124 MULTIPORT BLA25HA53P01 BVP20HP01
BET25HF30P01
BLA25HA71P01 BVQ20HP01
BET25HF50P01

VLB21AA51P01
Suction MPS 050 - 070 - 100 - 150 VLB21AA52P01 VVB16P01
VEB21AA50P01
line MPS 200 - 250 - 300 - 350 VLB21AA53P01 VVS16P01
VLB21AA71P01

BLA15HA51P01 BVA14P01
Return MPS 050 - 070 - 100 - 150 BEA15HA50P01 BLA15HA52P01 BVR14P01
SPIN-ON

line MPS 200 - 250 - 300 - 350 BVP20HP01


FILTERS

BEM15HA41P01 BLA15HA53P01
BLA15HA71P01 BVQ20HP01

DLA12xA51P01
DLA12xA52P01
DTA12xA70P01
MPS 051 - 071 - 101 - 151 DLA12xA71P01
DEA12xA50P01 DTA12xF70P01 DVA12xP01
In-line MPS 301 - 351 DLE12xA50P01
DEM12xAxxP01 DTA20xA70P01 DVM12xP01
MSH 050 - 070 - 100 - 150 DLE12xF50P01
DTA20xF70P01
DLE20xF50P01
DLE20xF50P01

639 Clogging Indicators


CLOGGING INDICATORS QUICK REFERENCE GUIDE
Electrical Electrical / Visual Electronic Visual Hazardous
Filter Filter area electronic
family series indicator indicator indicator indicator indicator
With DES25HA10P01
bypass DES25HA30P01 DVS25HP01
LFEX060-080-110-160
valve DES25HA80P01

Without DES40HA10P01
bypass DES40HA30P01 DVS40HP01
LFEX060-080-110-160
valve DES40HA80P01

LMP 110 - 112 - 116 - 118 - 119 MULTIPORT


DVS25HP01
LMP 120 - 122 - 123 MULTIPORT
DLA20xA51P01 DVS40HP01
LMP 210 - 211 - LDP
PRESSURE FILTERS
LOW & MEDIUM

With LMP 400 - 401 & 430 - 431 DLA20xA52P01


DEA20xA50P01 DVA20xP01
bypass LMP 900 - 901 DLA20xA71P01 DTA20xF70P01
DEM20xAxxP01 DVM20xP01
valve LMP 902 - 903 DLE20xA50P01
LMP 950 - 951 DLE20xF50P01
LMP 952 - 953 - 954
LMD 211 - 400 - 401 - 431 - 951 - LDD

LMP 110 - 112 - 116 - 118 - 119 MULTIPORT


LMP 120 - 122 - 123 MULTIPORT
LMP 210 - 211 - LDP DLA50xA51P01
Without LMP 400 - 401 & 430 - 431 DLA50xA52P01
DEA50xA50P01 DVA50xP01
bypass LMP 900 - 901 DLA50xA71P01 DTA50xF70P01
DEM50xAxxP01 DVM50xP01
valve LMP 902 - 903 DLE50xA50P01
LMP 950 - 951 DLE50xF50P01
LMP 952 - 953 - 954
LMD 211 - 400 - 401 - 431 - 951 - LDD

FMP 039 - 065 - 135 - 320


FHP 010 - 011 - 065 - 135 - 350 - 500 DEH50xA48P01
DLA50xA51P01
FMM 050 - 150 DEH50xA49P01
With DLA50xA52P01
FHA 051 DEA50xA50P01 DVA50xP01 DEH50xA70P01
bypass DLA50xA71P01 DTA50xF70P01
FHM 006 - 007 - 010 - 050 - 065 - 135 - 320 - 500 DEM50xAxxP01 DVM50xP01 DEH70xA48P01
valve DLE50xA50P01
FHB 050 - 065 - 135 - 320 DEH70xA49P01
FHF 325 DLE50xF50P01
DEH70xA70P01
HIGH PRESSURE

FHD 021 - 051 - 326 - 333


FILTERS

DLA70xA51P01
FMP 039 - 065 - 135 - 320 DLA70xA52P01
FHP 010 - 011 - 065 - 135 - 350 - 500 DEH50xA48P01
DLA70xA71P01
FMM 050 - 150 DEA70xA50P01 DVA70xP01 DEH50xA49P01
Without DLE70xA50P01
FHA 051 DEM70xAxxP01 DTA70xF70P01 DVM70xP01 DEH50xA70P01
bypass DLE70xF50P01
FHM 006 - 007 - 010 - 050 - 065 - 135 - 320 - 500 DEA95xA50P01 DTA95xF70P01 DVA95xP01 DEH70xA48P01
valve DLA95xA51P01
FHB 050 - 065 - 135 - 320 DEM95xAxxP01 DVM95xP01 DEH70xA49P01
FHF 325 DLA95xA52P01
DEH70xA70P01
FHD 021 - 051 - 326 - 333 DLE95xA50P01
DLE95xF50P01

FZH 010 - 011 - 039 DEH50xA48P01


FZP 039 - 136 DEH50xA49P01
With
FZX 011 DLX50xA51P01 DVX50xP01 DEH50xA70P01
HIGH PRESSURE FILTERS

bypass DEX50xA50P01
FZB 039 DLX50xA52P01 DVY50xP01 DEH70xA48P01
valve
STAINLESS STEEL

FZM 039 DEH70xA49P01


FZD 051 DEH70xA70P01

DEH50xA48P01
FZH 010 - 011 - 039 DVX70xP01 DEH50xA49P01
Without FZP 039 - 136 DLX70xA51P01
DEX70xA50P01 DVY70xP01 DEH50xA70P01
bypass FZB 039 DLX70xA52P01
DEX95xA50P01 DVX95xP01 DEH70xA48P01
valve FZM 039 DLX95xA51P01
DVY95xP01 DEH70xA49P01
FZD 010 - 021 - 051
DEH70xA70P01

640
All data, details and words contained in this publication are provided for information purposes only.
MP Filtri reserves the right to make modifications to the models and versions of the described products at any time
for both technical and / or commercial reasons.
The colors and the pictures of the products are purely indicative.
Any reproduction, partial or total, of this document is strictly forbidden.
All rights are strictly reserved.
WORLDWIDE NETWORK

HEADQUARTERS
MP Filtri S.p.A.
Pessano con Bornago
Milano - Italy
+39 02 957031
[email protected]

BRANCH OFFICES
ITALFILTRI LLC MP Filtri India Pvt. Ltd.
Moscow - Russia Bangalore - India
+7 (495) 220 94 60 +91 80 4147 7444 / +91 80 4146 1444
[email protected] [email protected]

MP Filtri Canada Inc. MP Filtri (Shanghai) Co., Ltd.


Concord - Ontario - Canada Shanghai - Minhang District - China
+1 905 303 1369 +86 21 58919916 116
[email protected] [email protected]

MP Filtri France SAS MP Filtri U.K. Ltd.


Villeneuve la Garenne Bourton on the Water
France Gloucestershire - United Kingdom
+33 (0)1 40 86 47 00 +44 (0) 1451 822 522
[email protected] [email protected]

MP Filtri Germany GmbH MP Filtri U.S.A. Inc.


St. Ingbert - Germany Quakertown, PA - U.S.A.
+49 (0) 6894 95652-0 +1 215 529 1300
[email protected] [email protected]

PASSION TO PERFORM
EN - Rev. 10-2020
CMPEN001G

mpfiltri.com

You might also like